Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | ₹21.4 L | L1 | Accepted-AOC Being lowest |
| 2 | L2₹23.0 L+₹1.5 L (7.14%)Rejected-Finance | ₹23.0 L+₹1.5 L (7.14%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹24.5 L+₹3.0 L (14.1%)Rejected-Finance | ₹24.5 L+₹3.0 L (14.1%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹25.3 L+₹3.8 L (17.9%)Rejected-Finance | ₹25.3 L+₹3.8 L (17.9%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹25.5 L+₹4.0 L (18.8%)Rejected-Finance | ₹25.5 L+₹4.0 L (18.8%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹25.4 L
EMD Value
₹50,900
Closing Date
4 Sept 2021, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim 737102
Repair maint of street light at New Cantt Burdong and Sirwani area under GE Gangtok
2021_MES_454748_2
8970
Open Tender
Miscellaneous Works
Item Rate
182 days
Gangtok
As per tender documents
8 documents required · 8 mandatory
₹500
GE Gangtok
₹50,900
Yes
13 Sept 2021
28 Aug 2021
7 Sept 2021
28 Aug 2021
4 Sept 2021
28 Aug 2021
Amount
Taking out old unserviceable, burnt, punctured aluminium conductor cable LT, PVC/XLPE, 1100 volts grade, of cross sectional area upto 16 Sqmm all as specified and directed.
Supply and laying Galvanized Iron pipe light grade of dia 50mm for cable protection in trenches/ducts/floors or fixed on walls / roof / poles etc including suitable fixing accessories complete all as specified and directed. Make : Tata/Jindal/Prakash. Note :- Wherever the protection pipes are to be laid/fixed on poles/walls/other surface the cost of clamping using appropriate size/type of MS clamps,nuts, bolts etc is deemed to be included in the unit quoted rates.
Supplying, laying, commissioning & testing of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 4 core 16 Sqmm, including cable lugs, connection/termination complete all as specified and directed.
Supplying, laying, commissioning & testing of LT underground cable, XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 2 core 10 Sqmm, including cable lugs, connection/termination complete all as specified and directed. Note for item No 3 & 4 :- Wherever the cables are to be laid/fixed on poles/walls/other surfaces the cost of clamping using appropriate size/type of Saddles,MS Clamps,nuts both etc is deemed to be included in the unit quoted rates.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m depth for taking out, laying of cables etc and getting out in hard/dense soil incl connected items complete all as specified and directed. Note : Any damages made/caused to the HT/LT cables, Water Supply pipe lines , OFC Cables etc during the excavation works shall be made good by the Contr as per Original & to the entire satisfaction of Engr-in Charge & GE. Cost of the same is deemed to be included in the unit quoted rates.
Returning filling in soft/loose soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed
Removal of surplus excavated (soil) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.50m above the starting point complete all as specified and as directed.
Supplying and laying of DWC HDPE pipe .lSI marked in trenches or in cable ducts or fixed on walls using clamps along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. of size 50 mm outer dia complete all as specified and as directed by the Engr-in-Charge.
M & L for providing PCC (1:3:6) type B-1, (using (20mm graded stone aggregate) for coping of poles including necessary form work etc complete all as specified and directed.
M & L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) upto 20 cm depth, finishing to a uniform smooth surface to match the existing surface complete all as specified and directed. Note : (i) GI pipes shall be measured and paid separately. (ii) Any damages made/caused to the HT/LT cables, Water Supply pipelines , OFC Cables etc during the excavation works shall be made good by the Contr as per Original & to the entire satisfaction of Engr-in Charge & GE. Cost of the same is deemed to be included in the unit quoted rates.
S & F loop in- loop junction box of internal dimension 155 x 210 x 92 mm made out of polycarbonate and locking arrangement incl 6 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/out going, mounted in the box, fixing on steel tubular poles including necessary clamps, suitable glands, lugs and GI nut and bolts including taking down old unserviceable junction box complete all as specified and directed. Make : Hensel, Cat No : KF 1616 G or equivalent make as approved.
Taking down old unserviceable street light fitting any type such as Street light/ floodlight/LED fittings any wattage from pole/ bldgs and carried out necessary repairs and refixing the same / serviceable condition all as directed by engineer in charge
Supply, fix and test, in replacement of LED Street light fitting of capacity 90 Watts, CRI >70, power factor > 0.95, colour temperature 5700K, luminous efficacy not less than 100 lumen/watt, 9000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories, lamp bracket with impact and corrosion resistant and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLPLUS SL90WLED757SASYTOPCASTHO or equivalent make as approved.
Supply, fix and test, in replacement of LED Street light fitting of capacity 60 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous Efficacy not less than 100 lumen/watt, 6000 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection,phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories, lamp bracket with impact and corrosion resistant and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLNEO SL60WLED757PASYTOPC or equivalent make as approved.
Supply, fix and test, in replacement of LED Street light fitting of capacity 45 Watts, CRI >70, Power factor > 0.95, colour temperature 5700K, luminous Efficacy not less than 100 lumen/watt, 4500 Lumens output, IP-66 protection including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270 V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated grey colour after phospho chromate treatment with all accessories, lamp bracket with impact and corrosion resistant and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No: ENDURAPEARLNEOSL45WLED757SASYTOPC or equivalent make as approved.
Supply, fix and test LED Flood light fittings for Midmast, of capacity 120 Watts, CRI>70, Power factor >0.95 colour temperature 5700K, luminous Efficacy not less than 100 lumens/watt, colour temperature 5700K, 12000 lumens output, IP-66 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc) unit suitable for working voltage 140-270V AC, 50 Hz pressure die cast aluminium housing and finishing epoxy powder coated with all accessories as per manufacturer's instructions and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havells, Cat No:JETA JETAIRISFLS 120WLED757APWBLTG or equivalent make as approved.
Supply, fix and test, in replacement of LED Flood light luminaire with high power of capacity 50 Watts suitable for working Voltage of 140-270 V AC, 50 HZ with in built power unit, electronic driver etc, pressure die-cast aluminum housing connecting up with all accessories including taking down unserviceable fitting complete all as specified and directed. Make: Havells, Cat No. JETAQUANTOPLUS FLP50WLED757SYMLENS or equivalent in Philips/Jaquar
Supply, fix and test, in replacement of LED Flood light luminaire with high power of capacity 30 Watts suitable for working Voltage of 140-270 V AC, 50 HZ with in built power unit, electronic driver etc, pressure die-cast aluminum housing with all accessories, connecting up including taking down unserviceable fitting complete all as specified and directed. Make: Havells, Cat No : JETAQUANTOPLUS FLP30WLED757SYMLENS or equivalent make as approved.
S & F in replacement of building security light fittings 25W LED 6000K with IP 66 protection & fixing to the wall, using suitable GI bracket with the use of nut and bolts, making connections from ceiling rose including taking down old unserviceable one complete all as specified and as directed. Make : Havells, Cat No: ENDURAPEARLSL 25WLED757SASYTOPC or equivalent make as approved.
S & F in replacement of Garden light LED bollard 8W, 3000K with aluminium landscape luminaire with IP65 protection with fixing accessories including taking down the unserviceable fitting complete all as specified and directed. Make : Havells,Cat No: MINIMOUNTBL10 WLED830PSYMTOPMMAM or equivalent in Philips/BajajNote for item No 14 to 21 :- (i) Test certificates in support of the technical parameters of the light fittings is to be submitted in original to the Engr-in-Charge by the contractor. (ii) Design/Drawing/BOM/Technical specification of the LED fittings /fixture is to be submitted to the Engr-in-Charge /GE for approval wherever techno-commercially equivalency of the product/item is concern w.r.t given make/Cat Part is concerned. (iii) Decision of the Engr-in-Charge/GE shall be final & binding. (iv) Any items\ missing but technically required for effcient performance of the fittings/fixture is deemed to be included in the unit quoted rates. (v) Cost of suitable fixing arrangements like MS clamps, nuts bolts, washer etc to the entire satisfaction of Engr-in-Charge is deemed to be included in the unit quoted rates.
M&L for repair of street light/flood light LED fitting of capacity 25W /30W /45W /50W /60W /72W /90W /120W/150W , disconnecting and bringing down from pole, fixing after repairs including replacement of unserviceable spare parts all as specified and directed. Note:- The unserviceable spare parts replaced shall be measured and paid seperately. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
Supply only, driver suitable for 100W LED floodlight complete all as specified and directed. Havells or equivalent make as approved.
Supply only, driver suitable for 50W LED floodlight complete all as specified and directed. Make: Havells or equivalent make as approved.
Supply only, driver suitable for 30W LED floodlight complete all as specified and directed. Make: Havells or equivalent make as approved.
Supply only, driver suitable for 90W LED streetlight complete all as specified and directed. Make: Havellsor equivalent make as approved.
Supply only, driver suitable for 60W LED street light complete all as specified and directed. Make: Havells or equivalent make as approved.
Supply only, driver suitable for 45W LED street light complete all as specified and directed. Make: Havells or equivalent make as approved.
Supply only, driver suitable for Bamboo garden light fitting 8W LED (driver only) complete all as specified and directed. Make: Havells or equivalent make as approved.
Supply and fix in replacement of bracket suitable for street light, made out of 40 mm dia 1.5 mtr length GI pipe light grade bent to shape fixed with suitable size of clamps (2 Nos), bolts, nuts and washers incl painting with one primer coat and two coats of aluminium paint complete including taking down old unserviceable one and all as specified and directed.
S & F in repairs rigid non-metallic PVC conduits of external dia 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends with aluminium clamp, bolt, nuts etc for fixing including taking down old unserviceable conduits complete all as specified and directed.
S & F in replacement PVC insulated flexible multicore round copper conductor cable of size 3 core 1.5 Sqmm including necessary end connector incl taking down unserviceable cable complete all as specified and directed. Make:Havells or equivalent make as approved.
Supply and fix in replacement of Street light control panel, factory fabricated (CPRI type-tested) with MCB TPN 63 A - 1 No, Contactor TP 65 A- 1No, Astronomical Timer Street Light Control Panel with accessories outdoor type including connected switch gears, cables, etc and suitable sheet metal enclosure test and commisioning of Panel of 440V, out door cubical type with suitable provision of 25 x 25 x 3 mm angular base and vertical frame along with necessary PCC foundation and locking arrangement complete including taking out old unserviceable panel all as specified and directed. Make: Havells, Cat No : IHXTS0912A or techno-commercially equivalent make as approved. Note:- The quoted rate shall be inclusive of the following:- (i) Suitable copper control wiring inside Panel board, cable glands, cable lugs, supporting, insulators etc., (ii) Quoted rate is inclusive of angular base frame and PCC foundation, Earth work and connected accessories. (iii) The Panel should be mounted min 0.30m above the ground level, (iv) Design / drawing / BOM of the panel showing the dimensions is to be obtained from Manufacturer / Supplier & is to be got approved from the GE before placing final order to the manufacturer. (v) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
S & F Astronomical Timer switch unit operated on AC 110 - 240 V 24 hrs clock, day/week programmable time for controling street lights including taking down old unserviceable timer swiches complete all as specified and as directed. Make : L&T, Cat No : AUTS02DIG00 or equivalent make as approved.
S & F MNX 40 Power contactor of 40 Amps, AC 415 volts, TP for controling street lights including making connections and taking down old unserviceable contactor complete all as specified and directed. Make :L&T, Cat No : CS94190 or equivalent make as approved.
M & L for preparation of old painted surfaces of decorative stands/supports/fittings of garden light, scrapping with wire brush and applying one coat approved make/grade/color synthectic enamel paint after preparation of surfaces complete all as specified and as directed.
M & L for preparation of old painted surfaces of street light steel tubular poles above GL/coping including cross arms channels, flat iron clamps by scrapping with wire brush and applying one coats of aluminium paint including pole numbering using three layer of radium strip of min 4-5 inch wide (Yellow, Green, Blue) on each pole using Printastic letter all as specified and directed. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
M&L for trimming/clearing of tree branches leaves etc all around street/security light fittings etc in such a way that there must be a clearance of atleast 1.5 Mtr radius from the street/security light fitting etc.So as to facilitate proper illumination complete all as specified & as directed. Note : (i) Ladders scaffolding, safety belts etc required for excavation of the works shall be arranged by the contractor & the cost of the same is deemed to be included in the unit quoted rates. (ii) Contractor shall be fully responsible for the safety aspects of the people engaged by him & any issues (if any) arising during the work shall be dealt by the Contractor & the Dept shall be no way responsible whatsoever.
S&F MCCB 63 Amps, 4 Pole, 16 KA, Ics = 100% (Icu), 415 Volts 50 Hz, AC, suitable for existing LT panel/feeder pillar including taking out old existing unserviceable MCCB from panels etc complete all as specified and as directed. (Make: Cat Part No: Havells cat No IHLANF0063 or equivalent approved make.)
Supply and fixing LED Solar street light fitting 24 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately) with all accessories as per manufacturer's instructions and connecting up complete including taking down old unserviceable one all as specified and directed. Make: Havellsor equivalent make as approved.
M&L for Earthing complete in repairs with Advance encapsulated compound based CPRI tested maintenance free, pipe-in-pipe technology upgraded (Zinc & Alloy Coated), ZINC COATED (80-100) microns with pure Zinc(99.9%) & ALLOY COATING (200-250)microns. Earthing System confirming IS 3043.The outer and inner pipe should be 48.3mm &26.4mm 2mtrs Length, Zinc coated with additional special Alloy coating 300mm on the topside for additional protection of the Terminal. The annular space between the pipes being filled up with COMPACT FILL(CF) (Crystalline Conductive Compound). The COMPACT FILL (CF) mixture which is machine pressed inthe pipes should not disintegrate or collapse when outer pipe corrodes. The inner pipe should be extended with terminals for connectivity ,The job includes digging the pits and refilling the same by BARONS Electrodite OR Conductolite Back Fill compound (Ground Enhancer), the BFC should be eco friendly it should not contain environmentally hazardous material/metal having ROHS Certification from NABL accredited lab. The earth pit should be provided with a FRP OR EPCC earth pit cover for protection and safe guard of terminals. In areas where soil condition is bad, GOOD EARTH ie BLACK COTTON OR MOISTUROUS NORMAL SOIL is to be arranged to fill the excavated pits by mixing the arranged soil with BFC 2 TO 4 bags ELECTRODITE 0R 2-4 BAGS CONDUCTILITE BFC FOR INSTALLATION OF EARTH ELECTRODE. The electrode should be of galvinised (80-100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm, 7.5 m. including excavation earthwork etc connected to electrical eqpts/panels and testing on completion all as specified and directed by Engineer in charge.
shanti enterprises
M/S ANIL KUMAR THAKUR
KAMLESH ENTERPRISE
KARMA SHERPA
DHARMINDER SINGH
NISHA CONSTRUCTIONS
GEETA CONSTRUCTION
M/S MANOJ VERMA
Janata Enterprises
BIJAY MITTAL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .