Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.5 LAdmitted-Finance | ₹54.5 L | L1 | Admitted-Finance |
| 2 | L2₹74.7 L+₹20.1 L (36.9%)Admitted-Finance | ₹74.7 L+₹20.1 L (36.9%) | L2 | Admitted-Finance |
| 3 | L3₹1.2 Cr+₹63.1 L (115.7%)Admitted-Finance | ₹1.2 Cr+₹63.1 L (115.7%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Disqualified |
| Sl No | Description | Qty | Unit | aswani infrastructure L1 | ask enterprises L2 | PARNAVI ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00CIVIL INTERIOR WORKS | ||||||
| 2.00 | BRICKWORK/Masonry BREAKING: Demolishing existing damaged/cracked brickmasonry with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry/RCC structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of working premises complete all as directed by the Engineer-in-Charge. | 5 | Sqm | 500 ₹2,500 Lowest | 2,900 ₹14,500 | 1,250 ₹6,250 |
| 3.00 | LABOUR CHARGES FOR ALUM WORKSRemoving the existing partitions/ doors and handing over the same at required place indicated by the engineer in charge. etc. complete. | 50 | Sqm | 100 ₹5,000 Lowest | 250 ₹12,500 | 650 ₹32,500 |
| 4.00 | FLOORING BREAKING: Dismantling carefully the existing damaged cracked serviceable tiles/slabs/clay tiles/Marble slab/granite slab/Kota stone/tandoor stone/Shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material out of hospital premises as directed by the Engineer-in-Charge. | 500 | Sqm | 100 ₹50,000 Lowest | 400 ₹2,00,000 | 300 ₹1,50,000 |
| 5.00 | Removing existing false ceiling of any material and any size with all necessaryallied works, removing out debris out of ACTREC premises as directed by Engg-incharge. | 260 | Sqm | 100 ₹26,000 Lowest | 200 ₹52,000 | 250 ₹65,000 |
| 6.00 | Removing exisitng Metal Lab furniture & refixing the same after painting work done. | 850 | Sqm | 250 ₹2,12,500 | 220 ₹1,87,000 Lowest | 800 ₹6,80,000 |
| 7.00 | ALUMINUM PARTITION WORK WITH DOOR Providing & fixing alumimium partition to the required height partly glazed and partly panneled or fully glazed o r fully panneled using aluminium section of jindal 2425 satin finish anodizing of required size for bottom, top, middle & vertical rails at required intervals panneling with 12mm thick Nosva pan or ancholam both side pre-laminatd board fixed with sloping aluminium beeding alround with neoprine gasket glazing with 5.5mm forsted/ bajri/ plain glass of approved make like fixed with alumimium channel beeding two way PVC lining/ rubber gasket to ensure water tightness and Nos rattaling including providinG necessary cover mould using suitable alumimium section so as to take care of gaps between the walls/ ceiling / flooring and partitions etc. including providing and fixing necessary fittings as specified and directed. (Half paneleld/ fully glazed) | 36 | Sqm | 4,000 ₹1,44,000 | 3,800 ₹1,36,800 Lowest | 4,843 ₹1,74,348 |
| 8.00 | Providing & fixing 12mm thick nova pan both side laminated of approved colur and size as per site condition working at all heights and levels complete as directed and instructed. | 36 | Sqm | 1,000 ₹36,000 Lowest | 4,500 ₹1,62,000 | 4,951 ₹1,78,236 |
| 9.00 | TEAKWOOD In frames of doors, windows, ventilators and clearstorey windows etc. fixed with M.S hold fast of size 40x3mmx150mm long bend to shape & embeded in cement concrete 1:2:4. | 0.14 | Cum | 1,00,000 ₹14,000 | 1,45,950 ₹20,433 | 25,000 ₹3,500 Lowest |
| 10.00 | FLUSH SHUTTERProviding & fixing in position/flush door of 35mm thick shutters block board solid core internally lipped bonded with water proof type synthetic resin hot pressed with marine ply finished on both faces including prov. And fixing teak wood 20mm thick lipping on all sides fixing heavy duty approved make 4 levers mortice lock with pair of handle of approvd make & quality brass/S.S . fittings such as hinges, tower bolts, of approved make fixing fixtures locking arrangements with fixing fixture locking arrangements with screws etc. applying one coat of approved wood primer etc. all complete as specified and directed by Engineer-In-Charge. | 15 | Sqm | 3,000 ₹45,000 Lowest | 12,650 ₹1,89,750 | 11,000 ₹1,65,000 |
Tender Value
₹62.4 L
EMD Value
₹1.2 L
Closing Date
2 Aug 2025, 3:00 pmClosed
Director,TMC
Office of Engineering Services, Second Floor, Khanolkar Shodhika, ACTREC Kharghar Node, Navi Mumbai - 410210
Proposed Molecular Lab at KS-31,GF,CRI,ACTREC
2025_TMC_867415_1
ET-39/Molecular Lab/2025
Open Tender
Civil Works
Item Rate
90 days
ACTREC, Kharghar
As per Tender Document
2 documents required · 2 mandatory
₹0
₹1.2 L
ACTREC,Kharghar
16 Sept 2025
4 Jul 2025
4 Aug 2025
4 Jul 2025
2 Aug 2025
4 Jul 2025
4 Jul 2025 - 11 Jul 2025
14 Jul 2025
Amount
CIVIL INTERIOR WORKS
BRICKWORK/Masonry BREAKING: Demolishing existing damaged/cracked brickmasonry with cement mortar and plaster at all floors and levels including scaffolding stacking of serviceable materials without damaging the adjacent masonry/RCC structure sanitary fittings & fixtures and disposal of unserviceable material carting away the debris out of working premises complete all as directed by the Engineer-in-Charge.
LABOUR CHARGES FOR ALUM WORKSRemoving the existing partitions/ doors and handing over the same at required place indicated by the engineer in charge. etc. complete.
FLOORING BREAKING: Dismantling carefully the existing damaged cracked serviceable tiles/slabs/clay tiles/Marble slab/granite slab/Kota stone/tandoor stone/Shahabad stone and all types of flooring in flooring etc. including removing the 20mm thick bedding of cement mortar stone grit or brick bat coba etc. at all floors & levels including stacking of serviceable material out of hospital premises as directed by the Engineer-in-Charge.
Removing existing false ceiling of any material and any size with all necessaryallied works, removing out debris out of ACTREC premises as directed by Engg-incharge.
Removing exisitng Metal Lab furniture & refixing the same after painting work done.
ALUMINUM PARTITION WORK WITH DOOR Providing & fixing alumimium partition to the required height partly glazed and partly panneled or fully glazed o r fully panneled using aluminium section of jindal 2425 satin finish anodizing of required size for bottom, top, middle & vertical rails at required intervals panneling with 12mm thick Nosva pan or ancholam both side pre-laminatd board fixed with sloping aluminium beeding alround with neoprine gasket glazing with 5.5mm forsted/ bajri/ plain glass of approved make like fixed with alumimium channel beeding two way PVC lining/ rubber gasket to ensure water tightness and Nos rattaling including providinG necessary cover mould using suitable alumimium section so as to take care of gaps between the walls/ ceiling / flooring and partitions etc. including providing and fixing necessary fittings as specified and directed. (Half paneleld/ fully glazed)
Providing & fixing 12mm thick nova pan both side laminated of approved colur and size as per site condition working at all heights and levels complete as directed and instructed.
TEAKWOOD In frames of doors, windows, ventilators and clearstorey windows etc. fixed with M.S hold fast of size 40x3mmx150mm long bend to shape & embeded in cement concrete 1:2:4.
FLUSH SHUTTERProviding & fixing in position/flush door of 35mm thick shutters block board solid core internally lipped bonded with water proof type synthetic resin hot pressed with marine ply finished on both faces including prov. And fixing teak wood 20mm thick lipping on all sides fixing heavy duty approved make 4 levers mortice lock with pair of handle of approvd make & quality brass/S.S . fittings such as hinges, tower bolts, of approved make fixing fixtures locking arrangements with fixing fixture locking arrangements with screws etc. applying one coat of approved wood primer etc. all complete as specified and directed by Engineer-In-Charge.
LAMINATE Removal of old formica along with the adhesive making the surface smooth & providing & fixing new approved of required specification & colour etc. complete as specified & directed including fevicol, nails etc. complete.
KOTA STONE FLOORING: Kota stone flooring / dado / skirting at all floors and levels using 25mm to 30mm thick hand cut/machine cut single mirror polished kota stone slabs laid over 20mm thick cement mortar bedding as specified below close jointed and pointed with matching slurry of cement finished to levels or slope or plumb in quantities as required at site for new work and or repairs to old flooring / dados / skirting including curing etc. complete all as directed by the E-I-C.
FLOOR POLISHING:Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete.
VETRIFIED DADO/ FLOOR TILES Providing & laying polished vitrified floor tiles in different sizes (thickness to be specified by manufacturer) with water resistant less than 0.08% and confirming to IS 15622 of approved make in all colours & shades, laid on 20mm thick cement mortar 1:3 ( 1 cement : 3 coarse sand) including grouting the joints with white cement and matching pigments etc. complete
Providing & fixing of Metal metal tiled false ceiling for existing false ceiling by replacing existing perforated Gypsum sheets. Refixing existing damaged grid of size 2'x2' with proper alignment including fixing of new grid supports at necessary locations. All the grid supports are to be properly suspended from ceiling. Also removing of existing false ceiling & stacking down all serviceable material is in scope of contractor as directed by EIC.
GRANITE: Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
Wall Primer With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
Modular Lab Furniture MS Frame powder coated with SS Sink of min 500 x 400 x 150 mm deep with out drain board, the granite shall be placed on 12mm thick marine plywood, with CP swan neck 3 way tap used in labs, firmly fixed on grante and CP cover plate over granite. The pic enclosed is for reprentative purpose only. The agency shall submit the sample for approval before supplying in bulk, complete as directed and instructed.
Design, fabrication, supply & instalaltion of factory finished Lab working table with granite top of 600 mm wide with edge shamphered placed on 12mm thick marine ply fised firmly over dual colour powder coated metal frame, with shelves to keep reagensts and with dedicated power point have electrical power points of 6 Module (2nos of 15/5 A plug with switch x 2 board on each table length of min 1500 mm) supply running shelf connected to main lab table frame matching colour scheme with matching metal cabinet underneath with drawer/ shutter handles and lock & key arrangment. The pic enclosed is for reprentative purpose only. The agency shall submit the sample for approval before supplying in bulk, complete as directed and instructed.
Removing old film & Providing and fixing sun control films 1.5 mil thick garware film on window glasess without damaging rubber gaskets, handle , friction hinged etc complete including neccesary scafolding job is to be complited as per garware film specification and as directed by EIC
WOODEN CABINETProviding & fixing cabinet made up of 19 mm. Commercial ply of approved make for top, bottom, sides & shelves & 8mm commercial ply approved make for back side Door shutter made up of 19mm thick commercial ply and outer surfaces and top of shelves for open type cabine should be laminated with 1.5mm thick approved plastic laminate sheet of required colour including all brass fittings such as hinges, tower bolts, ball catches, stopper, handle, kNosbs as per shown in drawing or approved by Engineer-In-Charge etc.and all exposed edges lipping with 6mm Thick T.W. lipping patti.locking arrangement with Godrej multipurpose lock etc. all complete as specified & directed by Engineer-In-Charge.
Supply and installtion of factory made mlulded heavy duty Mid back plastic chair with bottom cushion and mesh for back with hand rest moulded heavy duty frame mounted on metal 5 leg castor wheel with with cushions finished of approved colour and shade. The bottom chushion with frame shall have heavy duty adjustable hydraulic post with level on side for height adjustament, One sample chair shall be supplied for approval before supply in bulk. The pic enclosed is for reprentative purpose only.
Supply and installtion of Low Back Visitor chair, mounted on powder coated metal frame, with bottom and back cusion fixed firmly to frame with matching hand rest complete as directed and instructed.One sample chair shall be supplied for approval before supply in bulk. The pic enclosed is for reprentative purpose only.
Supply & installtion of High seat Lab chair with or with out low back support, mounted on heavy duty powder coated metal frame with circuler leg support at bottom mounted on adjustable vertical post on 5 legged havy duty castor wheels. The colour of cusion shall be as per approved shade matching other chair and colour scheme.One sample chair shall be supplied for approval before supply in bulk. The pic enclosed is for reprentative purpose only.
Design, fabrication, supply & instalaltion of factory finished Lab working table with granite top of 1500 x 600/750/900 mm wide and table height from 750/900 mm with edge shamphered placed on 12mm thick marine ply fiXed firmly over dual colour powder coated metal frame, with movable drawer unit to fit underneath of mathcing dula tone coulr combination and with dedicated power point have electrical power points of 6 Module (2nos of 15/5 A plug with switch x 2 board on each table length of min 1500 mm) supply running shelf connected to main lab table frame matching colour scheme with matching metal cabinet underneath with drawer/ shutter handles and lock & key arrangment. The pic enclosed is for reprentative purpose only. The agency shall submit the sample for approval before supplying in bulk, complete as directed and instructed. :-Lab table 750mm width and 900 mm high
Providing and fixing Aluminium Composite Panel (ACP) curtain wall system of 4mm thick matching existing ACP Panel or approved colour and make fixing over aluminium frame of 50mm x 25mm thick in grid form including cutting bending, ACP to required size and shape, fixing on Aluminium frame with weather Silicon sealant and finishing the groove with black colour sealant as per manufacturer’s specification complete all inclusive of wastage, labour, shifting, transportation etc. as directed and instructed by Engineer incharge.
DEBRIS REMOVING:Removal of debris/murrum/stones etc. from ACTREC.premises including clearing the site/sweeping complete,carting away all materials out of the hospital premisesas specified & directed.double capacity truck
chilled water Ductable AC
Supply, Installation, Testing and Commissioning of chilled water Ductable ( Ceiling Suspended Duct able 3 Tr/Ceiling Suspended Duct able 11 Tr ) complete with G.I. casing, with Side/bottom return Air Plenum (5mm PE insulation) or as per site requirement (ABS casing) , Filter box with 8mm Nylon Filter, 3 Row Deep cooling coil with coper tube diameter is 9.52 mm and thickness 0.33 mm with hydrophilic Aluminium fins. Complete coil must be designed for standard working pressure is 1.6 MPa(16bar) and the test pressure is 3.3MPa(33bar). Unit to be provided with SS drain pan with 7mm PE insulation and +200 mm extended. Direct driven fan (three speed) motor, operated on 450 volts, Three phase, 50Hz, AC supply. Unit to be provided with Wireless remote. It shall also have RS485 Modbus communication function for BMS control. ESP for the Fan Coil Unit be 80 Pa Minimum( In case of 3 Tr, and 11 Tr) or Else Specified. Units need to BIS/Euro vent Certified. The unit included with Infrared Remote Control,micro-controller, drain pump & necessary supporting arrangement with ready made Valve Station with tray complete with butterfly Valves / Gate valves , 2 way Valves with Actuators, (Actuator and control make Siemens)–Strainer,Pressure cum balancing valves. The entire skid shall be coated with Zinc-chromate primer coating and then painted with enamel paint. Price should be included for Electrical cable connection from MCB/Isolator to chilled water unit shall be done by HVAC contractor. Pipe line require from the main header also to be considered with nitrile rubber insulation with GC cloth factory fitted as per manufacturer recommandation. no additional cost given for the same. Minimum Capacity should be as follows:
Design,Supplying, laying, fixing, testing and commissioning of following nominal sizes of pre insulated chilled water piping inside the building / outside the building along the wall/ roof (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) pipe insulation shall be polyurethane foam with minimum 36 kg/cum, 90% minimum closed cell content, minimum compressive strength of 2.7 kg/cm2 and initial thermal conductivity of 0.02 W/mK. The insulation shall completely fill the annular space between the service pipe and jacket and-shall be bonded to both, the service pipe & jacket. The minimum thickness of insulation and aluminium clading as specified/approved. Lock seam spiral Jackets for metallic jackets must be made on a spiral duct forming machine. The lock seam jackets should have zero leakage at the seams.
Note:-The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto Note:- Pipe line inside the room area should have proper cable tray with cover/PVC casing caping as per instructed as directed by OIC-ES price should be included for the same.
65 mm with 36 mm PUF thickness and 26 Gauge AI Cladding
50 mm with 36 mm PUF thickness and 26 Gauge AI Cladding
40 mm with 36 mm PUF thickness and 26 Gauge AI Cladding
32 mm with 36 mm PUF thickness and 26 Gauge AI Cladding
25 mm with 36 mm PUF thickness and 26 Gauge AI Cladding
Design, Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications and as per SMACNA standard of following sheet thickness complete as required. Hot dipped Galvanised with 120GSM Zinc coatingThe price shall include necessary scaffolding required for working at required height.
Thickness: 0.63 mm Sheet
Thickness: 0.8 mm Sheet
Supplying and fixing of 19mm thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Silver tap to be provided for final finishing of the duct insulation as per instructed and as directed by OIC-ES.
Supply & installation of Acostic insulation of thickness 15 mm
SITC of Extruded aluminium powder coated diffuser/ Grill with volume control damper with all necessary supports as per directed and as instructed by OIC-ES
Supply, installation, testing and commissioning of GI volume control duct damper/Non Return damper 18 guage GI. frame & 20 guage GI blades complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
SITC of Extruded aluminium powder coated diffuser/ Grill without volume control damper with all necessary supports as per directed and as instructed by OIC-ES
Supply, Installation, Testing and commissioning of PVC (minimum 15kg/sqcm pressure rated) drain water piping complete with fittings(elbows, tees, reducers,sockets,u trap etc.) supports, jointing insulated with XLPE class O tubular insulation and any other item required to make the system complete. Nominal diameters of pipe in mms as indicated below:
40 mm dia pipe, Insulation thickness - 6 mm
32 mm dia pipe, Insulation thickness - 6 mm
25 mm dia pipe, Insulation thickness - 6 mm
Supplying, Fixing,testing and commissioning of fusible link type fire dampers in supply air duct/main branch and return air path as and where required of required sizes . The damper shall also be closed in the event of fire complete as required and as per specifications.
Supply & fixing of Fire retardant synthetic canvass connection with a provision to measure the canvass temperature at the mouth of package units & plenum with all fixing arrangement, nut bolts, hardware’s etc. as instructed and as directed by EIC for above package units.
Dismatling Split Unit/chilled water FCU including piping, outdoor, indoor cabling , drain etc as per instruction and as directed by OIC-ES
Re-installtion of Split Units/chilled water FCU including gas charging and commissioning as per instruction and as directed by OIC-ES
Differential pressure monitoring system for Clean Rooms consists of magenehelic gauges with -30 to 30 mm of WC range including accessories including CRCA powder coated box and SS 304 top cover with all other necessary hardware as per instructed and as directed by OIC-ES
Electrical works
Supply, installation ,testing & commissioning the following cable on wall/floor/ceiling/structure member or on cable trays or down through PVC pipes, using MS spacers and GI saddles, cable clamp etc. complete in all respect. Cable, conforming to IS: 1554/Part 1/1998, XLPE, Aluminium stranded conductor, armoured, 1100 V class
SITC of 3.5Cx70 Sq.mm A2XFY Aluminium Conductorcable Incoming for VTPN
SITC of cable gland double compression type and PVC shroud on gland for 3.5x70sqmm aluminium cable
SITC of cable lugs for 70sqmm
SITC of cable lugs for 16sqmm
SITC of cable gland gland double compression type and PVC shroud on gland for 3.5x35sqmm aluminium cable
SITC of cable lugs for 35sqmm
SITC of cable lugs for 16sqmm
Supplying,erecting, testing & commisioning of 20 kVA capacity on line pure sine wave,PWM,IGBT based UPS with 0.9 to unity output pf ,3 phase input &3 phase output complete with all protections as per specification no. AP-UPS Including external batteries bank for 30 Min back up . interlinks , racks , battery breaker , rubber mat , earthing complete in all respect as per technical specification in tender.
SITC of Input / Output 63 AMP 4 Pole MCCB with metal enclosure , earthing and to be fix on wall.
SITC of 16sqmm copper cable flexible for UPS Input/Output connection with lug and glands
Tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like Cole, charcoal, salt, brass nut bolts & washers, watering arrangements, GI pipe (B class), concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. Etc. Note:1.The chamber cover & plate shall be of heavy-duty hinged type & it shall weigh approx. 65 to 75 Kgs. For 450 x 450 mm size & shall be got approved by dept. (6 mm chequred plate with 40 x 40 x 6 mm angle iron frame)2.Plastering shall be done both inside & out side.3.The measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by Engg-in-charge.
SITC of Copper strip of size 25 x 3 mm including all fixing arrangement and after installation the strip to be painted with black colour.
Power distribution board and Lighting distribution board NPDB 1 , EPDB 1 , UPDB 1 LDB 1
Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB in provided distribution board as per specification no. SW-MCB
Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB.
Supplying, erecting & marking SP MCB 16A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no.SW-MCB
Supplying & erecting triple pole and neutral distribution board 12 way (TPNDB), SPMCB of 24 Nos each ), with door, 1.2mm thickness surface/flush mounted, IP43 Protection provided on iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB
Supplying and fixing following ratings 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles including metal enclosure box , earthing and fixing accessories with connections, Testing and commissioning etc. as required. As per technical specifications in tender.
Supplying, erecting & marking DP MCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Supplying, erecting & marking DP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
Supplying, erecting & marking TP MCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB
SITC of DP MCB Enclosure box Metal type with all fixing accessories
SITC of TPN MCB Enclsoure box metal type with neutral link and all fixing accessories
Supplying and fixing surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of VTPN DB MCCB tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s, with provision of Incoming 160 amps 4Pole 16 KA MCCB and Outgoing , 63 A TPN MCB Qty 06 Nos and 40 A TPN MCB Qty 04 Nos , interconnection between incomer MCCB and bus bars as required and outgoing MCB . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
Incoming cable for Lighting DB
Supply, installation ,testing & commissioning the following cable on wall/floor/ceiling/structure member or on cable trays or down through PVC pipes, using MS spacers and GI saddles, cable clamp etc. complete in all respect. Cable, conforming to IS: 1554/Part 1/1998, XLPE, Aluminium stranded conductor, armoured, 1100 V class
SITC of 3.5 c x 35sqmm cable Aluminium armoured cable 1.1 KV
SITC of cable gland 35sqmm double compression type with black shroud
SITC of 35sqmm lugs
SITC of 16sqmm lug
Outgoing circuits of Power DB The installation to be concealed or recesss as per site requirement and civil work required for recess wiring is also included.
SITC of Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire including PVC HMS type conduicts , bends , and all fixing accessories ( Rate for one mtr circuit i.e. 3 x 2.5sqmm wire) for power points.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed HMS PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm including PVC HMS type conduicts , bends , and all fixing accessories earth wire FOR POWER POINTS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire including PVC HMS type conduicts , bends , and all fixing accessories FOR POWER POINTS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable including surface/ recessed HMS class PVC conduit as required. 3 X 4 sq. mm + 1 X 4 sq. mm earth including PVC HMS type conduicts , bends , and all fixing accessories wire FOR POWER POINTS
Point wiring for lighting
Supply ,Installation,Testing & Commisioning of LED shaped 36 Watt 2ft x 2ft Premium Range Recessed Downlighter having pressure die-cast aluminimum housing with white front bottom frame suitable to following features. LED fixture to be fixed surface of concealed as per site requirement. - Luminaires suitable to Aluminium metal grid ceiling or Gypsum or POP, -Minimum System Lumen output 1800 lumens -In built electronic LED pre wired driver, -Luminaire shall be with special translucent --High Surge Protection:-2.5kV. -High diffuser>85%, -Provision of Spring loaded Mounting clips. -Opal Translucent cover/Poly Carbonate reflector. -CRI>80,THD<10%. -High Efficacy gretaer than or equal to 100 lm/watt, -Provide Uniform low glare lighting non yellowing/PMMA lens for better light distribution, -Operatable voltage - 220-240 V,50 Hz, PF>0.9, -Colour Temperature gretaer than or equal to 4000K to 5000K LED concealed square type / round type , seemless, high efficiency and premium range as per technical specification directed by OIC - ES
SITC of 22W LED square / round light surface or recessed type with driver and all type of fixing accessories
SITC of UV Lights 4 ft with fixture and light.
SITC of wall fan high speed with all fixing accessories as approved by EIC ES
SITC of 1200 MM decorative type ceiling fan with ceiling rose , junction box , ceiling hook , anchor fastners ,and all fixing accessories
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
SITC of Primary point wiring for light point/ fan point/ exhaust fan point/ call bell point with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed including medium class PVC conduit Heavy(HMS) / casing capping , with modular switch , modular plate, suitable GI box for concealled , suitable PVC box for surface , ceiling fan rose , PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Average circuit lenght 20 mtr)
SITC Secondary point wiring light to light looping with 2 x 1.5sqmm + 1 x 1.5sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed including medium class PVC conduit Heavy(HMS) / casing capping , with modular switch, modular plate, suitable GI box for concealled , suitable PVC box for surface , ceiling fan rose , PVC junction box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. ( Average circuit length 10 Mtr )
Power Points
Supplying and fixing following size/ modules, PVC / GI box alongwith modular base & cover plate for modular switches in surface or recess etc. as required. • All the power socket tagging to be provided , PVC tags to be provided. • All the power sockets inside and power panel inside wiring ferruling to be done as instructed by EIC ES
3 Module
6 Module
8 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Modular switch 6A/16A
Modular Socket 6A/16A
SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS
SITC of CAT 6 LAN cable for DATA including 25mm PVC Conduit Supply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cable to TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required. All the cabe to be connected in IT rack with RJ 45 connector.
SITC of IT rack -19" Wall mounted rack 15U(double section , double door ) with acrylic glass door with the accessories -[Two Fan position tray with two 90 CFM fans(AC 230V),3 Horizontal cable manager- 3nos, AC power panel strip with 5 X 5 AMP /15Amp sockets ,fuse and on/off switch, 1 packet mounting hardware. Including 02 Nos Fiber LIU with OS2 Lazrspeed fully loaded fibre tray which includes LC TO LC adaptors, pigtails, splice protectors etc for the termination of 12 core Single mode fibre with suitable required numbers of fibre patch chords LCLC , LCSC (8 nos)having the compliance/certifications for ISO 9001:2015 & ROHS
SITC of fully loaded RJ-45 24 port Patch Panel with tool-less keystone jacks having the compliance / Certifications for ISO 9001:2015 & ROHS
Supplying and fixing (rack dressing) 1 meter length, UTP Patch cord of Cat 6A type in position having the compliance / Certifications for ISO 9001:2015 & ROHS.
Supplying and erecting 6 fibers LSZH armoured multimode optical fiber cable with, core dia 50/125 µm (OM3), suitable upto 10 GBPS, compliant to IEC 60793/IEC 60794 standards, on wall/ceiling or laid in provided pipe/trench as per specification no. WG-ELVC/OFC The scope also includes fiber splicing in LIU at both ends
Supplying and fixing (rack dressing) 3 meter length, UTP Patch cord of Cat 6A type in position having the compliance / Certifications for ISO 9001:2015 & ROHS.
Telephone
SITC of telephone instrument Called ID type panasonic.
SITC of Cat 6 type I/O with RJ 45 socket with Box, faceplate and fixing screws, having the compliance/certifications for ISO 9001:2015 & ROHS
SITC of CAT 6 LAN cable including 25mm PVC Conduit Supply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cable to TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required.
Supplying, erecting & terminating 50 pair telephone armoured copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, nylon rip cord & grey colour sheathed with FR PVC, confirming to ITD specification S/WS 113C laid in provided PVC casing-n-capping/conduit
Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TA including krone connectors installed in for connection of 50 Pair cable
SITC of CAT 6 LAN armoured cable for to be laid underground , wall , trench Supply ,Installation,Testing & Commisioning of of UTP 23 AWG 4 pair CAT 6 LAN Cable armoured type to TIA/ EIA 568 B.2.1.in the surface/ recessed steel/ PVC conduit as required.
Earthing
Tinned copper earth plate electrode 600 x 600 x 3.15 mm earth station, 2.5 mtr below ground level as per drawing complete with all required materials like Cole, charcoal, salt, brass nut bolts & washers, watering arrangements, GI pipe (B class), concrete chamber, heavy duty cast iron cover plate & excavation in all types of soil in ground refilling & removal excess earth within a radius of 500 mtr. Etc. Note:1.The chamber cover & plate shall be of heavy-duty hinged type & it shall weigh approx. 65 to 75 Kgs. For 450 x 450 mm size & shall be got approved by dept. (6 mm chequred plate with 40 x 40 x 6 mm angle iron frame)2.Plastering shall be done both inside & out side.3.The measurement of resistance of earth station & resistance of complete scheme of earthing layout shall be measured, recorded & got approved by Engg-in-charge. (Composite)
SITC of Copper strip of size 25 x 3 mm
Exhaust fan Reversible Air Flow: Ability to both expel indoor air and draw in fresh outdoor air High Speed: Fast Operation & Quick Relief Strong Metal Body: Longevity Rust Free Bird Guard 100 % Copper Motor Auto Thermal Protector , Outside louvers necessary modifications required like , wall openings , wooden frame is in the scope of agency with all fixing accessories like anchor fastners etc.
SITC of exhaust fan 225 mm
SITC of exhaust fan 300 mm
SITC of exhaust fan 450 mm
Access control system
SITC of access control system including in out machine bio matric type asper technical specifications in tender documents 50 Nos access card to be provided
Removing of existing switch sockets , MCBs fans , lights , fire accessories , wirings , conduicts , Networking accessories and other electrical accessories as per satisfaction of EIC The existing wire in good condition may re routed and re used as directed by EICES the cost of the same included
SITC of 3 Ltr Gyser with all fixing accessories IN OUT metal pipe line and heavy duty.
SITC of floor raceway concealed / surface type , SS /GI including floor cutting for electrical wirings from wall to working table on floor and finishing of the same , size 50mm to 150mm. No screws – snap fit assembly of cover speeds up the assembly and removal of cover, if required; Lighter unit weight is easier to handle,
Fire Alarm System
Supplying, installing, testing and commissioning of Addressable Optical Photo Smoke Detector. The detector shall have multi co-operative sensing technology for faster response & avoid false alarms. The detector shall have single/twin bi-colour LED for 360 deg viewing. The detector is conforming to IS 2189: 2008, 11360_1985_Reff2020_EN 54 /VdS / UL & FM approved with 3 years equipment replacement warranty, Designed to meet UL268, 7th Edition. FF- AFAS/SD.
Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI
Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with "Break Glass" massage embedded on the glass, complete erected with mounting base and required accessories, Module shall conform to EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MCP.
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
SITC of 2c x 1.5 Sq.mm FRLS Unarmoured cable. ATC conductor stranded, PVC insulated to form a core, Cores laid up, Overall shielded with Alu-mylar tape with tinned copper drain wire of size 0.5 Sq. mm, PVC innersheathed, PVC sheathed cable (Colour: RED )
Supplying, installing, testing and commissioning of addressable fire monitor module for flow switches, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982 Reed relays, EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/MM
Supplying, installing, testing and commissioning of addressable fire isolator module for isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the health status of the device. module complete as required. Module shall conforming to IS 5051 Part 2 (Sec 1 to 3) : 1982, , EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, FF-AFAS/ISM
Supplying, installing, testing, commissioning of Power Supply Unit of suitable rating for hooters.
For 4 Hooters
Supplying, installing, testing and commissioning of Addressable Sounder cum Strobe rated at minimum 75 dB @ 3m for Audible annunciation and minimum 75cd flashing at 1 Hz for visual indication. Module shall conforming to IS 2189: 2008, IS 15908:2021 / EN 54/VdS / UL & FM approved with 3 years equipment replacement warranty, as per specification no FF-AFAS/ S-ST
SITC of 2.5sq.mmx3 wire FR-LSH for providing power points to power supply units of LV system with 25mm HMS PVC conduit.
Reprograming of new fire alarm devices with new fire alarm system including all nesscery devices
ask enterprises (BID ID -3259543)
PARNAVI ENTERPRISES (BID ID -3256670)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .