Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹41.0 L+₹4.6 L (12.8%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹43.3 L+₹7.0 L (19.2%)Rejected-Finance 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹43.9 L+₹7.5 L (20.7%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹46 L+₹9.6 L (26.5%)Rejected-Finance 402 C WING BUILDING NO 86 NAVRANG CO OP HSG SOCIETY LTD TILAKNAGAR CHEMBUR MUMBAI 89 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400089 | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | HARNAM SINGH ANIL SINGH L8 | M/S Kumar Contractors L2 | S GOURAV PRAKASH ENTERPRISES L6 | M/S SHIVA TRADERS L9 | ROHIT ENTERPRISES L4 | VIJAY BUILDERS L3 | Sai construction & services L5 | M/S LAKSHYA CONSTRUCTIONS L7 | ADARSH ENTERPRISES L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for surface preparation - Concrete floor should be clean, sound and free from contamination such as oil and grease, mortar and paint splashes or curing compound residues and previously done resin flooring, etc. These deposits are best removed by mechanical grinding/scarification or light shot blasting followed by thorough cleaning using vacuum cleaners. Removal of all oil, grease, etc can also be done using a degreasing solution and brushing the floor with hard broom or wire brush and then detergent washing and mopping. If wetting of the floor has taken place during preparation, it must be allowed to dry out (surface moisture content should be less than 5%) before commencement of EPU floor application. All cracks and construction joints need to be cut open. Cracks need to be cut open in a 5mm x 5mm groove and construction joints at full width up to 1/3 rd depth of the concrete thickness or till the loose concrete and to be filled with rigid epoxy putty (as per manufactures specifications), complete all as specified and directed. | 1,600 | Sqm | 80 ₹1,28,000 | 80 ₹1,28,000 | 60 ₹96,000 | 200 ₹3,20,000 | 100 ₹1,60,000 | 50 ₹80,000 | 60 ₹96,000 | 146 ₹2,33,600 | 10 ₹16,000 Lowest |
| 2.00 | Supplying and applying 5 mm thick heavy duty, chemical resistant, abrasion resistant Epoxy Polyurethane Flooring system over old concrete surface (3 mm thick epoxy primer/ scratch coat and screed + 2 mm thick self leveling/ smoothing top coat) -
(i) Immediately prior to priming, the surface (application area) should be thoroughly cleaned to remove any remaining traces of dust or other loose materials using suitable means. Providing and applying solvent free epoxy primer at a coverage rate (Base : Hardener proportion as per manufactures specification) in two coats using a brush or short/ medium pile roller at a time gap of 8 hrs, ensuring a uniform coating is achieved, allowing second coat to dry for 24 hrs or as per manufacturers instructions, care should be taken to avoid over application.
(ii) Providing and applying a epoxy screed (Base : Hardener : Aggregate) at a coverage rate (as specified by the manufacturer) of up to a nominal 3 mm thick (including thickness of epoxy primer) over prepared (old) concrete floor (application area) using a notched trowel or a pin screed. Immediately roll the spread material with spiked roller to release all entrapped air and remove trowel marks. The rolling should be carried out using a back and forth technique along the same path. An overlap of 50% with adjacent path is recommended. The screed should be allowed to cure for 12-48 hours at 20 o C before applying top coat.
(iii) Providing and applying a self leveling/ smoothing top coat of EPU resin (Base : Hardener : Aggregate : Color pack) at a coverage rate (as specified by the manufacturer) of up to a nominal thickness 2mm over previously cured surface of epoxy screed using notch trowel or pin screed and using the approved color shade. Immediately roll the spread material with spiked roller to release all entrapped air and remove trowel marks. The rolling should be carried out using a back and forth technique along the same path. An overlap of 50% with adjacent path is recommended. The finished surface should be protected from other trades using kraft paper or similar breathable material. Polythene should not be used. Protect the installed floor from damp, condensation and water for at least 4 days, complete all as specified and directed. | 1,600 | Sqm | 2,200 ₹35,20,000 | 1,850 ₹29,60,000 | 2,200 ₹35,20,000 | 2,300 ₹36,80,000 | 1,975 ₹31,60,000 | 1,850 ₹29,60,000 | 1,900 ₹30,40,000 | 2,100 ₹33,60,000 | 1,650 ₹26,40,000 Lowest |
| 2.01Note for Ser Item No 1 & 2 :- (i) Anchorage groove cutting by mechanical cutter machine with double size of proposed PU floor thickness to all end points of flooring, offsets and as per the instruction of manufacturer should be provided without any extra cost before application of primer/ scratch coat. (ii) Component of product in required proportions (as per the manufacturers instructions) to be mixed using a forced- action rotary paddle mixer up to recommended time of mixing. (iii) Primer/ scratch coat and top coat should be applied by specialist applicator who must follow procedure and guidelines specified by manufacturer or code of practices. The cured/ final surface shall exhibit the following minimum typical properties :- Compressive strength @ 28 days - 50 N/mm2, Tensile strength - 6.5 N/mm2, Flexural strength - 18 N/mm2, Density - 1900 Kg/Cum, Water absorption - 0.06 %, Coefficient of thermal expansion 4X10 -5 / oC and Flame spread classification - Class 2. | ||||||||||||
| 3.00 | Providing and applying 125mm wide in two coats of traffic marking lines to achieve a total dry film thickness 90 microns over EPU flooring using high performance epoxy resin floor coating in required colour shade and pattern, applied using spray/ brush or lambs wool roller as per manufacturers instructions, complete all as specified and directed. | 500 | RM | 200 ₹1,00,000 | 80 ₹40,000 | 120 ₹60,000 | 200 ₹1,00,000 | 150 ₹75,000 | 150 ₹75,000 | 160 ₹80,000 | 75 ₹37,500 Lowest | 120 ₹60,000 |
| 4.00 | M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floor, base etc, finishing cement concrete surface even and smooth without using extra cement , complete all as specified and directed. | 250 | Sqm | 200 ₹50,000 | 100 ₹25,000 Lowest | 198 ₹49,500 | 100 ₹25,000 Lowest | 130 ₹32,500 | 130 ₹32,500 | 300 ₹75,000 | 200 ₹50,000 | 110 ₹27,500 |
| 5.00 | Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar. Complete all as specified | 6.25 | Cum | 200 ₹1,250 | 100 ₹625 Lowest | 200 ₹1,250 | 200 ₹1,250 | 1,000 ₹6,250 | 200 ₹1,250 | 780 ₹4,875 | 300 ₹1,875 | 250 ₹1,562.5 |
| 6.00 | Supply, installation, testing and commisioning of air cooled inverter split Air conditioner
(All weather) of 2 TR capacity comprising of one indoor and one outdoor unit, wall mounted type comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having Five Star rated with and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit and outdoor unit installed in wall mounted clamp complete with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed.
Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and Electrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect. | 12 | Each | 80,000 ₹9,60,000 | 64,000 ₹7,68,000 | 65,000 ₹7,80,000 | 80,000 ₹9,60,000 | 66,000 ₹7,92,000 | 80,000 ₹9,60,000 | 62,500 ₹7,50,000 | 72,000 ₹8,64,000 | 59,000 ₹7,08,000 Lowest |
| 7.00 | Supply, connect & testing of automatic voltage stabilizer, wall mounted type for low voltage cut-off, single phase, AC, 50 Hz, 15 Amps rating ,of capacity 5 KVA suitable for input voltage range 160V-280V AC with 3min±20 sec delay for Air Conditioner Complete all as specified and directed. | 12 | Each | 8,000 ₹96,000 | 6,000 ₹72,000 | 4,500 ₹54,000 | 10,000 ₹1,20,000 | 5,000 ₹60,000 | 8,000 ₹96,000 | 2,600 ₹31,200 Lowest | 3,500 ₹42,000 | 4,800 ₹57,600 |
| 8.00 | M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4.0 sqmm + 1 run x 4.0 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge.
Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length. | 226 | RM | 170 ₹38,420 | 150 ₹33,900 Lowest | 150 ₹33,900 Lowest | 180 ₹40,680 | 150 ₹33,900 Lowest | 200 ₹45,200 | 1,248 ₹2,82,048 | 248 ₹56,048 | 200 ₹45,200 |
| 9.00 | Supply and fix of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 20A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board all as specified and directed. | 12 | Each | 600 ₹7,200 | 500 ₹6,000 Lowest | 1,500 ₹18,000 | 1,000 ₹12,000 | 600 ₹7,200 | 650 ₹7,800 | 1,580 ₹18,960 | 2,000 ₹24,000 | 650 ₹7,800 |
Tender Value
₹64 L
EMD Value
₹1.2 L
Closing Date
27 Oct 2025, 6:00 pmClosed
SHRI ANIL KUMAR, IDSE, SE, CWE
HQ CWE JHANSI
REPLACEMENT OF EXISTING FLOOR WITH EPOXY POLY URETHANE FLOOR (IN 6 R AND O FLT HANGER BLDG NO P-1) AND PROVN OF 12 X 2 TON SPLIT AC ALONG WITH CONNECTED ITEMS UNDER GE JHANSI
2025_MES_732743_1
CWE/JHA/J/TOKEN/49 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
JHANSI
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE JHANSI
₹1.2 L
Yes
27 Nov 2025
26 Sept 2025
29 Oct 2025
26 Sept 2025
27 Oct 2025
18 Oct 2025
Amount
M&L for surface preparation - Concrete floor should be clean, sound and free from contamination such as oil and grease, mortar and paint splashes or curing compound residues and previously done resin flooring, etc. These deposits are best removed by mechanical grinding/scarification or light shot blasting followed by thorough cleaning using vacuum cleaners. Removal of all oil, grease, etc can also be done using a degreasing solution and brushing the floor with hard broom or wire brush and then detergent washing and mopping. If wetting of the floor has taken place during preparation, it must be allowed to dry out (surface moisture content should be less than 5%) before commencement of EPU floor application. All cracks and construction joints need to be cut open. Cracks need to be cut open in a 5mm x 5mm groove and construction joints at full width up to 1/3 rd depth of the concrete thickness or till the loose concrete and to be filled with rigid epoxy putty (as per manufactures specifications), complete all as specified and directed.
Supplying and applying 5 mm thick heavy duty, chemical resistant, abrasion resistant Epoxy Polyurethane Flooring system over old concrete surface (3 mm thick epoxy primer/ scratch coat and screed + 2 mm thick self leveling/ smoothing top coat) - (i) Immediately prior to priming, the surface (application area) should be thoroughly cleaned to remove any remaining traces of dust or other loose materials using suitable means. Providing and applying solvent free epoxy primer at a coverage rate (Base : Hardener proportion as per manufactures specification) in two coats using a brush or short/ medium pile roller at a time gap of 8 hrs, ensuring a uniform coating is achieved, allowing second coat to dry for 24 hrs or as per manufacturers instructions, care should be taken to avoid over application. (ii) Providing and applying a epoxy screed (Base : Hardener : Aggregate) at a coverage rate (as specified by the manufacturer) of up to a nominal 3 mm thick (including thickness of epoxy primer) over prepared (old) concrete floor (application area) using a notched trowel or a pin screed. Immediately roll the spread material with spiked roller to release all entrapped air and remove trowel marks. The rolling should be carried out using a back and forth technique along the same path. An overlap of 50% with adjacent path is recommended. The screed should be allowed to cure for 12-48 hours at 20 o C before applying top coat. (iii) Providing and applying a self leveling/ smoothing top coat of EPU resin (Base : Hardener : Aggregate : Color pack) at a coverage rate (as specified by the manufacturer) of up to a nominal thickness 2mm over previously cured surface of epoxy screed using notch trowel or pin screed and using the approved color shade. Immediately roll the spread material with spiked roller to release all entrapped air and remove trowel marks. The rolling should be carried out using a back and forth technique along the same path. An overlap of 50% with adjacent path is recommended. The finished surface should be protected from other trades using kraft paper or similar breathable material. Polythene should not be used. Protect the installed floor from damp, condensation and water for at least 4 days, complete all as specified and directed.
Note for Ser Item No 1 & 2 :- (i) Anchorage groove cutting by mechanical cutter machine with double size of proposed PU floor thickness to all end points of flooring, offsets and as per the instruction of manufacturer should be provided without any extra cost before application of primer/ scratch coat. (ii) Component of product in required proportions (as per the manufacturers instructions) to be mixed using a forced- action rotary paddle mixer up to recommended time of mixing. (iii) Primer/ scratch coat and top coat should be applied by specialist applicator who must follow procedure and guidelines specified by manufacturer or code of practices. The cured/ final surface shall exhibit the following minimum typical properties :- Compressive strength @ 28 days - 50 N/mm2, Tensile strength - 6.5 N/mm2, Flexural strength - 18 N/mm2, Density - 1900 Kg/Cum, Water absorption - 0.06 %, Coefficient of thermal expansion 4X10 -5 / oC and Flame spread classification - Class 2.
Providing and applying 125mm wide in two coats of traffic marking lines to achieve a total dry film thickness 90 microns over EPU flooring using high performance epoxy resin floor coating in required colour shade and pattern, applied using spray/ brush or lambs wool roller as per manufacturers instructions, complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in floor, base etc, finishing cement concrete surface even and smooth without using extra cement , complete all as specified and directed.
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar. Complete all as specified
Supply, installation, testing and commisioning of air cooled inverter split Air conditioner (All weather) of 2 TR capacity comprising of one indoor and one outdoor unit, wall mounted type comprise of copper pipe heat exchangers, having non CFC refrigerant, electric driven, 230 Volts AC, single phase, 50 Hz, having Five Star rated with and including inlet/outlet copper pipe for refrigerant between indoor & outdoor unit and outdoor unit installed in wall mounted clamp complete with flexible copper wire of suitable size as recommended by manufacturer, complete all as specified and directed. Note: The cost of making hole / opening for passing inlet/ outlet copper pipes and Electrical cord and making good surface as original by plastering / applying putty/ whitewash/colour/distemper etc is included in quoted rate and no extra payment will be made to contractor in this effect.
Supply, connect & testing of automatic voltage stabilizer, wall mounted type for low voltage cut-off, single phase, AC, 50 Hz, 15 Amps rating ,of capacity 5 KVA suitable for input voltage range 160V-280V AC with 3min±20 sec delay for Air Conditioner Complete all as specified and directed.
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4.0 sqmm + 1 run x 4.0 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length.
Supply and fix of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 20A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board all as specified and directed.
S&F of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately.
S&F of MCCB 100A, 10 KA, TP, 415 V, 50 Hz complete all as specified and directed.
S& F MCB SP 6-32 Amp, 240 V with breaking capacity 10 KA, 'C' series complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 35 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in any type of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M/S Kumar Contractors (BID ID -3459660)
VIJAY BUILDERS (BID ID -3465697)
ROHIT ENTERPRISES (BID ID -3465476)
Sai construction & services (BID ID -3460481)
S GOURAV PRAKASH ENTERPRISES (BID ID -3460518)
M/S LAKSHYA CONSTRUCTIONS (BID ID -3460439)
HARNAM SINGH ANIL SINGH (BID ID -3459548)
M/S SHIVA TRADERS (BID ID -3460767)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
Tenderdocuments49.pdf
Tender Documents • 1.55 MB
BOQ_820417.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .