Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAdmitted-Finance | ₹2.8 L | L1 | Admitted-Finance |
| 2 | L2₹3.0 L+₹21,948 (7.95%)Admitted-Finance B 225 FATEH NAGAR WEST DELHI WEST DELHI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹3.0 L+₹21,948 (7.95%) | L2 | Admitted-Finance |
| 3 | L3₹3.2 L+₹42,480 (15.4%)Admitted-Finance | ₹3.2 L+₹42,480 (15.4%) | L3 | Admitted-Finance |
| 4 | L4₹3.8 L+₹1.0 L (37.2%)Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | ₹3.8 L+₹1.0 L (37.2%) | L4 | Admitted-Finance |
| 5 | L5₹4.8 L+₹2.0 L (72.1%)Admitted-Finance 14 C POCKET A VIKAS PURI EXTN NEW DELHI 110018 | WEST | DELHI | 110018 | ₹4.8 L+₹2.0 L (72.1%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s Nagpal Associates L5 | Premier Engineering Company L4 | M/S.SUPER TRADERS & ENGINEERS L2 | HYDROCON ENGINEERS L3 | Gupta Brothers L1 |
|---|---|---|---|---|---|---|---|---|
| 1.01 | Supply of Automatic LT Panel Board suitable for 415 Volts, 3 Phase, 50 HZ, 4 wire system for operation of up to 15 HP submersible set, made out of not less than 2 mm thick CRCAfor load bearing members and 1.6 mm for doors of panel, Totally enclosed, dust and vermin proof, floor mounted type. The panel size 760 mmX 1360 mm X300 mm and having (1) 63 amp change over- 1 No (2) 63 A TPN MCCB -1 No (3) Amp meter 0-50 A- 1 No (4) Voltmeter 1 No (5) Amp & volt meter selector switches-1 set (6) Auto-manual + Light + control MCB TP 32 Amp- 1Nos each (7) CT -3Nos (8) Push button + ON/OFF light 2 Nos each (9) 5 KVAR Shunt capacitor- 1 No (10) Aluminium Bus bar size 25 mm X 6 mm - 1set (11) 15 HP Star Delta starter (a) 32 Amp Power contactor-3 Nos (b) overload relay 14-23 A -1 No (C) Star delta timer- 1 NO0 (d) QT Timer -24 Hours -1 No (e) Motor Protection relay 200, Short circuit, earth fault, Phase loss, unbalance, phase reversal, locked rotor protection Make:- Sub- tech/HPL/ Protex./ make of accessories/component as per DJB approved. | 6 | Nos | 3,93,000 ₹4,63,740 | 2,91,000 ₹3,43,380 | 2,40,000 ₹2,83,200 | 2,43,000 ₹2,86,740 | 2,16,000 ₹2,54,880 Lowest |
| 1.02 | Breaking and making of foundation, the job includes all tool tackles, loading and unloading, safety equipment and other precautions etc. i/c testing and commissioning of load and unload to complete satisfactory of engineer in charge | 6 | Nos | 9,600 ₹11,328 Lowest | 30,000 ₹35,400 | 12,600 ₹14,868 | 27,000 ₹31,860 | 18,000 ₹21,240 |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
13 Jul 2026, 3:00 pmClosed
EE(E AND M) M-6
EE(E AND M) M-6
Replacement of panels at Tw Kali Mandir Sarai Phoos, Tw Hamilton Road, Tw Patubi House, Tw Dhobi Ghat, Tw Peeli Kothi and Tw Butler Compound tube wells under Chandni Chowk Constituency AC-20.
2026_DJB_294908_14
NIT NO-08 (2026-2027)
Open Tender
Miscellaneous Works
Item Wise
30 days
EE(E AND M) M-6
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
THROUGH DJB OFFICIAL WEBSITE IN LINK TENDER
₹9,400
Yes
17 Jul 2026
6 Jul 2026
13 Jul 2026
6 Jul 2026
13 Jul 2026
6 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supply of Automatic LT Panel Board suitable for 415 Volts, 3 Phase, 50 HZ, 4 wire system for operation of up to 15 HP submersible set, made out of not less than 2 mm thick CRCAfor load bearing members and 1.6 mm for doors of panel, Totally enclosed, dust and vermin proof, floor mounted type. The panel size 760 mmX 1360 mm X300 mm and having (1) 63 amp change over- 1 No (2) 63 A TPN MCCB -1 No (3) Amp meter 0-50 A- 1 No (4) Voltmeter 1 No (5) Amp & volt meter selector switches-1 set (6) Auto-manual + Light + control MCB TP 32 Amp- 1Nos each (7) CT -3Nos (8) Push button + ON/OFF light 2 Nos each (9) 5 KVAR Shunt capacitor- 1 No (10) Aluminium Bus bar size 25 mm X 6 mm - 1set (11) 15 HP Star Delta starter (a) 32 Amp Power contactor-3 Nos (b) overload relay 14-23 A -1 No (C) Star delta timer- 1 NO0 (d) QT Timer -24 Hours -1 No (e) Motor Protection relay 200, Short circuit, earth fault, Phase loss, unbalance, phase reversal, locked rotor protection Make:- Sub- tech/HPL/ Protex./ make of accessories/component as per DJB approved. | 6 | Nos | 100 | ₹600 |
| 1.02 | Breaking and making of foundation, the job includes all tool tackles, loading and unloading, safety equipment and other precautions etc. i/c testing and commissioning of load and unload to complete satisfactory of engineer in charge | 6 | Nos | 100 | ₹600 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.73 MB
BOQ_392347.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .