Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance BLOCK A PROPERTY NO 104 BRAN APARTMENT GANGA NAGAR BULANDSHAHR | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹41.5 L
EMD Value
₹41,500
Closing Date
6 Dec 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE EDC-I BSR
SE EDC-I HYDEL COLONY BULANDSHAHR
Business Plan 24-25 (Part-2) Under the scheme, work related to increasing the capacity of distribution transformers and setting up additional transformers.
2024_PVVNL_973671_1
T-59/EDC-I/B/2024-25
Open Tender
Electrical Works
Item Rate
30 days
BULANDSHAHR
PLZ REFER TENDER DOCUMENT
2 documents required · 2 mandatory
₹3,540
SE EDC-I
₹41,500
9 Dec 2024
14 Nov 2024
6 Dec 2024
14 Nov 2024
6 Dec 2024
14 Nov 2024
Amount
fctusl Iyku 24&25 ¼ikVZ&2½ ;kstuk ds vUrxZr fo|qr forj.k [k.M&[kqtkZ ds dk;Z{ks= esa 33@11 dsoh fo|qr midsUnzksa ds vUrxZr forj.k ifjroZdksa dh {kerko`f) ,oa vfrfjDr ifjroZd LFkkfir djus lacaf/kr dk;ZA
Safe carriage of store mattrial from store center to site store with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 50 Kms.
PCC Poles 8.5 mtr. long
ST Poles 11 mtr. long
1*16/1*120/1*240 LT T/F Lead any size
3x70 Sq.mm. XLPE Cable 11 KV
3x120+1x95+1x16 Sq mm AB Cable
3x95+1x50+1x16 Sq mm AB Cable
3x50+1x35+1x16 Sq mm AB Cable
ACSR Dog Conductor
ACSR Weasel Conductor
T/F 25/63/100 KVA 11/0.4 KV
T/F 250 KVA 11/0.4 KV
11 KV DO Fuse Set complet
11 KV Fuse Set complet
Earthing Rod all type
Distribution Box.
Loading, Safe carriage & unloading of heavy stock material V Type, Disc Insulator, Pin Insulator, Cable jointing kit ID/OD channel, Angle and other site requerment any mattrial ETC from store center to site store with proper stacking of material, distance within-70Kms.
Erection of Single pole ST Pole 11 mtr long of 33 KV fittings as per RESPO Drawing Top Channal, Dropper Channal, X Bracing Set, Disc Insulator, Pin Insulator, Guarding Angle F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Erection of Dobule pole ST Pole 11 mtr long of 33 KV fittings as per RESPO Drawing Top Channal, Dropper Channal, X Bracing Set, Disc Insulator, Pin Insulator, Guarding Angle F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.
Grouting of Single Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement
Grouting of Dobule Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement
Provading & Fixing of Planth of pole/Kiking of pole up nuturel Ground level.
Fixing of 11 Kv Stay Set
Grouting of 11 Kv stay set including the work of nozelling etc. as per RESPO manual and also including the cost of all The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone etc. as per actual site requirement , labour, T&P etc required for proper completion of work.
Laying sagging stringing and binding and jumpering in air area etc of following ACSR Conductor/ wisel/Rabit/ABC all size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work.
1*16/1*120/1*240 LT T/F Lead any size
3x70 Sq.mm. XLPE Cable 11 KV
3x120+1x95+1x16 Sq mm AB Cable
3x95+1x50+1x16 Sq mm AB Cable
3x50+1x35+1x16 Sq mm AB Cable
ACSR Dog Conductor
ACSR Weasel Conductor
Fixing of 11 Kv Cable jointing kit ID/OD
Fixing of T/F 25/63/100 KVA 11/0.4 KV
Fixing of T/F 250 KVA 11/0.4 KV
Making Jumpers on Section Points, by fixing of proper sizes, suitable for ACSR Conductor. Sectional Double/Four Pole.
Providing OF Danger Plate.
Fixing of Danger Plate.
Providing & Fixing of Chemicle earthing Electrod rod.
Fixing of T Off channel.
Providing & Fixing Stone Pad
Providing & Fixing barbard wire
Fixing of Top/Drop channel
Fixing of MS Angle 65x65x6
Fixing of 11 KV V CROSS-ARM
Provading of Nut-Bolts off size
Fixing of Nut-Bolts off size
Provading of Nut-Bolts off size for distubation box and No. plate/danger plate
Fixing of Nut-Bolts off size for distubation box and No. plate/danger plate
THE WORK OF MAKING 0F T/F PLANTH FOR T/F WITH MATRIAL
THE WORK OF MAKING 0F T/F FANCING MS Angle & Jalie FOR T/F WITH MATRIAL
Fixing of DISTRIBUTION BOX 3 PHASE
Provading of Lock for distribution box
Fixing of Lock for distribution box
Provading of J-Hook
Fixing of J-Hook
Providing & Fixing Dead End Clamp/Suspension Clamp
Provading & Fixing all tipe Cross arm Clamps.
Provading & Fixing F Clamps.
Provading & Fixing PRC
Fixing of 11 KV DO Fuse Set
Provading & Fixing of Stay insulator
TF Saffty Wall
Disconnecting the connection before starting the work and reconnecting it to the distribution box after completion of the work per unit.
Fixing of 11 KV pin Insulator
Fixing of 11 KV Disc Insulator
Proveding & Fixing Tellness unit of different size with structure.
M/S SURYA ELECTRICALS (BID ID -4763829)
M/S SHRI KRISHNA CONTRACTORAS (BID ID -4765880)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .