| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAdmitted-Finance | ₹38.7 L | L1 | Admitted-Finance |
| 2 | L2₹39.9 L+₹1.2 L (3.03%)Admitted-Finance 301 CHAMUNDA ENCLAVE PLOT NO 89 AIROLI SECTOR 8A NAVI MUMBAI 400 708 | THANE | MAHARASHTRA | 400708 | ₹39.9 L+₹1.2 L (3.03%) | L2 | Admitted-Finance |
| 3 | L3₹40.7 L+₹2.0 L (5.16%)Admitted-Finance | ₹40.7 L+₹2.0 L (5.16%) | L3 | Admitted-Finance |
| 4 | L4₹40.9 L+₹2.2 L (5.68%)Admitted-Finance | ₹40.9 L+₹2.2 L (5.68%) | L4 | Admitted-Finance |
| 5 | L5₹41.0 L+₹2.3 L (5.92%)Admitted-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | ₹41.0 L+₹2.3 L (5.92%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Nexus Infratech L6 | Sagar Electricals L5 | DARSHAN CONSTRUCTION Co. L3 | S K ENTERPRISES L2 | SHREE ARIHANT CONSTRUCTION L4 | INDIA ENTERPRISES L1 | K A ELECTRIC CO L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge | 180 | RM | 142 ₹25,560 Lowest | 222 ₹39,960 | 255 ₹45,900 | 270 ₹48,600 | 235 ₹42,300 | 150 ₹27,000 | 290 ₹52,200 |
| 2.00 | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and ,connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge | 130 | RM | 85 ₹11,050 | 60 ₹7,800 | 100 ₹13,000 | 180 ₹23,400 | 120 ₹15,600 | 55 ₹7,150 Lowest | 145 ₹18,850 |
| 3.00 | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 140 | RM | 198 ₹27,720 | 240 ₹33,600 | 333 ₹46,620 | 360 ₹50,400 | 245 ₹34,300 | 175 ₹24,500 Lowest | 354 ₹49,560 |
| 4.00 | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 120 | RM | 110 ₹13,200 | 90 ₹10,800 | 99 ₹11,880 | 270 ₹32,400 | 105 ₹12,600 | 77 ₹9,240 Lowest | 195 ₹23,400 |
| 5.00 | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and , connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | 236 ₹23,600 Lowest | 253 ₹25,300 | 400 ₹40,000 | 450 ₹45,000 | 260 ₹26,000 | 280 ₹28,000 | 410 ₹41,000 |
| 6.00 | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | 166 ₹16,600 | 105 ₹10,500 | 99 ₹9,900 Lowest | 270 ₹27,000 | 122 ₹12,200 | 117 ₹11,700 | 200 ₹20,000 |
| 7.00 | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | 396 ₹39,600 | 303 ₹30,300 | 500 ₹50,000 | 630 ₹63,000 | 305 ₹30,500 | 270 ₹27,000 Lowest | 612 ₹61,200 |
| 8.00 | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc. complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | 197 ₹19,700 | 150 ₹15,000 Lowest | 150 ₹15,000 Lowest | 360 ₹36,000 | 170 ₹17,000 | 150 ₹15,000 Lowest | 245 ₹24,500 |
| 9.00 | M&L for Submain wiring with two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20/25 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | 519 ₹51,900 | 402 ₹40,200 | 677 ₹67,700 | 720 ₹72,000 | 410 ₹41,000 | 400 ₹40,000 Lowest | 690 ₹69,000 |
| 10.00 | M&L for Submain wiring with Two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / wallscomplete all as specified and directed by Engr-in-Charge | 100 | RM | 238 ₹23,800 | 240 ₹24,000 | 300 ₹30,000 | 450 ₹45,000 | 265 ₹26,500 | 180 ₹18,000 Lowest | 285 ₹28,500 |
Tender Value
₹45.0 L
EMD Value
₹89,980
Closing Date
5 Sept 2026, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
COMPREHENSIVE MAINT OF BR AND E M WORKS LIKE REPAIR REPLACEMENT OF INTERNAL WIRING DBS RCBO AND OTHER MISC WORKS FOR EXPLOSIVE AND NON-EXPLOSIVE AREA OF NAD AT NAVAL STATION KARANJA
2026_MES_767323_2
8323/E8
Open Tender
Civil Works
Item Rate
330 days
GE NW KARANJA
Class D and above and category b (i)
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹89,980
Yes
8 Sept 2026
13 Aug 2026
7 Sept 2026
13 Aug 2026
5 Sept 2026
22 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge | 180 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 1.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 1.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and ,connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls, complete all as specified and directed by Engr-in-Charge | 130 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 140 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 2.5 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 2.5 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 120 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and , connecting to earth dolly - including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 4 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including in existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 4 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and ,connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 6 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc. complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and, connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
| - | M&L for Submain wiring with two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through and including stove steel enameled conduit 20/25 mm dia with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / walls complete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
| - | M&L for Submain wiring with Two core 1100 volts 10 sqmm FRLSH size PVC insulated PVC unsheathed stranded copper conductor using color code drawn through existing stove steel enameled conduit with accessories like flame proof bend, flame proof juntion box etc complete all as specified in and including 6 sqmm PVC insulated PVC unsheathed FRLSH copper conductor in cable for continuous earth continuty conductor by using green colour to common earth and connecting to earth point and connecting to earth dolly including taking down of old unserviceable sub main wiring from ceiling / wallscomplete all as specified and directed by Engr-in-Charge | 100 | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
8323TenderDocs.pdf
Tender Documents • 1.24 MB
BOQ_878707.xls
BOQ • 0.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .