Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.8 L+₹95,240 (8.04%)Rejected-Finance | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹13.7 L+₹1.8 L (15.6%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L3 | Rejected-Finance Quoted amount more than L1 |
Tender Value
₹14.9 L
EMD Value
₹30,000
Closing Date
10 Feb 2020, 4:00 pmClosed
Maj Vipin V Kumar
Garrison Engineer 07th Club Road Ranchi 834001
REPAIRS/REPLACEMENT OF ELECTRICAL FITTINGS/FIXTURES REWIRING AND CONNECTED ITEMS OF WORKS AT LPH/RANCHI UNDER GE RANCHI
2020_MES_314450_1
8400/1085/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat b (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹30,000
Yes
19 Mar 2020
13 Jan 2020
11 Feb 2020
14 Jan 2020
10 Feb 2020
24 Jan 2020
Amount
Taking down carefully aluminium point wiring any type including battens if any except for ceiling or where not feasible for light/ fan/bell,socket or power and including unscrewing from board, fitting and fixure such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and directed.
Taking down Aluminium sub main wiring including GI earth wire and making good disturbed surfaces to match with the existing surface roof,wall,floor complete all as specified and as directed.
M&L for sub main wiring with two single core FR 4 Sqmm copper conductor PVC unsheathed cable medium grade including PVC conduit (appropriate size) concealed in wall for sub main connection including FR 4 Sqmm PVC insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and directed all as specified.( Note :- Three runs of 4 sqmm copper conductor shall be measured as one unit length. ie Phase, Neutral, Earth)
M&L point wiring with 1.5 Sqmm multistranded PVC insulated and unsheathed copper conductor cable in and including surface caping and casing complete with 1.60 mm thick pressed steel concealed terminal boxes and with top cover 2.80 mm thick ISI marked plastic laminated hylum sheet of reqd colour fixed with brass screws and cup washers, painting terminal boxes inside and out side with one coat red oxide primer complete with all accessories and all as specified including FRLS 1.5 Sqm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth dolly for following:- Note : (i) All wiring cable shall be multistranded FR copper conductor of approved make duly approved by accepting officer before incorporating. (ii) Colour code as per IS to be followed for wiring. (iii) Same size of conducor use in any type of wiring (Phase/Nutral/earth conductor shoud be same size.
One light/fan/exhaust fan point controlled by one switch .
One 5 Pin 5 Amp switch socket out let point on same board.
All as per item 4 here in before but for one 5 Amp 5 Pin switch socket out let independent with 2.5 Sqmm FR (Nominal Area) PVC unsheathed copper conductor single core multistranded complete all as specified.
All as per item 4 here in before but for one 15 Amp 6 Pin switch socket out let independent with 4 Sqmm FR (Nominal Area) PVC unsheathed copper conductor single core multistranded complete all as specified and directed
S&F sheet metal enclosure for double door DBs for using MCBs single pole and neutral 8 way with 200 Amps rated busbar 240 Volt all as completed specified and diected by Engrs-in - Charge
S&F sheet metal enclosure for double door DBs for using MCBs single pole and neutral 4 way with 200 Amps rated busbar 240 Volt complete all as specified and directed
S&F Isolator doble pole 40 Amp 240 volt.
S&F MCB single pole 6 to 32 Amp 240 Volt 'B' curve 10 KA complete all as specified and directed .
S&F switch piano flush type 5 Amp single pole one way.
S&F Switch socket combinations flush 5 Amp 5 Pin complete.
S&F switch socket combination out let 6 Pin 2 in 1, 5/15 Amp flush type 240 Volt complete.
Supply and fixing socket out let 2 in 1,3 pin, 5 Amp flush type
S&F ceiling rose surface bakelite 65x50mm three terminal AC 230 volts complete all as specified and directed.
S&F of flexible wire twin core copper conductor of size 23/.0076 for flourescent tube light fitting/ fan up to 1.00 mtr all as specified and directed.
S&F Electronic regulator step type 450 watt 230 Volt 50 C/S.
S&F in replacement of decorative wall mounting luminaries light suitable for LED bulb 9/11 watt with all accessories like lamp holders etc complete with pre-wired complete all as specified Make - Philips/Wipro/ Bajaj/Havells.
T/D the existing ceiling fan and Refixing the same complete all as specified and directed .
S & F in replacement LED Tube light with aluminium body fitting 1 x 18 W Energyefficient. Box type Epoxy powder coated CRCA sheet housing with reflector cover Chanel, without electronic ballast, Bipin Holder, connector Block, etc complete LED tube rod & excluding connecting up with twin core twisted flexible copper conductor cable of suitable size all as directed. Cat part No-LT5RT1-18-CDL Make-Crompton/Bajaj/Philips.
Supply and fixing bell push flush type AC 230 Volt
Supply and fixing call bell ding-dong type AC 230 Volt
S&F LED Mirror Light 9 Watt 600mm long with lux output 900 lumins i.e 100 lumins/per watt
S&F angle holder with LED Lamp of 9 watt Watt complete all as specified & directed.
M & L Earthing complete with galvanized GI earth plate electrode of size 600 x 600 x 6.00 mm ,buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level)with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts ,nuts ,check nuts of galvanized iron or steel including excavation and earth work in any type of soil, charcoal salt filling 15 cm around the earth plate as shown in electrical plate no 3 of SSR part-I 2004, 20 mm bore, GI watering pipe medium grade 1.50 mtr long & GI protection pipe light grade 15 mm dia from earth pit to main board including making pit with PCC 1:3:6 type C1 and pre cast RCC cover 40 mm thick, reinforced with 8mm dia deformed bars @ 100 mm c/c both ways with lifting handles and funnel etc including testing as directed.
S&F in replacement of electronic chock 36/40 Watt ISI marked Make - Philips/ Bajaj/Havells
S&F in replacement of 5 Amp socket out let 5 pin ISI marked Make - Philips/ Bajaj/Havells/Anchor
S&F in replacement of switch socket combinations flush 5 Amp 5 pin competeI ,ISI marked Make - Philips/ Bajaj/Havells/Anchor
S&F in replacement of tube rod LED type of 18 watt Make- Philips/Bajaj/Havells
S&F LED bollard light 10 Watt in spherical shape polycarbonate diffuser and IP 65 protection Make Bajaj/Cormptom
S&F or fising or passing through pipe 1100 volts grade heavy duty cable with insulated aluminium conductor served with an inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanger not more than 1 myr apart including 4 mm suspension wire area 10 Sq mm 2 Core
Om Construction
BHARATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .