Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.8 L+₹6.4 L (16.0%)Rejected-AOC NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-AOC Not L1 | |
| 3 | L3₹47.3 L+₹6.9 L (17.1%)Rejected-AOC | L3 | Rejected-AOC Not L1 | |
| 4 | L4₹48.3 L+₹7.9 L (19.7%)Rejected-AOC ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L4 | Rejected-AOC Not L1 | |
| 5 | L5₹48.5 L+₹8.1 L (20.2%)Rejected-AOC | L5 | Rejected-AOC Not L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER BRICHGUNJ
GARRISON ENGINEER BRICHGUNJ PORT BLAIR-744103
REPAIR AND MAINTENANCE OF PROTHRAPUR FILTERATION PLANT PIPE LINES AND CLEANING OF OH TANKS AND UG SUMPS UNDER GE BRICHGUNJ
2022_MES_544098_1
8256A
Open Tender
Civil Works
Works
270 days
GARRISON ENGINEER BRICHGUNJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER BRICHGUNJ
₹80,000
Yes
13 Oct 2022
8 Aug 2022
1 Sept 2022
8 Aug 2022
30 Aug 2022
23 Aug 2022
8 Aug 2022 - 19 Aug 2022
60 days
Amount
Cleaning of service tanks of the capacity as mentioned below on roof top of bldgs upto forth storey after disconnection from inlet and outlet pipe, removing of float valve of service tank and keep aside safely for reuse drain out water through drain plug, cleaning thoroughly to remove all scales and dirt by brushing internal surface, cleaning properly inside with bleaching powder, flushing out with fresh water, re-positioning of tank at same place, re-connecting inlet and outlet pipes, closing of drain plug, re-installation of float valve duly cleaned, writing/ labelling the record of cleaning carried out with white/black bold letter such as "TANK CLEANED ON" _____(date), including removing creepers, vegitation and roots of plants, trees branches on or surrounding of service tank complete all as directed. Note:-(i) Unit rate quoted is deemed to be included for testing of water supply in tank both inlet and outlet flow during next supply hours. (ii) Contractor shall maintain a register for cleaning carried out with date and obtain users signature and remarks if any and this register to be submitted to JE E/M alongwith RAR. (iii) Contractor is liable to rectify any damages to the external finishes of the bldg occured during the cleaning process, i.e. scrubbing and touch up with external paints as existing specifications. Unit rate quoted is deemed too be included the cost of the same. (iv) All sort of petty T&P items such as ladder, safety equipment, nuts, bolts, washers etc. required to accomplish the job shall be provided by the contractor with out any extra cost to dept.
(a) PVC tank of capacity not exceeding 250 litres
(b) PVC tank of capacity exceeding 250 litres but not exceeding 500 litres
(c) PVC tank of capacity exceeding 500 litres but not exceeding 1000 litres
(d) PVC tank of capacity 2000 litres
(e) PVC tank of capacity 5000 litres
(f) PVC tank of capacity 10000 litres
S&F PVC tank cover (top) for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) suitable for 200/250/500/1000/2000 ltrs capacity, after taking out unsv PVC water tank cover complete all as directed by Engineer-in-Charge.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) with tank cover (top) hoisted and fixed in position complete after dismantling and taking down the existing unsv PVC water tank of size 200/250 ltrs capacity from terrace complete all as directed by Engineer-in-Charge.
All as per Item Ser Item No 09.00 here-in-before but of size 500 ltrs capacity
All as per Item Ser Item No 09.00 here-in-before but but of size 1000 ltrs capacity
All as per Item Ser Item No 09.00 here-in-before but but of size 2000 ltrs capacity
M&L for Cleaning of OH Reservoir upto 30 mtr staging, semi UG Sumps, UG Sumps, Storage tanks, Fountain of the following capacities once in 06 months intervel or if any water contaminated as per the direction of Engr-in-Charge as per the followings stages of cleaning process complete all as specified and directed :- (i) De-watering by high pressure submersible pump all complete (ii) Removal of sludge/mud/slit/sand by vaccum operated pumpset, all dirty particles by industrials wet vacuum cleaner leaving the tank physically cleaned and disposal out side the installation primeses (iii) Cleaning of walls, floors, ceiling etc by high pressure jet pump 120 bar pressure all complete (iv) Applying one coat of white wash internal surfaces. (v) Replace nylon net for vent pipes & man hole cover (vi) Writing letter in bold with white paint on black colour back ground such as Sump name, capacity, cleaned on Date & Due on Date etc Note : The contractor shall arrange mobile generator for operation of dewatering by high pressure submersible pump (or) Diesel driven high pressure pump and the unit quoted rate is inclusive of rent/hiring charges complete. Note (a) Dewatering pump of suitable capacity shall be arranged by the contractor. (b) Material removed from the UG sumps/OHT's shall be deposited off at a distance of 50 mtrs away from the installation primeses. (c) UG sumps/OHT's shall be made available for cleaning for a period of 08 hours to avoid the disturbance of water supply to the connected area. (d) Contractor has to arrange sufficient labour/T&P to complete the job with in the given period only (e) In case of any accident during the work in progress the contractor will be fully responsible to give necessary medical aids and also compensation to worker under compensation act 1923
Semi under ground sump (Raw Water) of capacity 75000 gallons at Prothrapur filtration plant
Under ground sump (Fresh Water) of capacity 75000 gallons at Prothrapur filtration plant
Underground sump (Fresh Water) of capacity 2 lakh gallons at Prothapur Filtration Plant
Ground level clarifloculator sump of capacity 4.5 lakh gallons including flush mixing chamber, RCC water channel at Prothrapur filtration plant
Suction Gallary of capacity 7000 Gallon at Prothrapur filtration plant
Filter Bed of capacity 7000 Gallon at Prothrapur filtration plant
Over head tank of capacity 2.25 lakh litres
Semi Underground sump of capacity 2.65 lakh litres at STP 750 KLD
Over head tank of capacity 3 lakh litres at MAP OHT
Over head tank of capacity 2.25 lakh litres MAP OHT
Semi Underground sump of capacity 03 lakh litres at MAP PH
Semi Underground sump of capacity 04 lakh litres at MES colony
Underground sump of capacity 88000 litres at MES colony
Semi Underground sump of capacity 60000 gallons at PARA 11 PH
Semi underground sump of capacity 75000 litres at Bde Swimming pool
Underground balancing tank of capacity 01 lakh at Bde Swimming pool
SWT of capacity 01 Lakh littres at Bde Magzine Guard.
Underground sump of capacity 150000 litres at fire fighting sump at Likabali
Storage tank 50000 ltrs capacity at Fire fighting sump at Likabali.
Overhead Tank Reservoir of capacity 1 lakh litres at TA Bn.
Fountain at various locations up to capacity 10000 Ltrs .
Storage tank Sump 75000 ltrs capacity at Bde Inf Unit.
Smi underground sump of capacity 400000 litres RWH Ranjit Vihar
Semi underground sump of capacity 200000 litres RWH Ranjit Vihar
Overhead Tank Reservoir of capacity 10000 gallon at PROTHRAPUR PH.
Collect the sample of water of 5 litres each from user end, after cleaning of UG Sumps or OH Tanks or RCC/ PVC tanks and sending it same day at Govt approved lab for testing of water as per IS 10500 in a cleaned container and necessary reports will be submitted to GE Birchgunj complete all as directed by Engr in Charge.
Excavation and earth work in mud/hard soil etc by using machinary/labour to any length to attend pipe line breakdown as per site conditions and forming bund with excavated soil to avoid water entering into the working area including pumping/bailing out water by using portable diesel engine driven pump set including the following complete all as specified and as directed :- (i) Cutting of unserviceable CI/DI pipe of size 300/400/500 mm dia after thorough inspection for the damage including bailing out water using portable pump set. (ii) Taking out damaged/ unserviceable pipe after removing from rubber tyton joint/burning out lead joints at both ends & replacing new 300/400/500 mm dia DI pipe line in lieu of existing in to trenches using machinary / labour as required complete all as directed by Engineer-in-Charge. (iii) Transportation of DI pipe / fittings of size 300/400/500 mm dia from Prothrapur Pump house to work site and cutting the pipe to required length to suit site conditions. (iv) Jointing pipe by using rubber tyton rings 300/400/500mm dia to the corresponding socket and spigot ends of the existing pipe line after aligning the pipe line as per site condition, inserting the CI collar of size 300/400/500 mm dia, complete all as directed by Engineer-in-Charge. (v) Making run lead joints in CI collar 300/400/500 mm dia or in any other specials of any size and any type, caulking of joints and testing for leakages if any, complete all as specified and as directed by Engineer-in-Charge. (vi) Returning filling in including removal of surplus mud/excavated materials with the help of earthmoving machinery (Hitachi), complete all as specified and as directed by Engineer-in-Charge. Note :- (a) DI pipe and fittings of size 300/400/500 mm dia shall be measured and paid separately under relevant item here in after as supply only (b) Cost of tools & plants as required for work & transportation is deemed to be included in the unit rate quoted. (c) The Contractor shall take due care while executing the work (i.e., sepecially taking out old existing pipe line and laying new pipe line). Any damage to the existing services (i.e electrical cable,telephone cable,water supply pipe line and road etc) during execution of work shall be repaired immediatly and cost of the same is deemed to be included in the quoted rates)
Supply only 500 mm bore ductile iron pressure pipes, class "K-9" with socket and spigot ends conforming to IS - 8329 in standard lengths suitable for push-on rubber gasket jointing with inside mortar lining and black bitumen external coating complete all as specified and as directed. Make: Electro steel / Tata / Jindal/Rashmi.
All as per Item Ser Item No 41.00 here-in-before but of size 400 mm bore
All as per Item Ser Item No 41.00 here-in-before but of size 300 mm bore
M&L for caulking of lead joints with lead wool at places of leakage from the pipe and arresting leakages for 500mm bore of pipe, complete all as specified and as directed by Engr-in-Charge
M&L for caulking of lead joints with lead wool at places of leakage from the pipe and arresting leakages for 400mm bore of pipe, complete all as specified and as directed by Engr-in-Charge
M&L for detecting leakage in cast iron pressure pipes of 200/300/400 mm bore in any location, any depth including necessary earthwork excavation and repairing and arresting leakage by providing jointing material, flanged clamps, nuts, washers & bolts etc. complete all as specified and as directed.
S&F in replacement sluice valve, cast iron body, stainless steel spindle, gun metal rings including wheel for operation, flanged and drilled of following size of pipe, confirming to IS - 14846, class PN -1.6, long body type including all joints with rubber gasket and jointing materials, bolts, nuts, washer complete all as specified and as directed. (a) 400 mm bore.
(b) 300 mm bore
(c) 250 mm bore
(d) 200 mm bore
M&L taking out sluice valve of 100mm bore, repairing and refixing the same after re-facing, grinding the valve check nut, Spindle etc. including jointing materials complete all as specified and directed.
All as per Item Ser Item No 51.00 here-in-before but of size 200 mm bore
All as per Item Ser Item No 51.00 here-in-before but of size 250 mm bore
All as per Item Ser Item No 51.00 here-in-before but of size 300 mm bore
All as per Item Ser Item No 51.00 here-in-before but of size 400 mm bore
All as per Item Ser Item No 51.00 here-in-before but of size 500 mm bore
M&L for repairs to air release valve, of 150 mm bore of pipe and refixing the same after replacing the unserviceable HDPE float, nuts, bolts and jointing materials complete all as specified and directed.
All as per Item Ser Item No 57.00 here-in-before but of size 200 mm bore
M&L for run lead joint confirming to IS specifications for cast iron pressure pipes of 100/200 mm bore, socket and spigot or specials complete all as specified and as directed.
All as per Item Ser Item No 59.00 here-in-before but of size 300/400 mm bore
All as per Item Ser Item No 59.00 here-in-before but of size 500 mm bore
M&L for repairs to 400mm bore non- return valves by opening valve, cleaning the gates with wire brush, removing deposited scales/ foreign materials, rubbing the seat with emery paper and repalcing unserviceable gasket and worn out parts etc, and refixing back to original position, complete all as specified and as directed. Make : Kirloskar / Leader / Upadhayaya / BIR
All as per Item Ser Item No 62.00 here-in-before but of size 200 mm bore
M&L for replacement of butterfly valve heavy duty flanged ends drilled ISI marked confirming to IS: 14846 suitable for following bore pipe including nuts, bolts and jointing with jointing materials etc. complete including taking out old existing unsv butterfly valve including making arrangement for safe working all as specified and directed. Make: BIR, KIRLOSKAR or equivalent (a) 200 mm dia
(b) All as per Item Ser Item No 64.00 here-in-before but of size 150 mm dia
Supply only grass and weeds killer chemical of make Roundup (01 litre pack) all as specified and directed.
M&L for preparing old painted or untreated exposed surfaces of GI/ CI / DI Pipes of size 500/ 400/ 300 bore, Valve Chamber Covers, clarifloculators, pump motors, railing any type and applying one coat of black coloured weather proof synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
M&L for construction of valve chamber of size 1200mmx1200mm x1200mm internal size suitable for sluice valve with PCC 1:3:6 type (C2) (using 40mm graded aggregate) for foundation, one hollow block masonry wall in cement mortar (1:4), 40mm thick PCC (1:2:4) type B1 (using 20mm graded aggregate) coping, rendering in CM 1:4, 15mm thick including provision of mild steel sheet cover of 3mm thick on 40x40x6 mm angle iron frame work emmbedded in concrete with suitable hinges and locking arrangements including two coats of black synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary excavation earth work on any type of soil etc. including removal of surplus soil and rubbish not exceeding 50m distance, including demolition of old valve chambers complete all as specified and as directed by Engr-In-Charge.
All as per Item Ser Item No 68.00 here-in-before but valve chamber of size 900 x 900x 900mm
M&L for dewtering complete trenches manually for repairing joints by cocking and inserting spurn yarn and Run lead joint, making good/ leakless the existing joint including necessary excavation and earth work like returning, filling, making good to the existing earth level of the surroundings areas after repair for pipes of following sizes of pipes complete all as specified and directed :- (a) 80 mm dia
(b) All as per Item Ser Item No 70.00 here-in-before but valve chamber of size 100 mm dia.
(c) All as per Item Ser Item No 70.00 here-in-before but valve chamber of size 150 mm dia
(d) All as per Item Ser Item No 70.00 here-in-before but valve chamber of size 200 mm dia
(e) All as per Item Ser Item No 70.00 here-in-before but valve chamber of size 250 mm dia
(f) All as per Item Ser Item No 70.00 here-in-before but valve chamber of size 300 mm dia
Preparation of old surface shall include brooming down or steel wire brushing & scrapping down and white washing two coat on surface of UG Sump and installation all as specified and as specified and as directed
M & L in replacement of PCC 1:3:6 type CI (using 20mm graded aggregate) as in coping (including necessary form work) complete, all as specified and as directed by Engr-in-Charge.
Supply only PH test Kit including all testing materials
Supply only Ortho Tolidine solution in 500ml bottle pack.
Supply Only Pocket PH Meter (Dual display), Range-0.00 to 14.0 PH, Accuracy +/- 0.1 PH
Supply Only Portable TDS Meter, Range-0 to 19990 PPM, Accuracy +/- 2% F.S
M&L for servicing of JAR test apparatus (flocuculator) and made it serviceable by replacing any parts all as specified and as directed. Note : Rate deemed to be included replacement cost spare parts if necessary all as specified and as directed
Supplying, fixing and testing of Cast Iron, heavy duty, Specials of any size, radius and length confirming to IS - 1538 Part - I to XXIII: 1976 such as bends [any type, radius and angle], tapers any type [straight, bend, increasing, decreasing or double socket etc], sockets, tail pieces, connecting pieces, tee pieces, single branch, "Y" junction, double branch, cross, [all sockets or socket and spigot or Flanged], collars, caps and plugs, ( required for shape as per site )adopters etc suitable for CI / DI Spigot and Socket or Flanged pressure pipes complete all as specified and as directed.
S&F in repair electric shock treatment chart coloured fixed in 90cm x 60cm x 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete all as specified and directed.
S&F in repair machinary maintenance chart coloured of size approximately 120cm x 90cm x 6mm thick plywood with teak wood frame including covered with plastic laminated sheet fixing 06 Nos of Clips complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep and getting out for taking out or laying of pipes / cable of any size in Soft/ loose soil complete all as specified and as directed.
Returning filling in including spreading leveling watering and well ramming in layers n.exc. 25cm in any type of soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
S& F in replacement steel water tubes medium grade (ISI marked) galvanised with all fittings and fixed to walls or laid on floor or in ceilings of size 20 mm bore pipe including taking out of old pipelines complete all as specified and as directed by Engr-in-Charge. Make : Tata/Jindal/Bansal
All as per Item Ser Item No 89.00 here-in-before but of size 25 mm dia. Make: Tata/Jindal/Bansal
All as per Item Ser Item No 89.00 here-in-before but of 40 mm dia. Make: Tata/Jindal/Bansal
Supplying and laying of 20mm CPVC pipes SDR 13.5 & Plain CPVC SDR 13.5 grade with all types of fittings such as bends, tees, short pieces, connectors, elbows, reducers, union, sockets etc as required at site, fittings on walls/ceiling or laying in floors of following sizes, complete all as specified and directed .
All as per Item Ser Item No 92.00 here-in-before but of 25mm CPVC pipes
All as per Item Ser Item No 92.00 here-in-before but of 40 mm CPVC pipes
All as per Item Ser Item No 92.00 here-in-before but of 50 mm CPVC pipes
All as per Item Ser Item No 92.00 here-in-before but of 80 mm CPVC pipes
S&F in replacement for ball valves of 20MM dia UPVC complete all as specified and as directed.
All as per Item Ser Item No 97.00 here-in-before but of size 25mm bore
All as per Item Ser Item No 97.00 here-in-before but of size 40mm bore
All as per Item Ser Item No 97.00 here-in-before but of size 50mm bore
S&F in replacement for union socket of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 101.00 here-in-before but of size 25mm bore
All as per Item Ser Item No 101.00 here-in-before but of size 40mm bore
All as per Item Ser Item No 101.00 here-in-before but of size 50mm bore
S&F in replacement for coupler of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 105.00 here-in-before but of size 25mm bore
All as per Item Ser Item No 105.00 here-in-before but of size 40mm bore
All as per Item Ser Item No 105.00 here-in-before but of size 50mm bore
All as per Item Ser Item No 105.00 here-in-before but of size 80mm bore
All as per Item Ser Item No 105.00 here-in-before but of size 100mm bore
S&F in replacement for Tank connector Moulded of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 111.00 here-in-before but of size 25mm bore
All as per Item Ser Item No 111.00 here-in-before but of size 40mm bore
S&F in replacement for TEE of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 114.00 here-in-before but o size 25mm bore
All as per Item Ser Item No 114.00 here-in-before but o size 40mm bore
S&F in replacement for Reducer of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 117.00 here-in-before but of size 25x20mm bore
All as per Item Ser Item No 117.00 here-in-before but of size 40x25mm bore
All as per Item Ser Item No 117.00 here-in-before but of size 50x40mm bore
S&F in replacement for Reducing Elbow of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 121.00 here-in-before but of size 25x20mm bore
S&F in replacement for Elbow of 20mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 123.00 here-in-before but of size 25mm bore
All as per Item Ser Item No 123.00 here-in-before but of size 40mm bore
All as per Item Ser Item No 123.00 here-in-before but of size 50mm bore
All as per Item Ser Item No 123.00 here-in-before but of size 80mm bore
All as per Item Ser Item No 123.00 here-in-before but of size 100mm bore
S&F in replacement for Reducing bush of 20x15mm bore CPVC pipes of pressure rating 10Kgf/sqcm fixed of Schedule 80 graded complete all as specified and directed
All as per Item Ser Item No 129.00 here-in-before but of size 25x15mm bore
All as per Item Ser Item No 129.00 here-in-before but of size 25x20mm bore
M&L for CPVC and UPVC Adhisive solution Gel type 118ml Tin for jointing of pipes.
S & F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed complete after dismantling and taking out the existing unserviceable Gun metal gate valve of size 20 mm all as specified and as directed by Engr-in-Charge. Make : NMV, ZOLOTO, LEADER
All as per Item Ser Item No 133.00 here-in-before but of size 25 mm.
All as per Item Ser Item No 133.00 here-in-before but of size 40 mm.
All as per Item Ser Item No 133.00 here-in-before but of size 50 mm.
S & F in replacement 20mm dia Ball valves (Float Valve) high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed complete all as specified and as directed. (Minimum weight 20mm-210gms./ 25mm-455gms/ 40mm - 690 gms)
All as per Item Ser Item No 137.00 here-in-before but 25 mm dia
All as per Item Ser Item No 137.00 here-in-before but 40 mm dia
All as per Item Ser Item No 137.00 here-in-before but 50 mm dia
S&F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw ,complete all as specified and directed
S&F in replacement single pointed Air termination, copper rod 12mm dia and 300mm long fixed on overhead reservoirs for lighting protection with necessary connections to earthing etc complete all as specified and directed
S&F in replacement GI union socket of 25mm bore medium grade ISI marked.
S&F in replacement GI socket of 25mm bore medium grade ISI marked.
S&F in replacement GI Nipple of 4 Inch size 50mm bore medium grade ISI marked.
S&F in replacement GI elbow of 50mm bore medium grade ISI marked.
S&F in replacement GI elbow reducer of 25x20mm bore medium grade ISI marked.
S&F in replacement GI Plug of 25mm bore medium grade ISI marked.
S&F for PVC flexible green pipe 40 mm dia for swimming pool.
Supply only nylon rope of size 25 mm for suction sweeper motor.
Supply only M Seal of 100g Pocket for attending day to day complaint of external water supply complete all as specified and directed.
S&F Medium Grade GI Nipple (ISI marked) of following sizes complete all as specified and directed. (a) Nipple GI 20 x 150 mm
(b) Nipple GI 20 x 75/100 mm
(c) Nipple GI 25 x 150 mm
(d) Nipple GI 25 x 75/100 mm
M&L for Cutting of existing GI pipe in position for taking down addition alteration or for repair complete all as specified and directed for the following sizes :- (a) 40 to 50 mm bore
(b) All as per Item Ser Item No 156.00 here-in-before but of 20 to 25 mm bore
M&L for Cutting of existing GI pipe and Screwing (Threads making ) of existing galvanised steel tubing for addition alteration extending or reducing in length for repair all as specified and directed for following sizes:- (a) 40 to 50 mm bore
(b) All as per Item Ser Item No 158.00 here-in-before but of 20 to 25 mm bore
S&F Medium Grade GI Union (ISI marked) of following sizes complete all as specified and directed. (a) GI Union 20 mm
(b) All as per Item Ser Item No 160.00 here-in-before but of GI Union 25 mm
(c) All as per Item Ser Item No 160.00 here-in-before but of GI Union 40 mm
(d) All as per Item Ser Item No 160.00 here-in-before but of GI Union 50 mm
S&F Medium Grade GI Tee Reducer (ISI marked) of following sizes complete all as specified and directed. (a) Tee 40- 25 mm
(b) All as per Item Ser Item No 164.00 here-in-before but of Tee 25 -20 mm
S&F Medium Grade GI Socket Reducer (ISI marked) of following sizes complete all as specified and directed. (a) GI Socket Reducer 25 -20 mm
(c) All as per Item Ser Item No 166.00 here-in-before but of GI Socket Reducer 40 -25 mm
S&F Medium Grade GI Tee (ISI marked) of following sizes complete all as specified and directed. (a) Tee 20 mm
(b) Tee 25 mm
(c) All as per Item Ser Item No 168.00 here-in-before but of Tee 40 mm. NOTES :- 1. The contractor or his authorised representative shall report to concered JE or the Engineer-in-charge at 0900 hours daily on all working days to receive order/instructions of the work or complaints. A register shall be maintained to record all orders & instructions and their complaints and is to be signed by the contractor/his representative and the Engineer-in -Charge / JE Concered. 2. The service tanks are positioned on roof top of multi storied buildings upto four storey. Contractor is responsible to ensure that the labour employed should be equipped with safety items like industrial helmet, safety belt, extensible ladder of 40 feet length, plumbing and cuttings tools, etc 3. In case the contractor fails to attend/rectify the defects within the above time limit, penalty will the imposed as Rs 500/- per day in case of complaints/jobs.
SKV Engineering
M/s Kamal Electrical
RPG AND COMPANY
N Rathinam
V KARTHICK
Bismi Builders & Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .