Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.7 LAccepted-AOC NEAR SATSANG GARACHARMA BASTI GARACHARMA PORT BLAIR 744 105 | PORT BLAIR | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744105 | L1 | Accepted-AOC L1 | |
| 2 | L2₹57.9 L+₹8.1 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹58.2 L+₹8.4 L (16.8%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical OPP CCS GARACHARMA PORT BLAIR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | - | Rejected-Technical Residual work load and site visit certificate not found enclosed | |
| 5 | Rejected-Technical | - | Rejected-Technical Residual work load and site visit certificate not found enclosed |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
23 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
ADDITION AND ALTERATION TO BLDG NO P-237 OF INS UTKROSH AND PROVN OF TWO NOS AC FOR CRSO OFFICE AT ISH HQ MINNIE BAY UNDER GE MINNIE BAY PORT BLAIR
2023_MES_630726_1
8332/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
11 documents required · 11 mandatory
₹500
GE Minniebay
₹95,000
Yes
30 Jan 2024
1 Dec 2023
26 Dec 2023
2 Dec 2023
23 Dec 2023
16 Dec 2023
Amount
S&F Mild Steel Rolled sections as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed by Engineer in Charge.
Material and labour for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer in Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as manufacturers instruction complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutter, drip, and straight flashing, roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S & F Aluminium flat , wind ties of any size fixed with self tapping screws of size 40/50mm with integral EPDM washer screwed in roof covering, including all necessary drilling, bolting or riveting etc., and similar work complete all as specified and directed by Engineer in Charge.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and directed by Engineer in Charge.
S&F for aluminium anodised snap grid false ceiling of standard aluminium section such as wall angle of size 38mm x 25mm x 2.4mm weighing 0.36 Kg/Rm main/cross tees of size 36.5mm x 25mm x 1.4mm weighing 0.24 Kg/Rm, grid size n.exc. 610 x 610mm suspended with 4mm dia GI wire at interval n.exc. 600mm centre to centre for main & cross tees fixed to roof slab roof truss fixed with suitable size MS hook and fastening bolts etc including 'E' board classic 4mm thick oceanic sheet of size n.exc. 610 x 610mm size fixed in ceiling with clips to aluminium snap grid complete all as specified and directed by Engineer in Charge.
Supply and fixing 5mm thick PVC sheet of (wooden pattern as required) as in strips & channels feathered at edges for fixing to wall and ceiling lining inclusive of solvent cement and fixing at site etc complete all as specified and as directed by Engineer-in- charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and drawing complete all as specified and directed by Engineer in Charge.
S&F GI frame work 605 X 605mm grid for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate chennel 0.9mm thick having two equal flanges of 15mm each and web 45mm suspended from soffit at approx 900mm centre to centre with GI cleats and steel expansion fastener with and including ceiling section (not exc. 1.2m length) of 0.5mm thickness having kurled web of 50mm flange of 26 mm each with lips of 1050 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including 605 X 605mm grid hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long complete all as specified and directed by Engineer in Charge.
S&F 12mm thick Toughned glass fixed as in partition/cladding/shutter portion and similar work with stainless steel fittings such as hydraulic floor spring, 300mm SS handle, SS hinges, cleats etc complete all as specified and directed by Engineer in Charge.
Supply and fix of wall racks size 8 feet height x 3feet wide with 07 shelves making 07 compartments with bottom shelf of 18inch, second of 15inch and remaining shelf 12inch depth all shelf 20swg thick, pillars 14swg thickness, clamp 12swg thick, back sheet 22swg thick and front patti MS Data strip of 20swg thickness powder coated all as specified and as directed by Engineer in Charge.
Supply and fix of centre rack racks (colour& pattern shall be approved by Engineer-in-Charge) size 6 feet height x 3 feet wide with 5+5 shelves making 10 compartments with bottom shelf of 18inch, second of 15inch and remaining shelf 12inch depth all shelf 20swg thick, pillars 14swg thickness, clamp 12swg thick, back sheet 22swg thick and front patti MS Data strip of 20swg thickness powder coated all as specified and as directed by Engineer in Charge.
Supply and fix of end cap racks (colour& pattern shall be approved by Engineer-in-Charge) size 6 feet height x 3feet wide with 5 shelves making 05 compartments with bottom shelf of 18inch, second of 15inch and remaining shelf 12inch depth all shelf 20swg thick, pillars 14swg thickness, clamp 12swg thick, back sheet 22swg thick and front patti MS Data strip of 20swg thickness powder coated all as specified and as directed by Engineer in Charge.
Demolition of Precast Concrete work/ precast concreteblock built in cement mortar including all quoins arches pillars etc complete all as specified and directed by Engineer in Charge.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key complete all as specified and directed by Engineer in Charge.
M & L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound (3% of total weight of cement or as per manufacturer's instructions) and finishing the top surface even and fair complete all as specified and as directed by Engineer-in-Charge. Note: The cost of the water proofing compound shall deemed to included in this quoted rate.
M&L for rendering 10mm thick plaster in CM (1:6) on brick/block or concrete surfaces finished even & smooth complete all as specified and directed by Engineer in Charge.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed by Engineer in Charge. Make : Asian Paints ( Apex Ultima)
M & L for two coats of oil bound distemper over a coat of chalk whiting, on plastered surfaces, prepaeatory to distempering complete all as specified and directed by Engineer in Charge.
M&L for applying One coat of acrylic emulsion weather coat premium quality antifungal exterior emulsion on old plastered surface of wall including preparation complete all as specified and directed by Engineer in Charge. Make : Asian Paints ( Apex Ultima)
M & L for complete removal of existing treatment on wall surfaces and applying two coats of oil bound distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed by Engineer in Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer in Charge.
M&L for vitrified double charged dark shades tiles 10mm thick premium quality (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc set and jointed in ement slurry and pointed in coloured cement to match over a screed bed of 15mm thick in CM 1:6 complete all as specified and directed by Engineer in Charge.
Material and labour for cleaning the wall surfaces from dirt, stain, oil etc and laying/installing PVC/Vinyl/High definition star wall paper of any colour, pattern/ theme (latex/ non woven material) premium type, easy to clean, without bubbles using rollers, sponges etc complete all as specified and directed by Engineer in Charge.
M&L 0.9mm thickness decorative laminate,of surface finish,colour and pattern as approved, fixed with approved adhesive as per manufactures instructions complete all as specified and directed by Engineer in Charge.
M&L for taking down carefully existing point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, Ceiling roses, pendents, regulators, sockets etc unscrewing from board/outlet boxes, removing metal flush boxes, cover plate with frame, PVC conduits, lamp holder, tubelight/ceiling fitting, bulk head fittings etc removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls/floors to match with the existing surfaces and wall colour etc complete all as specified and as directed by Engineer-in-Charge. Note : (i) Electrical fixture/ fittings & cables shall be kept at contractor custody and if any theft/ damage shall fully attributable to contractor. (ii) Contractor shall make necessary site visit for assessing the condition of wires/cables, fixtures for the feasibility of reuse and shall quote accordingly.
M&L for taking down submain wiring of any size alongwith PVC conduits etc removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls/ floors to match with the existing surfaces and wall colour etc complete all as specified and as directed by Engineer-in-Charge. Note : (i) Electrical fixture/ fittings & cables shall be kept at contractor custody and if any theft/ damage shall fully attributable to contractor. (ii) Contractor shall make necessary site visit for assessing the condition of wires/cables, fixtures for the feasibility of reuse and shall quote accordingly.
M&L for taking down distribution boxes by removing of all electrical connection including MCCB/MCBs etc removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls/ floors to match with the existing surfaces and wall colour complete all as specified and as directed by Engineer-in-Charge. Note : (i) MCCB/MCBs shall be kept at contractor custody and if any theft/ damage shall fully attributable to contractor. (ii) Contractor shall make necessary site visit for assessing the condition of wires/cables, fixtures for the feasibility of reuse and shall quote accordingly.
M&L for taking down fan, sealing cable end, dismantling blades and removing fan and blades to store for keeping in safe custody for reuse at site complete all as specified and as directed by Engineer-in-Charge.
M&L for relaying of point wiring (light, fan, socket or power) retrieved from item No.27 complete with three run of single core PVC insulated unsheathed 1100 volts grade multistranded copper conductor of any size drawn through & including rigid non metallic PVC conduit including fitting of fixture such as switches, Ceiling roses, pendents, regulators, sockets etc screwing to Board/outlet boxes, concealed the metal flush boxes in wall, cover plate with frame and making good disturbed surfaces of walls, floors etc to match with the existing surfaces and wall colour complete all as specified and as directed by Engineer-in-Charge.
Fixing only existing ceiling light fitting 2' x 2' on PVC ceiling board including cutting of ceiling board suitable for light fitting and all fitting accessories complete all as specified and as directed by Engineer-in-Charge. Note : The cost for three core flexible cable shall be deemed to be included in the quoted rate
M&L for relaying of submain wiring of any size retrieved from item No 28 alongwith PVC conduits etc including GI saddles & screws complete all as specified and as directed by Engineer-in-Charge.
Fixing only VTPN MCCB DB concealed in wall of any size retrieved from item No 29 and connecting all existing electric cables including fitting the MCCB/MCBs with appropriate size of copper lugs etc and making good disturbed surfaces of walls/ floors to match with the existing surfaces and wall colour complete all as specified and as directed by Engineer-in-Charge. [Note : The cost for flushing of Distribution box in any type of wall and making good disturbed surfaces with existing colour shall be deemed to be included in the quoted rate]
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and as directed by Engineer-in-Charge.
M&L for submain wiring with PVC insulated unsheathed multi-stranded FRSLH copper conductor cable four run of 16 Sqmm single core, 1100 volts grade drawn through in and including non metallic rigid PVC conduit, medium grade not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles, GI screws, rawl plugs with all fittings and two runs of 16 Sqmm PVC insulated copper conductor for earth continuity wire complete all as specified and as directed by Engineer-in-Charge. Note : (i) Six runs of cable and one run of PVC conduit will be measured as one unit.(ii) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit and making good disturbed surfaces with existing wall colour complete
All as per item No 36 here-in-before but with 10 sqmm cable complete all as specified and as directed by Engineer-in-Charge.
M&L for submain wiring with PVC insulated unsheathed multi-stranded FRSLH copper conductor cable two runs of 1.5 Sqmm single core, 1100 volts grade drawn through in and including non metallic rigid PVC conduit, medium grade not less than 20 mm dia concealed in wall/fixed on wall/ceiling with GI saddles, GI screws, rawl plugs with all fittings and one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire complete all as specified and as directed by Engineer-in-Charge. Note : (i) three runs of cable and one run of PVC conduit will be measured as one unit.(ii) Rates are deemed to be included for chases of conduit, cutting and making holes in wall/floor for passing in or through conduit and making good disturbed surfaces with existing wall colour complete
All as per item No 38 here-in-before but with 2.5 sqmm cable complete all as specified and as directed by Engineer-in-Charge.
All as per item No 38 here-in-before but with 6.0 sqmm cable complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing IP 65/66 thermoplastic Polycarbonate cable junction box of size 155 x 210 x 92 mm with terminals which is totally shock proof, water proof, halogen free, silica and having thermally embedded gasket technology fixing on pole/surface/frame/wall with the help of GI clamp of required size/self drill screw complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm 40 watt, 100 lm/watt, IP-20, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
Supply and install hi wall split Air Conditioner units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 5 star rating of capacity 2.0 TR complete all as specified and as directed by Engineer-in-Charge. Note : (i) The cost of copper tubing of any length from indoor to outdoor unit, remote with batteries, refrigerant gas, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces shall deemed to be included in the quoted rate.(b) Drilling of the block masonry shall be done through core cutting machine only and debris shall be cleared off from the MD land.
Supply and fix Power unit modules 25A, 240V, 50HZ consists of 2 module surface mounting plastic box - 2 No, 2 module cover plate & frame - 2 No, 25Amps Motor Starter - 1 No , 25Amps socket - 01 No and 25 Amps Plug Top - 1 No complete all as specified and as directed by Engineer-in-Charge.
Supply and fix Air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on wall complete all as specified and as directed by Engineer-in-Charge.
Material and labour for submain wiring with two single core PVC insulated unsheathed multistranded copper conductor cable of size 6 sqmm (FRLSH) and one single core PVC insulated unsheathed multistranded copper conductor cable green colour of size 6 Sqmm (FRLSH) as earth lead in and including concealed with PVC conduit medium grade of suitable size or surface wiring with PVC casing caping of suitable size and making good the disturbed wall surfaces to match with existing specification including takind down unserviceable submain wiring complete all as specified and as directed. Note : (i) Three runs of cable with one run of PVC conduit/PVC casing and caping shall be measured as one unit length. (ii) Wiring shall be concealed/ on surface mounted with rigid PVC conduit medium grade/PVC casing caping as per site requirement as directed by Engineer-in-Charge.
Supply and fixing Rigid non-metallic PVC conduit, heavy duty 25 mm dia inclusive of all fittings and fixing accessories complete all as specified and as directed by Engineer-in-Charge.
bansal construction
BISAKHA PLUMBING WORKS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .