| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹45.8 L+₹1.9 L (4.29%)Rejected-Finance 17 1A BALLYGUNGE CIRCULAR ROAD KOLKATA 700 019 | KOLKATA | WEST BENGAL | 700019 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹45.9 L+₹1.9 L (4.43%)Rejected-Finance 186 B DIAMOND HARBOUR ROAD KOLKATA 700 060 | KOLKATA | WEST BENGAL | 700060 | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹46.2 L+₹2.3 L (5.13%)Rejected-Finance | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹46.5 L+₹2.5 L (5.75%)Rejected-Finance | L5 | Rejected-Finance other than lowest |
Tender Value
₹39.2 L
EMD Value
₹78,400
Closing Date
16 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO BLDG NO. O-1/1 INSIDE FORT WILLIAM UNDER GE (FW) KOLKATA
2022_MES_505942_2
8825/E8
Open Tender
Civil Works
Item Rate
180 days
GE(FW) Kolkata
Ref tender documents
6 documents required · 6 mandatory
₹500
GE(FW) Kolkata
₹78,400
24 Mar 2022
9 Mar 2022
17 Mar 2022
9 Mar 2022
16 Mar 2022
9 Mar 2022
60 days
Amount
SCHEDULE 'A' PART-I (B/R WORKS) Dismantling of plain corrugated steel sheeting any gauge, thickness, including nainital or similar pattern roof covering & removing off the site complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per Item No. 02 above but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
Taking down cement plaster or cement lime plaster on brick or stone walls etc including rakingout joints, hacking for keys, scrubbing down with water etc and removal of debris outside MOD land complete all as specified and directed.
M & L for 20 mm thick plastering in two layers, 10 mm + 10 mm in cement mortar 1:4, top layer of 10 mm thickness mixed with with water proofing compound (@ 200 ml per bag of cement or as per manufacturer's instructions) on brick/stone walls or concrete surfaces finished even and fair (upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separetly as "Supply only".
M&L for rendering 15 mm thick built in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even & smooth (without using extra cement) complete all as specified and directed.
Supply only liquid water proofing compound all as specified and as directed.
Demolition of Brick Work built in Cement Mortar including all Quoins, Arches, Pillars, etc. of any description and removal of debris outside MOD land complete all as specified and directed.
M&L for cutting openings, through brick wall, built in cement mortar, for doors, windows and other openings or enlarging existing openings, converting window into door openings, etc or cutting out defective brickwork for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus bricks, hardcore, rubbish etc from site complete all as specified and directed.
Forming jambs etc to openings, including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, in cement mortar 1:4 complete all as specified and directed.
making good under cills or over arches, lintels and bressumers including all pinning when necessary, in cement mortar 1:4 complete all as specified and directed.
[NOTE FOR ITEM NO 09-11: Measurement for openings shall be carried out as per preambles give on Ser page No. 69 of SSR 2020, Part-II (Rates)]
M&L for brick work using fly-ash bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
-ditto- but re-using serviceable bricks obtained from demolition
M&L in brick work using fly-ash bricks straight or curved on plan to any radius in half brick wall, built in cement mortar 1:4 all as specified and directed
M&L for applying one coat of white wash to old decorated surfaces of wall including preparation of surfaces complete all as specified and as directed.
M&L applying one coat of cement base paint on walls, cornices incl preparation of old plastered or unplastered surfaces of wall complete all as specified and directed.
M&L for applying two coats of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) including preparation of newly plastered surfaces of walls of any description, over 10cm width or girth not otherwise described complete all as specified and directed.
M&L for complete removal of existing treatment on walls, of any description, over 10cm width or girth not otherwise described for and applying two coats of exterior acrylic emulsion weather proof paint over a coat of suitable exterior primer (as per manufacturer's instructions) complete all as specified and directed.
M&L for 2 coats of acrylic distemper over a coat of alkali resistant primer applied over and including 1.5 mm thick wall putty on new internal plastered wall surfaces after preparation of surfaces complete all as specified and as directed.
M&L for complete removal of existing treatment of old wall surface and applying two coats of oil bound distemper over a coat of alkali resistant primer applied over and including 1.5 mm thick wall care putty complete all as specified and directed.
M&L for preparing new surface of wood or wood based material of any description and in any position not otherwise described for, exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for applying two coats of synthetic enamel paint over a coat of Red oxide, zinc chrome primer to new steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed by Engineer-in-Charge.
M&L for applying one coat of synthetic enamel paint to old painted wood or wood based surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed.
M&L for applying one coat of synthetic enamel paint to old painted steel surfaces of any description over 10 cm width or girth including preparation of surfaces all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for and removal of debris outside MOD land complete all as specified and directed.
M&L for RCC 1:1½:3 type A1 (using 20 mm graded aggregate)as in slabs supported on walls, beams and columns in floors, roofs, drain, ducts, canopies etc. complete complete all as specified and directed. (NOTE: Reinforcement shall be measured and paid seperately)
M&L for providing precast cement concrete (1:2:4) type B1 using 20 mm graded aggregates set in cement mortar 1:4 as in landings, cover slabs (for manhole etc.) chullah hoods, chajjas, water troughs, shelves and similar articles with plain faces complete all as specified and directed. (NOTE: Reinforcement shall be measured and paid seperately)
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L mild steel bands and straps support or stays holdfast and similar articles conforming complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B1 usi ng 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like includinguding weathering, slightly rounded or chamfered angles and throating incl formwork complete all as specified and directed.
M&L in repair False ceiling with 'E' board "Classic", reinforced, designer series, board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on aluminium snap grid to support the boards/files with aluminium anodised main 'T' section 36mm x 25mm x 1.40mm cross tee 23.50mm x 23.50mm x 1.40mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides, fixed to ceiling with hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including dismantling of existing ceiling complete all as specified and as directed. (NOTE: Quoted rate shall be deemed to be inclusive of the cost of ceiling board)
S&F in repair 'E' board "Classic", reinforced, designer series, ceiling board with HPSC of size 600 mm x 600 mm x 4 mm thick fixed on existing snap grid system complete all as specified and as directed.
S&F galvanised steel tubing, 50 mm bore, light grade, with all fittings, fixed in ceilings for hanging false ceiling including cutting holes into or through brick walls of 150 mm depth, built in cement mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregates) as required for superficial area exc 150sqcm but not exc 400 sqcm complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
M & L Vitrified coloured (light shade) double charged ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade laid over and including screed bed 15mm thick in cement mortar 1:4 complete all as specified and directed.
-ditto- but as in skirting over 10 mm thick screed in cement mortar 1:3 complete
M&L Non Skid joint free coloured tiles 7-8mm thick area of each tiles exc 0.06 sqm but n. exc 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and incl 15mm thick screed bedding in cement mortar 1:6 complete all as a specified and as directed
M&L coloured glazed ceramic tiles in vertical surfaces 450X300X7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match, fixed over and incl 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed.
M&L granite (of any type) work, 18-20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, urinal partition and like in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and making moulds on edges laid over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick, laid over and including 15mm thick screed bed in cement mortar (1:4) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and directed.
M&L for laying and fixing Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in cement mortar 1:4 and jointed etc complete all as specified and directed.
M&L for machine cut kota stone slab, 18-20 mm thick, in shelf of almirah, jointed with grey cement slurry, fixed on dry with brick wall and match with existing surface including rubbing and polishing complete all as specified and as directed.
M&L 25 mm thick pre polished coloured chequred tiles of size 300mm X 300mm, jointed & pointed in neat cement slurry with white or coloured to match the shade of tiles, laid over & incl 15 mm thick screed bed in cement mortar 1:6 complete all as specified & directed.
M & L for heavy duty coloured ceramic floor tiles of size 300 x 300x 10 mm thick, suitable for high traffic external tiles, anti skid, scratch resistance and neutral to UV rays and acid alkali resistance as in floor including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : ENDURA or equivalent model in other makes listed in the tender)
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed. (NOTE: Quoted rates shall be deemed to include for cutting to dead length where required, notching, drilling, fitting, riveting and/or welding or connecting with bolts and nuts (including rivets or bolts and nuts), providing and fitting angle cleats, fish plates, gusset plates etc., also for wedging, plumbing, truing up and fixing complete)
-ditto- but using old serviceable iron members including necessary cutting to size, welding etc
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
S&F in repairs 35mm thick precast cement concreate (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) louvers and jallies including all moulding, set in cement mortar 1:4 fixed complete all as specified and directed.
M&L for Plain Cement Concrete (1:4:8) type D2 using 40mm graded stone aggregate as in footpath, sub base of floor etc completed all as specified and directed.
M&L 75 mm thick PCC 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/Paving etc, finished even and smooth using extra cement complete all as specified and directed.
M&L for providing Plain Cement Concrete (1:3:6) type C1 using 20mm graded stone aggregate as in surface channel and drain completed all as specified and directed.
M & L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc completed all as specified and directed.
Taking down wooden chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each complete all as specified and directed.
Taking down wooden chowkhat or frames with shutters (without taking off shutters from the frame) area n.exc. 1.5 Sqm each complete all as specified and directed.
Taking down shutters of any description not exc 1.00 sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.00 sqm but n.exc 2.00 Sqm each and re-fixing in the same opening after necessary repair like easing, etc complete all as specified and directed.
Taking down wooden chowkhat or frames with shutters (without taking off shutters from the frame) area exc 1.5 Sqm and n.exc.4.00 Sqm each and re-fixing on other openings complete all as specified and directed.
S&F for 2nd class hardwood, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints complete all as directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter(two panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35mm thick Factory made 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to receive glass, gauge etc.(with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F 30mm thick Factory made 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to receive glass, gauge etc.(with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a) complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 100 mm x 45mm made out of 5mm plain colour PVC sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 guage throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
S&F PVC solid door frame of size 50 x 47 mm made out of 5 mmthick prelaminated single side PVC sheet reinforced with MS square tube complete all as specified and as directed.
S&F for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
S&F 30 mm thick factory made both side prelaminated solid panel PVC door shutter consisting of frame made out of MS tube of 19 gauge thickness and size of 19mm X 19mm for stiles, top and bottom rails, treated with a coat of metal primer, MS frame covered with heat moulded prelaminated PVC 'C' channel for stiles and both side prelaminated PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; stiles and rails feathered at edges, panelling of both side prelaminated PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading, and joined together with solvent cement and fixing in frame complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium section weighing 0.55 Kg/metre including necessary jointing cleats, glazing clips, rubber packing, anodised aluminum snap beading, screws, anodised aluminum fittings such as suitable 150 mm long peg stays (01 No), hinges type B-21 100 mm long (02 Nos), suitable handle-01No each shutter etc as per manufactures instruction complete all as specified and directed. (NOTE: Quoted rate is deemed to be inclusive of the cost of include for anodised aluminium hard ware as indicated, glazing clips, rubber packing, anodised aluminium snap on beading for fixing glass panes in frames, handle etc as described in item. Sheet glass shall be measured seperately)
S&F in repair powder coated aluminium wndow grill of size 100 mm X 100 mm having section width 6 mm and 3 mm thickness, fixed on aluminium section weighing not less than 0.55 kg/sqm including necessary jointing, fitting etc all as per manufacturer's instruction complete all as specified and directed.
S&F floor door stopper of brass body and tounge, anodised, with hard drawn steel spring, fixed in floor. 150mm overall length of cover plate complete all as a specified and as directed
Supply & fixing 100mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
Supply & fixing 75mm stainless steel butt hinges (medium weight) cold rolled complete all as specified and directed.
Supply & fixing extruded aluminium alloy handle fabricated type anodised 125 mm size (ISI marked) complete all as specified and directed.
S&F 150mm long aluminium anodised handles (fabricated type) ISI marked complete all as specified and directed.
Supply & fixing 150 mm size aluminium anodised barrel tower bolts of extruded section (ISI marked) complete all as specified and directed.
S&F 200mm long aluminium anodised tower bolts extruded section, ISI marked complete all as specified and directed.
S&F 300mm long aluminium anodised sliding bolt with hasp, staple (bolt type) and fixing clips or sheets cast of extruded section and fixing bolts and sliding bolts of extruded section ISI marked complete all as specified and directed.
S&F stainless steel wire cloth, 0.63 mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
. - ditto - all as per item No. 84 here-in-before, but fixed in repair.
S&F 4 mm thick plain sheet glass ordinary quality and glazing in square n.exc 0.50 Sqm in each pane complete all as specified and directed.
-ditto- but with 4 mm thick frosted glass
S&F 4.8 mm thick plain sheet glass ordinary quality and glazing in square n.exc 0.50 Sqm in each pane complete all as specified and directed.
M&L for replacement of decayed timber with new well seasoned 2nd class hardwood, wrought, of approved species (including piecing, scarfing etc, of old & new timbers if required), duly fixed in position without damaging the roof slab including necessary scaffolding and treating the new wooden surfaces with and including two coats of synthetic enamel paint over a coat of wood primer complete all as specified and directed.
M&L for polyvinyl chloride (PVC) door frame of size 18x50mm with a wall thickness of 18mm made out of extended 18mm PVC sheet and jointed with suitable cement solvent adhesive screw. The section are to be cut with size 18mmx50mm at the height according to the site. The door frame shall be fixed to the wall using 75mm long MS screw through the frame by using PVC fasteners. A minimum 3 Nos screw to be provided for each vertical membrane minimum 2 Nos for horizontal member etc. complete all as directed.
M&L for 18mm thick solid PVC door shutter made out of 18mm celuka printed and PVC coated sheet which is cut according to the size of the almira shutter, kitchen cabinet drawer etc. Providing and groove to be made on the one edge so that overlapping could be done for double leaf for door shutter the fixing is to be done by the 15mm MS powder coated screw to be frame with the 75mm long aluminum hinges (2 Nos), 125mm long aluminum handle (1nos for each shutter and 75mm long aluminum hasp staple fixed with screw for door shutter complete all as per direction of Engr-in-Charge.
M&L for stainless steel powder coated tray of various sizes for drawers to keep kitchen utensils complete all as specified and directed.
S&F in repair vitreous china wall mounted coupled closet (Pedestal pattern), white, including low level vitreous china valveless syphonic action type flushing cistern with inlet ball valve float, push button, flush pipe incl bracket, P/S trap, PVC white soft close seat cover and connecting fittings complete all as specified and directed. (Make :CERA, Model : CLAIR / PARRYWARE, Model: CASCADE NXT / JAQUAR, Model: FLORENTINE / HINDWARE, Model: CONSTELLATION)
S&F in repair vitreous china, white, counter top wash hand basin, including providing 32 mm dia chromium plated waste coupling and waste pipe and making all necessary connections complete all as specified and directed. (Make : Hindware, Cat No: 10038 / CERA, Cat No: S2030101 / Parryware, Cat No: C0431 or similar model in JAQUAR)
S&F in repair 15mm bore chromium plated central hole basin mixer (premium quality) without popup waste system with 450mm long copper pipe and brass nut, complete all as specified and directed. (MAKE : JAQUAR, Cat No : CON-167KNB / PARRYWARE, Cat No: G1414A1 / CERA, Model: OCEAN / PRAYAG, Cat No: 9250 / HINDWARE, Model: CONTESSA PLUS)
S&F in repair 6mm thick bevelled edge mirror of size as required fixed on 6mm thick acrylic PVC sheet complete all as specified and directed.
S&F in repair Chromium plated brass Bib cock with wall flange, fancy type, long body, fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: CON-107KN/ PARRYWARE, Cat No: G1405A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9208 /HINDWARE, Cat No: F330041)
Supply and fixing gun metal gate or globe valve, with iron wheel head, screwed both ends for iron pipe and fixed for 20 mm bore pipe complete all as specified and directed.
S&F in repair chromium plated brass over head shower rose with arm (premium quality), with 3 flow, fixed to 15mm bore of iron pipe complete all as specified and directed. (Make : CERA, Cat No: F7040103 (for arm) & F7020305 (for shower) / PARRYWARE, Cat No: T9802A1 (for arm) & T9986A1 (for shower)/ HINDWARE, Cat No: F160051 / PRAYAG, Cat No: BOS-86)
S&F in repair Chromium plated brass Angular stop cock, fancy type, concealed type with wall flange fixed to 15 mm bore of Iron pipe complete all as specified and directed. (Make : JAQUAR, Cat No: CON-59KN / PARRYWARE, Cat No: G1453A1 / CERA, Model: OCEAN / PRAYAG, Cat No: 9210 / HINDWARE, Cat No: F330043)
S&F in repairs Low density polyethylene pipe connection, comprising of 15 mm dia 450 mm long having PTMT union at each end of connection to each of pillar tap/cistern/stop cock/urinal etc. at one end, stop cock at other end complete all as specified and directed. (MAKE : PRAYAG, Cat No. 323 / POLYTUF, Cat No. 4003 or equivalent model in SHAKTI / JEXON)
-ditto- all as per Item No. 79 here in before but 600mm long. (MAKE : PRAYAG, Cat No. 324 / POLYTUF, Cat No. 4004-D / SHAKTI, Cat No: SB 1324-D or equivalent model in JEXON)
S&F in repairs stainless steel round grating 102mm dia complete all as specified and directed. (Make : PRAYAG, Cat No: FT-62 or equivalent make as approved by GE)
S&F in repair Chromium plated brass Wall mixer, concealed type incl concealed body, with both overhead and telephone shower arrangement, fixed with 15 mm bore Iron pipe including taking down existing mixer complete all as specified and directed. (Make : Jaquar, Cat No : CON-281KN / PARRYWARE, Cat No: G1417A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9280 / HINDWARE, Cat No: F200022) NOTE: Telephone shower shall be measured and paid seperately.
S&F fancy type chromium plated telephonic hand shower with flexible tube and hook screwed for iron pipe including frame complete all as specified and directed. (Make : PARRYWARE, Cat No: T9983A1/ PRAYAG, cat No: BHS-91S / CERA, Cat No: F7030502 / HINDWARE, Cat No: F160053 or equivalent model in JAQUAR)
S&F in repair corner glass shelf 300 mm with brass brackets, as in repair complete all as specified and directed. (Make: PRAYAG, Cat No: BEA-44 / JAQUAR, Cat No: ACN-1173 / PARRYWARE, Cat No: T6010A1 / CERA, Cat No: F5005102/ ESS ESS, Cat No: AC-207A)
S&F in repair 15mm bore chromium plated two way bib cock with flange, fancy type complete all as specified and as directed. (Make : JAQUAR, Cat No: CON-041KN/ PARRYWARE, Cat No: G1434A1 / CERA, Model : OCEAN / PRAYAG, Cat No: 9212/HINDWARE, CAT No: F330004CP)
S&F in repair chromium plated Hand shower (health faucet), brass body with 1.2 metre long flexible tube in chrome finish with wall hook complete all as specified and directed. (MAKE : JAQUAR, Cat No : ALD-573/ PARRYWARE, Cat No : T9941A1 /CERA, Cat No: F8030401AB / HINDWARE, Cat No: F160002 / PRAYAG, Cat No: 452)
S&F 75 mm dia PVC floor trap with grating including jointing with solvent cement complete all as specified and directed
S&F in repair powder coated steel peg stay having 05 Nos stay fixed to walls complete all as specified and directed.
S&F decorative type stainless steel powder coated curtain rod, 25 mm dia, double curtain fitting type, fixed with end brackets complete all as specified and directed. (NOTE: Brackets will be measured and paid seperately)
S&F decorative type brass brackets for curtain rod, suitable for double curtain complete all as specified and directed.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick in kitchen with plug washers, waste coupling, PVC waste pipe and fixing cantilever brackets connecting union to pipe, overall size of sink 914 mm x 460 mm and bowl size 405 mm x 354 mm x 203 mm complete including taking down existing sink complete all as specified and directed. (MAKE : PRAYAG, Cat No. 1239-D or equivalent model in NIRALI / DIAMOND / ANJALI / JAYNA / BLUE STAR / CERA / PARRYWARE)
S&F in repairs Stainless steel kitchen rack of size 31" x 24" x 10" fixed in wall with screws and washer complete all as specified. (Make- Prayag , Model No- P-340 or equivalent model in SUYOG / BLUE STAR / ANUPAM INDUSTRIES)
Supply, hoisting and fixing rotational moulded polyethylene water storage tank (cylindrical vertical type with closed top) of capacity 1000 Litres, multi-layered (ISI marked), with GI tank nipple & cover, hoisted and fixed in position all as specified in SSR Part-I incl dismantling of existing unsv tank complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with HDPE float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed. (MAKE : PRAYAG, Cat No. B-152 or equivalent model in JEXON / POLYTUF / SHAKTI)
S&F in repair Cast iron (sand cast) soil, waste and vent pipes 100 mm bore of any length with or without ears with cement joints all as specified laid in trenches or in floors complete all as specified and directed.
-ditto- but pipes fixed on walls with ms clamps
S&F in repair Cast iron (sand cast) soil, waste and vent pipes 150 mm bore of any length with or without ears with cement joints, fixed on walls with ms clamps complete all as specified and directed.
S&F CI bends for 100mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
S&F CI bends for 150 mm pipe (any radius) diminishing piece or tapers (large bore measured) complete all as specified and directed.
S&F 100 mm bore cast iron (sand cast) bends with access door (any radius), diminishing pieces or tapers (larger bore to be measured) complete all as specified and as directed by the Engineer-in-Charge.
S&F CI (sand cast) Branch pieces, single (any radius, equal or unequal) for 100 mm bore pipe for any building height complete all as specified and directed.
Excavation in trenches n exc 1.50 m wide and n exc 1.50m depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes etc not exc 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in soft/loose Soil, complete all as Specified and as directed.
Removing excavated materials not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point complete all as Specified and as directed.
Returning filling in incl spreading , levelling , watering and well ramming in layers not exc 25 cm as in soft/ loose Soil, complete all as Specified and as directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) 150 mm set in cement mortar complete all as specified and as directed.
Supply and laying 150 mm bore reinforced concrete pipe of Class NP-2, laid and jointed with jute & cement mortar 1:2, complete with collars all specified and as directed.
M&L concrete bed to drain pipe including packing under and haunching against the side of drain pipe after laid and tested in PCC 1:3:6 type C2 for 150 mm bore pipes complete all as specified and directed.
M&L for cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth in brick walls complete all as specified and directed.
M&L in repair for Expanded metal, cut to length, bent to shape required and tying with and including anealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight n exc 4 Kg per sqm complete .
Taking up or down steel water tubing 15 mm bore incl connections etc complete all as specified and directed.
All as per item No. 132 here-in-before but 20 mm bore
All as per item No. 132 here-in-before but 25 mm bore
Relaying/Re-fixing Galvanised Steel Tubing and Connections in New or Old Position (Serviceable Pipes and Fittings obtained from taking down item) after Cleaning both Inner and Outer Surfaces of Pipes by using of Wire Brush, fixed to walls and ceilings or laid in floors complete all as specified and as directed for the follwing size of pipes :-
15mm bore
20mm bore
25mm bore
S&F tubes 15mm bore "medium grade" galvanised with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed.
All as per item No. 136 here-in-before but 20 mm bore
All as per item No. 136 here-in-before but 25 mm bore
SCH 'A' PART-II (INT ELECTRIFICATION WORKS) Taking down copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed.
M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan point or bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage)
All as per item No-138 but one light controlled by two 2-way switches (For Modular Switch- concealed type)
All as per item No 138 here-in-before but for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 16 here-in-before but for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
All as per item No 138 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling, for mounting MODULAR TYPE switches
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 6 A, 1 module
MODULAR SWITCH, 5/6 AMPS, 1 MODULE, TWO WAY
S & F Modular Switch 2 way 6 A, 1 module
MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY
S & F Modular Switch 1 way 16 A, 1 module
MODULAR SOCKET, 6 AMPS, 2 MODULE
S & F Modular Socket 6 A, 2/3 pin combined 2 module
MODULAR SOCKET, 16 AMPS, 2 MODULE
S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module
MODULAR FAN REGULATOR
S & F Modular Fan step regulator, 120 watt, 2 module
MODULAR BELL PUSH
S & F Modular Bell push 6A, 1 module
MOTOR STARTER SWITCH
S & F 25 Amps motor starter switch, modular type
CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE
S&F new Call bell, musical type
CEILING ROSE, THREE TERMINALS, 240 VOLTS
S&F new Ceiling rose, surface type
LAMP HOLDER, PVC/POLYCARBONATE BODY
S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls
MODULAR TYPE COVER PLATE WITH FRAME
S&F Modular White cover plate with frame 3 module
S&F Modular White cover plate with frame 4 module
S&F Modular White cover plate with frame 6 module
S&F Modular White cover plate with frame 8 module
S&F Modular White cover plate with frame 12 module
MODULAR TYPE METAL FLUSH BOX
S&F Modular White cover plate with frame 3 module
S & F Modular type Metal Flush box 4 module
S & F Modular type Metal Flush box 6 module
S & F Modular type Metal Flush box 8 module
S & F Modular type Metal Flush box 12 module
S&F in repair Skirting light with LED - 230 V - 3 module with necessary electrical connection with suitable size copper wire complete all as specified and directed. (Make : ANCHOR (WOODS), Cat No: 60253 / LEGRAND, Cat No; 6730 36 or equivalent model in HONEYWELL MK / ABB / SCHNEIDER / CRABTREE)
Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed.
S&F TPN DB, IP 43 protection, double door (premium range), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH)
S&F Double Door, Sheet Metal Enclosure for DBs (premium range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D)
NOTE FOR ITEM NO. 158 to 159 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer.
S&F MCB (premium range), 'C' series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium range), 'C' series, SPN, 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F MCB (premium range), 'C' series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER)
S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connected complete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate)
Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed.
M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
All as per Srl. Item No. 165 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit)
S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation
S&F recess mounted LED luminaire, of size 600 mm x 600 mm, in powder coated CRCA housing , having glare free diffuser, operating voltage 180-270V, with constant current electronic driver complete with all accessories with and including 35/36 Watt LED and including all accessories, mounting frame etc and connecting up with three core flexible copper conductor wire of adequate size complete all as specified and directed and complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection: IP20
S&F LED Bldg Security Light fitting 30 W, in pressure die cast aluminium housing with PMMA lens and toughened glass/PC cover having TOP opening seperate driver compartmnent, with integrated constant current electronic driver, incl providing new GI pipe bracket as per existing size including necessary electrical connection with stuiable size copper wire complete all as specified and directed and complying with the following specifications:-. (a) minimum efficacy 110 lumen/watt (b) CRI not less than 70, (c) THD < 30% (c) having in built short circuit & surge protection upto 5 kV (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation (f) Weather protection grade: IP66
Supply, installation, testing and commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 ltrs capacity with BEE 5 star rating (min) and ABS body, glass lined/titanium enamel coated inner tank incl fixing arrangement with providing incl suitable capacity flexible cable 3 core with 3 pin plug of 16 amp complete all as specified and directed. (Make: RACOLD, Model - CDR DLX / AO SMITH, Model- HSE-VAS / Havells, Model: Monza Dx / BAJAJ, Model: CALDIA)
Supply and Hanging, ceiling fan, with brushless DC motor, 1200 mm sweep without remote, down rod, canopy, fan blades and accessories and connecting up including provision of PVC insulated, sheathed round flexible wire with multi stranded copper conductor of size 1.0 Sq mm, 3 core, 1100 Volts grade, from ceiling rose/ connector to fan including dismantling existing fan complete all as specified and directed. (MAKE : USHA, Model: TECHNOAIR / CROMPTON GREAVES, Model : ENERGION HS / ORIENT, Model: ECOTECH or equivalent model in BAJAJ / HAVELLS) NOTE: Old fan shall be deposited by contractor in MES storeyard
S&F exhaust fan 300 mm sweep, 900 RPM, heavy duty, AC Single Phase 230/240 volts, metal body, louvers complete with all accessories and connecting up with and including twin core twisted flexible copper conductor cable of size 1.5 sqmm (nominal area) from ceiling rose to fan complete all as spcified and directed. (MAKE : HAVELLS, Model: Turbojet SP / CROMPTON, Model: EXHD300-6-1 / USHA, Model: Turbo Heavy Duty or equivalent model in BAJAJ / ORIENT) NOTE: Old fan, if any taken down, shall be deposited by contractor in MES storeyard.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia (upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed.
M A ENTERPRISES
MS JYOTI INDUSTRIES
DILIP CONSTRUCTION
JOY-EN-JOY
ARATI TRADING CO
MARUTI ENTERPRISES
M/S L.R.ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .