Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 270 ADARSH NAGAR ROORKEE HARIDWAR 247667 | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC Due to lowest bidder | |
| 2 | L2₹24.6 L+₹85,170 (3.58%)Rejected-Finance | L2 | Rejected-Finance Due to not lowest bidder | |
| 3 | L3₹24.7 L+₹94,772.50 (3.99%)Rejected-Finance RIDMALSAR PUROHITAN BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Due to not lowest bidder | |
| 4 | L4₹24.9 L+₹1.1 L (4.65%)Rejected-Finance | L4 | Rejected-Finance Due to not lowest bidder | |
| 5 | L5₹26.9 L+₹3.1 L (13.1%)Rejected-Finance | L5 | Rejected-Finance Due to not lowest bidder |
| Sl No | Description | Qty | Unit | LAKSHMI ASSOCIATES L7 | V.K. Infra Engineering L6 | A.S. CONSTRUCTION COMPANY L1 | ENGINEER CORPORATION OF INDIA L2 | Durga Construction Company L8 | PUNIYA POWER CONSTRUCTION L5 | Anshu electrical and works L9 | G R POWERS L4 | S S CONSTRUCTION COMPANY L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.
Note :-
1. Reapir and maintanace intimated to the contractor or his rep at any time day or night, through complaint slip or telephonically must be rectified by the contractor within 8 Hrs. If contractor fails to rectify the fault with in 8 Hrs a panelty of Rs 200 per day per complaint will be deducted till the fault/complaint is rectified.
2. All Material required for the repair and matainance work considered in the CA will be made available by the contractor with in 3 Hr.
3. Contractor will arrange two teams of electrician and helper inside of the cantonment for rectification of complaints 24/7 Hours through out the contract prrovision.
4. Contractor will deposit at least 90 % of material on immediate acceptance of the contract included in this contract in MES Store and same will be issued based on the complaint cell.
5. All item retrieved from replacement will be deposited to MES store and cost of same shall be included in quoted rate. | 2,085 | Point | 21 ₹43,785 | 2 ₹4,170 Lowest | 2 ₹4,170 Lowest | 100 ₹2,08,500 | 20 ₹41,700 | 65 ₹1,35,525 | 20 ₹41,700 | 98 ₹2,04,330 | 5.5 ₹11,467.5 |
| 2.00 | Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed. | 860 | RM | 21 ₹18,060 | 10 ₹8,600 | 4 ₹3,440 | 50 ₹43,000 | 5 ₹4,300 | 10 ₹8,600 | 30 ₹25,800 | 2 ₹1,720 Lowest | 5 ₹4,300 |
| 3.00 | Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. | 220 | Each | 30 ₹6,600 | 30 ₹6,600 | 5 ₹1,100 Lowest | 100 ₹22,000 | 50 ₹11,000 | 20 ₹4,400 | 40 ₹8,800 | 5 ₹1,100 Lowest | 15 ₹3,300 |
| 4.00 | M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length. | 200 | RM | 246 ₹49,200 | 190 ₹38,000 | 305 ₹61,000 | 200 ₹40,000 | 260 ₹52,000 | 130 ₹26,000 Lowest | 500 ₹1,00,000 | 160 ₹32,000 | 190 ₹38,000 |
| 5.00 | M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge. | 200 | RM | 291 ₹58,200 | 230 ₹46,000 | 325 ₹65,000 | 200 ₹40,000 | 340 ₹68,000 | 200 ₹40,000 | 750 ₹1,50,000 | 160 ₹32,000 Lowest | 325 ₹65,000 |
| 6.00 | M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge. | 100 | RM | 165 ₹16,500 | 150 ₹15,000 | 272 ₹27,200 | 165 ₹16,500 | 210 ₹21,000 | 120 ₹12,000 Lowest | 300 ₹30,000 | 165 ₹16,500 | 155 ₹15,500 |
| 7.00 | M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge. | 200 | RM | 255 ₹51,000 | 180 ₹36,000 | 300 ₹60,000 | 165 ₹33,000 Lowest | 240 ₹48,000 | 200 ₹40,000 | 500 ₹1,00,000 | 165 ₹33,000 Lowest | 261 ₹52,200 |
| 8.00 | S&F MCCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 200 Amps, double door type suitable for MCCB as a incomer and MCBs as out going double door type ,grouted in walls with Fixing arrangemant complete all as specified and directed. Make-Legrand cat No-5077 50 or equivalent in C&S,Havells, bentex making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge . | 20 | Each | 6,500 ₹1,30,000 | 6,000 ₹1,20,000 | 3,500 ₹70,000 Lowest | 8,000 ₹1,60,000 | 5,800 ₹1,16,000 | 8,000 ₹1,60,000 | 10,200 ₹2,04,000 | 6,800 ₹1,36,000 | 4,650 ₹93,000 |
| 9.00 | S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge. | 20 | Each | 2,100 ₹42,000 | 1,700 ₹34,000 | 2,000 ₹40,000 | 1,050 ₹21,000 | 1,800 ₹36,000 | 1,500 ₹30,000 | 2,650 ₹53,000 | 900 ₹18,000 Lowest | 1,100 ₹22,000 |
| 10.00 | S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge . | 20 | Each | 1,650 ₹33,000 | 1,500 ₹30,000 | 1,500 ₹30,000 | 850 ₹17,000 Lowest | 1,400 ₹28,000 | 1,500 ₹30,000 | 2,550 ₹51,000 | 950 ₹19,000 | 940 ₹18,800 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
12 Aug 2025, 6:00 pmClosed
GE (N) BIKANER
GE (N) BIKANER
REPAIR/REPLACEMENT OF INTERNAL WIRING AND OTHER MISC REPAIR WORK AT MD ACCN (LESS COMPREHENSIVE MAINT) UNDER AGE BR-I AT MIL STN BIKANER
2025_MES_720725_1
GE (N) BKN-TOKEN/08/2025-26
Open Tender
Miscellaneous Works
Item Rate
335 days
GE (N) BIKANER
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (N) BIKANER
₹80,000
Yes
18 Sept 2025
16 Jul 2025
19 Aug 2025
16 Jul 2025
12 Aug 2025
31 Jul 2025
Amount
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed. Note :- 1. Reapir and maintanace intimated to the contractor or his rep at any time day or night, through complaint slip or telephonically must be rectified by the contractor within 8 Hrs. If contractor fails to rectify the fault with in 8 Hrs a panelty of Rs 200 per day per complaint will be deducted till the fault/complaint is rectified. 2. All Material required for the repair and matainance work considered in the CA will be made available by the contractor with in 3 Hr. 3. Contractor will arrange two teams of electrician and helper inside of the cantonment for rectification of complaints 24/7 Hours through out the contract prrovision. 4. Contractor will deposit at least 90 % of material on immediate acceptance of the contract included in this contract in MES Store and same will be issued based on the complaint cell. 5. All item retrieved from replacement will be deposited to MES store and cost of same shall be included in quoted rate.
Taking down submain wiring Aluminium/ copper of any size including earth continuity condutor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length.
M & L for submain (single phase) wiring complete with and including 6.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 6 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 6.0 sqmm PVC insulated wire and one run of 6 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through Existing PVC conduit including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge.
M & L for submain (single phase) wiring complete with and including 4.0 sqmm two single core,(FRLSH) fire retardant, PVC insulated and unsheathed multistranded copper conductor cable, 1100 Volts grade, drawn through PVC concealed conduit of suitable size including accessories and fixed on walls and 4 sqmm, fire retardant, PVC insulated, multistranded copper conductor cable for earthing and connected to common earth dolly complete all as specified and as directed by Engr-in-Charge. Note :- (i) Two runs of 4.0 sqmm PVC insulated wire and one run of 4 sqmm wire and one run of PVC conduit shall be measured as one unit length. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge.
S&F MCCB TPN DB,4 way Vertical type,440V,3 phase with rated busbar 200 Amps, double door type suitable for MCCB as a incomer and MCBs as out going double door type ,grouted in walls with Fixing arrangemant complete all as specified and directed. Make-Legrand cat No-5077 50 or equivalent in C&S,Havells, bentex making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge .
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge.
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 8 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge. making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge .
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 4 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.
S & F MCB SPN, 6-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge. Make : ABB/Legrand/C&S
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.Make : ABB/Legrand/C&S
S&F MCCB 63 amps, 4 pole, 415 volts, overload and Short circuit adjutable type breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge. Make : ABB/Legrand/C&S
S&F MCCB 100 amps, 4 pole, 415 volts,overload and Short circuit adjutable type breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge. Make : ABB/Legrand/C&S
S&F MCCB 125amps, 4 pole, 415 volts, overload and Short circuit adjutable type breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge. Make : ABB/Legrand/C&S
S&F MCCB 63 amps, 3 pole, 415 volts,overload and Short circuit adjutable type breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge. Make : ABB/Legrand/C&S
S&F MCCB 100 amps, 3 pole, 415 volts, overload and Short circuit adjutable type breaking capacity 25 KA complete all as specified and as directed by Engr-in-charge. Make : ABB/Legrand/C&S
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.
M & L for Modular point wiring with and including single core FRLSH PVC insulated and unsheathed stranded copper conductor cable of size 1.5 sqmm 1100 volts grade drawn through and including suitable size of PVC concealed conduit with accessories with laminated top cover fixed on MS sunken box for housing of switch, socket, regulator etc complete with and including 1.5 sqmm FRLSH PVC insulated and unsheathed stranded copper conductor cable as earth wire and connected to common earth dolly and making good to the disturbed surfaces of wall, floor, ceiling etc and making good to the disturbed surfaces of wall, floor, ceiling etc to match with exisiting surface complete all as specified and as directed by Engr-in-Charge . Note :- (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed to include for moduar metal flush boxes of requiste module and modular cover plates with frame of requisite module of colour as approved by GE. (a) One Light/fan/ex-fan point controlled by one switch.
(b) one socket point on the same board with other switch complete.
(c) One 3 pin 5 amps socket on independent board.
(d) all as per item No-26 above but with 2.5 sqmm copper wire for 3 pin socket outlet 15 Amp on independent board complete and all as directed by Engr-in-charge.
(e) all as per item No 26 above but but one light point controlled by two 02 way switch board complete and all as directed by Engr-in-charge.
S&F switch Modular type, 6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge. Make-Havells SAP Code AHFSXXW061, Legrand Cat no- 679200, C&S Cat no- CG2011PWNR.
S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge. Make-Havells SAP Code AHFSXXW161, Legrand Cat no- 679209, C&S Cat no- CG20573PWNR.
S&F Bell push Modular type, 6 Amp, 1 module single pole , 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge. Make-Havells SAP Code AHRSBXW061, Legrand Cat no- 679229, C&S Cat no- CG20509PWNR.
M&L socket outlet 3 Pin 6/16 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge. Make-Havells SAP Code AHFKCXW163, Legrand Cat no- 679218, C&S Cat no- CG20352PWNR.
M&L socket outlet 3 Pin 6 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge. Make-Havells SAP Code AHFKPXW063, Legrand Cat no- 679235, C&S Cat no- CG20370PWNR.
Supply and fixing fan step regulator modular type,120W -2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge. Make-Havells SAP Code AHLREFXW005, Legrand Cat no- 679241, C&S Cat no- CG20826PWNR.
S&F in repair modular white cover plate with frame but 1 module complete all as specified and as directed.
S&F IN repair modular white cover plate with frame but 2 module complete all as specified and as directed.
S&F IN repair modular white cover plate with frame but 3 module complete all as specified and as directed.
S&F IN repair modular white cover plate with frame but 4 module complete all as specified and as directed.
S&F IN repair modular white cover plate with frame but 6 module complete all as specified and as directed.
S&F IN repair modular white cover plate with frame but 8 module complete all as specified and as directed.
S&F in repair modular metel flush box but 1,2, module to suit as existing make complete all as specified and as directed Note :- (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) making good to the disturbed surface of wall ,floor,ceiling etc to stretch with existing surface.
S&F in repair modular metel flush box but 3&4 module to suit as existing make complete all as specified and as directed Note :- (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) making good to the disturbed surface of wall ,floor,ceiling etc to stretch with existing surface.
S&F in repair modular metel flush box but 6,8 module to suit as existing make complete all as specified and as directed Note :- (i) Cost of cutting/leaving forming chases for conduits, sinking for modular metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) making good to the disturbed surface of wall ,floor,ceiling etc to stretch with existing surface.
M&L singal pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified & directed by Engr-in-Charge. Make :- ABB/C&S/Legrand
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with LED bulb 9watt
S&F MCCB 40 amps, 4 pole, 415 volts, fixed type breaking capacity 16KA complete all as specified and as directed by Engr-in-charge.
M&L for submain wiring using 4 runs of single core FRLSH PVC insulated, unsheathed stranded copper conductor cable of size 4runs of 10 Sqmm of voltage rating 1100V for three phase & neutral, drawn in and including concealed PVC conduit of dia not less than 32 mm dia with standard acessories, along with two run of FRLSH PVC insulated, unsheathed, stranded copper conductor of size 2x 10 Sqmm as earth continuity conductor all as specified and directed(Note-4 runs of single core FRLS PVC cable 10 sqmm for three phase & neutral with Two run of earth conductor as earth and conduit shall be measured as one unit)and making good the disturbed surface of wall etc complete all as specified and as directed.
Supply & Fixing of sheet metal enclouser TPN 4 way , Double door DB, IP-54 bus bar neutral link earth bar and din rail make MDS with provision of 01 X 63 Amps fouur pole MCB complete all as specified and directed by Engr-in-Charge.Make : L&T/Legrand/ABB
M&L MCB TPN 'C' curve 40 TO 100 Amps 415 Volts complete all as specified and directed by Engr-in-Charge.Make :- L&T/ABB/Legrand
Re-winding of ceiling fan of size 1200 mm sweep with super enameled copper winding wire of gauge as per existing size /No. of turns confirming to IS, including varnishing the motor windings with best quality varnish complete all as specefied and as directed by Engineer in charge. (Make:Milan/Atlas/Chetak)
S&F in replacement of ball bearing of size/No. 6201 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NBC/SKF)
S&F in replacement of ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed by Engineer in charge.(Make: NBC/SKF)
S&F in replacement of brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specefied and as directed by Engineer in charge.
S&F in replacement D Clamp with nuts, bolts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed by Engineer in charge.
S&F condenser 2.5 MFD confirming to IS complete all as specefied and as directed by Engineer in charge.
S&F in replacement of broken bottom cover (bowl) of suitable for ceiling fan of any make and model as per existing size and shape complete all as specefied and as directed by Engineer in charge.
S&F PVC Canopies (Set of two) as required at site and complete all as specefied and as directed by Engineer in charge
ENGINEER CORPORATION OF INDIA (BID ID -3391184)
S S CONSTRUCTION COMPANY (BID ID -3382468)
G R POWERS (BID ID -3391029)
PUNIYA POWER CONSTRUCTION (BID ID -3391618)
V.K. Infra Engineering (BID ID -3384056)
LAKSHMI ASSOCIATES (BID ID -3383156)
Durga Construction Company (BID ID -3382986)
Anshu electrical and works (BID ID -3380306)
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .