Superintending Engineer , 765/400kV SDC.
office of SE 11th Floor, Shakti Bhawan Extension, 14- Ashok Marg, Lucknow-226001.
Construction of 02 Nos. 220kV AIS Line Bays and Extension Work of Main Bus-01 and Bus-02 at 400kV AIS Substation Manth, Mathura
2026_PTRCL_1210112_1
ESD-8/244
Open Tender
Electrical Works
Turn-key
Lucknow
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,950
UPPTCL A/c no 628105038318 (IFSC -ICIC0006281)
₹4.0 L
19 Nov 2026
19 Nov 2026
18 Dec 2026
19 Nov 2026
17 Dec 2026
19 Nov 2026
180 days
Unit Frieght & Insurance, loading and unloading charges
Unit Frieght & Insurance, loading and unloading charges
Unit Frieght & Insurance, loading and unloading charges
Part A (Elecrical)
245KV Circuit Breaker
245 KV Isolators (double break with 2E/S)
245 KV Isolators (double break with 1E/S)
245 KV Tandom Isolators (double break)
245 KV Current Transformer (polymer)
245KV CT Junction Box
245 KV CVT
245KV CVT Junction Box
216 KV Surge Arrester
245 KV Bus Post Insulators
245KV Line Protection Panel(SAS)
CB Panel with auto reclose (SAS based)
Interfacing of BCUs with existing SAS & SCADA system
Augmentation of existing Bus Bar Protection Scheme
Optical fiber required for SAS
Armoured Control Cable
2CX2.5Sqmm
3CX2.5Sqmm
5CX2.5Sqmm
7CX2.5Sqmm
10CX2.5Sqmm
14CX2.5Sqmm
19CX2.5Sqmm
Armoured Power cables
4CX6Sqmm
4CX16Sqmm
3.5CX35Sqmm
3.5CX70Sqmm
Bay Marshalling Boxes
Clamps, Fittings, Springs & Disc Insulator
Al pipe (4" IPS)
GI strip for Earthing 75*12
ERW pipe type Aux Structure
40 mm dia MS round for earthing
MS Electrode of 3 meter length
Fire fighting Device
Control card
Zone Card
Heat detector
Smoke detector
Electronic Hooter
repairing/rectification charge
Fire Extinquisher Cylinder CO2(4.5Kg)
Fire Extinquisher Cylinder CO2(9.0Kg)
Fire Extinquisher Cylinder CO2(22.5Kg)
Fire Extinquisher Cylinder dry chemical(4.5Kg)
Fire Extinquisher Cylinder Mechanical Foam (50Kg)
Fire Bucket
Fire Bucket Stand
Carrier Intertripping Device
2 Ton split AC with voltage stabiliser
Testing Equipment
Primary injection kit
5KV Digital Insulation tester
Universal Relay Testing Kit
Luminaries
Sublighting panel type SLP
LED Luminaries 250W
LED Luminaries 150W
Lighting system for kiosk
Moose conductor
Extension of 220KV Main-1 and Main-2 BUS and transfer bus
GI Structure
Moose conductor
Tension string and hardware fitting with turnbuckle for quad moose
Tension string and hardware fitting without turnbuckle for quad moose
Quad moose spacer
Tension string and hardware fitting with turnbuckle for twin moose
Tension string and hardware fitting without turnbuckle for twin moose
Twin moose spacer moose spacer
Item Description
Part A (Elecrical)
Armoured Control Cable
2CX2.5Sqmm
3CX2.5Sqmm
5CX2.5Sqmm
7CX2.5Sqmm
10CX2.5Sqmm
14CX2.5Sqmm
19CX2.5Sqmm
Armoured Power cables
4CX6Sqmm
4CX16Sqmm
3.5CX35Sqmm
3.5CX70Sqmm
Al pipe (4" IPS)
GI strip for Earthing 75*12
40 mm dia MS round for earthing
Fire fighting Device
Control card
Zone Card
Heat detector
Smoke detector
Electronic Hooter
repairing/rectification charge
Fire Extinquisher Cylinder CO2(4.5Kg)
Fire Extinquisher Cylinder CO2(9.0Kg)
Fire Extinquisher Cylinder CO2(22.5Kg)
Fire Extinquisher Cylinder dry chemical(4.5Kg)
Fire Extinquisher Cylinder Mechanical Foam (50Kg)
Fire Bucket
Fire Bucket Stand
Carrier Intertripping Device
Testing Equipment
Primary injection kit
5KV Digital Insulation tester
Universal Relay Testing Kit
Luminaries
Sublighting panel type SLP
LED Luminaries 250W
LED Luminaries 150W
Lighting system for kiosk
Moose conductor
Extension of 220KV Main-1 and Main-2 BUS and transfer bus
GI Structure
Moose conductor
Tension string and hardware fitting with turnbuckle for quad moose
Tension string and hardware fitting without turnbuckle for quad moose
Quad moose spacer
Tension string and hardware fitting with turnbuckle for twin moose
Tension string and hardware fitting without turnbuckle for twin moose
Twin moose spacer moose spacer
EQUIPMENT / ITEM (Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications)
Unit Pkg, Fwdg, Charges
Item Description
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m (DSR.2.8.1).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR. 4.1.2)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :C C 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR. 4.1.8)
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns: CC (DSR.4.3.1)
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform ( DSR 5.9.3 )
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers ( DSR 5.9.5 )
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR. 5.1.2)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (CSI No. 4.2.2)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).(DSR. 5.3 )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.(DSR 5.22.6)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:(Cement mortar 1:4 (1 cement : 4 coarse sand)) (DSR.6.1.1)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)(DSR.6.4.1)
Arranging and spreding 75 mm thick broken grit 20 mm (Granite stone) uniform for turfing over 100mm thick base course of C.C. In 1:4:8 (1cement:4coarse sand: 8, 40mm stone ballast) top finish by brooming of cement mortar 1:4(1cement: 4 Coarse sand) including supply of all materials, labour and tools and plants etc. required for proper completion. ( NSI No. 5.31 )
Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work(NSI No. 9.12)
Fixing and grouting 28 mm and above dia bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) . (NSI No. 9.13)
Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. (NSI No. 9.14)
Fixing and grouting 25 mm and below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . (NSI No. 9.15)
Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only). (NSI No. 9.31)
Fixing of template in position level and alignment for grouting of Anchor bolt in Auxiliary Structure (labour rate only). (NSI No. 9.32)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works . (CSI No. 10.25.2)
Pebble dash plaster upto 10 m height above ground level with a mixture of washed pebble or crushed stone 6 mm to 12.5 mm nominal size, dashed over and including fresh plaster in two layers under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.. (CSI NO. 13.20)
Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm) (CSI No. 13.44.1)
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (CSI No. 13.80)
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats (CSI No. 13.83.2)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :Powder coated aluminium (minimum thickness of powder coating 50 micron) ( DSR 21.1.1.2 )
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)( DSR 21.1.1.2 )
Providing (12x15) mm section groove in plaster including all material, labour and T&P etc. required for proper completion of the work.(NSI No. 11.16)
Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. (NSI No. 11.18)
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water abCSIption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (CSI No. 11.47.2)
12 mm cement plaster of mix :1:4 (1 cement: 4 Coarse sand)(DSR.13.4.1)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately).(SOR 16.75 )
Providing and Laying finished gans saw 60-75 thick cut block of biyana (Hindon) Hard mine stone cut and chisel line and level with dressed/finished edge of required shape and size including royality and cartiage upto site.(Extra item approved by SE civil Agra wide OM No.943/ECTC/A/Extra item dated.22.10.19)
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :) For 400 mm dia piles.(DSR. 20.3.2)
Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) FOR 400mm (DSR. 20.4.2)
Description
Total Price for Supply of Equipments and Material [Schedule-Q1 ]
Total Handling, Erection, Testing & Commissioning Charges [Schedule-Q2]
Total Price for Supply of Mandatory Spares [Schedule-Q3 ]
Total Charges for Civil works including supply of materials [Schedule-Q4]
Summary of Total Price (With GST)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
BOQ.xlsx
Additional Documents • 0.04 MB
vol2.pdf
Tender Documents • 11.91 MB
volumeN.pdf
Tender Documents • 1.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .