Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC KHAPRAIL BAZAR PO NEW CHAMTA DIST DARJEELING WEST BENGAL PIN 734 009 | DARJEELING | DARJEELING | WEST BENGAL | 734009 | L1 | Accepted-AOC Successful Bidder | |
| 2 | L2₹37.4 L+₹1.9 L (5.49%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful Bidder | |
| 3 | L3₹39.4 L+₹3.9 L (11.1%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful Bidder |
| Sl No | Description | Qty | Unit | SRI A B SEN L3 | DEEP ENTERPRISE L2 | D K SARKAR L1 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. | 185 | Sqm | 68 ₹12,580 | 65 ₹12,025 | 58 ₹10,730 Lowest |
| 2.00 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surface built in cement mortar 1:4 surface finished even and fair without using extra cement complete all as specified and directed.
Note: Water proofing compound shall be measured and paid separately as supply only. | 185 | Sqm | 590 ₹1,09,150 | 490 ₹90,650 | 448 ₹82,880 Lowest |
| 3.00 | M&L for preparation of new plastered surface of any description on walls & applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS: 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces, over a coat of primer complete all as specified and directed. | 185 | Sqm | 272 ₹50,320 Lowest | 279 ₹51,615 | 276 ₹51,060 |
| 4.00 | Supply only integral water proofing compound ISI marked complete all as specified and directed. | 40 | Kg | 50 ₹2,000 Lowest | 61 ₹2,440 | 56 ₹2,240 |
| 5.00 | Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified and directed. | 68 | Sqm | 27 ₹1,836 Lowest | 38 ₹2,584 | 30 ₹2,040 |
| 6.00 | M&L for 4-6 mm thick non asbestos fibre cement building boards fixed or laid to GI with screws and Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, hangers 6 mm dia, G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified etc applying two coats of oil bound distempering over a coat of chalk whitening including preparation of new surface on ceiling complete all as specified and directed by Engineer-in-charge. | 68 | Sqm | 1,600 ₹1,08,800 | 1,620 ₹1,10,160 | 1,525 ₹1,03,700 Lowest |
| 7.00 | M&L for complete removal of existing treatment and applying 3 mm thick Birla wall care putty and applying two coat of oil bound distemper white or tinted over a coat of primer on walls etc complete all as specified and directed. | 135 | Sqm | 28 ₹3,780 Lowest | 30 ₹4,050 | 125 ₹16,875 |
| 8.00 | Hacking out old broken glass any thickness or size from wooden or metal frames glazed with putty or beads complete all as specified and directed. | 25 | Sqm | 92 ₹2,300 Lowest | 105 ₹2,625 | 100 ₹2,500 |
| 9.00 | M&L for plain sheet glass pane 3 mm thick ordinary quality and glazing with oil putty or beads in square n.exc 0.5 sqm each pane complete all as specified and directed. | 25 | Sqm | 750 ₹18,750 Lowest | 850 ₹21,250 | 825 ₹20,625 |
| 10.00 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed. | 119.5 | Sqm | 80 ₹9,560 Lowest | 100 ₹11,950 | 88 ₹10,516 |
Tender Value
₹34.1 L
EMD Value
₹68,200
Closing Date
8 Jul 2025, 6:00 pmClosed
GE AF BAGDOGRA
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
ADDN/ ALTN OF DHOBI GHAT AND ASSOCIATED WORKS AT AFS KURSEONG UNDER GE (AF) BAGDOGRA
2025_MES_701755_2
8614/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Kurseong AF Stn
As per NIT
10 documents required · 10 mandatory
₹500
GE AF BAGDOGRA
₹68,200
Yes
14 Aug 2025
17 Jun 2025
10 Jul 2025
17 Jun 2025
8 Jul 2025
24 Jun 2025
Amount
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surface built in cement mortar 1:4 surface finished even and fair without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately as supply only.
M&L for preparation of new plastered surface of any description on walls & applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS: 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces, over a coat of primer complete all as specified and directed.
Supply only integral water proofing compound ISI marked complete all as specified and directed.
Dismantling wall and ceiling board fibre, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified and directed.
M&L for 4-6 mm thick non asbestos fibre cement building boards fixed or laid to GI with screws and Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (n.exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, hangers 6 mm dia, G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified etc applying two coats of oil bound distempering over a coat of chalk whitening including preparation of new surface on ceiling complete all as specified and directed by Engineer-in-charge.
M&L for complete removal of existing treatment and applying 3 mm thick Birla wall care putty and applying two coat of oil bound distemper white or tinted over a coat of primer on walls etc complete all as specified and directed.
Hacking out old broken glass any thickness or size from wooden or metal frames glazed with putty or beads complete all as specified and directed.
M&L for plain sheet glass pane 3 mm thick ordinary quality and glazing with oil putty or beads in square n.exc 0.5 sqm each pane complete all as specified and directed.
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L for joint free non-skid ceramic coloured tile, 7 to 8mm thick, grade BII matt superior finish, first quality, area of each tile exc 0.18 sqm but n.exc 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic coloured tile in vertical surface 350mm x 250mm x 7mm/ 450mm x 350mm x 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over backing coat 10mm thick cement mortar in 1:4 complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and directed.
Taking down chowkats but with shutters (without taking of shutters from the frames) area exc 1.5 sqm and n.exc 4 sqm each and removing from the site complete all as specified and directed.
M&L for second class hardwood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for second class hardwood plain framed factory made panelled shutters 35mm thick (two number of layer) with panel veneered particles board medium density with commercial face veneers to both faces complete all as specified and directed.
M&L for preparation new wooden surface of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or offering credit as per schedule of credit complete all as specified and directed.
M&L for 25 mm dia CPVC pipe with SDR 13.5 pipe and plain SDR 11 with all fitting & fixed complete to walls or ceiling or laid in floors complete all as specified and directed.
Demolition of cement concrete in any description & in any position not specially provided for complete all as specified and directed.
M&L for 75 mm thick PCC, 1:3:6, type C1 (using 20 mm graded stone aggregate) as in plinth protection laid in alternative bays finished even and fair without using extra cement complete all as specified and directed.
M&L for preparation of old painted wooden or wooden based surface of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wooden or wooden based surface of any description under 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of brickwork/stone masonry built in CM including all quoins, arches, pillars etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed.
M&L for brick work with fly ash bricks, old size brick, straight or curved on plan to exc 6 m mean radius built in CM 1:6 without using extra cement complete all as specified and directed.
M&L for 1.25 mm thick steel rolling shutters with out ball bearing as specified including top cover, and choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull but gear operated type and safety lever locks and ball bearing complete all as specified and directed.
Supplying, installation, testing & commissioning washer extractor machine, minimum 30 Kg capacity per charge, electric heated, front loading open pocket, heavy duty, high spin suspension with hydraulic cushions, full stainless steel cabinet, single motor variable frequency drive automatic soap dispenser complete all as specified and directed. Make: Model No AWXE 30 of Fab Care or its equivalent in IFB or LG.
Supplying, installation, testing & commissioning drying tumbler machine, minimum 30 Kg capacity per charge, outer GI, inner basket of stainless steel, electric heated, auto reverse, auto timed, auto temp control with control panel 1.5 KW, complete all as specified and directed. Make: Model No DTE 30 of Fab Care or its equivalent in IFB or LG.
Supplying, installation, testing & commissioning electric boiler 6 KW fully automatic and providing all electrical connections complete all as specified and directed. Make: Model No FEB 06 of Fab Care or its equivalent in IFB or LG.
S&F vacuum steam ironing machine of size 4" X 2.5" with all fitting, industrial steam iron, iron mat, aluminium shoe, solenoid valve complete all as specified and directed. Make: Model FIB-42 of Make Fab Care or its equivalent in IFB or LG.
S&F dry linen trolley (cage type) 50 Kg capacity formed out of stainless steel tubes & bars, electro treated, foldable front, fitted with 4 No. swivelling type ball bearing wheels complete all as specified and directed. Make: Model No TRW 50 of Fab Care or its equivalent in IFB or LG.
S&F wet linen trolley (box type) 50 Kg capacity, formed out of stainless steel tubes & bars, electro treated, fitted with 4 No. swivelling type ball bearing wheels complete all as specified and directed. Make: Model No WRT 50 of Fab Care or its equivalent in IFB or LG.
M&L for earthing with galvanised earth plate electrode 600x600x6.0mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the plate not less than 1.50 m below ground level, connected with and including galvanised earth strip of size 25x4.0mm by means of bolts, nuts, check nuts and washers of GI or steel and connected earthing testing point/ Bus-bar with GI 40mm bore light grade protection pipe, earth plate surrounded by a packed thickness of charcoal or coke dust mixed with common salt in alternate layers of n.exc 150mm thick, PCC pit in cement concrete, 1:3:6 (using 20mm graded stone aggregate) and pre-cast RCC cover slab of size 450x450x50mm in cement concrete 1:2:4 (using 20mm graded stone aggregate) reinforced with 10mm dia TMT bars @ 100mm centre to centre in both ways, GI wire mesh, PGI funnel with GI watering pipe 20 mm bore medium grade including necessary excavation in soft/loose soil, returning, filling in and removal of surplus spoil upto a distance of 50 m and all as shown in electrical plate No. 3 of MES schedule Part-I, testing on completion including taking down/out unserviceable earthing of any description complete all as specified and directed. Note: All joints should be joined by exothermic welding or brazing.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete along with fittings such as switches, sockets, ceiling rose, lamp holder, tube light fittings and making good disturbed surfaces on walls etc. complete all as specified and directed.
M&L for point wiring with 1.5 sqmm PVC insulated unsheathed multistranded copper cable of FRLSH grade with one run of 1.5 sqmm PVC insulated copper cable as earth continuity drawn in surface PVC casing caping not less than 20 mm width with pressed steel in concealed MS box duly including covered with 3 mm thick hylem sheets for mounting switches/ sockets, accessories such as spacers, saddles, junction boxes for one light/ fan point/ bell point/ 5 amp socket controlled by one switch complete all as specified and directed.
All as per item No 37.00 above, but one socket outlet, three pin, 5/6 Amp on the same board with other switches complete.
All as per item No 37.00 here-in-before, but using 2.5 sqmm single core copper conductor cable of multistrand FRLSH grade PVC insulated unsheathed 1100 volt grade for 16 Amps socket combination point including running of 2.5 sqmm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to common earth dolly for one 6 pin multi socket outlet, 16 Amps, independent complete all as specified and directed.
All as per item No 37.00 here-in-before, but using 4 sqmm single core copper conductor cable of multistrand FRLSH grade PVC insulated unsheathed 1100 volt grade for 16 Amps socket combination point including running of 4 sqmm copper conductor FRLSH PVC wire as earth continuity conductor along with wiring and connecting to common earth dolly for one 6 pin multi socket outlet, 16 Amps, independent complete all as specified and directed.
Taking down carefully sub main wiring including batten/ conduit by unscrewing from wall, ceiling and making good surfaces to match with original status complete all as specified and directed.
M&L for sub main wiring with four single core PVC insulated unsheathed stranded copper conductor of 16 sqmm (nominal area) FRLSH drawing through PVC cashing caping and one 16 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade FRLSH for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. Note: 5 runs of 16 sqmm and 1 run of casing caping will be measured as one unit i.e RM.
M&L for sub main wiring with four single core PVC insulated unsheathed stranded copper conductor of 10 sqmm (nominal area) FRLSH drawing through PVC cashing caping and one 10 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade FRLSH for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. Note: 5 runs of 10 sqmm and 1 run of casing caping will be measured as one unit i.e RM.
M&L for sub main wiring with four single core PVC insulated unsheathed stranded copper conductor of 6 sqmm (nominal area) FRLSH drawing through PVC cashing caping and one 6 sqmm stranded copper conductor cable PVC insulated and unsheathed (green colour) 1100 volts grade FRLSH for earth continuity conductor and connecting with main earth dolly complete all as specified and directed. Note: 5 runs of 6 sqmm and 1 run of casing caping will be measured as one unit i.e RM.
S&F ceiling rose surface backlite 3 terminals 65X50mm, 230V, including PVC Box of size 3"X3" round type complete all as specified and directed.
S&F switch piano, flush type, single pole, one way, 6 Amp complete all as specified and directed.
M&L for socket outlet, 3 pin, 6 Amps, flush type, 230V complete all as specified and directed.
S&F switch socket combination 6 A, 2 in 1 type complete all as specified and directed.
S&F switch socket combination flush type, 6A/16A, 5 in 1 complete all as specified and directed.
M&L for light fitting 1x20 W, 220 V, retrieved from item No 50, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note: Rate is inclusive of flexible copper cable.
M&L for fixing only light fitting 1x9 W, 220 V, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Note: Rate is inclusive of flexible copper cable.
S&F in replacement of LED building security light 35 W, 230 V, AC, outdoor type with high pressure die aluminium housing and heat resistance complete with driver, lamp bracket with impact resistance IK 08 and corrosion resistance including thermal management in multiple optics complete with IP 66 protection, lumen output 4200 complete having 40/32 mm dia GI pipe having 1.5 m length complete all as specified and directed by Engineer-in-charge.
Taking down carefully old unserviceable MCB DBs with MCBs any type by unscrewing from wall, ceiling and making good surfaces to match with original status complete all as specified and directed.
S&F MCB DB, 4 way, SPN with 200 A rated bus bar, 240 V, single door complete all as specified and directed. Make: L & T/Schneider/ABB.
S&F factory made vertical distribution board sheet metal enclosure 8 way, VTPN, 415 Volt, metal door, IP-54, IK-09 protected with 250 Amp rated phase/neutral/earth bus-bar, having facility for MCCB incoming up to 250 Amp and MCB outgoing, fixed flush with wall inside the niches or outside on wall surface and connecting up including taking down/out unserviceable distribution board of any description and making good disturbed surfaces of walls with cement mortar 1:3 and providing surface treatment (white washing/ distempering/ painting) wherever required to match the existing finishes complete all as specified and directed. Make: L&T Cat No DBVTH00854 or its equivalent in Schneider or Legrand.
S&F MCB SP 6 to 32 Amps, 240 Volts, 'C' curve, 10 KA complete all as specified and directed.
S&F MCB FP/TPN, 16-32 Amps, 'C' series, 415 Volts, 10 KA complete all as specified and directed.
S&F MCB FP, 63 Amps, 'C' series, 415 Volts, 10 KA complete all as specified and directed.
Supply & replace MCCB, 160 Amps, 36 KA, 4 pole, 415 Volts, 50 HZ type complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below ground level connected with galvanised earth wire 4 mm dia by means of bolts nuts check nuts and washers of galvanised iron to earth test point all as specified or indicated including necessary excavation and earth work any type of soil PCC (1:3:6) watering funnel, GI tubing 20 mm for watering all as shown in electrical plate No 5 of SSR part 1 (2009) complete all as specified and directed.
Excavation in trenches n.exc 1.5 m in wide and n.exc 1.5 m in depth for taking out or laying of under ground cable/pole in hard dense soil complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers, n.exc 25 cm thick in soil complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 m and deposited at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for HDPE double wall corrugated duct pipe of size 110 mm OD and 95 mm ID for cable protection laid in trench complete all as specified and directed by Engineer-in-charge.
M&L for cutting the existing road/PCC/drain for taking out/ laying of underground cable including necessary earthwork excavation and making good to match with the existing surface with 100mm thick PCC, 1:3:6, type C1 (using 20 mm graded stone aggregate) complete all as specified and directed.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete all as specified and directed.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
DEEP ENTERPRISE (BID ID -3339717)
SRI A B SEN (BID ID -3338792)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .