Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance SHOP NO 5 BACHAT BHAWAN UNA TEHSIL UNA HP 174303 | UNA | UNA | HP | 174303 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance MAIN BAZAR GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance H NO 199 W NO 6 NEAR OLD SDM OFFICE DISTT HAMIRPUR HP 177001 | HAMIRPUR | HAMIRPUR | HP | 177001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
20 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Electrical Division HPPWD Una
Executive Engineer Electrical Division HPPWD Una
Construction of Multipurpose Culture Centre at Samoorkalan Distt.Una HP SH Providing Main Panel Sub main cable Sub main Split type Air Conditiner Gyser S.O.P. therein
2021_PWD_45006_1
PW-EDU-CB-TA-Tender-2020-21- 4825-44 Dt-22-02-2021
Open Tender
Electrical Works
Item Rate
90 days
Una
Please refer tender document
6 documents required · 6 mandatory
₹500
EE Electrical
₹36,000
22 Mar 2021
4 Mar 2021
22 Mar 2021
4 Mar 2021
20 Mar 2021
4 Mar 2021
120 days
Amount
Supplying and erection of following depth sheet metal cubical pedestal of suitable dimensions with plus-minus 5 cm variation made from (50 mm x 50 mm x 6 mm thick) M.S. angle iron frame, covered with 1.6 mm thick M.S. sheet duly welded on five sides & front side hinged, complete with locking arrangement with sufficient No. vertical and horizontal intermediate switchgear supporting members each of M.S. flat 50mmx6mm thick of suitable length duly welded. The cubical pedestal shall have cable entry box at one or two sides and 4 No. legs of 50mmx50mmx6mm thick M.S. angle iron each 60 cm long including, powder coated painting and bonding to the existing earth etc., the same shall be erected in the 1:2:4 cement concrete plat-form of suitable dimensions 15 cm high from ground level and 45 cm thick. The cubical pedestal shall be 15 cm from the top of cement concrete plat-form:-(EVA,Power & Control System,Supertech make or its equivalent approved make)The panel should be approved /Tested from the CPRI lab.& should confirmed to ISI: 64139
300 mm deep (nominal)
Supplying and fixing sheet metal bus-bar chamber suitable for 63 Amp. 415 volts capacity with 4 No. copper strip bus-bars each of length 300mm & cross-sectional area (16mmx3.17mm), enclosure made from 1.6 mm thick M.S. sheet having overall dimensions (380mmx350mmx150mm) nominal with all accessories including connections, earthing the body etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing copper strip bus-bars suitable for 63 Amp. 415 volts capacity 4 No. each of cross-sectional area (16mmx3.17mm),in the existing enclosure with all accessories including connections etc. as required:-(Legrand/Schneider/Siemens make)
Supplying and fixing copper strip bus-bars suitable for 1000 Amp. 415 volts capacity 4 No. each of cross-sectional area (50.80mmx12.70mm),in the existing enclosure with all accessories including connections etc. as required:-(Legrand/Schneider/Siemens make)
Providing and fixing following rating and breaking capacity MCCB in the existing cubical panel board including drilling holes in the cubicle panel, making connections, etc. as required.(Legrand/Hagger/ABB/L&T make)
100 Amp. -10 KA
160 Amp. -16 KA
315/400 Amp. -35 KA
800 Amp. -50 KA
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Legrand/Hagger/ABB/L&T make)
Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:-(Legrand/Hagger/ABB/L&T make)
Double pole. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Legrand/Hagger/ABB/L&T make)
40 Amps. Cat-A.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-(Legrand/Hagger/ABB/L&T make)
Double door-16 way
Earthing with copper earth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for earth connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long copper tube, having single prong at top, with 85 mm dia 3 mm thick copper base plate including holes etc. complete as required.
Riveting, sweating and soldering of copper/ G.I. tape ( with another copper/G.I. tape, base of the finial or any other metallic object) as required.
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for vertical run)
Supplying and fixing copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as required ( for horizontal run)
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:-( Make :- Diplast/Polypack 2 mm.thick)
50 mm. dia
Supplying & fixing metal box of following sizes (nominal size) on surface or in recess suitable for fixing phenolic laminated sheet cover in front including painting etc. as required:-
250mm.x300mm.x100mm. deep
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:-(KEI/Polycab/Havells or its equivalent make)
Armoured cable 50 sq. mm (3.5 core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 630 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-(KEI/Polycab/Havells or its equivalent make)
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 50 sq. mm (3.5 core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 630 sq. mm (3.5 core)
Providing and laying of aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground in the same trench, in one tier horizontal formation to be laid 1 meter below the ground level including excavation and refilling the trench etc.as required, but excluding sand cushioning and protective covering etc. of required size:-(KEI/Polycab/Havells or its equivalent make)
Armoured cable 25 sq. mm (3.5 core)
Armoured cable 50 sq. mm (3.5 core)
Armoured cable 95 sq. mm (3.5 core)
Armoured cable 630 sq. mm (3.5 core)
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- Make:- Usha/Recold/ Jaquar(Min. 3 star rating).
35 Liter capacity water heater (Cat-A)
50 Liter capacity water heater (Cat-A)
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required. Make :-Legrand (Myrius)/L&T (Oris) / Anchor ( Roma plus)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- (Usha - SPH Turbo HDEF 900 RPMISI or its Equivalent make)
Providing, Installation, testing and commissioning of ceiling fan without regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Ceiling fan 1200mm sweep ( Usha-Technixplus BEE 3 Star rated model) or its equivalent make)
Supplying and fixing exhaust fan louver shutter for 300 mm.exhaust fan on the existing wall,painting etc, as required.(National or its equivalent make)
Supplying and fixing wall fan 450 mm.sweep,AC.supply,240 volts,50 HZ high speed on the existing wall complete with connections,testing and commissioning etc,as required.(Usha 450 mm.Dominaire wall fan or its equivalent make )
Providing and fixing MCCB four pole 63 amps.rating and 18 KA breaking capacity 415 volts AC.supply 50 HZ four pole DU 100 D type in the existing enclosure including making connections etc,as required. (L&T/ABB/Siemens make)
Providing and fixing MCCB enclosure for DU 100 D/DU MCCB following rating on the existing board complete as required.(L&T/ABB/Legrand make)
Supplying and fixing LED digital mounting Ammeter 0 to 500 Amps.3 phase of size 96x96 sq.mm.flush mounting in the existing pannel complete with connections etc, as required.(L&T make Cat.No.WL131020OOOO or its equivalent make )
Supplying and fixing LED digital mounting Voltmeter 0 to 500 Amps.3 phase of size 96x96 sq.mm.flush mounting in the existing pannel complete with connections etc, as required.(L&T make Cat.No.WL132020OOOO or its equivalent make)
Supplying and fixing Coolio Fuzi LED Panel indicating set R,Y and B with 3 Nos.Kit kat (Neon type) to shown the three phase indicating in the existing panel complete with connections etc, as required.
Supplying and fixing of Rubber matt 1x2 mtrs.long 2.5 mm. thick (Jyoti) in the front of main panel etc,as required
Supplying and fixing shock trearment chart in main panel room on the existing wall etc, as required
Supplying and fixing C.T.coil 100/5 Amps.in the existing pannel complete with connections etc,as required.
Supplying and laying G.I.pipe of 50 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
Supplying and laying G.I.pipe of 100 mm. dia (Heavy duty) underground 1.00 mtr.below ground level for laying the wire/cable etc, as required
S/F of 1.5 ton split type air conditioner as per Invertor 4 star model No.(R32) Copper Hot & cold or its equivelent make & model better star rating-2 virus safe fittrer,triple filter,E-saver mode.Quit mode,white display,auto clean.Anti Bacteria filter jet cool ON/OFF timer,sleep mode compressor cordless remote complete in all respects or any other equivelent make as per Voltas comprising to ISI with latest amensment suitable to operate on 230/240 volts +/- 10% AC.supply capable to perform the function of cooling dehumidification air circulation,ventilation and fitting in the size of nominal cooling capacity complete with 4 KVA automatic voltage stabilizer Microtek make model EM4140+ confiming to ISI specifications.The stabilizer should have high voltage trip and MCB high low voltage trip and time relay complete in all respects.inluding drain pipe 20 mm.dia approximatelly 3 mtrs.long,2 No.copper pipe with insulator for inlet and outlet approximatelly 3 mtrs.long and M.S.power coated frame/stand for errection of out door unit of split type A.C.including carriage of material with in all leads & lifts.(Voltas make Cat No.184 VSZSFioral or its equivalent make)
SHARMA ELECTRICAL CO.
Himat Raj Thakur
NITIN PROP A VIGHNA ELECTRICALS
Ratwan Light House
stage.html
html • 0.02 MB
finance_67602.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .