Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAdmitted-Finance | ₹1.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹1.8 L (1.66%)Admitted-Finance | ₹1.1 Cr+₹1.8 L (1.66%) | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT QUALIFIED |
| Sl No | Description | Qty | Unit | R.S ASSOCIATES L1 | M/S ALJAN ENGINEERS AND CO L2 |
|---|---|---|---|---|---|
| 1.01 | Disconnection of Transformers from the system,radiators,fans,pipes,bushings, conservator tank and complete wiring | 4 | No. | 95,000 ₹3,80,000 | 4,000 ₹16,000 Lowest |
| 1.02 | Erection of temporary shed for dehydration of transformers. | 4 | No. | 55,000 ₹2,20,000 | 2,000 ₹8,000 Lowest |
| 1.03 | Draining of Oil, Removal of Oil and opening of connectors,dismantling old damaged components and replcement by new on, lifting of top lid of power transformers by way of crane including hire charges and replecement of damaged top lid gasket of transformer/bushing gaskets etc. | 1,35,000 | ltrs. | 8 ₹10,80,000 | 2 ₹2,70,000 Lowest |
| 1.04 | Inspection and testing of transformers including drying/replacement of silica gel,checking of buchloz relay, surge relay temperature sensors/cooling system,measurement of IR values, BD values of transformer oil,cleaning of transformer | 4 | No. | 35,000 ₹1,40,000 | 4,000 ₹16,000 Lowest |
| 1.05 | Cleaning of transformers, Dehydration of transformer including use of vacuum pumps, Filling of drained transformer oil and fresh oil after filtration and obtaining accurate BDV value. | 1,35,000 | ltrs. | 8 ₹10,80,000 | 2.5 ₹3,37,500 Lowest |
| 1.06 | Final erection check inluding connection of LV and HT jumpers,control wiring etc. | 4 | No. | 35,000 ₹1,40,000 | 4,000 ₹16,000 Lowest |
| 1.07 | Supply of fresh transformer oil as per IS:335/193. | 60,000 | ltrs. | 115 ₹69,00,000 Lowest | 157 ₹94,20,000 |
| 1.08 | DGA and PPM of Transformer Oil from accredIted laboratories. | 4 | sample | 40,000 ₹1,60,000 | 4,000 ₹16,000 Lowest |
| 1.09 | Overhauling/Maintenance of 132 KV SF6 Breaker of transformer bank. ( rate is 12% of fresh item as per latest cast data) | 7 | No. | 20,000 ₹1,40,000 | 3,000 ₹21,000 Lowest |
| 1.10 | Overhauling/Maintenance of 220 KV SF6 Breaker of transformer bank. ( Rate is 12% of fresh item as per latest cast data) | 4 | No. | 20,000 ₹80,000 | 6,000 ₹24,000 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
12 Feb 2024, 4:00 pmClosed
Executive Engineer TLMD-III JKPTCL Udhampur
Executive Engineer TLMD-III JKPTCL Udhampur
CAPITAL MAINTENANCE BY WAY OF OVERHAULING OF
2024_PDD_243478_1
TLMD-III/UDH/32 of 2023-24
Open Tender
Electrical Works
Turn-key
60 days
Ramban maitra
AS PER SBD
2 documents required · 2 mandatory
₹2,000
Yes
Executive Engineer TLMD-III JKPTCL Udhampur
₹2.2 L
Yes
O/O Executive Engineer TLMD-III JKPTCL Udhampur
29 Feb 2024
23 Jan 2024
13 Feb 2024
23 Jan 2024
12 Feb 2024
23 Jan 2024
23 Jan 2024 - 12 Feb 2024
31 Jan 2024
Amount
Disconnection of Transformers from the system,radiators,fans,pipes,bushings, conservator tank and complete wiring
Erection of temporary shed for dehydration of transformers.
Draining of Oil, Removal of Oil and opening of connectors,dismantling old damaged components and replcement by new on, lifting of top lid of power transformers by way of crane including hire charges and replecement of damaged top lid gasket of transformer/bushing gaskets etc.
Inspection and testing of transformers including drying/replacement of silica gel,checking of buchloz relay, surge relay temperature sensors/cooling system,measurement of IR values, BD values of transformer oil,cleaning of transformer
Cleaning of transformers, Dehydration of transformer including use of vacuum pumps, Filling of drained transformer oil and fresh oil after filtration and obtaining accurate BDV value.
Final erection check inluding connection of LV and HT jumpers,control wiring etc.
Supply of fresh transformer oil as per IS:335/193.
DGA and PPM of Transformer Oil from accredIted laboratories.
Overhauling/Maintenance of 132 KV SF6 Breaker of transformer bank. ( rate is 12% of fresh item as per latest cast data)
Overhauling/Maintenance of 220 KV SF6 Breaker of transformer bank. ( Rate is 12% of fresh item as per latest cast data)
oil filtration plant
M/S ALJAN ENGINEERS AND CO
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
SBD.pdf
Tender Documents • 1.28 MB
BOQ_713396.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .