Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC Lowest one | |
| 2 | L2₹51.4 L+₹3.1 L (6.42%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹88.9 L+₹40.5 L (83.9%)Rejected-Finance NOT AVAILABLE | L3 | Rejected-Finance Other than lowest | |
| 4 | Rejected-Technical ROOM NO A G E 87 EAST GEETANAGAR NAVY NAGAR COLABA MUMBAI 05 | MUMBAI | MAHARASHTRA | 400005 | - | Rejected-Technical Not meeting eligibility criteria |
Tender Value
Refer Docs
EMD Value
₹99,960
Closing Date
27 Feb 2024, 6:00 pmClosed
GE NW NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
DEMOLITION AND RECONSTRUCTION OF THREE WATCH TOWERS (A B AND E) AND SPECIAL REPAIR TO BIRD PROOFING NET AND ASSOCIATED WORK IN BLDG NO T72B AT INS SHIKRA UNDER GE(NW) NOFRA COLABA MUMBAI
2024_MES_640007_1
8243
Open Tender
Miscellaneous Works
Item Rate
180 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹99,960
Yes
14 Mar 2024
31 Jan 2024
29 Feb 2024
31 Jan 2024
27 Feb 2024
13 Feb 2024
31 Jan 2024 - 7 Feb 2024
Amount
Submission of detailed plan, section, architechural and structural drawing for watch tower of height 10.50m ('E' Tower) 8.50m ('A'&'B' Tower) above GL and designed by any structural consultant as per the recommandation of soil investigation and duly vetted by any Govt institution complete as specified and directed
Excavation in trenches not exc 1.5 m in depth and n exc 1.5 m in width for foundatins, etc or for shafts, wells, cesspits, manholes, pier holes and getting out in hard/ dense soil, complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavation material exceeding 1.50 km but n exceeding 15 km and depositing where directed
Material & labour hardcore of broken stone or boulders of guage exceeding 63mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rolled/rammed to a true surface
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) in foundation filling and mass concreting complete all as specified and directed.
M&L for RCC (design mix) M-30 (using 20mm graded stone aggregate) as in footing, foundation beams, plinth beams, bases for columns, etc, basement slabs, under reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (design mix) M-30 (using 20mm graded stone aggregate) for slabs supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC (design mix) M-30 (using 20mm graded stone aggregate) as in roof beams, cantilevers, bressummers lintels over 1.5m span complete all as specified and directed.
Material & labour RCC (design mix) M-30 (using 20mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
Material & labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with
Material & labour for mild steel TMT bars 5mm dia and over upto & including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with complete all as specified and directed.
Use & Waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter fair finished surfaces.
Use & Waste flat Formwork to sides of pillars, posts, struts, piers, columns and stanchions fair finished surfaces.
Use & Waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc fair finished surfaces.
Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (horizontal or sloping) fair finished surfaces.
Use & Waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide fair finished ,complete all as specified.
Mobilisation and demobilisation of men and materials to the site, field work by calyx upto the depth of 10mtrs or upto refusal strata where N valve is obtained more than 50/100, conducting penetration test at the change of layers and at specified intervals of 1mtr. The relative density of cohesionless layers and consistency of cohesion layers as obtained from N value will be furnished in the borelogs. The undisturbed soil samples to be collected at every 1 mtrs. Collecting both disturbed and undisturbed soil samples at change of layers and at specified intervals and performing relevant laboratory tests on the samples collected and submitting the report, which broadly include the scope of invstigaion, exploration technique, soil profile of borelogs, analysis of various laboratory tests, recommendation including the following: -
(i) Depth of bore holes taken upto 10mtr or N valve reaches 50/100. (ii) SPT value at every 1mtr intervals and change of strata. (iii) Grain size distribution and analysis. (iv) Soil characterstics. (v) Value of cohesion and angle of internal friction. (vi) Recommeded SBC at different depth of foundation i.e at 900mm, 1000mm, 1200mm, 1500mm & 1750mm etc. (vii) SBC and its calculation based on N-Value shear strength and settlement criteria. (viii) Depth of water table (maximum and minimum) (ix) Depth of expansive soil and its proprties, if any. (x) Recommendation of type of foundation for different structure including buildings for single double/ triple storied construction. (xi) Recommendation of filling under floors and filling under protection including plinth protection. (xii) Chemical analysis of soil and recommendation and type of cement to be used for RCC foundation details of soil profile and bore logs. (xiii) Any other recommendations.
Supply and fix colour powder coated (50 micron minimum thickness) aluminium section for sliding/fixed in frame/shutter for doors, windows, ventilators etc with one or more rebate, including joining cleats for fixing, fixed type/louvered window or ventilator with or without sash bars including necessary locking arrangements, glazing clips, rubber packing, anodized aluminium snap beading, screws etc complete all as specified and directed. Make :- Jindal / Hindalco / Indalco Note :- (i) Glazing shall be measured and paid separately. (ii) Item shall be paid as per weight of aluminium sections as per manufacturer catalogue. However the rate quoted shall be inclusive of the cost of neoprene beading, glazing pin, screws, appropriate handle, locking arrangement etc.
Supply & fix 4.80mm thick Sheet glass, ordinary quality in square exceeding 0.50Sqm each pane, fixed to Aluminium section complete all as specified.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
Supply & fix 12mm thick prelaminated partical boand exterior grade laminated on both side with decorative choice lamination fixed to aluminium frame work for door panel shutter complete all as directed and specified.
S&F powder coated aluminium grill with and including suitable powder coated aluminium anodised frame F/H section as required manufactured by M/S Decogrill as per design No DG- 104, 7.5 mm thick all as specified and as directed.
M&L 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over and including 15mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding complete all as apecified and directed.
Material & labour for coloured glazed ceramic tiles 450 x 300 x 7mm thick but as on vertical surfaces such as skirting/dado including 15mm thick backing coat in CM (1:4), complete all as specified.
Material & labour for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick cement screed bed in CM (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
Material & labour for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified.
Material & labour for Rendering 15mm thick cement plaster in cement mortor 1:4 on brick or concrete surfaces mixed with water proofing compound @ 2% by the weight of cement , surfaces to be finished even and smooth without using extra cement, complete all as specified. [Note:-WPC shall be measured and paid separately].
Supply only integral water proofing compound.
Material & labour Rendering 10mm thick cement plaster in cement mortor 1:3 on ceiling surfaces, surfaces to be finished even and smooth without using extra cement, complete all as specified.
Material & labour for Preparation of newly plastered surfaces of ceiling and applying 2 coats of oil bound distemper over a coat of primer on 2mm thick interior wall care putty complete all as specified and directed.
Material & labour for Preparation of newly plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint (all weather proof) of required shade over a coat of exterior primer, complete all as specified.
M&L for rendering 10mm thick cement plaster in cement Mortar 1:4 on concrete surfaces as on roof finished even and smooth without using extra cement complete all as specified and directed.
Material & labour for providing in repairs water proofing treatment with 3mm APP (Atactic polypropylene) modified polyester(bituminous) membrane reinforced of 3.5Kg/Sqm with non woven polyester mat of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer @ 0.25 Kg/Sqm over roof (An overlap of 100mm and 150mm shall be provided on sides and ends respectively) and applying two coats of aluminium paint on APP sheet complete all as specified and directed.
M&L for Mild Steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. in?cluding cleats, brackets, etc. complete
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide, complete all as specified.
M&L for Machine pressed precast concrete interlocking paver block having glossy finish shape and size as approved by GE confirming to IS 15658-2006 of 60mm thickness, M-35 Grade of with grey cement and pigments laid over and including 50 mm thick dry sand cushioning and voids filled with dry and surface compact, including compaction by means of surface vibrator complete all as specified and directed.
Taking down chowkats or frames but exceeding 1.5 sqm each but n exc 4 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed.
Demolition of reinforced cement concrete roofs , floors (other than ground floors) beams, staircase, landing chajjas, columns and similar work (reinforcement cut as required to facilitate demolition), below or above ground level complete all as specified.
Dismantling of structural steel work including ladder and gate, all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
Dismantling floor, hearth, cement concrete tiles, interocking paver block including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Removing building materials etc. (other than spoil payable under items to a distance of 50 KM or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination as per directions of BMC, complete all as specified.
Dismantling of safety net/ bird proofing mesh of any thickness and size fixed with steel frame work including necessary scaffolding same scaffolding shall be utilized for installation/fabrication of bird netting complete all as specified and directed.
S&F Mild steel galvanised PVC Coated wire netting to ceiling, dia of wire 2mm and size of mesh 25mm x 25mm fixed with 3mm dia GI Wire and cleat complete including tightening of wire netting etc complete all as specified and directed.
M & L for Point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated sheathed copper conductors 1100 volts grade drawn through & including PVC casing caping ISI marked with accessories on wall/ceiling/truss including cutting chases, pinning in etc with PVC non metallic ISI marked terminal boxes concealed wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for the following
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC non-metallic concealed coduit including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
S&F Modular Switch , 6Amp, One way, 1 module, ISI marked
S&F Modular Switch , 16Amp, One way, 1 module, ISI marked
S&F Modular Socket , 6 Amps, 2/3 pin combined 2 module, ISI marked.
S&F Modular Socket , 16Amps, 6 pin combined 2 module, ISI marked.
S&F Modular type, electronic fan regulator ( 5 step ), 120 Watts, 230 volts, 2 module, ISI marked.
S&F ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed.
S&F Modular white cover plate with Frame 4 Module, ISI marked.
S&F Modular white cover plate with Frame 6 Module, ISI marked.
S&F Modular white cover plate with Frame 8 Module, ISI marked.
S&F Modular metal flush box 4 module, ISI marked and incluing cutting hole in wall / ceiling/piller etc and making good surface.
S&F Modular metal flush box 6 module, ISI marked and incluing cutting hole in wall / ceiling/piller etc and making good surface.
S&F Modular metal flush box 8 module , ISI marked and incluing cutting hole in wall / ceiling/piller etc and making good surface.
Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing exhaust fan , steel body AC single phase, 230 volt of size 250 / 300 mm sweep 1200 RPM with blades, and frame and louvers complere fixing arrangements on the wall with nuts and bolts making the good surfces all as specifed and directed by engineer in charge
Supply and fixing ceiling fans complete with blades, down rods with sefty GI wire connecting up to fan hook, electronic regulaor and accessories , 230 volts , 1200 sweep. Min air delivery 210 CFM with wervice value 6.0 BEE. Five star rated with brushles diret current motor and connectding jup including provision of flexible 3 core copper cable.
Supply & fix MCB DB SPN 12 ways 415 volts with sheet metal enclosures and 200 Amps rated bus bars double door type suitable for MCB's.
MCB SPN 63 Amps, 10 KA rupturing capacity
MCB SP 32 Amps, 10 KA rupturing capacity
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point
Supply, laying and testing cable Insulated, screened, pvc bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 voltsgrade with stranded aluminium conductor of size 16.0 Sqmm 2 core
Material & labour for for stand post made of mild steel angle of size 50 x 50 x 6mm and mild steel on top of thickness 6mm complete with drilling welding nuts bolts and washer for fixing of search light including painting with synthetic enammeld paint as per Engineer-in-Charge norms over one coat of red oxide primer all as specified and directed by Engineer-in-Charge.
Supply & fix LED type security search light for 2000 Watt fitting as per AJMERA (marine search light) weather proof cromium plated brass body, wheel house arrangements for both vertical and horizontal direction made out of brass sheet complete with heat resistant toughned glass with hot air scape arrangement with LED lamp provided on security watch tower situted along the perimeter of sea wall and area all as specified and directed by Engineer-in-Charge.
Supply and fixing LED flood light 170 watt 230 V AC outdoor type with thermal manageent in multiple optics and equipped with IP 66 protection with impect and corrosion resistant complete with driver and lamp with complete fitting of flood light as directed by Engr in charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strips 25 x 4 mm.
Taking down old cable and Supply and laying / fixing XLPE Armoured cable aluminium conductor PVC insulated and sheathed cable 1100 volt of size 2 core 10 Sqmm laid in trenches/ through pipe/ ducts/ angle or fixed on wall etc through PVC pipe size (not less than 25/ 20 mm dia ) from DB / panel board to floot light or fixed on angle with sadling and sadling distance each other 01 mtr complete all as specified and directed by Engineer-in-charge. Note : Near each hightbay light fix 01 Nos PVC round/squar box for cable connection.
Taking down old cable and Supply and laying / fixingXLPE Armoured cable aluminium conductor PVC insulated and sheathed cable 1100 volt of size 4 core 16 Sqmm laid in trenches/ through pipe/ ducts/ angle or fixed on wall etc through PVC pipe size (not less than 25 mm dia ) from DB / panel board to floot light or fixed on angle with sadling and sadling distance each other 01 mtr complete all as specified and directed by Engineer-in-charge.
Taking down old U/S cable and Supply, laying, commisssion & testing XLPE insulated armoured LT cable, 110 Volts grade with aluminium conductor of size 3.5 core 35 Sqmm laid in trenches/ through pipe/ ducts or fixed on wall etc complete all as specified and directed.
Taking down old U/S light and Supply & fix in repair Industrial highbay integral LED fittings of capacity 120 watt luminaire with high efficacy capacity in aluminium pressure die cast housing with touched glass cover with IP 65 protection complete and all accessories at top of any height of workshop hanger including proper hanging fixing with angle/rond bar flat iron with clamping as good appearnce complete all as specified and directed by Engr-in-charge. Make- Jaquar lighting Cat No - LHBL090120XW or its equivalent make as specified in list of make
Taking down U/S old U/S looping box and Supply and fixing FRP type looping box of size 250 x 125 x 100 mm including necessary arrangement to fix the looping box with suitable nuts, bolts,washers flat iron etc comprising of the followings:- (a) MCB, 6 to 32 Amps, SP (10 KA) (B serires)-01 No.
Taking down old U/S DB and M&L for sheet metal enclosures for DB 2 way with 240 amp rated busbar of 240 V complete all as specified and directed by Engineer-in-charge.
Taking down old U/S DB and S & F in repair Distribution Board made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SP 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified and directed by Engineer-in-charge. [Note : The cost of removing old box and making good of surface i.e. brick work, plastering etc shall be included in quoted rate]
Taking down old U/S DB and S & F in repair vertical Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 protection surface mounting TPN 4 way, 440 volts with bus bar rating 200 Amps, dust and privision MCCB’s 63 Amp 01 No 16 KA fixed and wiring arrangement complete all as specified and directed. Make - Legrand cat part no 607735 or its equivalent as specified in list of make [Note : The cost of removing old box and making good of surface i.e. brick work, plastering etc is to be included in quated rate]
Taking down old U/S MCB and S & F in replacement of MCB 6 to 32 Amps capacity, B Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed.
S&F 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as directed of comprising of the following
Taking down old U/S MCB and Supply and fixing MCB SPN , 40 Amps, 240 Volts complete all as specified and directed by Engineer-in-charge.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed
Supply and fix baton intergrated LED channel 1 x 20 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed
Supply and fixing Wall mounting fan , steel body AC single phase, 230 volt of size 450 mm Industrial Wall Air Circulator Fans 1400 RPM Heavy duty oscillation type propeller fan available with impeller consisting of 3 blades in pedestal & bracket type (wall & column mounted) and steel cover complere fixing arrangements on the wall with nuts and bolts making the good surfces all as specifed and directed at site. [Note:- (a) Taking down U/S Wall munting Fan of any capacity will be deposited in MES store yard.]
Supply and fixing GI vantilatted channel type cable tray single compartment of size 250 mm x 38 mm for carrying of LT cable of suitable size fixing on wall along with all necessary fixing accessories ( bracket, nut bolts, washer, fastner) all as spcified and directed by Engineer-in-Charge.
Supply and fixing outdoor unit of split type AC 2 TR cap having 5 star rating complete with all accessories such as hermetically sealed compressor, condenser unit, capacitor, relays, fan motor, stand etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
Supply and fixing indoor unit of split type AC 2.0 TR cap having 5 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one complete all as specified and directed.
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete.
Supply and lay PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete.
Supply & Supply bracket made out of stanless steel for fixing of split AC set of two all as specified & directed by EIC.
SHRI SAI ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .