Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹18.9 LAccepted-AOC | 1 | Accepted-AOC Work allotted | |
| 2 | 2₹19.4 L+₹48,783.73 (2.58%)Rejected-Finance 32 JUROLA PATLI RAILWAY STATION FARRIKHINAGAR GURUGRAM | GURUGRAM | GURUGRAM | HARYANA | 2 | Rejected-Finance Not lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not ok | |
| 4 | Rejected-Technical | - | Rejected-Technical Not ok |
Tender Value
₹21.1 L
EMD Value
₹42,000
Closing Date
17 Feb 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Provin Divisn PWD BandR Jind
Executive Engineer Provin Divisn PWD BandR Jind
Construction of Library at Safidon in Jind Distt.
2022_HRY_207795_1
PWD/Jind/Construction of Library at Safidon
Open Tender
Civil Works
Works
182 days
Jind
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹42,000
Yes
Executive Engineer Provin Divisn PWD BandR Jind
28 Mar 2022
11 Feb 2022
18 Feb 2022
11 Feb 2022
17 Feb 2022
11 Feb 2022
15 Feb 2022
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. All kinds of soil (HSR 4.12.1)
Filling available excavated earth (excluding rock) in trenches, cum plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m..(HSR 4.32)
Excavating, supplying and filling of local earth (including royalty) cum by mechanical transport up to a lead of 8 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.(HSR 4.33)
Cement Concrete 1:8:16 with stone aggregate 40 mm size in cum foundation and plinth.(HSR 10.100.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: (HSR 6.1.6) 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement-All work up to plinth level : (HSR 6.14.1) 1 : 1. 5: 3 ( 1 cement : 1. 5 coarse sand (zone-Ill): 3 cum graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: (HSR 7.21.2) Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying damp-proof course with cement concrete 1 :2:4 (1 cement : 2 coarse sand (zone-Ill): 4 graded stone aggregate 12.5mm nominal size) (HSR 6.8.1) 50 mm thick
Providing and laying of base course of floors consisting of 100 mm thick cement 1 :8: 16 and 100 mm sand or stone filling. (HSR 10.1)
Providing and laying of conglomerate floor 50mm thick cement concrete topping 1 :2:4 (HSR 10.7)
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.33.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt clay non-modular bricks of class designation 7 .5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : (HSR 7.22.2) Cement mortar 1:6 (1 cement : 6 coarse sand) First Storey
Second Storey
Brick work with clay Flyash non-modular brick of class designation 7.5 in superstructure above plinth level up to floor four level in : (HSR 7.46.2) Cement mortar 1:6 (1 cement : 6 coarse sand) First Storey
Second Storey
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor four level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) (HSR 6.15.1)
Reinforced cement concrete work in beams, suspended floors roofs having slope up to 15 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). (HSR 6.16)
10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1: 1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1 :3 (1 cement: 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: (HSR 9.11.1) With common burnt clay non-modular brick tile of class designation 10
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1 :3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. (HSR 9.18)
Providing gola 75x75 mm in cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1 :3 (1 cement : 3 fine sand) as per standard design : (HSR 9.17.1) In 75x75 mm deep chase
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (HSR 9.57.3) 150 mm diameter
75 mm diameter (HSR 9.57.1)
110 mm diameter (HSR 9.57.2)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 1 O mm gap for thermal expansion. (HSR 9.58.5.3) Bend 87.5". 150 mm bend
75 mm diameter bend (HSR 9.58.5.1)
110 mm diameter bend (HSR 9.58.5.2)
Providing and fixing of Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 ( 1 cement : 4 coarse sand) : (HSR 10.37.1) 25 mm thick
Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab. (HSR 10.42)
Providing and fixing of Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (HSR 10.38)
Plastering on walls12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) : (HSR 11.5.3) First Storey
Second Storey
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.63.2) Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1 :4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. (HSR 10.63.2) Size of Tile 600x600 mm
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1 :4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc.,complete. (HSR 10.59)
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (HSR 10.58)
Plastering on wall 12 mm cement plaster of mix 1 :6 (1 cement: 6 fine sand) : (HSR 11.5.4)
Plastering on walls 15 mm cement plaster on the rough side of single or half brick wall of mix 1 :6 (1 cement: 6 fine sand) : (HSR 11.6.2)
Plastering on walls 10 mm thick cement plaster 1 :3 (1 cement: 3 fine sand) (HSR 11.4.2)
Preparation of ply wood surface for painting including sand papering the surface and applying filling with approved quality filler consisting of white lead, linseed oil, varnish and chalk mitti including finishing the surface to required finish complete. (HSR 11.76)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Painting two coats excluding priming coat with synthetic enamel paint in all shades on new wood work or metallic or plastered or concrete surfaces to give an even shade. (HSR 11.78)
Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat) (HSR 11.68.4)
Painting over the wooden/metal surface with aluminium paint of approved brand and manufacture to give an even shade. (HSR 11.84.1) Two or more coats on new work
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: (HSR 11.64.1) New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gmnitre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. (HSR 11.98.1) New work (Two or more coats applied@ 1.43 litre/ 10 sqm Over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58)
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, including ISi marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engine er-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately} (HSR 12.7.2.1) Kiln seasoned and chemically treated Hollock wood. 35 mm thick shutters
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws: 30 mm thick shutters. (HSR 12.19.2.1.2) Kiln seasoned and chemically treated Hollock wood
Providing and fixing ISi marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (HSR 12.37.1) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (HSR 13.29.2) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level. Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, over1aps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. (HSR 6.34.6) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Float glass panel. (HSR 12.9.7.1) 4 mm thick glass panel (weight not less than sqm 10kg/sqm).
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B (HSR 13.3.1.1) Fixing with adjustable lugs with split end tail to each jamb
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 2.0 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 2.00 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile C (HSR 13.3.2.1) Fixing with adjustable lugs with split end tail to each jamb
P.H. Work Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: All Kinds of soil. Pipes, cables etc, not exceeding 80 mm dia. (HSR 4.16.1.1)
Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia (HSR 4.16.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size) (HSR 6.1.7)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work· Exposed on wall :- 25mm (HSR 22.88.3)
40mm (HSR 22.88.5)
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm (HSR 22.89.2)
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. (HSR 22.90)
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20mm (HSR 22.94.2)
25mm (HSR 22.94.3)
40mm (HSR 22.94.5)
Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (HSR 22.95)
Drilling and tapping cast iron pipe line of all diameters and screwing in ferrule and connections. Ferrule size 40 mm (HSR 20.24.6)
Cutting holes upto 23 cm square through brick work in mud walls for pipes and making good including repointing replastering and finishing according to existing finish where required. 11.43 cm thickness of walls (HSR 20.25.1)
22.86 cm thickness of walls (HSR 20.25.2)
Providing and fixing Gun Metal Gate valve with CI wheel of approved qualtity screwed end 25mm internal diameter (HSR 22.98.1)
20mm internal diameter (HSR 22.98.2)
40mm internal diameter (HSR 22.98.4)
Bailing out water from the trenches for making new connections in fully charged pipe lines including cleaning, trimming and dressing the trenches to correct alignment and grade as required by the Engineer-in-charge. Size of the main with which connection is to be made (a) Upto 200mm I/d (HSR 20.49.1)
Constructing brick masonry inspection chamber sizes as given below upto 0.60 meters average depth in cement mortar 1:5 lime concrete with 40 percent lime mortar 2:3 in foundation cement concrete 1:2:4 benching 12mm thick cement plaster 1:2 with a floating coat of 1 mm thick of neat cement RCC 1:2:4 slab 100mm thick/C.C. topping 50mm thick with 455 mm x 455 mm / 455 mm x 610mm inside light duty C.I inspection chamber cover and frame weight as per I.S.I specification painted with 3 coats of black bitumastic superior paint complete as per standard design. Size 450mm x450mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping (HSR 21.84.1)
Size 600mm x900mm inside (with 455mmx455mm cover and frame light duty single seal weighing 20 kg with C.C topping RCC slab (HSR 21.84.3)
Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1: 1 (1 cement : 1 fine sand) including testing of joints etc. complete: 100 mm i/d (HSR 22.163.1)
Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design. 100 mm dia meter S.W pipe (HSR 22.164.1)
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White vitreous chinaware Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (HSR 22.22.1)
Providing and fixing white vitreous chinaware pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinaware flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (HSR 22.24.1)
Providing and fixing 32 mm diameter Gl. extension pipe for Indian type Water Closet suite complete with accessories(as approved by the Engineer -in-charge) (HSR 22.44)
Providing and fixing white vitreous chinaware flat back half stall urinal of size 580x380x350 mm with white PVC flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern (HSR 22.26.3)
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. Size 450mmx300mm (HSR 22.221.1)
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (HSR 22.119.2)
Constructing brick masonry road gully chamber 110x50x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm precast R.C.C. horizontal grating with frame and vertical grating complete as per standard design : With common burnt clay non-modular bricks of class designation 7.5 (HSR 22.207.1)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : (1) 15 mm nominal bore. (HSR 22.104.1).
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore (HSR 22.107.1)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (HSR 22.181) NOTE:- If the agency does not fill/quote the rates of any item, then it will be considered as nil and the same item will be executed by the agency free of cost & it will be contingent to work. The agency have to give an undertaking on account of this, otherwise earnest money will be forfeited, in addition to this, he will be blacklisted.
SATISH KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .