| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.2 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹25.2 L+₹30,378 (1.22%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹26.4 L+₹1.4 L (5.72%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹26.9 L+₹1.9 L (7.74%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹27.4 L+₹2.5 L (9.98%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
2 Dec 2019, 6:00 pmClosed
GE E/M Lucknow.
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
REPAIR REPLACEMENT OF OH, UG CABLE, APFC PANEL, SERVO VOLTAGE STABILIZER INCLUDING REPAIR REPLACEMENT OF LIGHT FITTINGS AND OTHER CONNECTED WORKS UNDER AGE E/M HOSP OF GE E/M LUCKNOW.
2019_MES_294146_1
GE/EM/HOSP/53 OF 2019-2020
Open Tender
Civil Works
Item Rate
180 days
Lucknow Cantt.
Class D or above, category b (i).
8 documents required · 8 mandatory
₹500
GE E/M Lucknow.
₹80,000
Yes
6 Feb 2020
1 Nov 2019
4 Dec 2019
7 Nov 2019
2 Dec 2019
20 Nov 2019
Amount
Repair/maintenance of APFC Panel board upto 220 KVAR capacity with replacement of unservicable spare part/components modification of control wiring as required including flexible copper wire lugs complete all as directed. Note : New spares required shall be measured and paid seperately under respective items as supply only.
Supply only APFC Relays fourteen stage, 240 Volts complete all as specified and as directed. Make: L&T, Cat No- MRPM 1400000 or equivalent make of TATA Livert/Crompton Greaves/Siemens/Havells
Supply only moulded CT with CT ratio 100/5 VA, class-I rectangular shape complete all as specified and as directed.
Supply only moulded CT with CT ratio 200/5 VA, class-I rectangular shape complete all as specified and as directed. Make: Areva/Kappa/Pragati
Supply only LED indicators red, yellow and blue 240 V AC complete all as specified and as directed.
Supply only contactor type MNX 25 240 V complete all as specified and as directed.
Supply only contactor type MNX 45 240 V AC complete all as specified and as directed .
Supply only control fuses type HF 2 to 6 A complete all as specified and as directed .
Supply only capacitor 20 KVAR cylindrical type 440 volt 3 phase complete all as specified and as directed.
Repair to Voltage Stabilizer, servo type of capacity 100 to150 KVA at site including carrying out maintenance check along with the following other repairs: (i) Dismantling of voltage stabilizer top cover for replacement of unserviceable parts without lifting core assembly. (ii) Assembling of voltage stabilizer after replacement of unserviceable parts with new serviceable parts as ordered by Engr in Charge. (iii) Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. Notes : (a) The parts required to be replaced will be measured and paid separately as 'Supply only' against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department.
Dimmer stat for 100 to150 KVA voltage stabilizer.
Servo card for 100 to150 KVA voltage stabilizer.
Servo motor for 100 to150 KVA voltage stabilizer.
Control wiring for 100 to150 KVA voltage stabilizer.
High/ low voltage cutout circuit for 100 to150 KVA voltage stabilizer.
Control transformer for 100 to150 KVA voltage stabilizer.
Relay for 100 to150 KVA voltage stabilizer.
Toggle switch for 100 to150 KVA voltage stabilizer.
Push button for 100 to150 KVA voltage stabilizer.
Voltmeter 0-500 volts for 100 to150 KVA voltage stabilizer.
Ammeter 0-100 Amps for 100 to150 KVAvoltage stabilizer.
Repair to Voltage Stabilizer, servo type of capacity 30 to 75 KVA at site including carrying out maintenance check along with the following other repairs: (i) Dismantling of voltage stabilizer top cover for replacement of unserviceable parts without lifting core assembly. (ii) Assembling of voltage stabilizer after replacement of unserviceable parts with new serviceable parts as ordered by Engr in Charge. (iii) Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. Notes : (a) The parts required to be replaced will be measured and paid separately as 'Supply only' against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department.
Dimmer stat for 30 KVA to 75 KVA voltage stabilizer.
Servo card for 30 KVA to 75 KVA voltage stabilizer.
Servo motor for 30 KVA to 75 KVA voltage stabilizer.
Control wiring for 30 KVA to 75 KVA voltage stabilizer.
High/ low voltage cutout circuit for 30 KVA to 75 KVA voltage stabilizer.
Control transformer for 30 KVA to 75 KVA voltage stabilizer.
Relay for 30 KVA to 75 KVA voltage stabilizer.
On load change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
On load change over switch, 100 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
On load change over switch, 63 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all specified & directed.
S&F breather assembly complete with silica gel suitable for any model of transformer rating 50 to 500 KVA
Supply and fill transformer oil of good quality having not less than 46 KV dielectric strength at site or factory premises for toping up or replacing the old oil Make- Savita/Power oil as per IS 335 of 1983 all as specified.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Earth continuity conductor of 32x6mm galvanised iron strip with saddle and fixing screw for conductor above ground
M&L for RCC 1:2:4 type B-1 using 20mm grade stone aggregate as in duct cover, cover slaps etc including necessary for work
Dehyration and filteration of existing serviceable oil in the transformer till it achieves the required dielectric strength using dehydration plant complete as directed at site by Engr in Charge.
Disconneting the exisitng cable from panel / pole, preparing the end for jointing and S&F heat shrinkable jointing kit for 1100 Volts grade cable, straight through joint complete with jointing materials and accessories suitable for upto 50 sqmm 3 ½ core sizes of XLPE armoured cable aluminium conductor cable complete all as specified and directed.
All as per item No 40 above but 70 sqmm to 120 sqmm 3 ½ core
All as per item No 40 above but 150 sqmm to 400 sqmm 3 ½ core
S&F hot shrinkable, in door type, cable termination kit with all accessories suitable for 11 KV HT XLPE Cable of size 95 sq mm, connecting the cable in RMU, including all earth work and making good disturbed surfaces and making all connection in RYB phase sequence complete all as specified and directed.
S&F cold shrinkable, outdoor type, cable termination kit with all accessories suitable for 11 KV HT XLPE Cable of size 95 sq mm, connecting the cable in RMU, including all earth work and making good disturbed surfaces and making all connection in RYB phase sequence complete all as specified and directed.
S&F cold hrinkable straight through joint suitable for upto 120 and sqmm, 3 core 11 KV HT XLPE cable by ensuring RYB phase sequence including all accessories and connections of cable in RMU complete all as specified and directed.
Supply & fixing in replacement Isolator Four Pole 100 Amp, 415 volts complete all as specified
Supply & fixing in replacement MCCB Four Pole 63 Amp,10 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCCB Four Pole 63 Amp,10 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 100 Amp,10 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 125 Amp,10 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 160 Amp,10 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 250 Amp,36 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 400 Amp,36 kA, 415 volts 'B' curve complete all as specified
Supply & fixing in replacement MCB Four Pole 600 Amp,36 kA, 415 volts 'B' curve complete all as specified
Disconnecting & taking out defective under ground cable from trenches, pole, pipe, floor ,wall etc locate the fault, rectify the defect and relaying the XLPE cable under ground PVC insulated and overall sheathed aluminium conductor heavy duty LT/HT 1100/11000 volts connecting and testing for any size complete as directed by Engineer-in-Charge (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
All as per item No 56 above but of size 10 Sqmm 4 core
All as per item No 56 above but of size 16 Sqmm 4 core
All as per item No 56 above but of size 25 Sqmm 4 core
All as per item No 56 above but of size 50 Sqmm 3.5 core
All as per item No 56 above but of size 70 Sqmm 3.5 core
All as per item No 56 above but of size 95 Sqmm 3.5 core
All as per item No 56 above but of size 150 Sqmm 3.5 core
All as per item No 56 above but of size 185 Sqmm 3.5 core
All as per item No 56 above but of size 240 Sqmm 3.5 core
All as per item No 56 above but of size 300 Sqmm 3.5 core
Supplying, laying, jointing, testing and commissioning in replacement HT under ground electric power cable Crossed linked polyethylene ( XLPE) insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earth system of 3 core 95 Sq mm cross sectional area size, ISI marked as per IS 7098 Part-2, laid in trenches/ laid under floor/ laid in ducts or fixed on poles etc. complete all as specified and directed. Note :- Excavation/ boring of raod/ pipe shall be measured and paid separately under appropriate items.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Laying only old burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified.
M&L for taking proper shut down, disconnecting incoming / out going cable, control cable from 11 KV OCB/VCB of any type and capacity upto 630 amps and carrying out complete servicing / overhauling, resetting of all electrical and mechanical parts for easy and proper operation, greasing of moving / revolving / sliding parts in VCB Panel, calibration of relays, meters incl thorough cleanining with air blower / vacuum cleaner, decarbonising & providing mineral jelly to all arcing contacts of the VCB panel, and serviceability check from local / remote control panel including replacement of unserviceable minor spare parts viz. nut / bolt / washer / connecting wire / insulation tape / sleeves etc complete including reassembling complete parts reconnecting incoming / outgoing cable, testing on load and all as specified and directed by Engr-in-Charge. Note- 1. Unserviceable items other than minor parts to be replaced will be meaured and paid seperately as supply only under revelent items in the schedule. However, cost of certain minor spares viz nut / bolt / washer / connecting wire / insulation tape / sleeves etc. if required shall deem to be included in the cost of repair of the item. 2. The spare parts to be replaced shall be of reputed brand / make and shall be of same type, design, specifications etc to match with the existing and as per the recommendation of OEM. 3. Complete servicing and calibration work shall be carried out by qualified and reputed service engineer only.
Space Heater 230 V AC
Motor and gear assembly 110 V AC/DC VMG -14 type
S&F Digital type Volt meter 0-15KV, PT operated 110 Volt input complete all as specified and directed. Make - AE/ Nippen
S&F Digital type Ampmeter CT operated, 5 Amp input complete all as specified and directed. Make - AE/ Nippen
M&L for stay assembly comprising of 16mm dia, 1.80 meter long galvanized stay rod , having 7 / 3.15mm GI stay wire stranded and 230mm X 230mm X 6mm thick stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I 2009 with and including all necessary fittings/accessories like loop type insulator, stay clamps complete all as specified and directed by Engineer-in-Charge including taking down and dismantling old unserviceable stay assembly.
Supply, fixing , commissioning and testing in replacement of outdoor type , 11 KV gang operated switch with drop out fuse assay complete of current rating upto 200 Amps 4 insulator Vertical type triple pole each pole consisting of galvanized steel based HT insulator as per IS non ferrous knife and spring loaded contacts, arching horns of adequate section to break magnetizing current of the transformers horizontol Gi of adequate length for phase separation , adequate length of GI pipe operation from ground level and operating handle with locking arrangement complete in both OFF and ON positions. All ferrous parts hot dripped galvanized and non ferrous heavily tinned to with stand weather suitable for vertical mounting including taking out old GOD complete all as specified and directed. Make:- Jaipuria/BHEL/Pactil
Supplying ,fixing in replacement of danger notice board of 1.6 mm thick mild steel sheet , viterous enamelled white , with letters , figures and conventional skull and bones in signal red colour and fixed with MS clamps , bolts for HT 25X20 cm size complete all as specified and directed.
M&L for painting of two pole/four pole structur including cross arms,chanel etc complete structure after scraping old paint with two coats synthetic aluminium paint after applying one coat of zinc oxide primer complete all as directed by Engr-in-Charge
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm. Make : Denson/Raychem/M Seal
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable size 95 sqmm. Make : Denson/Raychem/M Seal
Supply and filling in repair/replacement of silica gel in existing breather assembly. Make : MB Supplier/Pooja industries/Goyal electric works
Supply & fixing in repair/replacement of breather for 250 KVA to 750 KVA Transformer. Make : MB Supplier/Pooja industries/Goyal electric works
Supply & fixing in repair/replacement of breather for upto 250 KVA Transformer. Make : MB Supplier/Pooja industries/Goyal electric works
S&F in replacement of HT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for (11/0.433 KV) 50 KVA TO 630 KVA Transformer complete in all respect & all specified. Make : Neelachal Transformers Pvt Ltd/Power & Distribution transformer
Supply and fix Temperature gauge suitable for transformer of capacity above 100 KVA and upto 750 KVA complete all as specified and as directed.
M&L for painting in two coats with first quality of synthetic enamelled paint over a coat of red oxide primer after complete removal of existing finish to step up / step down transformer of capacity 50 to 750 KVA incl writing of its corrosponding MES No / Sl No / maintenance date etc complete all as spd and as directed by Engr- in- Charge. (Note: Proper shutdown including dismantling of primary / secondary connections and refixing the same to be ensured)
S&F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for 50 KVA TO 300 KVA Transformer complete in all respect & all specified. Make : Neelachal Transformers Pvt Ltd/Power & Distribution transformer
All as per item No. 92 above but suitable for transformer of capacity 400 KVA to750 kva
M&L for pin type, porceline, vitreous, brown insulator including one Galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut of 150 mm height, 150 mm dia for 11000 volt grade including taking down old insulator all as directed by Engineer-in-Charge. Make : JAIPURIA/RASHTRIYA/oblum
Disconnection and taking out unserviceable distribution Transformer of capacity up to 750 KVA 11/0.415 KV from sub station for the following phase of worksspecified and directed by Engineer-in-charge Note :- (i) Cost of Supply and fixing of nuts, bolts, washers fevicol sleeves cotton tapes etc shall be deemed to be included in quoted rate. (ii) Necessary test of Transformer shall be carried out by factory as per is in presence of MES representative and Test report shall be submitted to the department. (iii) All item above are having tentative quantity and specification and may change as per ground requirment.
M&L for carrying out replacement of all Gasket using rubber cork sheet of 6.0 mm thick including providing gasket cement adhesive all as specified and directed by Engineer-in-charge.
Disconnecting the transformer indoor / out door from HT / LT side at site dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strip and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing 5 mm thick rubberised cork sheet gasket for tank top cover and replacement of gaskets/oil seal of HT/LT side to arrest the leakage of transformer oil complete reassembling the complete dismantled items, reconnecting the HT/ LT supply cable ends at the site for the Transformer capacity upto 250 KVA complete all as directed by engineer in charge.
All as per item No 97 above but Transformer capacity 200KVA to 750 KVA
Material and Labors for shifting of transformer from one area to another area and placing in position including installation testing and commissoning as per site requirement complete all as specified and directed by Engr-in-charge . 4
Disconnecting & taking out old existing unserviceable HT cable of size 3 core 95 Sqmm ,in any position from trench/duct, cleaning the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers or GI pipe of any description for remove/re-use all as directed by the Engineer –in-Charge.
Re- laying connecting and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric power cable with aluminium conductor 11000V grade cross sectional area 95 Sq mm 3 core complete all as specified and directed. (Note item retreived from Sl No.41 here-in above)
Power pack of suitable capacity contained maintenance free battery and charger to provide auxilary power supply to the VCB all as per OEM recommendation or directed by EIC. Make : Powertech Pvt Ltd or equivalent.
Supply and fixing of LED street light fittings with mandatory driver set having pressure die cast aluminium bodyand lenles suitable for 45 watt confirming to IP 66 and IK 08 protection having company LOGO ingraved cpmplete in respect with minimum 5500 system lumens high power LED with lences 11o lumen per watt system efficacy power factor >0.95 THD<10% AT FULL load CRI>70% , EVERY LIFE class 50000 hrs at the L70 poted driver set (not circutery) with BIS no return on it face to face protection on 440 volt and 325 volt (_+) 15 volt ) autocut and restart features in built all to relevent doucuments related to luminiaries and driver needed to submit for approval . Make Phillps , Havells & CG
Supply and fixing of LED street light fittings with mandatory driver set having pressure die cast aluminium bodyand lenles suitable for 60 watt confirming to IP 66 and IK 08 protection having company LOGO ingraved cpmplete in respect with minimum 5500 system lumens high power LED with lences 11o lumen per watt system efficacy power factor >0.95 THD<10% AT FULL load CRI>70% , EVERY LIFE class 50000 hrs at the L70 poted driver set (not circutery) with BIS no return on it face to face protection on 440 volt and 325 volt (_+) 15 volt ) autocut and restart features in built all to relevent doucuments related to luminiaries and driver needed to submit for approval . Make Phillps , Havells & CG
Supply and fixing of LED street light fittings with mandatory driver set having pressure die cast aluminium bodyand lenles suitable for 120 watt confirming to IP 66 and IK 08 protection having company LOGO ingraved cpmplete in respect with minimum 5500 system lumens high power LED with lences 11o lumen per watt system efficacy power factor >0.95 THD<10% AT FULL load CRI>70% , EVERY LIFE class 50000 hrs at the L70 poted driver set (not circutery) with BIS no return on it face to face protection on 440 volt and 325 volt (_+) 15 volt ) autocut and restart features in built all to relevent doucuments related to luminiaries and driver needed to submit for approval . Make Phillps , Havells & CG
Supply and fixing of LED street light fittings with mandatory driver set having pressure die cast aluminium bodyand lenles suitable for 172 watt confirming to IP 66 and IK 08 protection having company LOGO ingraved cpmplete in respect with minimum 5500 system lumens high power LED with lences 11o lumen per watt system efficacy power factor >0.95 THD<10% AT FULL load CRI>70% , EVERY LIFE class 50000 hrs at the L70 poted driver set (not circutery) with BIS no return on it face to face protection on 440 volt and 325 volt (_+) 15 volt ) autocut and restart features in built all to relevent doucuments related to luminiaries and driver needed to submit for approval . Make Phillps , Havells & CG
Supply and fixing Copper wire 2.5 Sqmm with earth wire 1.5 Sqmm including casing caping / counduit complete all as specified and directed.
Supply and fixing Copper wire 1.5 Sqmm with earth wire 1 Sqmm including casing caping / counduit complete all as specified and directed.
Supply and fixing of LED flood light driver inside a PDC housing set having pressure die cast aluminium bodyand lenles suitable for 35 watt confirming to IP 66 and IK 08 protection having company LOGO ingraved cpmplete in respect with minimum 5500 system lumens high power LED with lences 11o lumen per watt system efficacy power factor >0.95 THD<10% AT FULL load CRI>70% , EVERY LIFE class 50000 hrs at the L70 poted driver set (not circutery) with BIS no return on it face to face protection on 440 volt and 325 volt (_+) 15 volt ) autocut and restart features in built all to relevent doucuments related to luminiaries and driver needed to submit for approval . Make Phillps , Havells & CG (cat part No BVP120LED 35 CW FG S1 PSU GR)
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
S&F LED street light 30 Watt made of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover with IP 66 protection fixed on street light pole/ bldg with clamps , nuts and bolts Make Havells,CG,Phillips , Notes : Old street lights to be deposited to AGE E/M Stores.
S & F in repair integral post top lanterns 'CELESTA' light fitting type BNCL 70MH 0 Complete of Bajaj or any other specified make and making necessry electrical connections with two run of PVC insulated 2.5 sq mm nominal dia single core multi stranded copper cable all as specified and directed by Engr-incharge.
S & F steel water tubing light grade galvanised with all fittings laid in trenches/fixed with wall/laid on floor of 40 mm bore.
S&F sheet metal enclosure for DB,s when MCB to be used Single pole & neutral one way without bus bar
M&L for sand cushioning to UG cables (8 cm deep before laying of cable and 15cm deep over the cable)
Supply & Laying sub class `B’ bricks old sizes over the HT/LT cable laid flat for protection of cable.
Supply LED lamp 9 watt 2 pin . Complete all as specified and directed
Supply only CFL 36 watt complete all as specified and directed
Supply & fixing GI brackets made of 40 mm nominal bore GI pipe medium grade of required length not less than 1.5 M long, mounting brackets made out of Mild steel FI 40x6 mm of required shape ( two Nos) duly fitted with Mild steel nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide Zn chrome primer and fixed to pole / walls etc complete all as specified.
S&F MS Junction Box made of 1.6 mm thick MS sheet of size 300mmx200mmx150mm complete with front openable hinged cover and locking arrangements with 4 Nos aluminium bas bar 100 Amps, mounted on porcelin insulator including M&L for MCB SP 10-1No, fixed on box in Din rail complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duly painted with powder coated paint complete all as specified and directed.
Supply and fix Isolator 100 Amps FP AC 230 volt 50 hz . Complete all as specified and directed
Supply only cross two pin CFL 18 watt AC 230 volt 50 HZ Complete all as specified and directed
S&F in repairs Compact Fluorescent lamps ( CFL) cross pin18 watts yellow in colour of Make Bajaj or equivalent of other specified make.
Labour only for maintenance of street light fittings HPSV/ MH any watt of any make / model fitted to pole at any height with any type of fixing arrangement replacement / renewal the ballast, lamp, holder, ignitor etc. as required at site and flexible wire tightening the required connection etc. complete all as specified and directed. Note :- Spares i.e. Ballast, lamp holder, lamp, iginitor etc. shall be measured and paid separately as supply only) (Note :- Contractor shall ensure that the fittings repaired shall be made serviceable for the entire period of contract within a period of 06 hours o intimation by EIC. however payment under this item shall be made only once a time during the period of contract).
Supply and fixing CFL 18 watts cross pin suitable for CFL fittings 1x18/2x18 watts of make Bajaj/CG or equivallent to other specified make.
MCCB FP,adjustable type ,415 Volt , 160 Amps,with breaking capacity 36 KA Make Legrand or equivalent ABB make.
MCCB FP,adjustable type ,415 Volt , 250 Amps,with breaking capacity 36 KA Make Legrand or equivalent ABB make.
MCCB FP,adjustable type ,415 Volt , 200 Amps,with breaking capacity 36 KA Make Legrand or equivalent ABB make.
Supply and fixing only Open construction ballasts 250 SV/MH of Bajaj or equivalent of other specified make suitable for HPSV/MH fittings complete including making connections all as specified.
Supply and fixing Open construction ballasts 150 SV/MH of Bajaj or equivalent of other specified make complete all as specified.
Supply and fixing Open construction ballasts 400 SV/MH of Bajaj or equivalent of other specified make suitable for HPSV/MH fittings complete including making connections all as specified.
Fixing only 250 watt universal burning Metal Halide Lamps (MH), elliptical shaped, clear metal halide lamp with ES cap suitable for HPSV ballast with ignitor, 220 to 240 Volts, 50 Hz AC supply complete all as specified.
Supply and fixing 400 watt universal burning Metal Halide Lamps (MH), elliptical shaped, clear metal halide lamp with ES cap suitable for HPSV ballast with ignitor, 220 to 240 Volts, 50 Hz AC supply complete all as specified.
Supply and fixing 150 watt HPSV lamp, elliptical shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz AC supply complete all as specified.
S&F in repairs 500 watts Halogen lamps, double ended quartz glass clear linear shaped, with Rx7s base Cap complete all as specified.
S&F in repairs 1000 watts Halogen lamps, double ended quartz glass clear linear shaped, with Rx7s base Cap complete all as specified.
S&F (in repairs) electronic transformer 240 V suitable for 1x12V, 50 watt halogen lamps, all as specified and directed.
S&F in repairs CFL ballast suitable for 1x18 watt or 1x 11 watt fittings of make Bajaj or equivalent of other specified make.
Supply and fixing ignitor of non integral (upto 30 mtr ) suitable for HPSV of 70 watt to 400 watts HPSV/MH fitting complete including making connections all as specified. Make Havells/Bajaj/CG.
Supply only LED bulb warm white 2 pin wattage 10 watt 220 volt 50 hz complete all as specified and directed
Supply only LED bulb cool white 2 pin wattage 10 watt 220 volt 50 hz complete all as specified and directed
Supply only brass holder for normal CFL /bulb 220 volt 50 hz complete all as specified and directed
M & L for repairing and servicing two pole/Four pole structures comprising of following works :- (a) Dismantling the ACSR jumper connection from Air break Gang operated drop out fuse end lighting arrestors etc from the two poles structures, replacing the complete jumpers in to new with ACSR conductors including PVC coloured sleaves and connecting with suitable thimbles connections/binding/PG clamps etc all as specified and directed by Engr-in-charge. (b) Removing the complete rusted bolts, nuts and washers and replacing with new bolts, nuts and washers. (c) Disconnecting the Air Break switch knives cleaning and servicing by lubricating the moving parts terminals with petroleum jelly. (d) Cleaning the exposed surfaces of two pole structure complete and painting with two coats of synthetic enamel alum paint all as specified and directed by Engr-in-Charge
All as per item No 143 above but here in for four pole structures.
Supply and installation of advance encapsulated compound based CPRI tested maintenance free, pipe in pipe technology upgraded (Zinc and alloy coated, Zinc coated (80-100) microns, earthing system conforming to IS 3043-1987 and subsequent amendments. The outer and inner pipe shall be 76.2mm dia and 41.9mm dia, 3m length, Zinc coated with additional special alloy coating 300mm on the top side for additional corrosion protection of the terminal. The annular between the pipes being filled up with compact fill (CF) (crystalline conductive compound). The compact fill (CF) mixture which is machine pressed in the pipe shall not disintegrate or collapse when outer pipe corrodes. The inner pipe shall be extended with terminals for connectivity. The job include digging the pit and refilling the same by electrolyte/conductolite back fill compound (ground enhancer), the BFC shall be ecofriendly it should not contain environmentally hazardous material/metal having RoHS certification from NABI, accredited lab. The earth pit shall be provided with FRP earth pit covered for protection and safe guard of terminals. Good black cotton soil shall be arranged to refill the excavated pits by mixing the same with BFC 3 bags per pit. The materials shall be of good electrical conductivity and anticorrosion property with in wide range of soil condition. Make ASHLOK Model ASEEL-39-3M Length (ZC and AC)/JMV. Note: Earth testing shall be done and recorded in presence of Engr-in-Charge.
S&F outdoor Epoxy straight through joint to LT XLPE/ PVC insulated cable including all accessories and connection for 120 sq mm to 150 Sq mm 3 1/2 core and 4 core cable all as specified (Excavation, earth work, sand cushioing, bricks shall be measured andpaid separately).
All as per item No 146 above but 50 sq mm to 95 Sq mm 3 1/2 core and 4 core.
Supply and replaced MCB TP , C - curve - 10 ka , 6 - 32 Amps all as per Legrand Cat no 6032 82 to 71 or equvalent of L&T / Havells .
Supply and replaced MCB TPN four pole, 100 Amps all as per Legrand Cat no 6032 89 to 91 or equvalent of L&T / Havells .
Taking down carefully Gang operated air break switch 11 KV, 200 Amps rating from HT poles by disconnecting all electrical connection for carrying out repairs, spliting / opening and renewal of burnt out/ defective parts and fixing after proper oiling and greasing of movealble parts and renewal of nuts, bolts washers and S&F suitable size of SC PVC insulated jumper wire 3.00 M long of 70 Sqmm aluminium conductor cable complete all as specified (Spares parts renewed as listed below shall only be measured and paid separately under appropriate items).
Supply only porcelain brown or white or green Post insulator suitbale for HT 11 KV Gang operated device.
Supply only CP MS Male moving Contact blade suitable 11 KV Gang operated device.
Supply only CP Ms female contact / fixed Contact jaq suitable 11 KV Gang operated device.
Supply only tinned copper flexible jumpers suitable for 200 Amps rating 11 KV Gang operated device.
Supply and fixing (in repairs) Galvanised mild steel pipe /tubing, light grade 80 mm complete with alll fittings, laid in trenches. Under roads, drain, paths, fixed to poles/walls with mild steel clamps, bolts nuts and washers complete all as specified of the following bore (Excavation & Earth work, Mild steel clamps, bolts, nuts and washers shall be measured and paid separately).
Supply laying or fixing jointing and testing LT under ground electric power cable crossed plyethylene (XLPE) insulated, two or more core, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded, heavy duty 1100 Volts grade of 120 SQMM 3.5 core sizes complete all as specified laid in trenches/ laid under floor or fixed naked with maked walls / on ples / in ducts /in GI pipes etc. (Excavation, earth work, sand cushioning, protection bricks/tiles/block, clamps, nuts, bolts, washers and pipe shall be measured and paid separately under appropriate items).
Shree Tirupati Associates
M/S AMARJIT SINGH
m/s pal associates
Ajanta Associates
Ajanta Motor Store
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .