| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-Finance 55 VIBEKANANDA SARANI BYE LANE UDAY RAJPUR MADHYAMGRAM KOLKATA 700129 | MADHYAMGRAM | 24 PARAGANAS NORTH | WEST BENGAL | 700129 | ₹12.2 L | L1 | Accepted-Finance all documents are in order |
| 2 | L2₹12.3 LRejected-Finance | ₹12.3 L | L2 | Rejected-Finance all documents are not in order |
| 3 | L3₹12.5 LRejected-Finance | ₹12.5 L | L3 | Rejected-Finance all documents are not in order |
| 4 | Rejected-Technical | - | - | Rejected-Technical due to non submission of original documents |
| 5 | Rejected-Technical | - | - | Rejected-Technical due to non submission of original documents |
Tender Value
₹12.3 L
EMD Value
₹24,538
Closing Date
10 Feb 2026, 1:00 pmClosed
Executive_Engineer_Kolkata_North_Division_PWD
O/O_Executive_Engineer_Kolkata_North_Division_PWD 166_10 BT Road Dunlop Kolkata_108
Special roof treatment works of the G-Type Building along with special repairs of G5 and G3 quarters at Central Dairy Belgachia during the year 2025 2026
2026_WBPWD_991561_3
WBPWD/EE/KND/NIeT-27/2025-2026
Open Tender
CIVIL WORKS
30 days
Central Dairy
Please refer Tender documents.
4 documents required · 4 mandatory
₹24,538
Yes
27 Mar 2026
21 Jan 2026
12 Feb 2026
28 Jan 2026
10 Feb 2026
28 Jan 2026
Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge.
Cleaning the exposed corroded Reinforcement as well as worn out concrete by sand blasting with air compressor including all materials, hire charges of machineries and labour etc. all complete as per technical specification and direction of the Engineer-in-Charge.
Applying epoxy based reactive joining agent for joining the old concrete with fresh concrete to be applied within manufacturer's specified time as per manufacturers specification. (0.4 Kg / m² of concrete surface).
Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment]
Removing corroded worn out portion of reinforcement (when the area of bar is damaged by more than 25%) by cutting and replacing the same by a new plain round bar of requisite diameter by binding with required lap / welding with old bar, including cost of reinforcement, complete in all respect including removing unserviceable materials from site as per direction of the Engineer - in - charge. Note : Payment on weight (Kg.) of new reinforcement.
Removal of defective concrete, cleaning the surface thoroughly, applying the shotcrete mixture mechanically with compressed air under pressure, comprising of cement, sand, coarse aggregates, water and quick setting compound in the proportion as per clause 2807.1., sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012 respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than 2000 kg/cum, strength not less than 25 MPa and workmanship conforming to clause 2807.6. (40 mm average thickness.)
Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy.
Sealing of crack / porous concrete with Epoxy Grout by injection through nipples complete as per clause 2803.1.
Welding in M.S. structural work with gas or electric: (a) Tack weld
Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, ground floor
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in Ground floor.
Stripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed.
(a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification [Cement to be supplied by the Department]
Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P. M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge. b) 25 mm thick
A) Stitching crack in brick wall by carefully cutting out face brick 125 mm. deep into the wall, cleaning the gap and filling up the same with precast cement concrete block carefully set in cement mortar (1:3) including mending good damages and finishing the surface to match with adjacent areas complete as per direction. (ii) With reinforced cement concrete blocks (1:1½:3) with stone chips and nominal reinforcement. (b) Block size 250 x 125 x 150 mm. (Cement-2.5 Kg/No.)
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor). Inside of Building (i) With 1:6 cement mortar (b) 20 mm thick plaster (Inside Wall) In First Floor -
(i) With 1:6 cement mortar (b) 20 mm thick plaster (Inside Wall) In Second Floor -
(ii) With 1:4 cement mortar (c) 10 mm thick plaster (In Ceiling, Chajja & Beam) In First Floor -
(ii) With 1:4 cement mortar (c) 10 mm thick plaster (In Ceiling, Chajja & Beam) In Second Floor -
(i) With 1:6 cement mortar (c) 15 mm thick plaster (Outside Wall) Second Floor
Labour for Chipping of concrete surface before taking up Plastering work.
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary (Ground floor). Inside of Building (i) With 1:6 cement mortar (a) 25 mm thick plaster In Ground Floor -
Application of priming coat for standard bituminous waterproofing treatment over flat roof with Bitumen primer of approved brand fufilling the provision of I.S. 1346 - 1991 & 3384 - 1986 applied @ 0.27 Liters /Sq.m. over clean and prepared roof surface complete as per satisfaction of the Engineer - in - Charge
Supplying & laying 3mm thick pre-fabricated plastomeric water proofing membrane conforming to EN 12311-1 & ASTMD 5147, manufactured with atactic poly propylene (APP) modified premium grade asphalt, specially reinforced with non-woven polyester core with polyester reinforcement @160 gms per sqm & both faces covered with thermo-fusible polyethylene film /MineraL on top face over a coat of primer @ 0.40 lit/ sqm of manufacturer's specification on smooth,clean dry surface prepared wherever required.Lap joint shall be provided of 75 mm in longitudinal & 100 mm in transverse direction and fused using LPG/ Propane torch employing extra care ensuring full bondage, complete removal of entrapped air and sealing edges into grooves in appropriate manner as per direction of Engineer -in-charge all complete including materials,labour and applicable taxes.
(B) Painting with superior quality aluminium paint of approved make and brand including smoothening surface by sand papering etc. on steel surface. (b) Two coats
Preparation of drainage spout on roof for bituminous waterproofing treatment after required grading and shaping of the under bed with Cement Concrete (1:2:4) or Cement Mortar (1:4) as directed, Chamfering and moulding the parapet wall to form a bell mouth entry, if required and providing full course treatment with bituminous felt to facilitate quick and smooth drainage of watwr into the down pipes complete including cost of all materials and labour according to satisfaction of the Engineer - in - Charge. All floor-
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia.
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
Reinforcement for reinforced concrete works in all sort of structure including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction. II.JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSL
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) (When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht. shall be allowed under 12 (e) for every 4 m or part thereof) (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side of granite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m] (b) Area of each Granite slab above 1.00 Square meter.
Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damaes complete. (Concrete and brick work for mending damage will be paid separately) (a) Upto area 2.5 Sq.m
Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (d) Sal : Local. In First Floor-
In Second Floor-
Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (a) 35mm thick shutters (single leaf) In First Floor-
In Second Floor-
Supplying fitting, fixing decorative lamination conforming to IS: 2046 : 1995 as per approved make, brand, finish and thickness with fitting, fixing the same on Particle/MDF / Ply Boards with recommended / approved adhesive with proper clipping the sides for better attachment as per direction of Engineer- charge.The rate includes the cost of labour, adhesive and all incidental charges thereof. Glossy/Matt/Suede excluding surface texture or metallic lustre (i) Thickness of laminate 1.5mm
Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings. (iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm. (b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. In First Floor-
In Second Floor-
Supplying, fitting & fixing factory made foam PVC (density shall not be less than600 kg/cum) door frame (finished weight of 2.73 kg/mtr.) of size 100mm X 45mm made off with 5mm thick extruded foam PVC sheet, mitre cut at junction of horizontal and vertical member and joined them by heat welding. Entire door frame profiles to be reinforced with steel primer coated 19 SWG 40mm X 20mm M.S. tube. An additional 5mm thick PVC sheet with desired colour/shade to be provided at the exposed surface and three nos 5mm thick PVC sheet to be provided as gap insert. The door frame to be fixed with wall by using 8mm dia. and 100mm long strainless steel screws and PVC fasteners. A minimum of 4 nos. screws to be provided for each vertical member & 2 nos. for horizontal member all complete as per direction of Engineer-in-Charge. (b) Pre-laminated Colour.
Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in Charge. In First Floor
In Second floor.
Renewing worn out putty of glass (a) Panes not exceeding 0.2 Sq.m In Ground Floor
Reparing collapsible gate by cutting out all rivets as necessary reassambling all members including welding pieces of channels, sraightening bent bars and rivetting with new rivets and fitting in position and painting two coats. In Ground floor
Renewing bottom rail or top runners of collapsible gate including mending good all damages.
Easing and oiling, cleaning collapsible gate and repairing to locking arrangements.
Repairing steel shutter with new rivets including taking out and refixing, adjusting, welding, cleaning cutting holes, mending good damage to match with the existing one.
Easing, oiling and adjusting the steel shutters including scraping all members and fitting so as to make the shutters easily operable (no extra payment will be made for taking out and fixing glass, if necessary). and windows as directed including painting complete.
Supplying best Indian sheet glass panes set in putty (as per I.S specification) and fitted and fixed with teak wood beads and nails complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick
Extra for fixing glass panes in steel window
Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with10cm. dia bamboo as main post sattherate of 1 metre centre to centre and 7.5cm. dia bamboo ties @0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-in-charge.(Up to 2nd Floor)
Labour rate for shifting scaffolding
Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete (1:2:4) as per direction. (Cost of concrete will be paid separately) (c) 40mm X 6mm, 125mm Length
Taking out old brass hinges and fitting, fixing the same with new brass screws. (c) 100mm. Long butt hinge.
Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (Add Extra 30% for Oxidised Fittings) (viii) 100mm. X 75mm. X 3.50mm.
Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete: (a) With continuous plate base (Hexagonal/ Round rod). (iv) 125 mm grip x 10 mm dia rod.
(i) Door stopper.(Brass)
Iron socket bolt of approved quality fitted and fixed complete. (d) 225mm long x 10mm dia bolt.
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (a) 200mm long
(a) Supplying 'Godrej' mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
ii) Godrej Hydraulic door closer fitted and fixed complete. (a) Heavy type
(a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. First Floor-
a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. Second Floor-
Supplying, fitting, fixing C.I Grating (Heavy type). (b) Above 100 mm and upto 150 mm Square or round
Supplying, fitting & fixing Step edging made of anodised Aluminium Alloy Extrusion (weight @ 0.494 Kg per Mtr.) Conforming to IS: 732-1983 and IS: 1285-1975, fixed to the steps by strainless steel screws driven by electric drill as per specification & direction of Engineer-in-charge.
Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
Supplying maruti lock (100mm)
Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. b) 'U' shaped EPDM gasket for frames.
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm) In First Floor
M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. (length of straight not less than 230 mm) In Second Floor
Supplying, fitting and fixing glass reinforced polyester translucent fiber glass sheet to match with GCI Corrugation as per IS: 12866 - 1989 in roof fitted and fixed with 10 mm dia "J" or "L" hook, bolts and nuts, limpet and bitumen washers and putty with 150mm end lap and one corrugation minimum side lap complete. b) 2.0mm +/- 0.2 mm thick sheet.(3.25Kg/Sq.m) iv) Special coloured textured tissue In First Floor
In Second Floor
Removing loose scales, blisters etc. from old painted surface and thoroughly smoothening the surface to make the same suitable for receiving fresh coat of paint. Ground Floor-
Applying Interior grade Acrylic Primer of approved quality and brandon plastered or cencrete surface old or new surface to receiveDistemper/ Acrylic emulsion paint including scraping and preparingthe surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (b) Two coats. i) Water based interior grade Acrylic Primer First Floor-
Second Floor-
Applying Acrylic Emulsion Paint of approved make and brand on wall sand ceiling including sand papering in intermediate coats including putty(to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standard Quality In First Floor
In Second Floor
(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. First & Second Floor Collapsible Gate-
(b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. Ground Floor
A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) On steel or other metal surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
(A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface : With other than hi-gloss of approved quality- (iv) Two coats (with any shade except white)
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: (ii) 110 mm. Dia.
B) UPVC Fittings: c) Bend 87.5 degree (ii) 110 mm. Dia.
Supplying, fitting and fixing Bib Cock or Stop Cock. (a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing Bib Cock or Stop Cock. (d) (i) Chromium plated Angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing Bib Cock or Stop Cock. (e) PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15mm.
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
Supplying, fitting and fixing 10 litre P.V.C. low-down Cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
Dismantling and taking out lead / polythene waste pipe and refixing the same after removing chokage including necessary bendings/ offsets and straightening and replacement of damaged parts, if any.
Supplying, fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. (iii) 900 mm long
Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (v) 900 mm long
Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). (ix) 15 mm dia
Dismantling and refixing shower rose after cleaning.
b) Chromium plated Rose shower with revolving joint and 150 mm long shower arm (Equivalent to Code No. 5489 & Model - Florentine of Jaquar or similar brand).
Supplying, fitting and fixing Soap holder. (a) PTMT(Prayag or equivalent)
Supplying, fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. (i) Polythene Flush Pipe
Supplying, fitting and fixing Towel Rail with two brackets. (b) Aluminium, (iii) 25 mm dia. and 750 mm long
Supplying, fitting & fixing Aluminium domical grating. (ii) 125 mm dia
Dismantling E.P. or Anglo-Indian W.C.
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With 'P' trap
Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (iv) Bestolite (solid type) white
Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. (ii) 470 mm X 280 mm X 340 mm
Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (b) Sink with drain board 1050 mm X 450 mm X 180 mm
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). (A) PVC Pipes. (Dia) 25 mm
(A) PVC Pipes. (Dia) 15 mm
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (ii) Double Socketed 3 Meter Length. (b) 110 mm
(B) Fittings (x) Bend 87.5º (b) 110 mm
Add: SGST 9 % + CGST 9% = 18 %
Labour Wellfare Cess 1%
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.35 MB
AnnexureXnew.pdf
Additional Documents • 0.01 MB
BOQ_2425262.xls
BOQ • 0.52 MB
2911iiason01122019.pdf
Tender Documents • 0.54 MB
Download all tender documents and submit your bid