Executive Engineer PHE Division Poonch
Executive Engineer PHE Division Poonch
Installation, Testing Commissioning of HCP set 6000 GPH X 325 MH X 60 HP , 150 KVA manual voltage stabilizersand providing/fitting SPS 6000GPH X 60 MH x 25 HP, control panel 60 HP and 25 HP at Pumping station BasooniDharanaBorewell under WSS Brella
2020_IFC_91257_9
e-NIT No.65 of 2019-20 Dated- 25-01-2020
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
15 days
Poonch
Please refer Tender documents.
3 documents required · 3 mandatory
₹600
Yes
Executive Engineer PHE Division Poonch
₹12,500
Yes
12 Feb 2020
25 Jan 2020
8 Feb 2020
27 Jan 2020
7 Feb 2020
27 Jan 2020
Amount
shifting of Horizontal pump set 6000GPH x 300 MH x 60HP Induction motor & base frame along with 150 kva voltage stablizar from Divisional store chandak by departmental vehicle by using chain pulley block/crane and manual labour & unloading at road side shifting to P/S basooni dharana mdr. Head load carriage of machinery from road side to Pumping Station by making arrangement and using of manila rope, wooden logs etc.The job includes cost of manila rope.Excavation of trench for laying of foundation block of size 2.00mtrs×0.80mtrs×0.60mtrs,disposal of earth etc. about 50mtrs away from the trench. Laying of RCC foundation block for HCP set in 1:2:4 mix sufficiently elevated with respect to floor level. Fabrication & fitting of foundation/Anchor bolts of required size, 06 nos and fixing of base frames on the foundation blocks with the help of foundation / anchor bolts by tightening of foundation bolt and its proper leveling by using leveling tool. Curing of foundation block for one week. Placing/fitting of HCP & motor on base frame, fitting of coupling pulley set, it’s tightening with nuts bolts & washers after its proper leveling with steel shims etc. The job also includes labour charges for skilled/unskilled.Labour for material like sand, bajri, its carriage, loading of cement, steel from divisional store and unloading at road side and shifting it to pump room.Laying/fitting of Suction and delivery pipe line of size 80 mm dia. of GI pipe (Medium) 13mtrs to be provided by the deptt..Providing & fitting of machined flanges for suction and delivery sides of pump. Cutting of pipes with cutter at site according to alignments of suction/delivery pipe line. P/f of MS bends 80mm Ø, CI heavy duty reflux valve 80mmØ, CI HD sluice valve 80mm Ø MS flanges 65mmØ, nuts, bolts, washers, RI sheet 10Kg. Welding work at sight for welding of GI pipe, flanges, bends etc. Fabrication of bend angles according to alignment of suction & delivery. Complete job includes cost of material CI HD reflux valve 80mmØ at delivery line,CI HD sluice valve 80mm Øat suction line,machined MS flanges 80mmØ 4nos as per required size, MS bends, nuts, bolts, washers .Hire charges of welding set, cutter, grinder at site,cost of welding electrodes. Labour charges for skilled/unskilled. Job excludes cost of GI pipe 65mmØ 15 mtrs. Installation of 150 KVA manual Voltage Stabilizer. Shifting of voltage stabilizer along with Transformer oil (to be provided by the department) from Divisional store at Chandak upto road side pumping station near the approachable site and manual carriage from there to pumping station. Electrical Installation by way of fab./fitting of 01 no angle iron frame 2'x4' and drilling of holes for fitting of kit ply board 19mm thick water proof of size 2'x4'.Painting of angle iron with one shade of primer & two shade of high quality black paint.P/f of mica as per size of board.Providing and fitting of main switch 400 Amps, 440 volts of good quality ISI make, it’s fitting at existing panel board.
Designing /fabrication/ Installation/ Testing and Commissioning of Automatic LT control Panel of 415 volts, AC 3Phase 60HP capacity .The panel should be rust and vermin proof. fabricated out of 16 SWG CR sheet supported on MS angle of suitable size and provision for fixing it on panel board. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangement. The structure should be provided with suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of enamel paint. It should be equipped with following components/features:-MCCB:-The panel should be fitted with MCCB 160 Amp, 415 V, 35KA capacity to protect the panel in case of short circuit. VOLTMETER:- The panel should be fitted with digital voltmeter to show the voltage between phase to phase and between phase to neutral. AMPERE METER:- The panel should be fitted with digital Ampere meter CT operated to show the ampere between each phase. PHASE INDICATOR:-The panel should be fitted with phase indicator R/Y/B to indicate the phase. STAR-DELTA STARTER:-The panel should be fitted with 02No contactors 110Amp (L&T Make/ reputed Make) for main and Delta and 01 No contactors 70 Amp for star operation, 1No timers for change over the supply of motor from star to Delta,2No push buttons for start and stop operation of motor,1No thermal relay range of suitable capacity fitted with main contactors. All control wiring should be neat and clean with flexible copper cable to complete the star Delta circuit of outgoing supply and wiring should be protected with fuse. The system should provide protection against:- • Low Voltage below 350 V. • High Voltage above 450 V. • Single phase • Reverse Phasing • Unbalance phasing • Dry running • Over loading Testing and commissioning of control panel by making/connecting to incoming terminals and outgoing terminal of control panel. Testing the performance of the panel on no load and on full load. Complete job includes cost of material, labour charges, carriage charges& fitment charges at the site of work.
P/F of37/16 cu cable 50 mtrsapprox. in length from voltage stabilizer to panel & panel to motor, its thimbling, crimpling by using crimpling tool etc.P/F of Al.Cable 300mm Sq. 50 mtrs in length H/D to be layed for making connection from LT pole to main switch to volt stabilizer for all three phases..The complete job includes cost of material and labour charges and hire charges of vehicle,charges skilled/unskilled and testing and commissioning of HCP set on full load.Testing and commissioning of HCP set after checking of alignment of pump & motor, and voltage stabilizer checking all the electrical connections with megger, tightening of loose connections if any, plugging of leakage of joints by welding & tightening of nuts & bolts etc.
Providing/ Installation, testing and commissioning of submersible pump set 6000 GPh x 60 MH along 25HP submersible motor at pumping station borewell basooni dharana by way of shifting pumpset to pumping station. Job includes head load carriage and tools and tackles required for shifting of machinery upto pumping station. Fabrication of 10 No. G.I. column pipes of 80 mm dia 10 feet in length each (G.I. pipe to be provided by the department) suitable for lowering inside 200 mm dia casting of bore well by way of turning of both the ends of each column pipe of lathe. Providing and welding suitable MS flanges with 4 No. holes one each side of column pipe with proper alignment. The top column pipe shall be fabricated by providing one No. MS flange of size 250 mm dia in the centre so as to rest the completes connected column pipes with submersible pump motor set in 200 mm dia casing pipe. One end of the top column pipe shall be provided and welded with 80 mm dia MS bend with proper flange and suitable no. of holes for fitment of reflux valve. Fabrication of expander nipple with on 80 mm dia flange on one side and other side to be fitted with submersible pump set filling of distilled water inside the submersible motor for cooling the motor windings. Coupling of pump and motor checking of alignment of pump and motor and then testing the motor pump at workshop. Providing & fitting of 10 Sqmm Sub cable 230 mtr in length, making connections with submersible motor by using hot patch rolls, Insulation material thumbling by using copper thimbles of required specifications, crimpling by using crimpling tools. Then lowering of submersible pump set along with submersible cable in the liner assembly by assembling column pipes one by one with providing & fitting of rubber gaskets, nuts, bolts at each points. Fitting of top column pipe having blind flange of 250mm dia. Fabrication and fitting of extension pipe with flanges as per site requirement making provision for interconnection with sump tank. Job includes cost of material & labour charges . Designing /fabrication/ Installation/ Testing and Commissioning of Automatic LT control Panel of 415 volts, AC 3Phase 25HP capacity Submersible Motor Installed at borewell.The panel should be rust and vermin proof. fabricated out of 16 SWG CR sheet supported on MS angle of suitable size and provision for fixing it on panel board. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking/sealing arrangement. The structure should be provided with suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of enamel paint. It should be equipped with following components/features:-MCCB:-The panel should be fitted with MCCB 160 Amp, 415 V, 35KA capacity to protect the panel in case of short circuit. VOLTMETER:- The panel should be fitted with digital voltmeter to show the voltage between phase to phase and between phase to neutral. AMPERE METER:- The panel should be fitted with digital Ampere meter CT operated to show the ampere between each phase. PHASE INDICATOR:-The panel should be fitted with phase indicator R/Y/B to indicate the phase. STAR-DELTA STARTER:-The panel should be fitted with 02No contactors 110Amp (L&T Make/ reputed Make) for main and Delta and 01 No contactors 70 Amp for star operation, 1No timers for change over the supply of motor from star to Delta,2No push buttons for start and stop operation of motor,1No thermal relay range of suitable capacity fitted with main contactors. All control wiring should be neat and clean with flexible copper cable to complete the star Delta circuit of outgoing supply and wiring should be protected with fuse. The system should provide protection against:-
• Low Voltage below 350 V. • High Voltage above 450 V. • Single phase • Reverse Phasing • Unbalance phasing • Dry running • Over loading
Testing and commissioning of control panel by making/connecting to incoming terminals and outgoing terminal of control panel. Testing the performance of the panel on no load and on full load. Complete job includes cost of material, labour charges, carriage charges& fitment charges at the site of work. Complete job Testing & commissioning of submersible pump set checking all electrical connection with megger tightening of loose connections if any, plugging of joints by welding and tightening of nuts, bolts. Job includes cost of material and labour charges for loading unloading carriage fitting & testing charges
Vaibhav Engineers and Technocrates
R M ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .