| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹58.4 CrAccepted-AOC | ₹58.4 Cr Quoted ₹58.9 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹64.0 CrRejected-Finance C O EROS PALA EAST LABAN ROAD SHILLONG 793004 | EAST KHASI HILLS | MEGHALAYA | 793004 | ₹64.0 Cr | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹70.0 CrRejected-Finance | ₹70.0 Cr | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹78.8 CrRejected-Finance | ₹78.8 Cr | L4 | Rejected-Finance Being other than L1 |
| 5 | Rejected-Technical SCF 126 OPP SUKHRAJ CINEMA ROSE GARDEN COMPLEX G T ROAD BATHINDA PUNJAB 151001 | BATHINDA | PUNJAB | 151001 | - | - | Rejected-Technical Not approved |
| Sl No | Description | Qty | Unit | Pawansut Infra Projects Pvt. Ltd. L3 | ENGINEER CONSTRUCTION PVT. LTD. L1 | Rabina Enterprises Pvt Ltd L4 | S K CONSTRUCTION L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the tenderer for “BUILDING WORK" as listed in Schedule ‘A’ Part - I | 1 | Lump sum | 58,60,00,000 ₹58.6 Cr | 49,00,00,000 ₹49 Cr | 65,76,56,306 ₹65.8 Cr | 53,50,98,314 ₹53.5 Cr |
| 2.00Subtotal | |||||||
| 3.00 | Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Part -II | 1 | Lump sum | 35,00,000 ₹35 L | 30,00,000 ₹30 L | 31,73,557.24 ₹31.7 L | 19,99,341.06 ₹20.0 L |
| 4.00Subtotal | |||||||
| 5.00 | Lump sum price worked out by the tenderer for “Fencing works" as listed in Schedule ‘A’ Part - III | 1 | Lump sum | 20,00,000 ₹20 L | 20,00,000 ₹20 L | 21,17,130 ₹21.2 L | 14,70,861.4 ₹14.7 L |
| 6.00Subtotal | |||||||
| 7.00 | Lump sum price worked out by the tenderer for “ROAD , PATH & CULVERTS WORKS" as listed in Schedule ‘A’ Part - IV | 1 | Lump sum | 1,25,00,000 ₹1.3 Cr | 1,15,00,000 ₹1.1 Cr | 1,33,62,824.6 ₹1.3 Cr | 77,50,480.26 ₹77.5 L |
| 8.00Subtotal | |||||||
| 9.00 | Lump sum price worked out by the tenderer for “Sewage disposal worksY" as listed in Schedule ‘A’ Part -V | 1 | Lump sum | 1,45,000 ₹1.4 L | 2,00,000 ₹2 L | 1,57,320 ₹1.6 L | 98,496 ₹98,496 |
| 10.00Subtotal | |||||||
Tender Value
₹73.7 Cr
EMD Value
₹15 L
Closing Date
6 May 2026, 6:00 pmClosed
Chief Engineer Bathinda zone
HQ CE Bathinda Zone, Bathinda Mil Stn-151004
PROVN OF DEFICIENT JCOS AND ORS MARRIED ACCOMMODATION AT SRIGANGANAGAR ON EPC MODE
2026_MES_759182_1
84576
Open Tender
Civil Works
548 days
GE Sri Ganganager
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
GE Sriganganagar
₹15 L
Yes
13 May 2026
4 Apr 2026
8 May 2026
4 Apr 2026
6 May 2026
30 Apr 2026
4 Apr 2026 - 30 Apr 2026
Lump sum price worked out by the tenderer for “BUILDING WORK" as listed in Schedule ‘A’ Part - I
Subtotal
Lump sum price worked out by the tenderer for “AREA DRAINAGE WORKS" as listed in Schedule ‘A’ Part -II
Subtotal
Lump sum price worked out by the tenderer for “Fencing works" as listed in Schedule ‘A’ Part - III
Subtotal
Lump sum price worked out by the tenderer for “ROAD , PATH & CULVERTS WORKS" as listed in Schedule ‘A’ Part - IV
Subtotal
Lump sum price worked out by the tenderer for “Sewage disposal worksY" as listed in Schedule ‘A’ Part -V
Subtotal
Lump sum price worked out by the tenderer for “SITE CLEARANCE & DEVELOPMENT, EXCAVATION AND EARTHWORK WORKS" as listed in Schedule ‘A’ Part -VI
Subtotal
Lump sum price worked out by the tenderer for “Fire fighting and fire alarm WORKS" as listed in Schedule ‘A’ Part -VII
Subtotal
Lump sum price worked out by the tenderer for “LIGHTENING PROTECTION WORKS" as listed in Schedule ‘A’ Part -VIII
Subtotal
Lump sum price worked out by the tenderer for “ EXTERNAL WATER SUPPLYWORKS" as listed in Schedule ‘A’ Part -IX
Lump sum price worked out by the tenderer for “EXTERNAL ELECTRIC SUPPLY WORKS" as listed in Schedule ‘A’ Part -X
Subtotal
Lump sum price worked out by the tenderer for “DEMOLITION AND DISMANTLING WORKS" as listed in Schedule ‘A’ Part -XI
Subtotal
Schedule ‘A’ Part -IX MISCELLANEOUS WORKS
M&L for DWCPE (SN8) 150 (OD)/125(ID) mm pipe conforming to IS-16098 complete laid in trenches and jointed alongwith necessary jointing materials etc complete laid complet all as specified.
M&L for DWCPE (SN8) 200 (OD)/175(ID) mm pipe conforming to IS-16098 complete laid in trenches and jointed alongwith necessary jointing materials etc complete laid complet all as specified.
M&L for DWCPE (SN8) 300 (OD)/275(ID) mm pipe conforming to IS-16098 complete laid in trenches and jointed alongwith necessary jointing materials etc complete laid complet all as specified.
Disconnecting and taking up serviceable HT underground cable of any type from the ground, wall, floor etc and resifting the same HT cable complete all as specified and as directed.
Supply, installation, testing and commissioning of distribution net work, 11 kv outdoor compact Sub Station totally factory assembled, consisting of 3 Way (2Nos.Isolators+1No. Breaker))- 1 set. 11KV/433V, 1000 KVA with Oil type transformer, 1 set of LT device as under. Approved Makes - Schneider, Siemens, ABB
MV COMPARTMENT 11 KV, 800A, 25KA/1Sec indoor type non-extensible, SF6 gas insulated Ring Main unit with sealed pressure system criterion in accordance with the IEC: 60298,62271 - 202.IAC category Iac-AFLR .The Switchgear includes the following HV cubicles
The indoor non -extensible SF6 insulated RMU fully motorised consist of 3 Way ((2Nos.Isolators+1No. Breaker) with self powered relay for protection of transformer . Rated for Voltage 12kV, 800A, 25 KA for 1 sec.
Rated voltage should be - 12 KV
Rated power frequenecy voltage - 28 KV
Rated lightening withstand voltage - 75 KV
Rated current for Ring main feeder - 800 amps
Rated current for VCB feeder - 800 amps
Rated short time current - 25 KA / 1sec
Rated short time making current -50 KA
Ambient temp ( 0 deg C to +40 deg C)
Rated internal arc rating - 20 KA for 1 sec for tank and cable box category IAC-AFL
RMU shall be provided with protection CTs rated for 30 / 1amps, class - 10P10 accuracy , 2.5 VA burdan for circuit breaker
The circuit breaker feeder shall be self powered/powered by external source and shall be provided with OC+EF protection for transformer and shall have serial port for communication on modbus protocol.
Dead short Circuit life of VI - 40 no
Transformer (Oil Type) Three phase, Approved Makes- Schneider, Siemens, BHEL, Hitachi
LT switchgear and Transformer should be of same make for better co-ordination and safety.
Standard: IS : 2026, IS 1180
Vector group : Dyn11
Rating : 1000 KVA
Cooling System: ONAN
Winding: Copper
Magnetic Core: Prime grade of M4 or better
High voltage : 11KV - 50 Hz
System highest voltage : 12kV at the HV side
H.V. Power Frequency (KV rms): 28 kV
H.V. Impulse withstand voltage (KV peak): 75 kVp
The Losses of Transformer should be as per IS 1180 part 1 Eff level 2 norms
Transformers shall be designed for 110% continuous overfluxing withstand capability
Temperature rise as per IS1180
OTI & WTI,Pressure relief valve (without auxiliary contacts),Skids,Earthing terminal,Lifting lugs,Rating plate,Dehydrating breather
LV COMPARTMENT The LV compartment with Degree of protection-IP54 designed for a 50 degree C ambient temperature. The panel is modular, dead front, freestanding, floor mounted and comprises the following equipment
433 V Air Insulated Aluminium busbar having capacity 800A, 50Hz,50KA withstand fault level capacity, MFM - EM6400NG in incomer
Incomer - 2nos - 4 Pole, 800A, Microporcessor based ACB, rated operational voltage of 415V AC, rated insulation voltage of 1000 volts AC, rated impulse voltage of 12kV, 50 KA Icu=Ics=Icw for 1 sec @440V with LSIG Protection, % load indication of each phase display on the release, No-derating upto 50 Degree Celsius and with Inbuilt ZSI feature. (Schneider,Siemens, L&T )
Inbuilt 350KVAR, APFC Panel
Outdoor Enclosure :- The enclosure shall be made of 2.0 mm thickness Galvanized Sheet Steel tropicalised to meet Indian weather conditions including all the partition sheets & doors.The base of the enclosure shall be of 4.0 mm thickness Hot Dip Galvanized Sheet Steel to ensure rigidity for easy transport & installation. The entire Package Substation shall be Factory Assemble & Factory Fitted. The enclouser shall have IP54 degree of protection for HT & LT switchgear compatment IP34 degree of protection for Transformer compartment. The Enclosure to be tested for Internal Arc fault test to the tune of atleast 21 KA for 1 second A&B, adhering to as per latest IEC 62271-202.The temperature rise test on enclosure for K10class.The enclosure exterior shall be powder coated.Only OEM make of CSS is accetable.The compartment illumination lamp with door operated switch shall be provided for MV & LV comparatment. The encloser, RMU and LV Breaker should be of same make for better co-ordination and services. HT/LT Switchgear should be of same make for better co-ordination.
Supply Install Testing and commissioning of 11 KV, 630 Amps, HT vacuum circuit breaker indoor panel shall be constructed from Aluminium Zinc coated sheet steel of 2mm thickness, for 1 Incomer and 2 outgoing conforming to IEC 62271-200, 25 KA for 1 Sec, LSC2B-PM class front accessed comprising of Indoor Vacuum Circuit Breaker all as specified and directed with Electrical & Mechanical interlock. Enclosed panel shall consisits of following :- (a) 800A continuous ratedelectrolytic copper bus bar, droppers and bus bars should be insulated with full system voltage sleeves (b) VCB shall be of horizontally draw out type . VCB shall have provision of spring Charging Handle, Trip Road and VCB have Rack in & Rack out mechanism. Vacuum circuit breaker should have vacuum bottles of the same manufacturer as of circuit breaker. The Vacuum Bottle should be type tested for 100 full short circuit operations. (c) Motorized spring charging mechanism with integral spring charging handle for manual spring charge.(d) Panel separation with every department like VCB, Metering , Cable Chamber & Bus Bar Chamber (e) Cast resin Current Transformer 11KV, 300-150/5+5A, core 1: class 0.5, 15 VA, Core 2: 5P10, 15 VA with metering and protection core including necessary control wiring & PotentialTransformer 11 kV,Core I : CL 3P,Core II : Cl 0.5,VA Burden : 50 VA OVF 1.9 for 30 Sec. for metering & protection for incomer and outgoing backed by HT & LT MCB's. Line PT should be mounted only in the rear side ( Top or Bottom)of the Panel
(f) Accessories like local remote switch, breaker control switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF, breaker in SERVICE/TEST.(g) Multifunction meter with RS 485 port ( EM6400 ng). (h) Digital Ammeter and Digital Voltmeter. (i) Separate master trip Relay and anti-pumping relay. (j) Wireless thermal sensor will be provided in each bus & each cable termination per panel, along with Zig- B concentrator and the data of the same should be display on HMI, other necessary arrangement to be consider. (k) Battery bank 24 Volts DC-12 Nos tubular maintenance free batteries 2 Volts 100AH including charger (k) Comprehensive numerical protecting relay( ABB- REL series/Schneider-Easergy Series, SIEMENS-Siprotech series) should have built-in integrated mimic compatible with IEC 61850 for non-directional O/C, E/F, U/V, O/V protection type having followed additional facilities :-(i) Trip ckt supervision.(ii) Distribution recorder. (iii) Event log with date and time. (iv) Conformal coating for harsh environment. (v) Suitable to operate on 24 volts DC for auxiliary and control supply. (l) Panel should also have additional facilities :- (i) Only OEM panels are to be supplied. Partner or franchises are not accepted. (ii) Fully internal arc type tested (25 KA for 1 Sec-AFLR) as per latest IEC 62271-200. (iii) Vacuum bottles should be tested for 100 full short circuit operations.(iv) Manual closing/ tripping of CB with compartment door closed. (v) The panel shall be provided with power pack battery backup for not less than 10 minutes.(vi) Arc Flash Relay should be in each way to detect and rapidly clear arc faults in electrical systems. (vii) Breaker shall be provided with following contacts.(a) Auxiliary switch with 6NO+6NC mounted on the draw out portion of the switchgear.(b) Position switches with 3 NO+1NC contacts for each position in SERVICE and TEST.
Make of HTPanels are ABB- ZS1, BHEL, SCHNEIDER-PIX , SIEMENS - NX-AIR Note : The panel shall be SCADA Compatible system. The Vacuum Interrupter, Breaker & Panel along with Relay should of same make for better coordination. and better SCADA compatibility. Bus Coupler compartment doesn’t carry numerical protection relay, PT, Voltmeter & arc flash relay in their compartment and a bus rises is required with bus coupler. Outgoing compartment don’t carry PT & Voltmeter
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (Main LT Panel No-1)
INCOMINGS
(a) ACB 415 Volts,800 Amp rating,50 KA, 4 Pole - 01 No
(b) 1200 Amps Copper bus bar 6way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB Adjustable thermal and fixed magnetic 415 Volts,160 Amp rating,36 KA, 4 Pole - 06 Nos( 1 no spare ) (for BlockNo-1,2,3,6 & 7)
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (Main LT Panel No-2)
INCOMINGS
(a) ACB 415 Volts,630 Amp rating,50 KA, 4 Pole - 01 No
(b) 1000 Amps Copper bus bar 6way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB Adjustable thermal and fixed magnetic 415 Volts,315 Amp rating,36 KA, 4 Pole - 03 Nos( 1 no spare ) (for BlockNo-4,5 & Lift panel)
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (Main LT Panel No-1)
INCOMINGS
(a) Micro processor based MCCB 415 Volts,315 Amp rating,36 KA, 4 Pole - 01 No
(b) 500 Amps Copper bus bar 6way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB Adjustable thermal and fixed magnetic 415 Volts,63 Amp rating,16 KA, 4 Pole - 08 Nos( 1 no spare ) (for BlockNo-1 to 7 Lift panel)
(b) MCCB Adjustable thermal and fixed magnetic 415 Volts,40 Amp rating,16 KA, 4 Pole - 01 No(for Mono block pump set 15 HP)
(c) MCB TPN 415 Volts,16 Amp rating,10 KA, 4 Pole - 01 No(for Street light)
(d) Street light timer 5 KW including all accessories(MCB,Contactor,timer etc) nature switch type
Suppyling, installing, testing and commissioning of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (LT Panel near block No 4 & 5)
INCOMINGS
(a) Micro processor based MCCB 415 Volts,315 Amp rating,36 KA, 4 Pole - 01 No
(b) 500 Amps Copper bus bar 3 way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB Adjustable thermal and fixed magnetic 415 Volts,160 Amp rating,16 KA, 4 Pole - 03 Nos( 1 no spare ) (for Block No-4 & 5 )
Suppyling, installing, testing and commissioning of factory made Indoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 2 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (Main LT Panel of lift)
INCOMINGS
(a) Micro processor based MCCB 415 Volts,63 Amp rating,16 KA, 4 Pole - 01 No
(b) 100 Amps Copper bus bar 3 way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB fixed thermal and fixed magnetic 415 Volts,32 Amp rating,16 KA, 4 Pole - 02 Nos( 1 no spare ) (for Block No-1Lift panel)
(b) MCCB fixed thermal and fixed magnetic 415 Volts,20 Amp rating,16 KA, 4 Pole - 01 No
Suppyling, installing, testing and commissioning of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :- (LT Panel for existing 3 block OR Qtr)
INCOMINGS
(a) Micro processor based MCCB 415 Volts,160 Amp rating,36 KA, 4 Pole - 01 No
(b) 250 Amps Copper bus bar 8 way for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
OUTGOINGS
(a) MCCB Adjustable thermal and fixed magnetic 415 Volts,40 Amp rating,16 KA, 4 Pole - 08 Nos( 1 no spare ) for existing 3 block OR Qtr)
S&F Hot Dip Galvanized octagonal pole (7 Mtr long) Top dia -70 mm , Bottom Dia -130 mm, Thick -3mm , base plate -220 mm x 220 mm x 12 mm with 1.5 mtr single Arm HDG OD-48.3 F.Bolt 4 Nos. 20x 600 mm. including foundation as per coy standard specification and approved Drg including suitable three phase bus bar connection with 6 Ams MCB complete all as specified & directed by Engineer-in-Charge.
Supply & fixing copper cable multistrand PVC insulated PVC sheathed 2.5 Sqmm 3 core all as dircted by Engineer-in-Charge.
S&F cable route indicator of size 100mmX100mmX05mm thick GI plate with insertion there on bolted welded to 35mm X 35mmX 6mm angle iron 60 cm long and frouting the sae in ground with PCC as required for LT/HT cable incl necessary earth work all as specified and directed.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32X6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover in 1:2:4 type B1using 20mm graded crushed stone aggregate and reinfircement (TMT) with 8mm dia @ 100 c/c bothways & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, complete all as specified & shown in electrical plate No. 3 of MES schedule Part-I. Note:(i) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. (ii) PCC chamber shall be construced at least 1.50 m away from the earth electrode and pipe for watering shall be provided in slanting manner.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply and laying DWC pipe of size 50 mm bore (ID), ISI marked,laid in trenches, under road, insert under holes for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
Supply and laying DWC pipe of size 76 mm bore (ID), ISI marked,laid in trenches, under road, insert under holes for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
Supply and laying DWC pipe of size 103.5 mm bore (ID), ISI marked,laid in trenches, under road, insert under holes for cable protection complete all as specified and as directed. (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
Taking out/down unserviceable, defective any Type/size cable including disconnecting/dismantling all the electrical connections all as required at site and all as directed.
Design, Installation, Testing, Commissioning including Integration and Maintenance of theAdvanced Metering Infrastructure (AMI) with procurement of all necessary software, programming licenses, and documentation with having specifications and comprising of following :-
Supply/ planning/setup/ tuning of GPRS/RF or combination of both communication infrastructure including network management system (NMS) & Head End System (HES) for the project area. AMI software and associated equipment’s should be capable of handing at-least 222 nos of single phase meters of different makes as per BIS 16444 (Part-I) with 25% expansion without any additional infrastructure and cost implementation to the dept. It shall support occupation/vacation, meter replacement, personal details update on email to user/staff. Bank details of GE and payment gateway would be integrated with the software and also calculation of refund on vacation of quarter. Software would adopt meters and system of minimum three different makes conforming with IS 16444. Software would compatible for both prepaid and postpaid billing plans as per requirement including user friendly app (Android & IOs) for Smart Phone. RF gateway shall be compatible with atleast 03 different makes of smart meter
Supply and set-up of Meter Data Management (MDM) system.
Integration of different devices of different makes/ equipments/software covered in scope of this project with each other as per functional requirements, including water charges, furniture and license fee.
Integration /Interface of the AMI system with application systems like metering/billing/collection. Interface has to be provided in the proposed solution to upload and process meter data from these systems.
Server for housing and management of supplied software application with standby server.
Planning, deployment and tuning of communication system including cellular network (if required) to meet the performance requirements.
Business intelligence, Analytics and Reporting.
Return of Dismantled materials to MES stores
Training knowledge transfer.
All expenditure including periodic charges of telecom, operator from installation till completion.
Bidder may go through the details for design of system as per PS and E-in-C’s Branch policy No. 12/2023 alongwith other details /policies as per CEA/TRAI/NSGM.
Note:- (a) The defect liability period will be 2 years from the date of completion of phase-I. (b) Audit of software for smart meters will be done by CERT-India empanelled firm/CERT auditor of Armed Forces. The cost of the audit will be borne by contractor.
Phase-II
Provision for comprehensive operation including periodic charges of telecom operator, smart meter biling from completion of work till the completion of defect liability period of 02 years.(No of meters- 222NosX24 months)
Phase-III
Comprehensive oeration and maintenance of system including project implementation and management , all expenditure including periodic charges of telecom operator, smart meter billing and maintenance after completion of defect liability period till completion for 8 years extendable to further 02 years after mutual agreement. (No of meters- 222 NosX96 months)
Supply, installation, testing and commissioning of "Silent type" (accoustic enclosure type as per NBC 2016), as per CPCB- IV+ compliant or latest CPCB norm, Diesel engines shall be as per MOEF (MINISTRY OF ENVIRONMENT, FOREST AND CLIMATE CHANGE) notification dtd. 3rd November 2022.Diesel Engine driven Generating set of capacity 200 KVA, 415 Volts 3 phase 4 wire 0.8 power factor and 1500 RPM at NTP electrical start, directly coupled and mounted on common base frame with coupling of suitable size to water cooled turbo charged diesel engine of suitable BHP as per IS: BS5514 / ISO 3046 and alternator as per IS-13364, IS/IEC:60034-1 complete with foundation, AVM pads, control panel, fuel tank of suitable capacity with fuel lines of heavy duty MS pipe duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and suitable batteries of capacity as recommended by manufacturer fixed on angle iron frame with necessary meters and sound proof canopy and separate battery charging system of suitable capacity with all standard accessories, tool box and tools as provided by the manufacturer complete all as specified and directed.
(A) Prime Mover: Vertical diesel engine of suitable capacity water cooled,Radiator mounted close circuit as per BS 649 , IS 10002 , ISO- 8528 or equivalent direct injection type turbo charged. The DG set shall be capable of running 24 hours on full load. Engine shall be equipped with all standard fittings as permanufacturer's recommendation and mounted on common base frame with following:- (a) RPM cum Hour meter (b) Battery charging alternator with inbuilt regulator (c) Ignition and starting keys with push button switch (d) Lubricating oil pressure gauge, oil and water temperature gauges (e) Batteries as recommended by manufacturer with battery leads of suitable size of copper cable (f) Self starter motor of suitable capacity (g) PCC Foundation for Generating set as per recommendation of manufacturer (h) Exhaust pipe duly insulated with asbestos rope for thermal insulation (j) Exhaust silencer industrial type to maintain noise level (k) Over speed indication (l) Low lubrication, oil trip indication (m) Engine Hours indication (n) Digital Amp meter and Voltmeter
(h) Instrument fuses and control wiring – 01 set (j) Auto / Manual test switch – 01 No (k) Under Voltage relay – 01 No (l) Digital electronic multification metre (Timer) – 01 No (m) Over load relay (n) By pass arrangement with rotary by pass switch AC 4 pole suitable Amp rating to isolate AMF Panel. (o) Four pole power contactor of suitable capacity for 200 KVA DG Set. (p) Automatic Battery Charger - 01 No, SMPS based inbuilt, auto/ manual and float/ boost facility. (q) Microprocessor based power command control for DG set monitoring, metering and control having protection of over current short circuit, high / low voltage, under/ over frequency, reverse power, excitation protection, field failure relay, differential relay all as specified.
(D) Fuel Tank:- Fuel tank of suitable capacity as per manufacturer's instructions suitable to store for 12 hours running of DG set mounted inside accoustic enclosure and including all fuel connection lines with heavy duty MS pipe from fuel tank to DG set as per manufacturer designs. (E) Base frame and Installation:- Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement, which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendation of manufacturer. (F) Exhaust system:- Dry exhaust manifold with hospital exhausts silencer and exhaust gases treatment system as per CPCB IV+ compliant or latest norms. (G) Starting System:- As recommended by Manufacturer DC starting comprising of starter motors. (H) Voltage regulator and arrangement for initial excitation complete with suitable Nos of batteries as required as per specification. (I) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine and alternator, discharging hot air in to the atmosphere as per specifications.
Note:- Contractor shall submit test report of engine and alternator as per Indian Standard IS 10000, IS 10001 and IS 4889: 1968. However if engine and alternator are tested more stringently (compared to IS 10000, IS 10000-1 1980, IS 13364 and IS 4889: 1968), then the parameters where the greater stringency has been applied should be declared by the manufacturer in the test report.Contractor shall submit CPCB compliance report/ certificate for complete DG set.
Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32X6 mm (upto the body of equipment) by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover in 1:2:4 type B1using 20mm graded crushed stone aggregate and reinfircement (TMT) with 8mm dia @ 100 c/c bothways & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, complete all as specified & shown in electrical plate No. 3 of MES schedule Part-I. Note:(i) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate. (ii) PCC chamber shall be construced at least 1.50 m away from the earth electrode and pipe for watering shall be provided in slanting manner.
8 Passenger(544Kg) Lift
13 Passenger(884Kg) Lift
Following are applicable for both lifts :-
Suppy,installation,testing,commissioning,putting into operation and final testing of automatic lift complete in the shaft well and pit constructed including automatic rescue device(ARD),all standard equipments,accessories and control equipments as per manufacturer design ,conforming to NBC/Statutory norms and fulfilling the following requirements.(Make:Schindler/Otis/Johnsons)
(i) Type: Passenger lift
(ii)Load:As specified elsewhere from 2 passenger to 13 Passenger for 13 Passenger lift and 2 passenger to 8 passenger for 8 passenger lift (For each person standard weight 68 Kg)
(iii) Speed:1.00 to 1.5 Meter/Sec
(iv) Control: ACV3F,32bit Microprocessor integrated serial communication control system with RMS(Remote Monitoring system)/BMS(Building monitoring system) supporting software
(v) Motor/Machine:Permanent magnetic synchronous gearless motor
(vii) Total rise: Near about 32 Mtrs (Approx) 9 stops only
(viii) Landing: All floors on the same side
(ix) Floor Served:G+8
(x) Signals:Digital car position indicator,car travel direction indicator inside car&at all landings,voice annuciator with suitable music shall be provide in the lift car
(xi) Shaft size:As per manufacturers design specification,Shaft to be constructed separately
(xii) Guide rail:As per manufacturers specification
(xiii) Lift and car size:As per manufacturers specification
(xiv) Car entrance:As per manufacturers specification
(xv) Car door: S.S(Stainless steel)Hairline finish centre/Telescopic opening door with vision panel
(xvi) Landing door: S.S(Stainless steel)Hairline finish centre/Telescopic opening door with vision panel
(xvii) Door Operation:Automatic electric power operated door,full height infra red curtain with multiple criss/cross light beams
(xviii) Car interior: S.S(Stainless steel) panel with hair line finish on all sides.
(xix) Car floor: Anti skid PVC flooring on heavy duty MS(Mild steel) platform
(xx) Car ceiling &lighting:S.S(Stainless steel) finish with aesthetic appearance with LED ceiling lights
(xxi) Car Ventilation: Pressure fan/blower fan(Car fan with automatic sleep timer shall be provided)
(xxii)Emergency lighting in car: Battery operated emergency lighting in the lift car
(xxiii) Intercom system : battery operated Intercom system in lift car,machine room and ground floor/control room
(xiv) Emergency alarm: Battery operated alaram bell system in lift car &control room/ground floor.
(xxv)Position of machine room: Directly above the hoist-way
(xxvi) Electric power supply:AC 415V,3phase 50 Hz &AC 230 V 1 phase 50 Hz terminated in machine room
(xxvii) Fire man switch: Fire man switch at machine room/terminal landing
(xxviii) All car panel buttons and all floor switches must be witrh brail language as per lift act.
(xxix) Audio visual indication in the lift car showing overloading shall be provided such that doors kept open till excess load removed.
(xxx) Spring buffer/hydraulic buffers shall be provided.
(xxxi) Mechanical over speed governor,door key holes in the floor doors shall be provided.
(xxxii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency,along with the other steel structure works,foundations for the machines etc.
(xxxiii) In the hoist way fascia plate shall be provided.
(xxxiv) Permanent writing in the lift machine room and lift well with proper no. of light point,with fixtures,exhaust fan,plug point and 3 phase 440V power supply shall be made available by the department in the lift shaft,machine room or at desired level.
(xxxv) Car top safety barricade shall be provided.
(xxxvi)ARD(Automatic rescue device):Solid state inbuilt automatic rescue device(ARD) for automatic rescue passengers trapped in the lift car in between floors in the event of power failure.Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing,opens the automatic door of the lift car and floor.Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles , equiptment or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed.
M&L for earthing complete with copper plate electrode 60 cm x 60 cm x 3 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to copper strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position
Supply, installtion, , commissioning and testing storage type vertical type of capacity 25 ltrs suitable operate /function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-off BEE approved 5 star rated including fixed along walls with all fixing material required at site and electric connections with copper cable 3 cable 3 core plug top 15A, safety valve, thermostate, NRV, hot and cold PVC connection piece including making good to disturbed surface complete all as specified and directed by Engineer-in-Charge .
Supply and fixing of Epoxy Earthing Strip Insulator, For Electrical Installation, Size: 25 mm X 3 mm every one meter gape from above earth pit to roof of shed
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position
Supplying, laying, jointing, commissioning and testing 150mm (6") bore centrifugally cast (Spun) ductile iron pressure pipe with flanged ends including rubber gasket class K-9, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Excavation / earthwork shall be paid separately under respective items .
Supplying, laying, jointing, commissioning and testing 150mm (6") bore centrifugally cast (Spun) ductile iron pressure pipe with flanged ends including rubber gasket class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Excavation / earthwork shall be paid separately under respective items .
Supplying, laying, jointing, commissioning and testing 100mm (4") bore centrifugally cast (Spun) ductile iron pressure pipe with flanged ends including rubber gasket class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Excavation / earthwork shall be paid separately under respective items .
S&F gun metal globe or gate valve 80mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
S&F Cast Iron foot valve for 80 mm bore pipe, lift flanged type as per IS-4038 complete all as specified and directed by Engrineer-in-Charge.
Supplying, Installation, commissioning and testing of centrifugal pump set, electic motor driven, not less than 18.40 LPS at 40 mtr head in load, suitable for pumping treated water, comprising of the following specification:- (i) Pump, centrifugal, horizontal not less then 18.40 LPS discharge, at 35 mtr head, 1440 RPM having bronze impeller and stainless steel shaft single stage directly coupled with electric motor through flexible copling (ii) Squirrel cage indication motor, TEFC, 3 phase 415 + 10 volts, 50 C/S AC supply 1440 RPM, not less then 15 HP directly coupled to centrifugal pump. (iii) Common base foundation of ISMC - 100 suitable for installation of above pump set duly drilled holes and painted with two coats of synthetic enameled paint over a coat of red oxide primer. (iv) Above ISMC foundation shall be grouted in PCC 1:3:6 type C-2 using 40mm graded aggregate, 30 cm above GL and 15 cm below GL and as per size of common base foundation / standard Engg practice or as directed by Engineer-in-Charge. (v) Boudrons type pressure gauge 3" dia dial type. Make :- Kirloskar Brothers Ltd / Beacon / KSB / Jyoti Note :- Sluice valve & reflux valve, DI pipe and fittings etc required for suction and delievery and common header etc shall be measured & paid separately in respective items.
Material and labour for Construction of brick masonary valve pit chamber size 1200 X1200 X1200 mm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-charge.
Material and labour for Construction of brick masonary valve pit chamber size 900 X900 X900 mm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-charge.
Material and labour for Construction of brick masonary valve pit chamber size 450 X450 X450 mm (internal dimension) using sub class 'B' bricks complete including excavation & earth work, returning fillig and disposal of surplus soil to distance not exceeding 50m and deposited where directed, PCC (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation, coping on top in PCC (1:2:4) type B-1 using 20 mm graded stone aggregate, brick work in cement mortar (1:4), inner plaster 12 mm thick in cm (1:3) finished even and smooth and pionting flush externally as the work proceeds in the same mortar, MS sheet cover 3.15mm thick mounted on angle iron frame of size 40 x 40 x 6mm with handle and locking arrangement duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and embeded portion of MS work duly applying black bitumenous paint before embeded complete all as specified and as directed by Engineer-in-charge.
Supply and connecting FRLSH single core flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 10 Sqmm 1100 Volt , draw through GI Pipe for connection to Motor terminal box from Starter Panel complete all as specified and as directed.
Supply and laying HDPE of size 50 mm bore, ISI marked, including fittings (elbow, tee, socket etc) laid in trenches,floor, under road, insert under holes for cable protection complete all as specified and as directed. (for laying PVC 10 sqmm cable from starter panel to motor terminal) (Note:- Excavation and earthwork as required shall be measured and paid separately under respective item of Sch.)
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mm thick RCC cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position
Suppyling, installing, testing and commissioning of factory made Outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15 mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc including double compression type cable gland with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
INCOMINGS
(a) 100 Amps copper bus bar for phases and Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
(b) MCCB 4P 63 Amps, 25 KA, thermal Magnetic release type - 01 No
OUTGOINGS
(a) MCCB 4P 25 Amps, 16 KA, thermal Magnetic release type - 02 No
(b) MCB SPN 32 Amps - 02 Nos
(c) Internal all links & control cable and indicators - set of three
(d) Single phase preventer type SDz5, SPPR + Timer, 415 V - 02 No
(e) fully automatic star delta starter type ML1 FASD having relay of range 09 - 14 Amp - 02 No
(f) Phase reversal relay and mechnaism -01 Nos
Material and labour for Boring of holes (trenchless) underneath the main road pavement, hardstanding or any other situation (horizontal) by means of manual manpower suitable for inserting pipe of 100 to 150 mm dia including removal of surplus soil and making good disturbed surface complete all as specified and as directed. NOTE:- Pipe for inserting as required shall be measured and paid for separately.
Dismantling of old unsv old unserviceable gate valve/globe valve of any size complete all as specified and directed.
Supply, installation , testing and commisioning of ABC type fire Extinguisher capacity 6 Kgs
Supply, installation , testing and commisioning of CO2 type fire Extinguisher capacity 4.5 Kgs
Supply, installation , testing and commisioning of Water stored pressure type fire Extinguisher capacity 9 Kgs
Supply, installation , testing and commisioning of Water stored pressure type fire Extinguisher capacity 9 Kgs
Supply fire bucket round botttom type enamel painted, white inside and red outside and letter "FIRE" in black out side and handle with mounting bracket
S&F copper cable 10 Sqmm x 4 Core Electric power cable for connections with Pump and Panel
Supply,Installation, Testing and commissioning central control panel with complete control of 8 Nos Repeater Panels and with communication facilities all as specified and directed by Engr-In-Charge.
Supply and fixing emergency Exit Sign Board with double side adhesive tape vinyl sticker with forex board (Green and White colour) 30 cm x 10 cm complete all as specified and directed.
Subtotal
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
PDFsam_merge.pdf
Tender Documents • 2.25 MB
BOQ_850352.xls
BOQ • 2.52 MB
Download all tender documents and submit your bid