| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.5 LAccepted-AOC 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹30.2 L+₹30,247 (1.01%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | 2 | Rejected-Finance Being other than lowest | |
| 3 | 3₹31.9 L+₹2.0 L (6.78%)Rejected-Finance | 3 | Rejected-Finance Being other than lowest | |
| 4 | 4₹32.8 L+₹2.9 L (9.70%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | 4 | Rejected-Finance Being other than lowest | |
| 5 | 5₹33.8 L+₹3.9 L (13.1%)Rejected-Finance 6 NALAPUKUR LANE FLAT 2C SENHATI COLONY KOLKATA 700034 WEST BENGAL | KOLKATA | WEST BENGAL | 700034 | 5 | Rejected-Finance Being other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
10 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Alipore
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
REPAIR/MAINT TO INTERNAL WIRING, SUB MAIN WIRING, FAN, GEYSER AND ALLIED WORKS AT CH (EC) UNDER GE ALIPORE KOLKATA
2024_MES_660543_1
GE/ALP (8332B) KOLKATA OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Alipre) Kolkata
Class D and Category b (i)
9 documents required · 9 mandatory
₹500
Garrison Engineer, Alipore
₹60,000
Yes
GE (Alipore) Kolkata
6 Sept 2024
19 Jun 2024
17 Jul 2024
19 Jun 2024
10 Jul 2024
3 Jul 2024
19 Jun 2024 - 26 Jun 2024
27 Jun 2024
Amount
Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc as specified and directed.
M& L for Point wiring with 1.5 Sqmm PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLSH type drawn through and including PVC casing caping/conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.2 mm thick, one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metalic bodies of luminaires/ fan at other end complete all as specified and directed for the following:-
One light point / one fan point controlled by one, way swtich.
All as per item No 2.0 here in before but for one 5 Amp 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No 2.0 here in before but on independent board.
All as per ser item No 2.0 herein before but with 2.5 Sqmm PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including boards for mounting purposes.
All as per ser item No 2.0 here in before but one light point controlled by 2 way switches.
All as per ser item No 2.0 here in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent.
Supply and fixing in replacement of switch piano flush button 5 Amp single pole one way 230 volts white finish all as specified & directed.
Supply and fixing in replacement of bell push, 230 volts white finish all as specified and directed
Supply and fixing in replacement of bell ding dong type AC, 230 volts, single phase complete all as specified and directed.
Supply and fixing in replacement of step type fan regulator complete all as specified and directed.
Supply and fixing in replacment of ceiling rose of size 65 x 50 mm surface bakelite 240 Volts three terminal as specified and directed.
Supply and fixing in replacement angle type Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply and fixing in replacement switch socket combination 2 in 1, 5 pin, 6 Amps flush type all as specified and as directed
Supply and fixing in replacement switch socket combination 3 pin , 16 Amp flush type, all as specified and as directed
Supply and fixing in replacement of switch piano flush button 5 Amp single pole 2 way 230 volts white finish all as specified & directed.
Supply & fix LED tube 20 W Tube light fitting LED Batten with aluminum housing and integrated electronic driver with square profile extruded connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as specified and directed.
Supply & fix LED 9/10 W Tube light fitting LED Batten extruded and polycarbonate connecting up with three core flexible copper conductor cable of suitable size from ceiling rose up to 1.5m length complete all as directed
Supply and fixing of LED 36/42 Watt recessed mounted fitting, energy efficient, decorative type suitable for armstrong/grid ceiling, with its super bright LED complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.
Supply and fix in repacemnt MCB DB double door with necessary lugs for incomming and outgong connections up to Copper/Aluminium conductor og 16 sq mm fixed on wall surface/concealed after taking down the existing DB of any make/ rating from any height for the following Way
MCB DB SPN 4 Way.
MCB DB SPN 8 Way .
MCB DB SPN 12 Way.
MCB DB TPN 4 way.
Supply and fix in replacement MCB of following rating
MCB SP 6 to 40 Amp
MCB DP/SPN 6 to 40 Amp
MCB TP 6 to 40 Amp
MCB TPN 40 to 63 Amp
S&F VTPN prewired distribution board TPN-DPX 160 MCCB including one No MCCB 160 Amps as incomer and suitable SPN/TP MCBs as outgoing double door type sheet metal enclosure 415V with 200 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable for 6 way complete all as specified and as directed . Note : Rates of MCCB and MCB SPN/SP/TP shall be paid under respective item
Supply and laying or fixing in replacement twin sub main cable with 2 x 4 Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable including continouse earth wire 1 x 4 Sqmm copper conductor insulated unsheathed complete all as specified and directed as following:-
In PVC concealed conduit
In PVC casing caping
Supply and laying or fixing in replacement twin sub main cable with 2 x 6 Sqmm multistrand PVC insulated unsheathed copper conductor PVC cable , in pvc casing caping including contineous earth wire 1 x 6 Sqmm copper conductor insulated unsheathed complete all as specified and directed.
In PVC concealed conduit
In PVC casing caping
S & F in replacement of PVC rectangular block of sizes of following size for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing metal/PVC/Wodden boxes with back and top all as directed.
100 mm X100 mm square,50 mm deep
175 mmX100 mm , 50 mm deep
200mmX150 mm , 50 mm deep
250mmX200 mm 50 mm deep
M&L industrial laminated sheet board/hylem sheet of size 6 mm thick of any size for for mounting switches, sockets, fan regulator, etc by punching required slots for switches/Sockets /Regulators as per site requirement including taking down the existing laminated top cover all as directed
Supply and fixing in replacement switch socket combination with box, 2 in 1, 5 pin, 6 Amps flush type all as specified and as directed
Supply and fixing in replacement switch socket combination with box 3 pin , 5/15 Amp flush type, all as specified and as directed
Supply and fixing in replacement 6 A surface 1 way switch all as specified and as directed
Supply and fixing in replacement 6 A surface bell push switch all as specified and as directed
Supply and fixing in replacement 20 A one way switch all as specified and as directed
Supply and fixing in replacement 15 Amps 3 pin plug top all as specified and as directed
Supply and fixing in replacement 5 Amps 3 pin plug top all as specified and as directed
Supply and fix power unit up to 25 Amps including sockets 25 Amps, 04 module box for mounting of power unit and power socket complete as specified and directed power unit .
Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity 25/50 ltrs comprising of the following works complete all as directed. (a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank. (b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required. (c) Inspect overflaw and vent pipes and remove blockages (if any) (d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points (e) Check, maintain and re-fixing thermostat and re-adjust (f) Visual examination of of fusible plugs for its serviceability (g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution (h) Checking of indicator lamp for its serviceability. (j) Re-assembling the geyser, re-installed and testing complete Note:- Spare parts/components of geysers shall be measured and paid seperately as "supply only" under respective items here-in-below. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.)
Supply only heating element, 2KW capapcity, AC 230 volts, pressed/screw/ triangular/ ceramic type, ISI marked complete all as specified and directed.
Supply only heating element, 1.5KW capapcity, AC 230 volts, pressed/ screw/triangular/ ceramic type, ISI marked complete all as specified and directed.
Supply only thermostate element type EST, 11/20 Amp 250 Volt ISI Marked complete all as directed.
Supply only thermostate element type EST, 7/15 Amp 250 Volt ISI Marked complete all as directed
Supply only hot and cold flexible pipe, high pressure with both end brass adopter 18" long ISI marked complete all as directed.
Supply only PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser.
Supply only porclain Heating Element ceramic type suitable for 2 KW geeyser complete all as directed.
Repairing / testing Ceiling fan 1200/1400 mm sweep including rewinding, bush, bearing and fan blade suitable for 240V, ISI marked, 50HZ with regulator complete with all accessories and connection as per manufacturer instruction complete as directed . Note-1) all fans must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length (Note: a) Spare parts should be measured and paid separately . )
Supply only capacitor of capacity 2.5/4 mfd complete all as specified and directed.
Supply only Gun Metal bush suitable for any type of fan complete all as specified and directed.
Supply only ball bearing of No. 6200/ 6201/ 6202/ 6203 complete all as specified and directed.
Repairing / testing exhaust fan/wall mounted fan upto 600 mm sweep including rewinding, bush, bearing and fan blade suitable for 240V, ISI marked, 50HZ with all accessories and connection complete as specified and directed. Note:- (a) all fans must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length. (b) Spare parts should be measured and paid separately.
EASTERN REFRIGERATION AND ELECTRICAL CO
KAMAKHYA TRADERS
KWALITY CONSTRUCTION
SOMANI BUILDERS
S C ROY AND CO
ROY CONSTRUCTION
DK Contractor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .