Loading…
Loading…
Tender Value
₹2.6 Cr
EMD Value
₹15 L
Closing Date
30 Sept 2026, 12:00 pm3d left
Superintending Engineer Deoria Circle PWD Deoria
Office of The Superintending Engineer Deoria Circle PWD Deoria
Construction of 08 No. Residential Building Type-3 for Employees at the Lahori Shed in Dist Deoria
2026_CEGKP_1186143_1
4252/76yat-Deo Circle/26 Dated 07.09.2026
Open Tender
Civil Works - Buildings
Percentage
270 days
Deoria
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,714
₹15 L
Deoria
23 Sept 2026
23 Sept 2026
30 Sept 2026
23 Sept 2026
30 Sept 2026
23 Sept 2026
26 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. AS Per DSR-2.6.1 (Excluding GST) | 711 | CUM | 120 | ₹85,320 |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. AS Per DSR-2.25 (Excluding GST) | 497 | CUM | 133 | ₹66,101 |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. AS Per DSR-2.25,a (Excluding GST) | 223 | CUM | 476 | ₹1,06,148 |
| 4 | Sand filling in plinth under floors including watering, ramming, consolidating and dressing complete including lead up to 50m and lift upto 1.5m and including cost of sand. AS Per DSR-2.27 (Excluding GST) | 74 | CUM | 1,443 | ₹1,06,782 |
| 5 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floorWith Chlorpyriphos/Lindane E.C. 20% with 1% concentration AS Per DSR-2.35.3 (Excluding GST) | 1,374 | SQM | 210 | ₹2,88,540 |
| 6 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg /cum AS Per DSR-4.20.1.1 (Excluding GST) | 131 | CUM | 6,006 | ₹7,86,786 |
| 7 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level AS Per DSR-5.33.1.1 (Excluding GST) | 158 | CUM | 6,462 | ₹10,20,996 |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level AS Per DSR-5.33.2.1 (Excluding GST) | 313 | CUM | 6,703 | ₹20,98,039 |
| 9 | Add for using extra cement in the items of design mix over and above the specified cement content therein. AS Per DSR-5.35 (Excluding GST) | 155 | QTL. | 498 | ₹77,190 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5000 or more. AS Per DSR-5.22.6 (Excluding GST) | 488 | QTL. | 7,332 | ₹35,78,016 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.05 MB
Tendernotice_2.pdf
PDF • 3.16 MB
Tendernotice_3.pdf
PDF • 0.18 MB
BOQ_2232400.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .