Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-Finance 10 370 NEAR GEETA MANDIR GAS GODAM ROAD OBRA OBRA SONBHADRA UTTAR PRADESH 231219 INDIA | SONBHADRA | UTTAR PRADESH | 231219 | L1 | Accepted-Finance Financially qualified | |
| 2 | L2₹13.8 L+₹1.4 L (11.4%)Accepted-Finance 245 RAJABPUR RAJABPUR RAJABPUR JYOTIBA PHULE NAGAR UTTAR PRADESH 244236 | AMROHA | UTTAR PRADESH | 244236 | L2 | Accepted-Finance Financially qualified | |
| 3 | Rejected-Technical | - | Rejected-Technical Requisite work experience not submitted | |
| 4 | Rejected-Technical NEAR KRAYA VIKRAY SAMITI ASHOK NAGAR DISTRICT FATEHPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | - | Rejected-Technical Work completion certificate of attached LOI not submitted |
Tender Value
₹15.2 L
EMD Value
₹25,000
Closing Date
19 Jul 2021, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer OMC-II,CTPS,PTPP Parichha
Office of The Superintending Engineer, Operation and Maintenance circle-II, 2X250 MW, CTPS, Parichha, Jhansi.
Round the clock preventive maintenance, up-keeping, attending of minor nature of faults of ID/FD/PA fans and dampers, actuators for meting out operational requirements of unit no. 5 6 of 2x250MW CTPS, Parichha, Jhansi
2021_RVUNL_594207_1
T-09/OMC-II/BMD-II/2X250 MW/CTPS/2021-22
Open Tender
Power/Energy Projects/Products
Lump-sum
365 days
BMD-II, CTPS, PTPP
As per PQC
2 documents required · 2 mandatory
₹1,180
Dy.C.A.O.PTPP Parichha
₹25,000
28 Jul 2021
11 Jun 2021
20 Jul 2021
11 Jun 2021
19 Jul 2021
11 Jun 2021
11 Jun 2021 - 19 Jul 2021
120 days
Amount
Round the clock routine and preventive maintenance of ID/FD/PA Fans of U#5
Round the clock routine and preventive maintenance of ID/FD/PA Fans of U#6
Break-down maintenance of ID fan:-
Servicing of ID Fan
Replacement of thrust Pads and DE bearing
Replacement of NDE bearing
Replacement of ID Fan Impeller/Shaft
Servicing of IGV
Replacement of the liner blades
Repairing of Impeller casing
Cleaning of Impeller casing
Checking and servicing of NDE bearing
Checking and servicing of DE bearing
Alignment of ID fan with hydraulic coupling .
Alignment of ID fan hydraulic coupling/FD Fan /PA fan with motor
Servicing of hydraulic coupling of oil cooler (One cooler makes one job).
Servicing of Lube Oil cooler .
Installation of new/healthy lube Oil Pump
Replacement of mechanical seal/bearing /replacement of cartridge of lube oil pump
Checking /Servicing of lube oil system
Checking /Servicing of outlet/inlet gate.
Servicing of hydraulic coupling
Replacement of impeller sealing ring
Repairing of impeller sealing ring
Removal and Installation of Coupling of “Variable Speed Coupling of ID Fan”(Drive End Side)
Removal and Installation of Coupling of “Variable Speed Coupling of ID Fan”(Non Drive End Side)
Cleaning of Duct of ID Fan damper to Chimney (One job Consists of both Fans)
Cleaning of Duct of ESP outlet to Fan suction damper including common ducts (One job Consists of both Fans)
Replacement of oil of Hydraulic coupling of ID Fan
Breakdown maintenance of FD Fans.
Servicing of FD Fan
Dismantling/checking/mounting of shaft with bearing assembly
Checking /servicing of oil seal of DE/NDE side bearing
Arresting leakage from oil pipe hose and cable of the temperature probe from the main bearing/hydraulic adjust heat device.
Checking /changing blade shaft bearing
Assembly of the blade and the adjusting lever
Changing/servicing of impeller servomotor
Checking & servicing of damper
Servicing of lube oil system
Servicing of lube oil pump
Checking /changing shim of connecting rod between control head and limit switch of fan
Servicing of rotor assembly of FD Fan
Removal and Installation of Coupling of FD/PA Fan.
Replacement of lube oil of oil tank of PA/FD/ID Fans and Cleaning of oil tank and associated Pipe Lines
Break-Down maintenance of PA Fans
Servicing of PA Fans
Dismantling/checking/mounting of shaft with bearing assembly
Checking /servicing of oil seal of DE/NDE side bearing
Arresting leakage from oil pipe hose and cable of temperature probes from the main bearing assembly
Checking/changing blade shaft bearing
Assembly of the blade and the adjusting lever
Changing/servicing of impeller servomotor
Servicing of lube oil system
Servicing of lube oil pump
Checking /Servicing of outlet gate
Checking/changing shim of connection rod between control head and limit switch
Inspection of ID/FD/PA Fan from inside.
Repairing /Sizing of old/new coupling of Lube Oil Pump of FD/PA Fan.
U.S.Enterprises
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .