Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-Finance | L1 | Accepted-Finance DOC COMPLETE | |
| 2 | L2₹7.6 L+₹3.0 L (65.7%)Accepted-Finance | L2 | Accepted-Finance DOC COMPLETE | |
| 3 | Rejected-Technical | - | Rejected-Technical doc not complete |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
1 Sept 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC-2, Meerut
SE, EDC-2, Meerut
TNO.13/EDC2MT/2025-26
2025_PVVNL_1040169_4
TNO.13/EDC2MT/2025-26
Open Tender
Electrical Works
Lump-sum
180 days
EDD-MAWANA
TNO.13/EDC2MT/2025-26
2 documents required · 2 mandatory
₹1,180
SE, EDC-2, Meerut
₹5,000
4 Sept 2025
26 Aug 2025
1 Sept 2025
26 Aug 2025
1 Sept 2025
26 Aug 2025
Amount
Cartage of following material from store center Meerut to J.E. store including loading & unloading at both ends maximum distance up to 40 km. :-(as per direction of Executive Engineer for successful completion of work.)
A) P.C.C. Pole 8.5 Mtr Long.
B) Round Pole/STP Pole 11 Mrt Long.
C) Line material such as 11 KV Cross arm/conductor/GI wire/MS angle & MS Channel/Stay rod, disk fitting etc.
Cartage of the following material from store J.E. to site of work including loading & unloading at both ends (maximum distance up to 15 km.) A) P.C.C. Pole 8.5 Mtr Long.
B) Round Pole/STP Pole 11 Mrt Long.
C) Line material such as 11 KV Cross arm/conductor/GI wire/MS angle & MS Channel/Stay rod, disk fitting etc.
Safe cartage of Transformer from Central store Meerut to J.E. Store of work Including loading & unloading at both ends ( maximum distance up to 40 km.) A) 630 KVA TO 250 KVA
B) 100 KVA to 63 KVA
C) 25 KVA to 10 KVA
Safe cartage of Transformer from J.E. Store to side of work Including loading & unloading at both ends ( maximum distance up to 15 km.) A) 630 KVA TO 250 KVA
B) 100 KVA to 63 KVA
C) 25 KVA to 10 KVA
Erection of Round pole/PCC pole 8.5 Mtr long including fixing all accessories and fabrication as required after digging a pit of size 1.20x0.75x1.75 mtrs. As follows. A) PCC Pole.
B) Round Pole/ST Pole 11 mtr. Long.
Erection of D/P on PCC/Round Pole after digging a pit of size 1.20x0.75x1.75 mtrs including fabrication of structure as per RESPO Noms.
Earthing of PCC/STP support with MS Earth rod of 2.5 mtr. Long including excavation of pit & driving of MS rod up to proper depth & connection the earth eletrode with the help of GI wire.
Grouting of STP support with Dust, sement & stone Blast
Laying Lifting stringing and sagging of conductor complete in all respects as per RESPO norms. As follows : - A) Rabbit Conductor/ Weasel Conductor.
B) Dog Conductor.
Erection fixing & grouting of stay rod size 16x1800 mm after digging the pit of size 0.60x0.30x0.30 meter in ratio 1:4:8 including fixing of stay wire clamp and nuzzling at the both ends.
Straightening of tilled PCC Pole of 11 KV/LT Lines after opening the binding from insulators and digging the pit for require depth and refilling the same pit after completion of work including rebinding the conductor with insulators & sagging the conductor.
Mounting fo 11/0.4 KV T/F on pilnth & making Connection of PCC Cables & Lead of HT/LT line. As follows :- A) 630 KVA to 250 KVA
B) 100 KVA to 63 KVA
C) 25 KVA to 10 KVA
Providing & Fixing of following clamps for PCC Poles/ STP, made of MS flat of size 50x50 mm complete in all respects. A) LT Pin Clamps with nut & bolt.
B) Shackle Insulator with nut & bolt.
C) Holding Clamps with nut & bolt.
D) F Clamps with nut & bolt.
E) Double Pole Clamps with nut & bolt.
Providing & fixing of stay clamp for PCC Pole/STP made of MS flat of size 50x6 mm complete in all respect.
Providing & fixing of Stay insulator in stay wire as per site requirement.
Fabrication of cross arm from given MS Channel from making T/Section of HT Lines.
Providing D-Type loop on each face & neutral.
providing & fixing of bamboo sticks of required size on LT Line as per instruction of JE. Concerned.
Making section T-off for 11 KV/LT Line.
Reflxing of old stay after digging of pole of regard size & then groting of stay on site required.
Cutting & Chopping of tree branches.
Jumpering of 11 KV/LT Line at different places/T points.
Fixing of meter Cubicle & making connection & other related works.
Guarding of 11 KV Line as per norms.
Cartage of 11 KV XLPE Cable of various size from store center Meerut to J.E. store including loading & unloading at both ends maximum distance up to 40 km. :-
Cartage of 11 KV XLPE Cable of various size from JE store to site including loading & unloading at both ends maximum distance up to 15 km. :-
Laying Lifting Stringing of proper Sagging of 11 KV XLPE Cable of various size with fitting jointing Kit different size
Repair/Replacement of damaged burnt jumpers of double pole/section pole of 11 KV/LT Line.
Cartage of ABC Cable with junction box & other store materials related with the work of ABC for each site/Transformer.
Laying Lifting of ABC Cable complete in all respect as per instrution of JE/SDO.
Fixing of Junction Box & making connection & other related works.
Fixing of TPMO at D/P.
Fixing of fuse set at D/P.
New LT PVC Cable of T/F, :- 100 KVA to 63 KVA, 25 KVA
Water level Earthing (Neutral/Body) by providing & fixing 30 mtrs 30 mm dia GI Pipe with MS Strip 40x6 mm, lowering the same after boring of earth by 4" dia upto 30 Mtr depth/water level.
Fixing of 11KV Jointing Kit of Different Size 3x185, 3x120, 3x70
Fixing of 11KV CT/PT Unit of Different Size
Making new Plinth for 250/630 KVA T/F for imstallation new T/F, as per RESPO Norms ( all the material used shall be Provide by the conractor),
Wireness Fancing of 250/630 KVA T/F. Complate
R. P. T. Electrical (BID ID -5507116)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .