Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.2 CrAccepted-AOC | ₹11.2 Cr | 1 | Accepted-AOC M/S Cimcon Software India Pvt Ltd is lowest evaluated Bidder |
| 2 | 2₹12.7 CrRejected-Finance | ₹12.7 Cr | 2 | Rejected-Finance Rejected |
| 3 | 3₹13.3 CrRejected-Finance MECHATRONICS HOUSE S NO 107 WARJE MUMBAI BANGLORE BY PASS HIGHWAY PUNE 411 058 | PUNE | MAHARASHTRA | 411058 | ₹13.3 Cr | 3 | Rejected-Finance Rejected |
| 4 | Rejected-Technical E 261 AMAR COLONY LAJPAT NAGAR IV LAJPAT NAGAR IV SOUTH DELHI DELHI 110024 UDYAM DL 08 0001872 09AAACB0262A1ZF B S 07AAACB0262A1ZJ R 09AAACB0262A1ZF M | SOUTH EAST DELHI | DELHI | 110024 | - | - | Rejected-Technical Disqualified as per Ters and Conditions of DNIT |
| 5 | Rejected-Technical | - | - | Rejected-Technical Disqualified as per Ters and Conditions of DNIT |
Tender Value
Refer Docs
EMD Value
₹26 L
Closing Date
15 May 2020, 12:00 pmClosed
executive engineer
Executive Engineer NHP Irrigation Deptt. sector 5 3rd floor NHP Data
Supply Installation operation and Maintenance of SCADA system for JLN Canal Pumping Automation For IWRD Haryana under National Hydrology Project NHP
2020_HRY_124222_2
JLN_SCADA
Open Tender
Electronics Equipment
365 days
Panchkula
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
Executive engineer
₹26 L
Yes
panchkula
5 Aug 2020
17 Mar 2020
15 May 2020
17 Mar 2020
15 May 2020
17 Mar 2020
30 Mar 2020
Amount
Supply of Local control PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet for pump, fitted with Power buses, MCBs & GPRS/GSM modem, external antenna. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up, 7” or above HMI display & suitable switch mode power supply (SMPS) & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments. Each PLC/RTU system shall be compatible for integration of instrumentation system for 5 No. of VT pumps, as per technical specification.
Supply of Water Level transmitter non-contact Ultrasonic type for measuring sump level/ open channel flow. Including all necessary cabling with suitable conduits & electrical fittings & integration with PLC/RTU complete as per technical specifications.
Supply of Side looking Acoustic Doppler based Velocity Meter (ADVM) for direct discharge measurement in main Canal systems with bed width of 0-20m, including cabling, installation accessories & integration with PLC/RTU as per technical specifications.
Supply, installation, testing & Commissioning of Energy meters for tube wells & pumping stations including all accessories, cabling and integration with Automation system as per technical specifications.
Supply of vibration monitoring sensor along with cabling & interconnection with PLC/RTU as per technical specification.
Supply of Temperature Monitoring sensors along with cabling & integration with temperature Scanners as per technical specifications.
Supply of 12 channel temperature Scanners for monitoring and transmitter the same to PLC/RTU as per technical specifications.
Supplyof Pressure Transmitters, making proper socket in pipe & two-way gauge cock in SS 316 for isolation of PT for installation of pressure transmitter including cabling and conduiting wiring etc. complete as per as per technical specifications.
Supply of industrial grade computer Node (Workstation) with 42” LED Display, 3G/4G internet dongle/broadband, installed with client SCADA software, including 1 KVA UPS for Power back up and A4 size color printer, at each pumping station for monitoring and controlling of the respective pumping station with necessary accessories as per technical specifications.
Supply of VSAT system for communication between Master and Local SCADA control station for pumping automation system with necessary accessories as per technical specifications.
Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings of Industrial type. Including suitable switch mode power supply (SMPS), 12” display for GSM/GPRS based communication with Local PLC/RTU’s of respective pumping stations, complete as per technical specification.
Supplyof customized SCADA-DSS (Decision support system) software for complete Pumping automation System of JLN canal with life time licensed version as per technical specifications.
Supply of Master server which includes Server with server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications.
Supply of IT Hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 Color printer as per technical specifications.
Supply of 110” LED Display/ Video wall/ (70”, 2X1) DLP based System for monitoring of SCADA system at Master Control Room as per technical specifications
Supply of online 3 KVA UPS with Battery system for power back up of Master Control Room equipment’s including all necessary cabling & electrical fittings complete as per the technical specifications
Supply of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing along with accessories completeat master control room, as per technical specifications.
Supply of Air conditioning system with requisite furniture, Renovation & Furnishing of existing Master Control Room for establishment of SCADA Control room long with necessary electrical fittings as per technical specification.
Laying and Jointing PVC Pipe. Heading
Installation, testing & Commissioning of Local control PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet for pump, fitted with Power buses, MCBs & GPRS/GSM modem, external antenna. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up, 7” or above HMI display & suitable switch mode power supply (SMPS) & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments. Each PLC/RTU system shall be compatible for integration of instrumentation system for 5 No. of VT pumps, as per technical specification.
Installation, testing & Commissioning of Water Level transmitter non-contact Ultrasonic type for measuring sump level/ open channel flow. Including all necessary cabling with suitable conduits & electrical fittings & integration with PLC/RTU complete as per technical specifications.
Installation, testing & Commissioning of Side looking Acoustic Doppler based Velocity Meter (ADVM) for direct discharge measurement in main Canal systems with bed width of 0-20m, including retractable mounting frame, cabling, installation accessories & integration with PLC/RTU& associated civil work, as per technical specifications.
installation, testing & Commissioning of Energy meters for tube wells & pumping stations including all accessories, cabling and integration with Automation system as per technical specifications.
installation, testing & Commissioning of vibration monitoring sensor along with cabling & interconnection with PLC/RTU as per technical specification.
installation, testing & Commissioning of Temperature Monitoring sensors along with cabling & integration with temperature Scanners as per technical specifications.
installation, testing & Commissioning of 12 channel temperature Scanners for monitoring and transmitter the same to PLC/RTU as per technical specifications.
Pressure Transmitters, making proper socket in pipe & two-way gauge cock in SS 316 for isolation of PT for installation of pressure transmitter including cabling and conduiting wiring etc. complete as per as per technical specifications.
installation, testing & Commissioning of industrial grade computer Node (Workstation) with 42” LED display, 3G/4G internet dongle/broadband, installed with client SCADA software, including 1 KVA UPS for Power back up and A4 size color printer, at each pumping station for monitoring and controlling of the respective pumping station with necessary accessories as per technical specifications.
installation, testing & Commissioning of VSAT system for communication between Local and Master SCADA control stations for pumping automation system with necessary accessories as per technical specifications.
Installation, Testing & Commissioning of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Including suitable switch mode power supply (SMPS), 12” display for GSM/GPRS based communication with Local PLC/RTU’s of respective pumping stations, complete as per technical specification.
Engineering, development & testing of customized SCADA-DSS (Decision support system) software for complete Pumping automation System of JLN canal with life time licensed version as per technical specifications.
Installation, Testing & Commissioning of Master server with SCADA Software which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, and Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications.
Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router with modem, Switch, firewall system and A3 colour printer as per technical specifications
Installation, Testing & Commissioning 110” LED Display/ Video wall/ (70”, 2X1) DLP based System for monitoring of SCADA system at Master Control Room as per technical specifications
Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of Master Control Room equipment’s as per the technical specifications
Installation, Testing and Commissioning of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects as per technical specifications.
Charges for high speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Five years.
Charges for High speed 4G/3G internet connection for local control room for monitoring & controlling of respective pumping stations for Five years.
Charges for VSAT communication between pumping stations & SCADA system for monitoring& controlling JLN canal system for Five years.
Installation of Air conditioning system with necessary electrical fittings at existing Master Control Room for establishment of SCADA Control room long as per technical specification.
Five Years Operation & Maintenance and Comprehensive Warranty for SCADA based pump automation system for JLN canal network as per Price schedule after final acceptance of SCADA system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS & SIM charges for data transmission, maintenance and other related charges for each local control station & Master Control station. Minimum Two Service Engineer shall be placed at Master Control Room for Operation of SCADA based Pumping automation.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU & SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.
CORONET ENGINEERS PVT LTD
Mechatronics Systems Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid