Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹5.5 L
EMD Value
₹5,500
Closing Date
27 Aug 2024, 3:00 pmClosed
SE EDC-II GORA BAZAR RAEBARELI
SE EDC-II GORA BAZAR RAEBARELI
ELECTRICAL WORK UNDER BP 2024-25 AT EDD DALMAU
2024_MVVNL_943815_1
33/EDC-II,R/2024-25
Open Tender
Electrical Works
Item Rate
30 days
EDD DALMAU
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
ICICI BANK A/C 081205500344/ IFS CODE ICIC0000812
₹5,500
Yes
2 Sept 2024
5 Aug 2024
28 Aug 2024
7 Aug 2024
27 Aug 2024
7 Aug 2024
Amount
Safe loading & carriage including Loading-unloading & proper stacking at a Place of following store materials from ESC Tripula to site of work.
1- 11 KV VCB INCOMMING 600/300/5A-350 MVA 2- 11 KV VCB OUTGOING 200/100/5A
11 KV XLPE Cable 300 sq.mm for laying of Second Circuit for incomming .
11 KV XLPE Cable 185 sq.mm for laying of Second Circuit for Outgoing Feeder 01 No.
11 KV XLPE Cable 120 sq.mm for laying of Second Circuit for Railway Crossing Asariyawan
33 KV XLPE Cable 300 sq.mm for laying of Second Circuit for incomming .
Cable jointing Kit for 300 sq.mm 11 KV XLPE Cable
Cable jointing Kit for 185 sq.mm 11 KV XLPE Cable
Cable jointing Kit for 120 sq.mm 11 KV XLPE Cable
Cable jointing Kit for 33 KV sq.mm XLPE Cable
Labour and Errection Charges:-
Complete Installation of 11 KV VCB INCOMMING 600/300/5A-350 MVA with all required accessories as per RESPO Norms.
Installation of11 KV VCB OUTGOING 200/100/5A with all required accessories as per RESPO Norms.
Earthing of 11 KV VCB, including cost of materials (M.S. Flat 50*6 mm Pipe, Mat. Etc. As per RESPO Norms, All required Material Provided by Contractor.
Laying of Double circuit Line of 11 KV 300 SQ.MM XLPE cable in normal soil by digging of trench 2X3 Feet 80 Mtr Deep in G.I. Pipe 6" Dia including encluding required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks. Distance as per Estimate.
Laying of Double circuit Line of 11 KV 185 SQ.MM XLPE cable in normal soil by digging of trench 2X3 Feet 80 Mtr Deep in G.I. Pipe 6" Dia including encluding required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks. Distance as per Estimate.
Laying of Double circuit Line of Railway Crossing Katghar by 11 KV 120 SQ.MM XLPE cable in normal soil by digging of trench 2X3 Feet 80 Mtr Deep in G.I. Pipe 6" Dia including encluding required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks. Distance as per Estimate.
Laying of Double circuit Line of Railway Crossing Katghar by 33 KV 300 SQ.MM XLPE cable in normal soil by digging of trench 2X3 Feet 80 Mtr Deep in G.I. Pipe 6" Dia including encluding required material as fine sand, 1st class bricks, stone slab. Inter axial spacing between the two cable should be in between 0.25 m to 0.40m. the two cables should be separated by a partition of single bricks. Distance as per Estimate.
Installation of O/D Cable Jointing Kit Suitable for 300 sq.mm. 11 KV XLPE Cable
Installation of O/D Cable Jointing Kit Suitable for 185 sq.mm. 11 KV XLPE Cable
Installation of O/D Cable Jointing Kit Suitable for 120sq.mm. 11 KV XLPE Cable
Cable jointing Kit for 300 sq.mm 33 KV XLPE Cable
M/s Sharda Electrical
M/S Shiv Traders
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .