Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.6 LAccepted-AOC HOSPITAL ROAD OPP VIPUL GAS AGENCY SOLAN HP 173212 | SOLAN | SOLAN | HIMACHAL PRADESH | 173212 | 1 | Accepted-AOC L-1 | |
| 2 | 2₹17.8 L+₹1.6 L (9.75%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹18.1 L+₹1.8 L (11.4%)Rejected-Finance | 3 | Rejected-Finance L3 | |
| 4 | 4₹18.7 L+₹2.5 L (15.5%)Rejected-Finance GROUND FLOOR PRAKASH APARTMENT BYE PASS ROAD SAPROON SOLAN SAPROON SOLAN SOLAN HIMACHAL PRADESH 173211 UDYAM HP 11 0005662 | SOLAN | HIMACHAL PRADESH | 173211 | 4 | Rejected-Finance L4 |
Tender Value
₹11.4 L
EMD Value
₹22,800
Closing Date
19 Jun 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
JSV Division Jubbal
Construction of LWSS Saskir Solang in GP Solang Tehsil Jubbal Distt Shimla HP
2020_HPIPH_37999_1
JBL-SML09-718
Open Tender
Civil Works - Others
Item Rate
90 days
Solang Saskir
Please refer Tender documents.
7 documents required · 7 mandatory
₹400
EE Jubbal
₹22,800
Yes
14 Aug 2020
10 Jun 2020
19 Jun 2020
10 Jun 2020
19 Jun 2020
10 Jun 2020
120 days
Amount
Supply of horizontal spindle,horizontal split casing Single/Multistage centrifugal pumps of standard make such as KSB/ Mathar & Platt/ Jayoti/ Kirloskar confirming to BIS 1520-1980 (latest with upto date ammendments) read with BIS 9137-1978 or latest to handle raw water having turbidity 50 ppm. with impelleres,casing ring & shaft sleeves of bronze, shaft of steel with cast iron casing of suitable capacity coupled directly through a flexible coupling on a common base plate to Kirlokar/NGEF/Crompton/ Siemen/Jyoti slip ring/squirrel cage screen protected drip proof electric induction motor suitable for operation on the data given below. (Site Conditions as per Annexture A).
Supply of suitable oil immersed star delta starter/ATS/stator rotor starter of standared make such as MEI/Kilburn/Jyoti/Siemens conforming to BIS-8544-1979 leates with up to date ammendments for squirrel cage/slopring motor(make to be specified by the tenderers) mounted on panel board with magnetic type over load release & dashpot, time lag , under voltage release wfith initial oil filling. Note:- Star - delta - starter upto 37.5KW , ATS between 37.5KW to 50KW and stater rotor starter with slipring motor beyond 50KW.
Providing M.S Sheet 16 SWG steel fabricated floor mounted closed almirah type switch board including angle iron post of suitable height and size ISA 40x40x6mm duly painted comprising and capable of mounting the following accessaries with all internal electric connections. The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses Kilburn/Larsen & turbo/Standard/Siemen make and having capacity 30% extra of the operational rating of motor as BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.
Busbar chamber having 3 copper bars of suitable rating for full length equal to wirdth of board of 3 live phases and one copper bar of half reating of full length for neutral conforming to BIS 8084-1976 and 11353-1985 read with 5578-1985 all latest with upto data ammendments.
MCB/Oil circuit breaker of suitable capacity of Kilburn/LT/LK/MEI/Standard make on in coming feeder for motors offered by the tenderer conformaing to BIS 2516-1985 latest with upto date ammendments with neutral linked under voltage release.
3 phase indicating lamps complete with toggle switches for individual motors conformaing to BIS 3452 part I & II latest with up to date ammendments.
Earth leakage circuit braker of requcemended (Kilburn/L&T/MET/GEC as per BIS-2516-1977 with upto date ammendments and of suitable range with which should have control box , oprating handel and trip/rest bush button / off indicators, re-indicating off spring condition of the circuit braker for over current protection. The curcuit should be equipped with magnet thermal release with metallic tap CTS. It should also be fitted earth fault for trippping of breaker on occurance of earth fault on/of braker load side.
Hour run meter of reputed make of digit capacity conforming to BIS-722(latest edition)/recommendation.
Suitable three phase voltage monitor relay with all protections & usual indicators with electrical sirens against single phasing, no voltage, high voltage & overloading & phase voltage difference
Change over Switch of reputed make & suitable capacity.
Single phase preventor of reputed make & suitable capacity.
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/Gled/BHEL/Leader/of reputed make of suitable size cast iron /cast steel double flanged sluice valve having size equal to delivery of pump and capable of with standing nominal seat pressure of 52kg/cm^2. NOTE:- The sluice valve shall conform to BIS 780-1984 latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 780 then the sluice valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2) as per BS 1414(API 600).
Supply of Kirloskar /Kilburn /IVC/ Fouress/ Gled/BHEL/Leader/of suitable size cast iron /cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to delivery of pump for withstanding nominal seat pressure of 52Kg/cm/^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/ Kilburn/ IVC/ Fouress/ Gled.BHEL/Leader of suitable size cast iron/Cast steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of R/Main i.e of R/Main i.e 1.50.mm for withstanding nominal seat pressure of 52Kg/cm^2. NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be cast steel conforming to class 150 ASA (Seat pressure 231Kg/cm^2) or class 300 ASA (seat pressure 52Kg/cm^2)) as per BSI 1414 (API 600).
Supply of Kirloskar/Jyoti/Standard/Kilburn make cast iron flanged screwed type foot valve with strainer of dia equal to dia of suction pipe conforming to BIS 4038-1986 or latest with up to date ammendments. OR Supply of Kirloskar/Jyoti/Kilburn/IVC/Kartar/leader /BHEL make cast iron flanged sluice valve having equal to dia of suction pipe capable of withstanding normal seat pressure of 52 kg/ cm2 conforming to BIS 780-1984 with up to date ammendments in case of positive suction.
P/L suitable size copper PVC insulated armoured power 3 1/2 core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/Gloster/ICC make from meter of HPSEB to OCB & from OCB to Busbar switch & starter(one cable carrying all three phases) including all other electrical equipment/ accessories such as thimbles,flexible pipe, solder,nuts & bolts,cable glands etc. laid in pipes or trenches under floor.The type,size & make will be subject to aproval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost ..
P/L suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554(Part I)-1988 or latest with up to date ammendments Siemen/ Gloster/ ICC make from switch to starter & starter to (one cable for carring all three phases) including all other electrical equipment/ accessories such as thimbles, flexible pipes, solder,nuts & bolts, cable glands etc. laid in pipes or trenches under floor. The type ,size & make will be subject to approval of HPSEB athorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tender free of cost .
P/L double loop earthing with copper plate 600x600x3mm thick electrode complete with material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, GI wiring & 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with up to date ammendmentsfor above motors & other electrical equipment.
Supply & errection of floor/wall mounted power factor capacitor conforming to BIS 2834-1986 latest with upto date ammendment BHEL/ GEC/ Machneil/ Masger/ Bajaj make to raise the pervailing power factor at site to 0.95 for direct connection to induction motor individually, or requird KVAR according to Himachal Pradesh of motor offered including cable siemens/ Gloster/ICC make from busbar chamber to capacitor & also including LT/LK/Kilburn make ICTP switches conforming to BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer.
Supply of standard make 100mm dia circular dial pressure of suitable range Fiebeg/ Bourden/Precision make with all accessories such as stop cock, copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L suction,delivery pipe considering site requirements , NPSH reqired & available & common header having area equal to times the area of delivery branch of pump including tapers, flanges, rubber gaskets, 3mm thick as per BIS-2712-1978 nuts & bolts as per 1364-1983 & special up to 5 mtrs. Away from the outer wall of pump house as per layout drawings approved by Engineer-in Charge The pipes shall be capable of withstanding 1.5 times the total presure indicated in item no. Ie(ii). BIS 4064-1978 or latest with HRC fuses (Range to be specified by the tenderer. NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Supply of antivibration pads conforming to BIS 6337-1971 or latest with up to date ammendmentsof suitable size for above machinery.
Errection of all equipments from S.No. 13 to 16, 18 & 20 i/c cost of tees, bends tapes &any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Supplying & Fixing of Oil Circuit breaker 250 ampare ISI marked for 75 HP Pumping Machinary with all leads & Lifts complete.
Providing & Fixing DOL star delta starter of 75 HP complete in all respects
Providing & Fixing New MCDB of 63 ampare complete in all respects
Providing & fixing New Kitkat 500 ampare complete in all respects.
Providing & fixing 3 core copper cable 6 mm thick complete in all respects.
Providing & fixing finger contact (big) for 75 HP MEI starter in all respects.
Providing & fixing no volt coil for starter complete in all respects.
Providing & fixing Nuts & Bolts 350,400,500 mm 20 pin each with washers complete in all respects.
Providing and fixing Champion sheet complete in all respects.
Supplying of transformer oil pure standard quality complete in all respects.
Providing and fixing gland dori 8 mm complete in all respects.
Providing and fixing of volt metre complete in all respects
Supplying of lubricant oil pure standard quality complete in all respects.
HYDRAULIC ENGINEERING COMPANY
Thakur Traders
Sai Aqua Machines and Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .