Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-Finance | L1 | Accepted-Finance ok | |
| 2 | L2₹8.8 L+₹1.8 L (24.8%)Accepted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L2 | Accepted-Finance ok | |
| 3 | L3₹9.9 L+₹2.9 L (40.5%)Accepted-Finance 12 GURU NANK AUTO MARKET KASHMERE GATE DELHI 110006 | NORTH | DELHI | 110006 | L3 | Accepted-Finance ok |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
30 Apr 2020, 11:15 amClosed
Executive Engineer (EnM) WnS (WEST)
C-2A Block Janakpuri BPS New Delhi-110058
Improvement of Power Factor by P/F of APFC Panel at Various Bps In Inderpuri area and Nariana village.
2020_DJB_190308_16
e-NIT No.02 / EnM (WEST)/ 2020-21
Open Tender
Miscellaneous Works
Works
30 days
C-2A Block Janakpuri BPS New Delhi
Please refer Tender Documents.
3 documents required · 3 mandatory
₹500
DJB Account No. 50448339804
₹20,000
Yes
11 May 2020
23 Apr 2020
30 Apr 2020
23 Apr 2020
30 Apr 2020
23 Apr 2020
Shunt capacitors power 3 phase,415V AC 50Hz MPP type heavy duty in suitable banking as per requirement to maintain power factor Make: Epcos/L&T
Automatic power factor correction relay 415V digital type 8stag Make: L&T/Neptune/Epcos
MCCB of 100Amp. 415V AC 3 phase 50HZ for incomer braking capacity with spreader terminals and handle 36KA Make: L&T/Siemens
MCCB of 63Amp. 415V AC 3 phase 50HZ with spreader Make L&T/Siemens
MCB of 12-32Amp. 415V AC 3 phase 50HZ Make L&T/Siemens
PVC insulated flexible copper wire 16sq mm 1.1KV Make: Kalinga/Havells
Amp. Meter digital type make: AE
Volt meter digital type Make; AE
Power contactor 220V AC 70Amp Make: L&T/Siemens
Power contactor 220V AC 40Amp Make: L&T/Siemens
Power contactor 220V AC 25Amp.Make: L&T/Siemens
Power contactor 220V AC 12Amp.Make: L&T/Siemens
Indicating lights LED type 220V ON & RYB make: siemens/vaishnav
Current transformer100/5 for current measurement make: AE/Advance
Aluminum Main bus-bars, links, bends sets duly sleeved with heat shrinkable sleeve suitable for 100Amp. Current carrying capacity in suitable cross section of electricalgrade55%conductivity
Sensing current transformer of suitable ratio of incomer for current sensing Make; AE/Advance
S/o fabricated A.P.F.C .panel board enclosure in (1400mm X1000mm X350 mm) 2mm CRCA sheet, cubical type, floor mounting dust vermin proof with gas cut bidding ,neutral link terminal block and having chamber as suitable to fix the above mention capacitors banks & switchgears to be fitted in with provision for cable entry & Base frame made out of MS channel as suitable to fix the A.P.F.C. panel .
Installation, commissioning, testing of the capacitor unit across the transformer with cable connection both incoming & out going with thimbling, required hardware & required civil work at site.
Installation of the new APFC panels at site with required hard ware This includes Testing& commissioning of the all installed components in APFC panel and setting of APFC relay to get proper power factor. Testing & commissioning of the APFC panel with relevant IS as follow: - Check equipments specification - Continuity and ear thing -MCCB mechanism and alignment -Meggaring of all equipments for phase to phase, neutral to body, neutral to earth and phase to earth. - All functional tests -Checking for all tightness of nuts and bolts -Setting of APFC relay parameters to achieve target PF -Alignments of doors etc. -interlocking tests
Premier Engineering Company
Agarwala Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .