Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 4264 GALI SHAHTARA AJMERI GATE DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹37,000
Closing Date
26 Jul 2021, 11:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (EnM) WnS S-III
D-Block, Saket. Opp. PVR cinema. New Delhi-110017
Improvement of C-6 BPS by addition of higher pump set of Capacity 100 HP at C-6 BPS Vasant Kunj under Mehrauli Constituency AC - 45.
2021_DJB_205423_1
NIT No-10 / EE (EnM) WnS S-III
Open Tender
Electrical Works
Works
30 days
D-Block, Saket. Opp. PVR cinema. New Delhi-110017
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹37,000
Yes
24 Aug 2021
6 Jul 2021
26 Jul 2021
6 Jul 2021
26 Jul 2021
6 Jul 2021
120 days
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection .The each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipments of the panel will be as per standard given in relevant IS. The bus bar Size: 30 mm X 10 mm (suitable for 200 Amp.) of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminium. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire. Size of Panel : 900 mm x 375 mm x 1600 mm Having following components of approved make.
MCCB 415V, 3 Pole, 3 phase 50 KA 50Hz, 200 Amp with spreader & handle. Make:- L&T/Siemens
MCB Single pole 6 Amp. Make:- L&T/Havells
MCB Triple pole 32 Amp. Make :-L&T/Havells
Copper wire flexible 70 sq mm single core Make: Finolex/Havells
Power capacitors 415V unit of 35 Kvar Make:- Havells /L&T(247/-P/KVAR)
Over load relay 90-150 Amp Make:-L&T/Siemens
Over load relay 6-10 Amp Make:- L&T/Siemens
Digital Amp. Meter:-Make AE/L&T
Digital Volt Meter 0-500V .Make:- AE/L&T
Motor protection Relay Make:- L&T/Siemens
Power contactor 220V 3 phase 225 Amp. Make:- L&T/Siemens
Power contactor 220V 3 phase 140 Amp. Make:-L&T/Siemens
Power contactor 220V 3 phase 25 Amp. Make:-L&T/Siemens
Star delta timer on delay. make:- L&T/Siemens
Indicating lights LED type RYB & On/OFF Make:-L&T/Havells
Current Transformer 200/5 & 30/5. Make:- AE /Advance
Fixing of the above components in panel enclosure with terminal blocks, channels, ferrules, thimble, support insulator on bus bar required hard wares, control wiring in 1.5 sq mm single copper wire complete in all respect.
Testing & commissioning of panel, as per required parameters with relevant IS . Testing of the panel prior to switching.
Supply of Horizontal split casing pump with impeller and neck ring (SS-410), shaft and sleeve (SS- 410) and casing (CI) in fitted condition with suitable bearing along with IE2 rating TEFC , 3 phase AC Induction Motor 415 volt, 50 Hz with IP-55 Protection . The pump and motor coupled on M.S Base frame with coupling and coupling Guard. Specification of pump with (Duties of pump) - Head- 35 mtrs, Discharge- 486 m3/hr. Size- Suction/Delivery-(250mmX200mm). Motor Ratings- 75KW/100 HP, RPM- 1480 , Efficiency- 80 % , Make of Pump M&P/ Kirloskar / DJB approved Make of motor- CG/BBL/Kirloskar/ DJB approved
Supply of Vacuum Pump Model DV - 40 Size 40 mm x 40 mm coupled with 5HP, 3 phase Induction motor, 1450 RPM 415 volt,50 Hz. mounted on MS Fabricated Base frame coupled and Guard. For the purpose of charging of pump set for negative suction. Make:-Kirloskar/M&P
Providing and lying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering – All work up to plinth level: 1:2:4. ( 1 cement :2 coarse sand : 4 grade stone Volume of foundation 100 HP Electric pump set= 1 ( LxBxH) A- (1.8 m x 0.75 m x 1.2 m)= 1.62 cum B-Vacuum pump set = 1.00 m x 0.6m x 1.2 m)= 0.72cum Total = 1.62+0.72= 2.34 cum 5.1.3 DSR 2018
Centering and shuttering including strutting, propping etc. And removal of form for: For foundation, footing, bases of columns etc. for mass concrete. 5.9.1 DSR 2018
Steel reinforcement for RCC work for including straitening, cutting, bending, placing in position in binding all complete up to plinth level. Cold twisting bars 5.22.3 DSR 2018
Providing of M.S Pipe size of 250 mm dia , thickness 6 mm , 2 Mtrs long, Medium class duly welded with both side MS Flange of 20 mm thickness as per site requirement .
Providing of M.S Pipe size of 200 mm dia thickness 6 mm, 2 Mtrs long Medium class duly welded with both side MS Flange of 20 mm thickness as per site requirement .
Providing of MS Gap Piece of Size 250 mm dia thickness 6 mm an approx. 61 cm. Medium class duly welded with both side MS Flange of 20 mm thickness as per site requirement .
Providing of MS Gap Piece of Size 200 mm dia thickness 6mm an approx. 61 cm. Medium class duly welded with both side MS Flange of 20 mm thickness as per site requirement .
Providing of 250 mm dia. Non rising spindle CI D/F sluice valve as per IS 14846 PN 1.0. Make – Kirloskar / IVC.
Providing of 200 mm dia. Non rising spindle CI D/F sluice valve as per IS 14846 PN 1.0. Make – Kirloskar / IVC.
Providing of 200 mm dia Non return Valve CI D/F as per IS 14846 PN 1.0 Make – Kirloskar / IVC
Providing of Rubber insulation sheet, size 1.5 mm thickness. Make :- Jyoti/National
Providing of MS foundation Bolts of sizes 20 mm x 450 mm ISI mark
Providing of MS nut bolt with washer as per site requirement ISI mark
Providing and fixing GI pipes ( medium) with fittings for external work including trenching and refilling Etc. External work 32 mm dia nominal bore 18.12.4 DSR 2018
Providing and fixing GI union in GI pipe including cutting and threading the pipe and making long screw etc complete (New work) 32 mm nominal bore 18.46.4 DSR 2018
Providing and fixing Gun metal valve with C.I wheel of approved quality (Screwed end) 32 mm nominal Bore 18.17.2 DSR 2018
Fixing of M S base frame on the RCC foundation and tightening with foundation Nut Bolts. Fixing of Electric pump set on the MS base frame, make proper alignment and tightening the same with the help of required arrangements.
Making suction connection by fixing of sluice valve, gap pieces and flange as per site requirement. & Making delivery connection by fixing of sluice valve, NRV, gap piece, M S Pipe and flanges as per site requirement
Loading, unloading by crane or heavy labour and cartage up to site i/c Motor p/set, vacuum P/set, Sluice valve NRV, Pipe etc. It also i/c the all job work which required to commissioning the BPS at per site requirement.
Testing and commissioning of complete system at no load and full load with all the required tests.
Goodwill Enterprises
Shakti Trading Co.
Sarvottam Sales and Services
Raj Engineering Co.
paramount systems
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .