GEMC-511687774612412
Awarded to ROCKWELL INDUSTRIAL PLANTS LIMITED
₹21.8 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Horizontal Rectangular Sterilizer (Double Sliding Doors) | ROCKWELL & Sambion 810 | - | 1 NOS | ₹21.8 L | 2,183,500 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹21.8 LQualified Make: Sambion - Kill Kinetics
Model: ROCKWELL & Sambion 810 B 24 N D S E PART 2 NEW DELHI DELHI 110049 | SOUTH DELHI | DELHI | 110049 | Make: Sambion - Kill Kinetics
Model: ROCKWELL & Sambion 810 | L1 | Qualified MSE | |
| 2 | L2₹54.2 L+₹32.4 L (148.2%)Qualified Make: Steris
Model: STERIS Sercon-300, 523 ASHOK VIHAR NORTH WEST DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110052 INDIA | NORTH DELHI | DELHI | 110052 | Make: Steris
Model: STERIS Sercon-300, 523 | L2 | Qualified MSE | |
| 3 | L3₹63.0 L+₹41.2 L (188.5%)Qualified Make: Steris
Model: STERIS Sercon-300, 523 6TH FLOOR K S CORPORATE TOWER PLOT NUMBER 24B FILM CITY SECTOR 16A NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | Make: Steris
Model: STERIS Sercon-300, 523 | L3 | Qualified MSE | |
| 4 | Disqualified Make: Accumax India
Model: AI-175 105 FIRST FLOOR VISHAL TOWER DISTRICT CENTRE JANAKPURI JANAKPURI WEST DELHI DELHI 110058 UDYAM DL 11 0022043 07ASXPS7874B1ZX R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110058 | Make: Accumax India
Model: AI-175 | - | Disqualified MSE | |
| 5 | Disqualified Make: METREX
Model: MA-10HR-500 PHASE 1 NEW DELHI DELHI 110064 | WEST DELHI | DELHI | 110064 | Make: METREX
Model: MA-10HR-500 | - | Disqualified MSE |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
13 Jul 2018, 11:00 amClosed
Steam Sterlizer Steam Sterlizer ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANGULAR HIGH SPEED STEAM STERILISER Pressure type
Chamber capacity: >450 to 500 litre
conforming to third party certification: USFDA or European CE. fully automatic steam jacketed suitable for operation on electricity
working temperature range 121 degree C - 134 degree C
facility to set working temperature and sterilisation cycle time. Should work with 3 phase 400/440 V 50 Hz AC supply
As per GeM Catalogue. Steam supply to Steriliser Built-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system)
it should work with 3 phase 400/440 V 50 Hz AC supply Direct Steam Operation from an external source
From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 1/5 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)]
Buil t-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system)
it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber
Jacket
Door
Door Ring and shall be made of SS 316 or SS 316L SS 304
SS 316 or SS 316L Type of control Automatic: MICROPROCESSOR CONTROLLED
WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) Manual through indt. switch based
Automatic: MICROPROCESSOR CONTROLLED
WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES - Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the No Yes
No 2/5 steriliser: Provision of Lock on Steriliser Chamber door: Automatic Lock Manual Lock
Automatic Lock
Manual and Automatic Locks
both Installation The site ready for installation equipped with water supply
electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. - Type of Door: Sliding type Sliding type
Hinged type
Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature
Cycle number
Batch Number
Time and date
Alarm indicator
Low water indicator Chamber Temperature
Low water indicator Print facility for record generation of dates
time
load
identification number and operating parameters (temperature and holding time etc): Yes
by an inbuilt printer unit Yes
port given to connect an external Printer Unit
Yes
by an inbuilt printer unit Warranty Period 3 3
5 No of Doors in Steriliser 2 1
2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is false 3/5 available (If Yes
to be furnished by Seller to Buyer on demand) for the offered product? Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: Touch screen interface Keyboard interface
Touch screen interface
NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis true Air removal from Sterilisation chamber
after loading the steriliser
by on for more pressure/vacuums pulsing for proper steam penetration YES - Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Not available Yes
with Microprocessor controlled
with Manually controlled Shredder unit
Not available Material: Shredder parts; SS 304 SS 304
SS 316 or SS 316L Power of Motor used for Shredding NA
no integrated Shredder unit offered Must be of >= 2 HP
>= 1000 RPM
220 V
50 HZ AC motor
and able to deal with shredding of bio medical waste land as per Steriliser capacity
NA
no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0
2 Long Handle: 1 0
1 Sterilisation Carriages 1 0
1
2 Pull out Trays/Tanks 2 0
2 Floor loading carts 2 0
2 Transfer carriages: 1 0
2 4/5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Kumar Gupta 486890
NEHRU SATABDI CHIKITSHALYA
SINGRAULI 1 60 Advisory Bank HDFC Bank EMD Percentage(%) 2.00 EMD Amount 127120 ePBG Advisory Bank State Bank of India ePBG Percentage(%) 2.00 Duration of ePBG required (Months). 60
282545
GEM/2018/B/40107
GeM Contract
Steam Sterlizer
GeM Contract
60 days
Madhya Pradesh; Singrauli
PRODUCT
Awarded to ROCKWELL INDUSTRIAL PLANTS LIMITED
₹21.8 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Horizontal Rectangular Sterilizer (Double Sliding Doors) | ROCKWELL & Sambion 810 | - | 1 NOS | ₹21.8 L | 2,183,500 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Steam Sterlizer Steam Sterlizer ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values Construction Type of Steriliser HORIZONTAL RECTANGULAR HIGH SPEED STEAM STERILISER Pressure type | - | - | - |
| Chamber capacity: >450 to 500 litre | - | - | - |
| conforming to third party certification: USFDA or European CE. fully automatic steam jacketed suitable for operation on electricity | - | - | - |
| working temperature range 121 degree C - 134 degree C | - | - | - |
| facility to set working temperature and sterilisation cycle time. Should work with 3 phase 400/440 V 50 Hz AC supply | - | - | - |
| As per GeM Catalogue. Steam supply to Steriliser Built-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system) | - | - | - |
| it should work with 3 phase 400/440 V 50 Hz AC supply Direct Steam Operation from an external source | - | - | - |
| From Built-in Steam Generator electrically heated using immersion heaters wired for operation on 3 phase 4 1/5 wire 400/440 V 50 Hz AC supply [with immersion heaters having mineral filled sheathed heating elements conforming to IS: 4159/2002 duly BIS marked and complying with safety requirements as per IS : 302-2-201(1992)] | - | - | - |
| Buil t-in electrically heated Steam Generator (made of SS 316 (AISI 316) with low water protection system) | - | - | - |
| it should work with 3 phase 400/440 V 50 Hz AC supply Material: Steriliser parts; Chamber | - | - | - |
| Jacket | - | - | - |
| Door | - | - | - |
| Door Ring and shall be made of SS 316 or SS 316L SS 304 | - | - | - |
| SS 316 or SS 316L Type of control Automatic: MICROPROCESSOR CONTROLLED | - | - | - |
| WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) Manual through indt. switch based | - | - | - |
| Automatic: MICROPROCESSOR CONTROLLED | - | - | - |
| WITH PRESELECTED STERILISATION PROGRAMS (variable programs customisable as per Buyer’s requirement to deal with sterilisation and drying of wrapped/unwrapped loads at 121 & 134 degree C ) CONSTRUCTION Instruction plate on Steam Steriliser advising user to use soft water for steam generation for long service life of Steam Steriliser YES - Whether a compatible water softener/reversed osmosis based system to feed water to the steam generator unit is to be supplied with the No Yes | - | - | - |
| No 2/5 steriliser: Provision of Lock on Steriliser Chamber door: Automatic Lock Manual Lock | - | - | - |
| Automatic Lock | - | - | - |
| Manual and Automatic Locks | - | - | - |
| both Installation The site ready for installation equipped with water supply | - | - | - |
| electric connection cabling and drainage outlet shall be provided by Buyer. The Seller shall be responsible to carry out for installation of the offered Steam Steriliser unit on turnkey basis i.e. Any civil work required for installation of the ordered equipment i.e. flooring tilling/plastering/Paint and/or wood work shall be Seller’s responsibility. The Seller shall also provide training to personnel of buyer. - Type of Door: Sliding type Sliding type | - | - | - |
| Hinged type | - | - | - |
| Radial Type Display facility for Sterilisation Cycle parameters Chamber Temperature | - | - | - |
| Cycle number | - | - | - |
| Batch Number | - | - | - |
| Time and date | - | - | - |
| Alarm indicator | - | - | - |
| Low water indicator Chamber Temperature | - | - | - |
| Low water indicator Print facility for record generation of dates | - | - | - |
| time | - | - | - |
| load | - | - | - |
| identification number and operating parameters (temperature and holding time etc): Yes | - | - | - |
| by an inbuilt printer unit Yes | - | - | - |
| port given to connect an external Printer Unit | - | - | - |
| Yes | - | - | - |
| by an inbuilt printer unit Warranty Period 3 3 | - | - | - |
| 5 No of Doors in Steriliser 2 1 | - | - | - |
| 2 Whether Type Test Certificate from a Govt/NABL/ILAC approved testing laboratory is false 3/5 available (If Yes | - | - | - |
| to be furnished by Seller to Buyer on demand) for the offered product? Type of user friendly Interface (for microprocessor controlled Sterilizer) to specify parameters for running Sterilization cycle: Touch screen interface Keyboard interface | - | - | - |
| Touch screen interface | - | - | - |
| NA Data Transfer facility through USB/RS232 port to computer/laptop on real time basis true Air removal from Sterilisation chamber | - | - | - |
| after loading the steriliser | - | - | - |
| by on for more pressure/vacuums pulsing for proper steam penetration YES - Integrated Shredder Facility Integrated Shredder (for shredding the load in Sterilisation chamber) Not available Yes | - | - | - |
| with Microprocessor controlled | - | - | - |
| with Manually controlled Shredder unit | - | - | - |
| Not available Material: Shredder parts; SS 304 SS 304 | - | - | - |
| SS 316 or SS 316L Power of Motor used for Shredding NA | - | - | - |
| no integrated Shredder unit offered Must be of >= 2 HP | - | - | - |
| >= 1000 RPM | - | - | - |
| 220 V | - | - | - |
| 50 HZ AC motor | - | - | - |
| and able to deal with shredding of bio medical waste land as per Steriliser capacity | - | - | - |
| NA | - | - | - |
| no integrated Shredder unit offered Accessories (made of SS 316) for loading/unloading and handling of Load Number of Rails: 2 0 | - | - | - |
| 2 Long Handle: 1 0 | - | - | - |
| 1 Sterilisation Carriages 1 0 | - | - | - |
| 1 | - | - | - |
| 2 Pull out Trays/Tanks 2 0 | - | - | - |
| 2 Floor loading carts 2 0 | - | - | - |
| 2 Transfer carriages: 1 0 | - | - | - |
| 2 4/5 * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Kumar Gupta 486890 | - | - | - |
| NEHRU SATABDI CHIKITSHALYA | - | - | - |
| SINGRAULI 1 60 Advisory Bank HDFC Bank EMD Percentage(%) 2.00 EMD Amount 127120 ePBG Advisory Bank State Bank of India ePBG Percentage(%) 2.00 Duration of ePBG required (Months). 60 | - | - | - |
₹1.3 L
25 Jan 2019
3 Jul 2018
contract_GEMC-511687774612412.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_282545.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .