Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹46.5 L+₹2.1 L (4.64%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWER | |
| 3 | L3₹47.2 L+₹2.8 L (6.33%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWER | |
| 4 | L4₹49.9 L+₹5.5 L (12.4%)Rejected-Finance 518 2 SAMYAPUR ROAD RAJIV COLONY BALLABGARH 121004 | BALLABGARH | FARIDABAD | HARYANA | 121004 | L4 | Rejected-Finance HIGHEST | |
| 5 | Not Admitted-Fee/PreQual/Technical CHAUDHARY APARTMENT NEAR HARYANA PUBLIC SCHOOL BALI NAGAR PALWAL 2021R1085 | 2021085 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
22 Jul 2021, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
XEN
M C HODAL
Construction of 14 No. Rain water harvesting System in the various Places in M.C Hodal Area
2021_HRY_179881_1
HOD00620210630112214
Open Tender
Civil Works
Fixed-rate
120 days
M C HODAL
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,500
Yes
₹75,000
Yes
1 Dec 2021
15 Jul 2021
22 Jul 2021
15 Jul 2021
22 Jul 2021
15 Jul 2021
60 days
Amount
CIVIL WORK
-Brick work with common burnt clay non-modular bricks of class designation 7.5 in foundation and plinth in: 7.21.1 Cement mortar 1:4 (1 cement: 4 coarse sand) new hsr 7.21.1
-Boring for hand-pump in clay fitting strainer and pipe. Above 75mm dia bore but not exceeding 100mm.18.50.2.2 Exceeding 15 m but up to 30 m.
-Cement Concrete 1:8:16 with stone aggregate 40 mm size in foundation and plinth (new hsr 10.100.2)
-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 4.14.1 All kinds of soil.
-Providing, lowering, laying, cutting (cut surface to be uniformly finished), jointing with rubber rings marked with IS : 5382 and testing of SPIGOT AND SOCKETTED RCC, NP2 MARKED WITH IS : 458-1988 and specials into trenches for all depths including carriage, loading, unloading, stacking, handling, re-handling etc. complete is all respects to the satisfaction to the Engineer - in -charge. 20.62.1 200 mm i/d new hsr 20.62.1
-:4: 8 ( 1 Cement : 4 coarse sand (zone-Ill) : 8 graded cum stone aggregate 40 mm nominal size) (new hsr 6.1.6)
-providing and placing in horizontal layers filtering media screened washed and cleaned as described below - second layer- Course sand screened cleaned and washed and graded from 3 mm to 6 mm
-providing and placing in horizontal layers filtering media screened washed and cleaned as described below -Fourth layer Bajri (coursed) screened and washed graded from 20 mm to 25 mm (from Ghaggar or approved equivalent quarry)
-Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement.Cold twisted bars new hsr 6.33.3
-12 mm cement plaster of mix 1:4 new hsr 11.5.3
-Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed-150 mm diameter (new hsr 9.57.3)
-providing and placing in horizontal layers filtering media screened washed and cleaned as described below - 20.52.1 Top Layer: 20.52.2 Fine sand screened, cleaned and washed and graded (effective size 0.2 to 0.4 mm with uniformity coefficient 2.0 to 3.0) from Ghaggar or other approved source1
-providing and placing in horizontal layers filtering media screened washed and cleaned as described below -Bottom layer Broken stone, screened, washed and graded from 50 mm to cum 75 mm (from Ghaggar or approved equivalent quarry)
-Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: Pipes, cables etc. exceeding 80 mm metre dia. but not exceeding 300 mm dia
-Providing & fixing steel bar embedded plastic steps of size 263mm x each 143 165mm of orange colour, confirming to specification in pump chambers, manholes etc., having minimum 3mm thick polypropylene polymer confirming to is:10910 encapsulated on 12mm dia ribbed steel bars per IS : 1786. The rate include cost of setting the same to correct lines and levels duly embedded in 1 :2:4 cement concrete including carriage, loading, uploading, stacking, handling, re-handling etc., complete in all respect to the satisfaction of Engineer-in-charge new hsr 21.28
-providing and placing in horizontal layers filtering media screened washed and cleaned as described below -Third layer Bajri (coursed) screened and washed graded from 6 mm to 20 mm
-Providing and fixing SFRC MANHOLE COVERS AND FRAMES MARKED WITH IS: 12592 including setting the same to correct lines and levels in 1 :3 cement sand mortar over manhole including carriage loading unloading stacking handling re-handling etc. complete in all respects to the satisfaction to the Engineer-in-charge. 21.93.1 Type:- Extra Heavy Duty Set (EHD-35) 560MM Clear Opening
-Reinforced cement concrete work in beams, suspended floors, cum roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor four level, excluding the cost of centering, shuttering, finishing and reinforcement with 1: 1.5:3 (1 cement : 1.5 coarse sand(zone-111) : 3 graded stone aggregate 20 mm nominal size). new hsr 6.16
THE TYAGI BABA COOPERATIVE LABOUR AND CONSTRCUTION SOCIETY
THE BANSWA CO OPERATIVE LC SOCIETY LTD
Dadhwal Contractors
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .