Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹15.5 L+₹75,720 (5.15%)Rejected-Finance | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹15.7 L+₹1.0 L (7.00%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹17.0 L+₹2.3 L (15.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹24.4 L+₹9.7 L (66.2%)Rejected-Finance | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
26 Apr 2021, 6:00 pmClosed
CWE Ferozepur Cantt
HQ CWE Ferozepur Cantt
CWE/FZR- /2020-21 Repair/Maint of incoming/outgoing VCB, HT Panel and connected itmes at 66 KV MRS and other HT Sub Stn under GE (East) Ferozepur Cantt
2021_MES_408653_2
CWE/FZR-54/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Ferozepur Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (East) Ferozepur
₹30,000
Yes
27 May 2021
6 Apr 2021
28 Apr 2021
6 Apr 2021
26 Apr 2021
13 Apr 2021
Amount
Supply & fix in replacement epoxy body contains upper, middle and lower with 3 bushing suitable for 630/800/1250 Amps VMX type VCB trolly ,11 KV, complete all as specified
Supply and fix in repair relay provided on HT 11KV panel board for incoming & out going feeders in 66 KV MRS & other installation for healthy tripping for over current & earth fault (ASHIDA Numerical OC/EF Protection Relay) complete all as directed and specified.
Supply & fix in replacement auxillary switch Box type 6 NO/NC (3SV92 74) suitable for 630 Amps VMX VCB trolly 11 KV, complete all as specified.
Supply & fix inreplacement shunt trip coil assy 110 Volt DC (OG838) suitable for 630 Amps VMX type VCB trolly ,11 KV, complete all as specified.
Supply & fix in replacement Closing trip coil assy 110 Volt DC (CN-1179) suitable for 630 Amps VMX type VCB trolly 11 KV, complete all as specified
S&F in repair power pack to convert 220 volts AC to 110 Volts DC, along with the switch gear board to cater DC auxiliary supply, complete all as specified.
S&F in repair power convertor input 110-120 volts AC or 200-220 volts AC to output 24 volts DC 2.10 Amp along with switch gear board to cater DC auxiliary supply, complete all as specified.
S&F in repair power module for differential relay along with switch gear board to cater DC auxiliary supply, complete all as specified.
Supply & fix in replacement digital Amp meter of size 4" suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified
Supply & fix in replacement digital volt meter of size 4" suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified
Supply & fix in replacement MCB DP 6 to 32 Amp B curve, complete all as specified.
S&F in repair Current transformer (cast resin) suitable for HT 11 KV Incoming feeder 400/200/5 Amps,three Nos, single phase double core CT of accuracy class. 1.0 and 15 VA, for metering and 15 VA,CL 5P 10 for protection with STR (short time rating ) of 18.4 KA for 1 sec, complete all as specified.
All as per item No 13 above hereinbefore but for outgoing feeder of cap 200/100/5 Amps, complete all as directed and specified.
All as per item No 13 above hereinbefore but for outgoing feeder of cap 300/150/5 Amps, complete all as directed and specified.
All as per item No 13 above hereinbefore but for outgoing feeder of cap 150/75/5 Amps, complete all as directed and specified.
All as per item No 13 above hereinbefore but for outgoing feeder of cap 100/50/5 Amps, complete all as directed and specified.
S& F in repair 11 KV Single phase PT 11 KV/3-110 Volts class1.0 conforming to IS-3156/1992 as per existing make or equavellent as approved by GE.
S&F in replacement of TNC switch, complete all as specified.
Supply & Fix in replacement HT 11 KV shunt capacitor of capacity 275 KVAR outdoor type single phase fixing on existing structure including connection with aluminium bus bar & testing complete all as specified.
Supply & fix in replacement Moving/fixed contacts suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement vaccum interrupter suitable for 1250 Amps VMX type VCB trolly,11 KV, complete all as specified.
Supply & fix in replacement drive insulator assembly with M 10 nylon nut & spl washer of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type VCB trolly, 11 KV, complete all as specified .
Supply & fix in replacement of insulator bush of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type VCB trolly,11 KV. complete all as specified
Supply & fix in replacement socket contact of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement bus bar spouts of VCB compartment suitable for 630/1250 Amps VMX/UNIVAC type type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement contact arm upper suitable for 1250 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement contact arm lower suitable for 630/800 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement jaw contact made out of copper for bushing rod suitable for 1250 Amps VMX type VCB trolly,11 KV, complete all as specified.
M&L for servicing and checking of Incoming/Outgoing VCB trollys of any make, any size, any type, 11 KV, for smooth and proper functioning including checking of all fixed and moving parts, cleaning with thinner and air blower painting the internal parts after grinding/buffing to make rust free and checking of all wiring incl new wiring where ever required and replacment of minor items like nut bolt , washer, locks, springs, on-off switch,Toggle switch,Indicator lamp/Holder etc of any make/or size complete for 66KV MRS, complete all as specified and directed by Engr-in Charge
M&L for calibration and relay setting and checking of Incoming/Outgoing VCB trollys of any make, any size, any type, 11 KV, for smooth and proper functioning including checking of all wiring incl new wiring where ever required complete for 66KV MRS, Power House No-1 and 550 Acre, complete all as specified and directed by Engr-in Charge
Supply & fix in replacement of space heater 240 Volt single phase, complete all as specified.
Supply & fix in replacement of thermostat 240 Volt single phase range settting from 0 to 90 degree centigrade, complete all as specified.
Supply & fix in replacement CT bushing suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement upper bushing L1 CU suitable for 1250 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement upper bushing L2 CU suitable for 1250 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement upper bushing L3 CU suitable for 1250 Amps VMX type VCB trolly 11 KV, complete all as specified.
Supply & fix in replacement bushing lower CU suitable for 1250 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement anti pumping contactor, 2NO+2NC suitable for 630 Amps VMX type VCB trolly, 11 KV, complete all as specified.
Supply & fix in replacement bushing rod suitable for 1250 Amps VMX type VCB trolly ,11 KV, complete all as specified.
Supply & fix emergency charging handle for motor machanism suitable for 1250/630 Amps VMX type VCB trolly,11 KV. complete all as specified.
S&F weather proof twin core sheathead multistrand copper cable of 2.5 sqmm for DC protection system to VCB No 4 transformer at 66 KV MRS, complete all as specified.
S&F weather proof twin core sheathead multistrand copper cable of 4 sqmm for DC protection system to VCB No 4 transformer at 66 KV MRS, complete all as specified.
Salhotra contractors
Vee Vee Enterprises
R D Bansal
M/S Yashpaul Gulati
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .