Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹7.7 L
Closing Date
27 Jul 2021, 4:00 pmClosed
Er Pawan Tickoo
Executive Engineer PWD RandB Electric Div Jammu
please refer BOQ
2021_PWDJK_131453_1
e-NIT No.EDJ/69 of 2021-22 Dated 20-07-2021
Open Tender
Electrical Works
Item Rate
District Development Council Udhampur
please refer to NIT
2 documents required · 2 mandatory
₹0
Exempted
29 Jul 2021
20 Jul 2021
28 Jul 2021
21 Jul 2021
27 Jul 2021
21 Jul 2021
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed conduit as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surface/ recessed conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1 x 1.5 Sq.mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Single Pole and Neutral
Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing of L.T switch gear power control panel floor/Wall mounted Indoor type totally enclosed, compartmentalized, cubical made of 2mm thick sheet duly powder coated free from dents, dust uneven surfaces and vermin proof (as per technical specifications suitable for 415 volts 3 phase 4 wire 50 HZ AC supply complete with hinged doors having looking arrangment with provision of space for MCCB. COS, Bus Bar etc as required. The job includes interconnections testing, commissioning and providing earthing connection to panel. (Design of panel has to take from XEN/AEE. The size of panel can be change as per required design.).
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
MCCB- 125 Amp- 36 KA- FP ICU=ICS=100%
Supplying and fixing of following rating 240/415 Volt's "C" Series miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning. (Above 32 Amp.).
SPN 63 Amp.
TPN 63 Amp
Supplying installation testing and commissioning of XLPE insulated and PVC sheathed / power cable of 1.1 KV grade of following size in ground.cable tray as per site conditions as required.
50 sq. mm x 3.5 core Armoured.
Supplying and fixing of Electrical items.
Round Sheet
Fan Sheet
Angel / Batten Holders
9 watt LED Bulb
12 watt LED Bulb
Fan Regulator
Supplying and fixing of 20 watt LED 4 feet long tube light batten type .
Supplying and fixing of Musical Bell including making complete connections etc. as required. ( Make as per annexure enclosed).
Supplying and fixing of gate light 8" globe type along-with LED bulb 15 watt.
Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply.
Ceiling fan 1200 mm sweep alongwith rod upto 1'-6" long
Exhaust fan 300 mm
Supplying and fixing of (70 + 5) watt LED Street Light complete with M.S/ GI pipe bracket duly embeded along the parapet /wall including complete connections as required.
Supplying, installation, testing and commissioning of 1.5 ton Split type AC's (copper) (3 star) Hot and Cold Inverter type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. Indoor unit must be fitted on wall via clamps while outdoor units on MS powder coated wall stand. PVC pipe for drain shall be supplied & fitted complete with accessories such as bends elbows, flexible connection and repairs made to wall whereever required. Warrantee.:- a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation.
Supplying, Installation, Testing & Commissioning of 4 KVA automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:- 2 Years from the date of installation.
Supplying, Installation, Testing & Commissioning of water storage Heater (Geyser) of following capacity.
Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteres 150 AH and trolly (Metallic) of suitable size.
Supplying, Installation, Testing & Commissioning of Water purifier (R.O) system.
K K CONSTRUCTION
Kirti Kumar Contractor
NK RAINA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .