Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 305 RATAN GALAXE J N ROAD MULUND W MUMBAI 400080 | MUMBAI | MUMBAI | MAHARASHTRA | 400080 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹20.2 L
Closing Date
12 Nov 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex.Eng.(E.I.)Construction
Chief Engineer (Mechanical Electrical), Engineering Hub Building, Dr. E. Moses Road, Worli Naka, Worli, Mumbai- 400 018.
Design, fabrication, supply, installation, testing and commissioning of Energy Conservation system along with fire safety Equipments at BMC schools in City, Western and Eastern area (Group I, II , III).
2024_MCGM_1113855_2
Ch Eng MnE 4201 dtd.11.10.2024
Open Tender
Electrical Works
Item Rate
365 days
various mun properties
please refer tender documents
3 documents required · 3 mandatory
₹32,450
₹20.2 L
8 Jul 2026
7 Nov 2024
13 Nov 2024
7 Nov 2024
12 Nov 2024
7 Nov 2024
Amount
G-I Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-I SITC of Module mounting structure for modules roof mounted
G-I SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-I Refixing of solar panel
G-I Removing and transporting to bmc Warehouse
G-I Liasioning work for meter
G-I SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-I SITC of Clean agent fire extinguisher
G-I SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-I SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-I SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-I SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-I SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-I Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-I S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-I SITC of Earthing Continuity Conductors -25 x 6mm GI
G-I SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-I SITC of Auto glow signage in case of Fire etc.
G-I CSMC for 3rd Year
G-I CSMC for 4th Year
G-I CSMC for 5th Year
G-II Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-II SITC of Module mounting structure for modules roof mounted
G-II SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-II Refixing of solar panel
G-II Removing and transporting to bmc Warehouse
G-II Liasioning work for meter
G-II SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-II SITC of Clean agent fire extinguisher
G-II SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-II SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-II SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-II SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-II SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-II Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-II S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-II SITC of Earthing Continuity Conductors -25 x 6mm GI
G-II SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-II SITC of Auto glow signage in case of Fire etc.
G-II CSMC for 3rd Year
G-II CSMC for 4th Year
G-II CSMC for 5th Year
G-III Supply, Delivery, Installation and Commissioning of 550Wp 144Cells Framed Dual Glass Mono PERC Bifacial Solar Module Highest Reliability & Enhanced Crack tolerant Module Utilizing Half Cut cell for Optimum Performance Highest commercial gains, lower LCOE *Standard Test Conditions (STC) - 1000 W/m2 irradiance, Air Mass 1.5 and 25°C cell temperature. Nominal Operating Cell Temperature (NOCT) - 800 W/m2 irradiance, Air Mass 1.5, Ambient temperature 20°C and Wind speed 1 m/s.Average power reduction of 4.5% at 200 W/m2 as per IEC 60904-1. Measuring Uncertainty ± 3%. Connector IP68 rated / MC4 compatible Solar Inverter IP65 AC&DC Distribution Board
G-III SITC of Module mounting structure for modules roof mounted
G-III SITC of 4Sqmm X 1 Core Black/Red ATC Cond. LSOH Insulated & Sheathed (120 Deg.C) UV Resistant Solar Cable e -Type 1
G-III Refixing of solar panel
G-III Removing and transporting to bmc Warehouse
G-III Liasioning work for meter
G-III SITC of LED type 40W Solar light fixtures withSENSOR PIR & INTELLIGENT inbuilt battery.
G-III SITC of Clean agent fire extinguisher
G-III SITC of PVC Trunking with cover & all other accessories – 100 x 50mm (W x H) - PVC Trunking with cover and partition
G-III SITC of 1 st category Al armoured cables FRLS outer sheathed- 3.5C x 70 Sq.mm
G-III SITC of Cable End Termination For Copper Cables – 2C x 4 Sq.mm
G-III SITC of Cable End Termination For Aluminium Cables – 3.5C x 70 Sq.mm
G-III SITC of G.I. Cable tray with all other accessories 100 x 25mm (W x H) - (16 SWG - 1.6mm) without cover
G-III Supply & Laying of double wall corrugated ( DWC) pipe 50 mm OD / 38 mm I.D.
G-III S.I.T.C of maintenance free earthing comprising 17.2 mm electrode
G-III SITC of Earthing Continuity Conductors -25 x 6mm GI
G-III SITC of Class B+C/Type I+II Surge Protection Devices For Switching Surge & Lightning Surge, For Handling 10/350 & 8/20 Microsecond Waveform For : Three Phase & neutral Application MODEL : V25-B+C/3+NPE-320V
G-III SITC of Auto glow signage in case of Fire etc.
G-III CSMC for 3rd Year
G-III CSMC for 4th Year
G-III CSMC for 5th Year
CHAITRA ELECTRICALS AND ENGINEERING (BID ID -6347180)
Sai Electricals and Engineers (BID ID -6346629)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 1.64 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .