Ex.Eng.(E.I.)Construction
Chief Engineer (Mechanical Electrical), Engineering Hub Building, Dr. E. Moses Road, Worli Naka, Worli, Mumbai- 400 018.
Design, fabrication, supply, installation, testing and commissioning of Energy Conservation system along with fire safety Equipments at BMC schools in City, Western and Eastern area (Group I, II , III).
2024_MCGM_1113855_2
Ch Eng MnE 4201 dtd.11.10.2024
Open Tender
Electrical Works
365 days
various mun properties
please refer tender documents
3 documents required · 3 mandatory
₹32,450
₹20.2 L
5 Dec 2024
7 Nov 2024
13 Nov 2024
7 Nov 2024
12 Nov 2024
7 Nov 2024
Amount
G-I Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-I SITC of Module mounting structure for modules roof mounted
G-I SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-I Refixing of solar panel
G-I Removing and transporting to bmc Warehouse
G-I Liasioning work for meter
G-I SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-I SITC of Clean agent fire extinguisher
G-I SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-I SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-I SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-I SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-I SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-I Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-I S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-I SITC of Earthing Continuity Conductors -25 x 6mm GI
G-I SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-I SITC of Auto glow signage in case of Fire etc.
G-I CSMC for 3rd Year
G-I CSMC for 4th Year
G-I CSMC for 5th Year
G-II Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-II SITC of Module mounting structure for modules roof mounted
G-II SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-II Refixing of solar panel
G-II Removing and transporting to bmc Warehouse
G-II Liasioning work for meter
G-II SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-II SITC of Clean agent fire extinguisher
G-II SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-II SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-II SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-II SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-II SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-II Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-II S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-II SITC of Earthing Continuity Conductors -25 x 6mm GI
G-II SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-II SITC of Auto glow signage in case of Fire etc.
G-II CSMC for 3rd Year
G-II CSMC for 4th Year
G-II CSMC for 5th Year
G-III Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-III SITC of Module mounting structure for modules roof mounted
G-III SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-III Refixing of solar panel
G-III Removing and transporting to bmc Warehouse
G-III Liasioning work for meter
G-III SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-III SITC of Clean agent fire extinguisher
G-III SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-III SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-III SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-III SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-III SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-III Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-III S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-III SITC of Earthing Continuity Conductors -25 x 6mm GI
G-III SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-III SITC of Auto glow signage in case of Fire etc.
G-III CSMC for 3rd Year
G-III CSMC for 4th Year
G-III CSMC for 5th Year
CHAITRA ELECTRICALS AND ENGINEERING (BID ID -6347180)
Sai Electricals and Engineers (BID ID -6346629)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid