GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2021_MES_417967_1
8400-580/E8
Open Tender
Civil Works - Water Works
Works
180 days
PANAGARH
Class D, a (ii)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹88,000
Yes
29 Jul 2021
2 Feb 2021
3 Mar 2021
2 Feb 2021
1 Mar 2021
15 Feb 2021
60 days
Amount
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in soft/lose soil for taking out pipe & laying of pipe & getting out for diverting of CI pipe line complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering & well ramming in layers n. exc 25 cm thick complete all as specified and directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Taking up CI/DI water main (incl all fitting) with spigot & socket ends and lead joints incl burning out & recovering lead from pipe of 100 mm bore for relaying / rerouting of serviceable pipe after cleaning complete all as specified and directed.
All as per item No 4.00 mentioned here-in- above but 150 mm bore complete all as specified and directed.
All as per item No 4.00 mentioned here-in- above but 200 mm bore complete all as specified and directed.
All as per item No 4.00 mentioned here-in- above but 250 mm bore complete all as specified and directed.
Relaying of DI/CI/GI pipe 100 mm bore in trenches/ over the masonry pillars after cleaning thoroughly including fittings complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but 150 mm bore complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but 200 mm bore complete all as specified and directed.
All as per item No 8.00 mentioned here-in-above but 250 mm bore.
S&F DI pipe of 100 mm bore with spigot and socket end rubber gas cate joint(titon) centrifugally cast class k-7 conforming to IS 8329-2000 laid in trenches/ on surface/ over masonry pillar and connection to old or new position complete all as directed. Cost of joint included in the qoted rate complete all as specified and directed.
All as per item No 12.00 mentioned here-in-above but 150 mm bore complete all as specified and directed.
All as per item No 12.00 mentioned here-in-above but 200 mm bore complete all as specified and directed.
All as per item No 12.00 mentioned here-in-above but 250 mm bore complete all as specified and directed.
Taking up or down 50 mm bore steel tubing and connection including cleaning for relaying or removal to store from trenches/wall surfaces complete all as specified and directed.
All as per item No 16.00 mentioned here-in-above but bore of Pipe 40 mm complete all as specified and directed.
All as per item No 16.00 mentioned here-in-above but bore of Pipe 25 mm complete all as specified and directed
All as per item No 16.00 mentioned here-in-above but bore of Pipe 20 mm complete all as specified and directed
Relaying/re-fixing old 50 mm bore GI tubing or in floor/pillar/wall in new or old position complete all as specified and directed.
All as per item No 20.00 mentioned here-in-above but bore of Pipe 40 mm complete all as specified and directed.
All as per item No 20.00 mentioned here-in-above but bore of Pipe 25 mm complete all as specified and directed.
All as per item No 20.00 mentioned here-in-above but bore of Pipe 20 mm complete all as specified and directed.
S&F 50 mm bore GI tubing medium grade in Trenches/ Floor/Pillar and connection in old or news position including fitting like socket/Union/Tee/Reducer Nipple etc complete required will be supplied by Contractor rate for the same is included in the item rate quoted complete all as specified and directed.
All as per item No 24.00 mentioned here-in-above but bore 40 mm complete all as specified and directed.
All as per item No 24.00 mentioned here-in-above but bore 25 mm complete all as specified and directed.
All as per item No 24.00 mentioned here-in-above but bore 20 mm complete all as specified and directed.
M&L for DI bend any type, radius and angles, tappers and type (straight, bend, increasing, decreasing, or double socket etc. Tee pipes single branch Y junction, double branch cross (all socket, socket and Spigot or flanged ends) collors, caps and plugs for the Pipes socket and Spigot. All socket and flanged upto bore of 250 mm complete all as specified and directed. (Lead/gasket for fitting shall be measured and paid separately)
M&L for rubber gasket joint in repair for 100 mm bore CI/DI Pipe with Spigot & Socket ends after connection of old and new position complete all as specified and directed.
All as per item No 29.00 mentioned here-in-above but size 150 mm bore complete all as specified and directed.
All as per item No 29.00 mentioned here-in-above but size 200 mm bore complete all as specified and directed.
All as per item No 29.00 mentioned here-in-above but size 250 mm bore complete all as specified and directed.
Taking out of existing US CI Sluice valve of any size, any type upto 250mm bore from 80 mm bore complete all as directed.
S&F 80 mm bore CI Sluice valve PN – 1.0 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as specified and directed.
All as per item No 34.00 mentioned here-in-above item but 100 mm bore complete all as specified and directed.
All as per item No 34.00 mentioned here-in-above item but 150 mm bore complete all as specified and directed.
All as per item No 34.00 mentioned here-in-above item but 200 mm bore complete all as specified and directed.
All as per item No 34.00 mentioned here-in-above item but 250 mm bore complete all as specified and directed.
Refixing of Sluice valve 200 mm bore after taking out, refacing of valve spindle,re grinding, including taking part and reassembling, as per existing and complete scaling and proper functioning at site including replacement of nuts, bolts, washers and gasket as required at site complete all as specified and directed.
All as per item No 39.00 mentioned here-in-above item but size 150 mm bore complete all as specified and directed.
All as per item No 39.00 mentioned here-in-before item but size 100 mm bore complete all as specified and directed.
M&L for 50 mm bore gate valve gum metal class-II screwed down high pressure with clutch handle screwed both ends for Iron pipe including taking out of old unserviceable gate valve complete all as specified and directed.
All as per item No 42.00 mentioned here-in-above item but size 40 mm bore complete all as specified and directed.
All as per item No 42.00 mentioned here-in-above item but size 25 mm bore complete all as specified and directed.
All as per item No 42.00 mentioned here-in-above item but size 20 mm bore complete all as specified and directed.
S&F for straight plain brass ferrules (or connecting screws) screwed bolt ends of 20 mm bore Pipe complete all as specified and directed.
All as per item No 46.00 mentioned here-in-above item but size 25 mm bore complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundation of pillar complete all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in coping on brick machinary on of pillar and like complete all as specified and directed.
M&L for brick work in cement motar (1:6) as brick pillar for supporting of CI/DI pipe line complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:6) on brick surface fair and even complete all as specified and directed
M&L for brick massonary valve pit with brick in CM (1:6) with 100mm thick PCC work 1:3:6 type C2 from fundation over 75mm thick hard core, sub class B brick full brick thick wall, 15mm thick internal and external plaster at bottom of the pit of size 1200x1200x900 mm along with valve pit cover made out MS angle iron 50mm x 50mm x 6mm frame work, , MS platecover made out of 3.15mm thick with locking arrangment fixed over the valve pit including a coat of synthetic enamel paint over a coat of red oxide primer complete including necessary frame work welding, drilling etc complete all as specified and directed.
S&F 500 ltrs capacity tank of rotational moulded polyethylene water storage tank (Cylendrical, vertical with closed top with double layer conf to IS-12701-96 complete including provision of all inlet,outlet,overflow and drain pipe fitting incl taking out old unserviceable one complete all as directed including taking out old u/s one complete all as specified and directed.
All as per item No 53.00 mentioned here-in-above but capacity 1000 ltrs complete all as specified and directed.
S&F high pressure PTMT ball float valve suitable for size of 25 mm dia with epoxy coated aluminum rod & HD plastic ball screwed for iron pipe including GI Fitting as reqd after taking out Old U/S item complete all as specified and directed.
All as per item No 55.00 mentioed here-in-above but size 20 mm bore complete all as specified and directed.
S&F framed work such as angle of different size gusset plate (mildsteel) and cut to shape drilled and conter inner for screwing inclnbending and weldidng angle as necessary confirming to Fe-410-W(Gde E-250) Quality-B complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10cm width or girth not other wise described and appplying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F 3.15mm thick mild steel plain black sheet for earth, covering to door shutters, and covering to valve pit frame cut size edges beaded as directed , holes punched, inclding rounded head serews with plain 40mm lap, joints or welded/ reveted seams including bending, turning up mitred angle, stoped ends, outlets as required complete all as specified and directed.
M&L for cleaning of RCC/PS/GRP Over Head/UG Reservoir (Water) by Hi-Tech system using High Pressure jet Pump having putting minimum pressure of 150 Bar to clean all sludge on walls, floors, treating with Hydrogen peroxide and applying ultra violet rays to make the tank bacteria free(by using tanclean chemical) of the following capacity tanks complete all as specified and directed. Note: (i) :- Rate are deemed for writing work i.e. tank clean on (date), (month) and (year), font size should be 30 cms.(ii) The item rate include the repair to tank for any leakage after cleaning of tank and apply of one coat of limewash. (a) Over head tank 4,50,000 lts capacity (i.e 1,00,000 gallons) tanks at Pump House No 2 'D' Camp, Pump House No 4 Lal Qtr. (tank hight 21 mtr).
(b) All as per item No 60.00 mentioned here-in-above but 2,25,000 ltrs capacity (i.e 50,000 gallons) tanks at Pump House No-3 ME Line , PH 104 KLP , Pump Hose No-16 (Tank height 18 mtrs) ILP -2 PH No. 1, 2 & 03.
(c) All as per item No 60.00 mentioned here-in-above but 10000Gln capacity Masonary Tank / PS tank / GRP tank at Pump House No 6 (1 x20000), PH No- 15 PS Tank (2 x 10000), PS Tank at PH No-06 PS Tank(1x10000) (Tank height 12 mtrs).
Opening completely pressure filter & oxidation chamber of capacity 10000 GPH and taking out existing filter media (sand, gravells) stainers and nozzles, removing and depositing filter media to a distance not exceeding 50 m for reuse at site and strainer and nozzles to MES stores yard including necessary repair/welding to make the pressure filter vessels complete leak proof for improving the strength and finally reassembling the pressure filter including filling of new strainer, gravles & sand in existing position duly cleaned replacing worn out gasket and nut bolts and washers complete all as directed. (Note- Nozzles, strainers, gravels shall be measured and paid seperatley under relevant items)
Material and labour for prepration of old painted steel/iron surfaces of pressure filter & oxidation chamber by scrapping and cleaning of External and internal surfaces and applying two coats of black bituminious anti corrosive paint internal surface suitable for drinking water and Navy blue paint on outer surface marking the date of cleaning on the body complete all as specified and directed.
Supply only of PVC push type/threaded type strainer suitable for filteration plant complete all as specified and directed.
Supply only special coarse sand passing through 3.125 x 1.56 mm mesh suitable for use in filteration plant complete all as specified and directed.
Supply only special coarse sand passing through 1.6 x 3.2 mm mesh suitable for use in filteration plant complete all as specified and directed.
Supply only new washed, cleaned, dust free, gravel of grading 25 mm to 20 mm. graded filter media suitable for use in filteration plant complete all as specified and directed
Supply only new washed, cleaned, dust free, gravel of grading 20 mm to 12 mm. graded filter media suitable for use in filteration plant complete all as specified and directed.
Supply only new washed, cleaned, dust free, gravel of grading 12 mm to 06 mm. graded filter media suitable for use in filteration plant complete all as specified and directed.
Supply only new washed, cleaned, dust free, gravel of grading 06 mm to 03 mm. graded filter media suitable for use in filteration plant complete all as specified and directed.
Supply and fix in layers mix of manganese dioxide (MnO2) and treated carbofil in lumps of size 20 mm to 15 mm containing 75% of manganese Dioxide and 25% KG carbofil suitable for use in filltration plant complete all as specified and directed.
Supply and fix live catalytic media (green Sand) suitable for use in filltration plant complete all as specified and directed.
Cleaning overhead building service water tank (capacity of upto -5000 ltrs ) by high pressure and disinfections by ultraviolet radations and disposal of sludge at safe place. Rate also includes all labour, materials, equipment, plants and machinery etc complete in all respect. Total process of the cleaning comprises of following steps. (i) Cleaning of initial sludge and sedimentation etc and disposal of sludge in sludge tank carefully. (ii) Total high pressure cleanig with machines using special rotary high pressure cleaning for total removal of scaling, dirt and algae etc from the walls, pillars and flooring to thoroughly expose the original concrete wall/surface. (iii) Removal of sludge by labours. (iv) Removal of dirt, fine mud and fine particles etc. by industrial vaccum cleaner. (v) Sterilisation of walls, flooring by special anti bacterial agents for reductions of microbiological impurities. (vi) Final disinfection by special industrial ultraviolet radiations to ensure complete sterlisation of tanks. Note :- (i) Rate are deemed for writing work i.e. tank clean on (date), (month) and (year), font size should be 10 cms. (ii) Any damages of float valves and tanks due to negligence of work will be rectified/replaced by the contractor is own cost.
Repairing of defective C.I. Sluice/Butter fly valve (150 mm dia) of the plant & replacement of gland packing for smooth operation etc complete all as specified and directed.
Supply and fix in repair butter fly valve PN-1.6 , 150 mm dia use in filltration plant complete all as specified and directed
Supply and fix in repair 100 mm bore CI Sluice valve PN – 1.6 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as directed.
All as per item No 77.00 mentioned here-in-above item but 150 mm bore complete all as specified and directed.
Supply and fix in repair, connecting and testing reflux valve (non return valveIS -5312) CI suitable for 150 mm bore pipe heavy duty both end flanged of pressure rating PN 1.6 and jointing with joint with rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers complete all as specifed and directed.
Material and labour for opening of sluice valves 150 mm dia bore after de-scaling and grinding on Lathe Machine and replacement of Spindle, Gutka, valve sheet, brass rings as per existing and complete scaling and proper functioning at site refixing at existing postion inclcluding nut, bolt, washer, gasket, wheel complete all as specified and as directed.
Testing of Water Samples for Chemical analysis as mentioned below from Pump Houses viz PH No - 104 AD KLP ,PH No 2 ‘D’ Camp, PH No 4(Lal Qtr), PH No 6 (Stn HQ), PH No 3 ME Line , PH No-15 (FAD Perimeter), PH No-16 (DRDO), PH No 19(Gate No-1), PH-9 (Swimming Pool), Pocket-II (PH-1 2 & 3) complete all as specified and directed. Note: Testing of Water for Raw Water & Filtererd Water for total 12 Pump Houses in three month Basis. Testing of Raw water and Treated water in Each PH consider as One Job (a) PH Level (b) Specific Conductivity (c) Chloride (CL) (d) Total Harness as Ca CO₃ (e) Iron as (FE) (f) Arsenic (AS) (g) Total dissolved solids Note for above Item (a) Sample of Water for the above media test are to collected in transparent container/Jar/bottle separately for each test against each pump houses. (Hygienically clean bottles). (b) Sample of water to be collected shall be forwarded to Govt Lab. (c) Testing of Water shall be carried out at the office of Senior Geologist, Geological Sub Divn No-II, Spandan Complex, Ist Floor, Burdwan (Opposite Municipality office near Burdwan Rly Station (WB). OR any authorized State/central Govt Lab.
Pumping out sewage water from the existing sumps of sewage plant Pump house with the help of Non clogging of pump any kind capacity of pump set not less than 2160 LPM capacity 15HP/20 HP (Minimum) So as to vacate the sumps to enable the repair of the main non clogging submersible pump sets installed in the pump house. Note :- (a) Pumping shall be continued till the main pumps installed in sewage sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of central sewage plant towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Lifting the non clogging pump set electrically operated by 15HP/20 HP 3 Phase motor incl column pipe, line shaft etc after disconnecting of all elect and water line connection for the any make of pump & motor complete all as specified and directed.
Dismantling of non clogging submersible pump of capacity 15HP/20 HP and taking out burnout winding from the stator of motor and rewinding with PVC copper wire as per existing gauge incl connection commissioning & testing complete all as specified and directed
Lowering complete the non clogging pumping set and reflixing the motor carefully including connection and testing complete all as specified and directed
Pumping out sewage water from the existing sumps/tanks of STPs (MBBR technology) with the help of Non clogging of pump any kind capacity of pump set not less than 1500 LPM capacity 10HP/15 HP (Minimum) along with tanking out mud/ solid sludge from the tank complete from soild sepration chamber, aeration chamber and despose whole sludge to faraway areas from public places including cleaning of sump completely. So as to vacate the sumps to enable the repair of the main non clogging pump sets installed in the STPs. Note :- (a) Pumping shall be continued till the main pumps installed in STPs sump is cleared for carrying out repair work. (b) Delivery pipe should be connected and the sewage water shall be thrown in the manhole of out side the fencing /wall of STPs towards the main gravity dropping main hole. (c) Pumping of sewage water still be continued till the sumps are fully empty and to keep till the installed non clogging pump are repaired & fully operative. (d) Necessary man power to operate the pump set are deemed to be included in the rate. (e) Rate quoted is deemed to include for Diesel/Engine oil till completion of repair work including testing of sewage pump set. (f) Rate included for transportation of pump set to site/back.
Lifting the non clogging submersible pump set electrically operated by 3.7 HP 3 Phase motor incl column pipe, line shaft etc after disconnecting of all electric and water line connection for the any make of pump & motor complete all as specified and directed.
Dismantling of non clogging submersible pump of capacity 3.7 HP and taking out burnout winding from the stator of motor and rewinding with PVC copper wire as per existing gauge incl connection commissioning & testing complete all as specified and directed
Lowering complete the non clogging pumping set and reflixing the motor carefully including connection and testing complete all as specified and directed
Dismantling of electric sewage induction motor 3.0 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, refixing the same at site and connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump complete all as specified and directed.
Dismantling Non clogging pump set of centrifugal type (3.0 HP induction motor), AC, 3 phase, 415 volts from site after disconnecting of suction and delivery line, taking out to work shop, dismantling pump set for overhauling, replacing u/s shaft sleeve, gland packing, bush, water seal, applying grease etc reassembling the pump set and refixing back at site on the base plate and connecting existing pipe line with nuts, bolts and new gasket, connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump complete all as specified and directed.
Dismantling of electric induction blower motor 5.0 HP, AC, 3 phase, 415 volts from site after disconnecting from pump & electric connection for rewinding, taking out to work shop, opening of motor, taking out old worn-out / burnt-out winding complete, cleaning the slots properly and rewinding with supper enamelled copper wire as per existing gauge and varnishing complete, and reassembling after repairs and replacement of parts as required, refixing the same at site and connecting the electric connection with existing cable etc and including painting of external portion of pump with synthetic enamel paint (1 st quality) of two coat after one coat priming of red oxide primer and testing for satisfatory working of pump complete all as specified and directed.
Material and labour for PCC 1:3:6 type C2 (using 40mm graded aggregate) for foundation etc including necessary fram work complete all as specified and directed.
Testing of Sewage Water Samples for BOD annd COD testing analysis as mentioned below from STPs viz STP ILP-II - 04 Nos, STPs FAD- 01 Nos, STPs 59 DOU- 01 Nos complete all as specified and directed. (a) BOD (b) COD (c) PH Level (d) Total Suspended Soild(TSS) (e) Outlet Coliform Note: Testing of Sewage Water Treated sewage Water for total 06 STPs in three month Basis.(i.e Treated Sewage water in Each STPs consider as one Job) (a) Sample of Sewage Water for the above media test are to collected in transparent container/Jar/bottle separately for each test against each STPs. (Hygienically clean bottles). (b) Sample of water to be collected shall be forwarded to Govt Lab / any authorized Lab
M & L for taking out & servicing of existing unserviceable Air Blower (of any Make ) of capacity 188 Cubic/Hr from Authorised sevice center with taking out of electric cable complete and reconnecting the electric and mechanical connection at existing location after carrying out following repairs all as specified and directed by Engineer-in- charge.(Note- Spare part required for replacement shall be measured and paid separetly and cost of taking out of old & fixing new if any ordered for item No 35 to 40 and replacement of Oil seal, replacement of locking arrangement of pully, replacement of gland packing with oil and greasing shall be deemed to be including in quoted rate of this item).
Supply only Gear oil EP 90
Supply only Air filter suitable for above
Supply only belt as per existing model
Supply only bearing (Make- SKF)
Supply only set of rotor with hub as per existing model
Supply only set of gear with hub as per existing model
Repair to the Induction motor (440 Volt 50 Hz) Power of capacity 5 HP for blower in STP plants by dismantling the rotor complete rewinding the stator with proper gauge of super enamelled copper wire including changing of insulating material proper heat varnish, painting replacement of bearing complete & connected with complete all as specified and directed by Engr-in-Charge.
M & L for finding out defect of STPs panel and taking out burnt interconnection wiring including U/S and serviceable component for re use including rewiring of panel using existing size of copper cable,ferrule , lugs, insulating materials, nut bolts washer of various sizes refixing serviceable items complete all specified and directed
Supply and fix in repair, flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 4 Sqmm 3 core including jointing material and connection work complete all as specified and directed.
Supply and fix in repair, flexible flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 10 Sqmm 3 core including jointing material and connection work complete all as specified and directed.
S & F round strand steel wire rope dia 12 mm and connected clamp nut bolts fixed complete all as per directed.
S&F Submersible pump Fully Automatic Star delta Starter Type MU-G Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 25 HP,Relay range of 17-25 A as per existing after taking out old U/S complete all as specified and directed.
S&F Start Push Button as per existing after taking out old U/S complete all as specified and directed.
S&F Stop Push Button as per existing after taking out old U/S complete all as specified and directed.
S&F Pressure gauge for blower as per existing fter taking out old and unserviceable complete all as specified and directed
Supply and fix in repair Butterfly valve PN-1.0, 50 mm dia use in STPs complete all as specified and directed
S&F nylon tube ¼ “ dia for chlorine dozing system complete all as specified and directed.
S&F NRV 8 mm dia (antisyphon valve) for chlorine dozing system complete all as specified and directed.
Suplly and fix Plastic MBBR Filter Bio media for sewage water treatment of size 25x12 mm black in colour complete all as specified and directed.
Supply and fix in repair MS Column pipe 150 mm dia, 3mtr length medium grade flange type both ended with complete fitting complete all as specified and as directed.
Material and labour for Dismantling of old unservicable Direct online starter and Supply and fixing for Direct online starter for induction motor Pump set of rating 5 HP, 415 volts, 50 Hz having with sheet metal encloser and relay range 3 phase 7 to 10 Amps rating panel mounting complete all as specified and directed.
m/s friends construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .