Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC Accepted being L-1 | |
| 2 | L2₹23.1 L+₹8.1 L (54.3%)Rejected-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-AOC Not accepted being L-2 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
12 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MISC MAINT WORKS OF CENTRAL HEATING SYSTEM INCL RE
MISC MAINT WORKS OF CENTRAL HEATING SYSTEM INCL REPAIR/REPLACEMENT OF PIPELINES TRANSIT CAMP AND SEC HOSP AT ROCKFALL UNDER GE PARTAPUR
MISC MAINT WORKS OF CENTRAL HEATING SYSTEM INCL REPAIR/REPLACEMENT OF PIPELINES TRANSIT CAMP AND SEC HOSP AT ROCKFALL UNDER GE PARTAPUR
2022_MES_551869_1
GE/P-62/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE PARTAPUR
As per tender documents
8 documents required · 8 mandatory
₹500
MISC MAINT WORKS OF CENTRAL HEATING SYSTEM INCL RE
₹36,000
Yes
19 Oct 2022
14 Sept 2022
14 Oct 2022
14 Sept 2022
12 Oct 2022
28 Sept 2022
14 Sept 2022 - 19 Sept 2022
Amount
M&L dismantling carefully of Chimney smoke exhaust outlet fabricated extension MS pipe of boiler cleaning, removal carbon by scraping out and washing with scalent and acid/kerosene oil etc and removing of fume waste carbonized materials and disposal of fume waste every after 500 Hrs operation incl re-assembling all the dismantled component to its original position for smooth functioning of chimney, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator of 2.5 Lakh K.Cal/hour capacity of any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator of 2.0 Lakh K.Cal/hour capacity of any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling oil fired hot water generator of 1.5 Lakh K.Cal/hour capacity of any model by unscrewing and removal of boiler side/end plates, CHS control panel, cleaning drum and hot water coil with scalent de-carbonizing, scraping out carbon ,dirt acculated in drum and across coil, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning, Complete all as specified and directed by Engineer-in-Charge.
M&L for dismantling Standalone air heater for space heating of capacity upto 25000 Kcal/hr by unscrewing and removal of heater side/end plates, with scalent de-carbonizing, scraping out carbon, dirt acculated in heater, overhauling, servicing incl re- assembling all the dismantled component to its original position with testing and commissioning all as specified and directed by Engineer-in-Charge.
M&L for dismantling of the blower motor of Stand alone air heater for space heating of capacity upto 25000 K/Cal Hr incl rewinding of blower motor with suitable size/gauge of copper wire including replacement of suitable blower fan sweep and blower fan guard and refixing of the same after varnishing all as specified and directed by Engineer-in-Charge.
M&L for dismantling carefully CHS pump and motor assembly upto 7.5 HP for repair and remove the broken impeller and worn out nuts/bolts washer's complete incl rewinding removal of burnt winding for field and stator, rewinding the same with super enamel copper conductor of existing gauge varnishing, heating, baking complete with re-assembling all the dismantled component to its original position with testing complete all as specified and directed by Engineer-in-Charge.
M&L for disconnecting and removal of burner assembly, cleaning of Ecoflame burner for de-carbonized/deposited on combustion tank/blast tube with cleaning acid and fixing of burner nozzle for smooth functioning and re-assembling burner and fixed to its original position with testing complete all as specified and directed by Engineer-in-Charge.
M&L for taking down carefully by disconnecting and removing Fan coil units of different capacities from hot water circulation line for cleaning with scalent and acid to remove the scale and dirt accumulated in copper tube and fins and welding /brazing where ever necessary and arrest the leakage of the body incl re-assembling and connect the same to its original position with testing complete for smooth flow of water, complete all as specified and directed by Engineer-in-Charge.
M&L for taking down carefully by disconnecting and removing heat radiator from hot water circulation line for cleaning with scalent and acid to remove the scale and dirt accumulated in copper tube and fins and welding /brazing where ever necessary incl re-assembling and connect the same to its original position with testing complete for smooth flow of water, Complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of burner nozzle and calibration at require temperature and pressure for proper fuel automisation incl setting for correct mixing ratio of fuel and air for proper combustion of fuel with base mounting unit, Complete all as specified and directed by Engineer-in-Charge. Make : Ecoflame or Equivalent
M&L for disconnecting hot water inlet & outlet of glycol base storage tank of capacity upto 1000 Ltrs draining out complete old water cleaning, removal of sludge acculated by scraping out, washing with scalent/acid for properly cleaning and welding wherever necessary to arrest leakages with re-assembling the disconnected pipes to original position and filling water including refilling/ charging of glycol (monoethylene glycol) MEG concentrate along with necessary additives and inhibitor in cognition and mixed in ratio 40% (glycol concentrate) 60 % of water and the freezing temperature of mixture shall be -40 degree centigrade, Complete all as specified and directed by Engineer-in-Charge. (Note : Monoethylene glycol will be measeured and paid seperately)
M&L for dismantling old unserviceable standalone oil fired heater and Supply installation testing and commissioning standalone oil fired Kerosene/HSD based Air heating system complete with stainless steel heat exchanger chamber single phase double blower motor to deliver 25000 Kacl/Hr heat at the rate of 4500 CFM with thermostat control, indication LED lamp three pin 15 Amp Plug with fuel storage for 25 Ltrs capacity duly installed in repair as per site directed by Engr-in-Charge. Make-Thermax Alfa Therm Maxo Boiler
Dismantling old unserviceable fan coil unit and Supply and fixing new fan coil unit of capacity 3000 Kcal/Hr or One Ton capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control Make-GET/ Bluestar/voltas
Dismantling old unserviceable fan coil unit and Supply and fixing new fan coil unit of capacity 4500 Kcal/Hr or One Ton capacity High Wall mounted motorised valve alongwith Inlet outlet valves and remote control Make-GET/ Bluestar/voltas
S & F in replacement of unserviceable magnetic lead (Electrode) as per sample with testing complete and suitable for control the temperature and fuel firing in combustion chamber, complete all as specified and directed by Engineer-in-Charge.
Supply and fixing bronze Impellor as per sample sample and existing, Complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement time relay suitable for CHS burner assembly, Complete all as specified and directed by Engineer-in-Charge.
Supply and fix ball brass valve with adapter screwed both ends of 15 MM bore suitable for heat radiator hot water inlet/outlet, Complete all as specified and directed by Engineer-in-Charge. Make : CE /Zoloto/Leader/ R&N
Supply and fixing bearing No 2052 incl oiling and lubrication , Complete all as specified and directed by Engineer-in-Charge. Make - SKF or equivalent.
S&F metal coupling of the CHS pump 2 HP male/female star couppling as per sample, Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing coupler with fiber super impregnated suitable to match the male/female couplings as per sample Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC flexible pipe insulated model SAE 100 RIAT 1/2" suitable for fixing with heat radiator hot water inlet and out let with locking clips, Complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S chimney exhaust extension pipe of size 200 mm dia 3 length 6 mm thick, Complete all as specified and directed by Engineer-in-Charge.
Supply, mixing and filling of mono ethylene Glycol concentrate along with necessary additives and inhibitor in congnition and sealed in barrels. The mixture freezing tempreture shall be (-) 35°C, all as specified. The mode of payment and operation involved for this item shall be as under:- Note: (a) Mono Ethylene Glycol in concentrated from shall only be measured and paid under this item. (b) Material and labour for mixing, filling, preparation fo Gylocol Charge to get total quantity of mixture including first filling required for operation of CHS plant and network having 40% quantity of treated water available at site and 60% of mono ethylene glycol supplied as above to attain the freezing temperature of mixture as (-) 35°C. The quoted rates shall be deemed to include the above activity/work. (c) The water for preparation of mixture will be supplied by MES without any extra charges for this item (only). The water shall be supplied at a point decided by GE and quoted rates shall deemed to be included for transportation of same from the take off point. (d) Any other additives and inhibitors as per the requirement laid down in relevat IS shall also deemed to included in quoted rates. (e) Empty barrels shall be the property of contractor. Make: Indian oil/Hindustan petrolium/Bharat petrolium/caltax
M&L for Calibration of humidity control system to maintain required humidity for smooth functioning & maintaining the humidifier to required humidity , Complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S phase sequence meter 230 volt 50 Hz AC as per sample for each phase , Complete all as specified and directed by Engineer-in-Charge. Make : L&T/C&S/Havells'/Legrand
Supply and fixing Ignition transformer suitable for burner (ECOFLAME), Complete all as specified and directed by Engineer-in-Charge. Make ECOFLAME/Equivalent
M&L for dismantling of the hot water circulating pump motor of 5 HP incl rewinding with suitable size/gauge of copper wire including replacement of suitable bearing warn out nuts/bolt washer and refixing of same after varnishing, Complete all as specified and directed by Engineer-in-Charge.
S&F copper tubing of size 15 mm with copper union and adopter including all fitting for inlet and outlet complete.
Supplying and laying,connecting,fixing in repair/replacement including taking out the existing pipe and testing of MS ERW'C' class piping complete with fittings,duly insulated with 18mm/13 mm thick closed cell elastomeric insulation 30 to 40 KG/m3 density for the following sizes of Hot Glycol fluid pipes. (The pipes shall be provided with 24 SWG aluminium cladding over the insulation for exposed piping only and underground pipe shall be laid down till 1.5m in depth)
80mm bore pipe with 25mm thick nitrile insulation
65mm bore pipe with 13mm thick nitrile insulation
50mm bore pipe with 13mm thick nitrile insulation
40mm bore pipe with 13mm thick nitrile insulation
32mm bore pipe with 13mm thick nitrile insulation
25mm bore pipe with 13mm thick nitrile insulation
20 mm bore pipe with 13mm thick nitrile insulation
Excavatoin in trenches not exceedng 1.5 mtr wide but exceeding 1.5 mtr in depth for laying of pipe and getting out all in hard and dence soil.
Returning filling in including spreading watering and well ramming in layer not exceeding 25mm thick in hard dence soil
Removing excavated material (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point.
M&L for cement concrete in foundation, filling and mass concrete type B1 1:2:4 using 20mm graded stone aggregate for foundation.
Deduct Schedule of Credit of Rs (-) 25580.00 (Minus) as listed in Schedule 'A' Part-II. Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
EESSI
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .