Loading…
Loading…
Tender Value
₹2.0 Cr
EMD Value
₹4.1 L
Closing Date
3 Jul 2026, 5:30 am
Avionics Division, Hyderabad
Avionics Division, Hyderabad
ELECTRICAL WORKS FOR UP-GRADATION OF GCA BUILDING
25839
HAL/HD/MT/CT/26-27/4
Limited
Works
Accessories Complex- Avionics Divn-Hyderabad-Plant Maintenance
| # | Company Name | Location | Address |
|---|---|---|---|
| 1 | K G R K ENGINEERING SERVICES | HYDERABAD,India | 11-4-892,MAIN ROAD,CHILKALGUDA,SECUNDERABAD,HYDERABAD,Andhra Pradesh,India,Pin-500061 |
| 2 | RPandu Rangam Sons | hyderabad,India | 1 8 37C,BESIDE AURORA COLLEGE LANE, CHIKKADPALLY,HYDERABAD,,hyderabad,Andhra Pradesh,India,Pin-500020 |
| 3 | SEECUBE ASSOCIATES | Hyderabad,India | Plot No 113,2RT Beside Watertank Play Ground S.R.Nagar Hyderabad.,Residence Flat No 202 SA Plaza Rajive Nagar Hyderabad.,Hyderabad,Andhra Pradesh,India,Pin-500038 |
| 4 | Sabari Electric Company | Bangalore,India | No. 42, CMH Road,Indiranagar 2nd Stage,Bangalore,Karnataka,India,Pin-560038 |
K G R K ENGINEERING SERVICES
HYDERABAD,India
11-4-892,MAIN ROAD,CHILKALGUDA,SECUNDERABAD,HYDERABAD,Andhra Pradesh,India,Pin-500061
RPandu Rangam Sons
hyderabad,India
1 8 37C,BESIDE AURORA COLLEGE LANE, CHIKKADPALLY,HYDERABAD,,hyderabad,Andhra Pradesh,India,Pin-500020
SEECUBE ASSOCIATES
Hyderabad,India
Plot No 113,2RT Beside Watertank Play Ground S.R.Nagar Hyderabad.,Residence Flat No 202 SA Plaza Rajive Nagar Hyderabad.,Hyderabad,Andhra Pradesh,India,Pin-500038
Sabari Electric Company
Bangalore,India
No. 42, CMH Road,Indiranagar 2nd Stage,Bangalore,Karnataka,India,Pin-560038
₹0
₹4.1 L
5 Jun 2026
5 Jun 2026
5 Jun 2026
3 Jul 2026
REMOVAL OF ITEMS: Removal, Dismantling, Shifting & Handing over of Cable terminations, PVC / MS conduit pipes with wiring, Cables,LT,HT panels, Switch Boards, Switch Socket Boards, Tube light fittings with down rods etc. as per the direction of in charge engineer. The removal and shifting shall be done for above materials with all accessories complete.
POINT WIRING Lights/Fans/exhaust : Supply & fixing of following light points etc with 2 runs of 1.5 sq. mm FRLS PVC insulated flexible copper conductor 1.1kV grade concealed suitable diameter PVC Conduit pipe of 2 mm thick/PVC concealed including supply & fixing of 10 Amp @ 250V AC SP Modular switches of approved quality, color & design with 2 mm thick G.I/PVC modular box including inner plates and outer plates, concealed in wall and inter connection complete.2 Light points controlled by one 5 / 10 A modular type SP switch Make: Legrand/Siemens/L&T/GE. Make: Pllycab / fincab / Finolex /Gloster
Providing of LED Light Fixtures: Supply, installation, testing & commissioning of Recessed Mounted 2 X 2 ft (36-40) watt LED Full out put Luminaries with CRCA power coated With high diffuser efficiency of 3600 lumens with necessary fixing accessories as per site & inter-connection complete Make: philips / CGL / Wipro
Procisioning Emergency LED : Supply and Provision of (12-18) Watt Emergency LED cirular/Square recess / surface mounted fittings as per direction of EIC: Battery capacity should be minimum of 2200 mAH & Lighting back up time will be minimum 2 hours Makes: Havells/Crompton/Philips/ Orient/ Wipro/ Bajaj / FA / Ever ready
PROVIDING OF LED LIGHT LUMINAIRE: Supply & Fixing of 4 feet 2*20 Watt, Industrial batten with two numbers Industrial LED Tube lights on wall with necessary accessories. make : Philips/Wipro/CGL
Wall mount fans: Supply and provisioning of wall mount fans on existing wall , 400mm sweep, 5 star rated with all inter connections & all fixing accessories as per site condition and as directed by EIC. Make: Crompton / Havells / Orient / Usha / Atomberg
BLDC ceiling fans: Supply and provisioning of BLDC ceiling fans, 1200mm sweep, 5 star rated on existing roof with electronic Regulator, downrod of required length as per site condition and all fixing accessories as directed by EIC. Make: Crompton / Havells / Orient / Usha / Atomberg
POWER WIRING: Providing and laying of 2 runs of 2.5 sq mm and 1 runs of 1.5 sq.mm 1100 volt grade FRLS PVC insulated flexible copper conductor with suitable dia PVC conduit conductor flexible wire for power / sub mains with suitable size 2 mm thick PVC conduit with bends, special junction boxes laid concealed / on existing cable trays / on the surface with suitable fixing clamps, ceiling roses, nuts, bolts with crimping lugs at DB and Switch termination and inter connection complete etc as per site. The scope also includes wiring of the testing tables without conduit for different power supplies in the existing trunking. Make: Pllycab / fincab / Finolex /Gloster
POWER WIRING: Providing and laying of 4 runs of 4.0 sq mm and 2 runs of 2.5 sq.mm 1100 volt grade FRLS PVC insulated flexible copper conductor with suitable dia PVC conduit conductor flexible wire for power / sub mains with suitable size 2 mm thick PVC conduit with bends, special junction boxes laid concealed / on existing cable trays / on the surface with suitable fixing clamps, nuts, bolts with interconnections complete.. Make: Pllycab / fincab / Finolex /Gloster
POWER WIRING: Providing and laying of 4 runs of 6.0 sq mm and 2 runs of 4 sq.mm 1100 volt grade FRLS PVC insulated flexible copper conductor with suitable dia PVC conduit conductor flexible wire for power / sub mains with suitable size 2 mm thick PVC conduit with bends, special junction boxes laid concealed / on existing cable trays / on the surface with suitable fixing clamps, nuts, bolts with interconnections complete.. Make:Pllycab / fincab / Finolex /Gloster
POWER WIRING: Providing and laying of 4 runs of 10 sq mm and 2 runs of 6 sq.mm 1100 volt grade FRLS PVC insulated flexible copper conductor with suitable dia PVC conduit conductor flexible wire for power / sub mains with suitable size 2 mm thick PVC conduit with bends, special junction boxes laid concealed / on existing cable trays / on the surface with suitable fixing clamps, nuts, bolts with interconnections complete.. Make: Pllycab / fincab / Finolex /Gloster
Providing of Independent Modular Sockets & Switches for computers : Supply and fixing of following items with 2 mm thick GI modular box independent concealed in the wall with inter connection complete. 3 No, 6 Amp 3/2 pin multiple universal socket controlled 3 no.6 Amp switch each & 1 No, 16Amp 5 pin multiple universal socket controlled one no.16 Amp switch a. Make: Legrand/Siemens
PROVIDING OF MODULAR TYPE IN-DEPENDENT SWITCHES & SOCKETS: Supply and fixing of 2 Nos 16 amps 5 pin multiple socket controlled by 2 No.16 amps SP MODULAR switch of approved quality, color & design shall be mounted on suitable cover plate with suitable MS box with inter connection complete as per site requrement.The box shall be mounted on concelled/ surface of wall / floor with all requred ccessories as per site condition. Make:Legrand / Seimens
MCCB / MCB DISTRIBUTION BOARD Supply, Installation, testing and commissioning of the following factory made MCB / MCCB Distribution Boards (Double door type) IP-54 Cubicle / Enclosure made of 1.6 mm thick CRCA sheet steel, powder coated with approved shade and partitions to segregate phases with suitable 2 Nos of top & bottom cable entry end boxes. The DBs & Cable entry end boxes shall be mounted recessed / surface mounted on wall with suitable iron angle frame & all fixing accessories as per site and inter connection with number sleeves & crimping lugs complete. The rate shall include supply & fixing of 2 Nos (top & bottom) cable end boxes suitable for following DBs.make: Legrand, Note: Scope includes cable end terminations at PDBs with all interconnections as per direction of EIC POWER DB 8-Way 4P MCCB DB Incomer:. 1 No,250 A 4POLE (Icu=36 Ka) MCCB Out going: 12 Nos, 16A ( Type 'C') SP MCB 04 Nos, 30-63A A ( Type 'C') TP MCB,
MCCB / MCB DISTRIBUTION BOARD Supply, Installation, testing and commissioning of the following factory made MCB / MCCB Distribution Boards (Double door type) IP-54 Cubicle / Enclosure made of 1.6 mm thick CRCA sheet steel, powder coated with approved shade and partitions to segregate phases with suitable 2 Nos of top & bottom cable entry end boxes. The DBs & Cable entry end boxes shall be mounted recessed / surface mounted on wall with suitable iron angle frame & all fixing accessories as per site and inter connection with number sleeves & crimping lugs complete. The rate shall include supply & fixing of 2 Nos (top & bottom) cable end boxes suitable for following DBs.make: Legrand. Note: Scope includes cable end terminations at PDBs with all interconnections as per direction of EIC POWER DB 8-Way 4P MCCB DB Incomer:. 1 No,125 A 4POLE (Icu=36 Ka) MCCB Out going: 04 Nos, 30-63 A ( Type 'C') TP MCB 12 Nos, 16 A ( Type 'C') SP MCB
COPPER PLATE EARTHING:Making Earth pit complete with copper plate 60 cm x 60 cm x 3.15 mm thick electrode and 25 mmx3 mm copper strip. Copper plate is to be buried directly in ground with top edge of the plate not less than 3.0 metres below normal ground level. Copper strip to be bolted with the earth plate at three points by means of copper bolts, nuts, check nuts and washers. Earth strip to be extended upto earth test point in earth chamber at ground level. Scope of work includes excavation of earth & refilling, drilling hole to electrodes, supply and covering the earth plate with alternate layer of salt and charcoal (not less than 15.0 cm on both side of plate), PCC pit and CI cover, Funnel with watering pipe, wire mesh and copper lugs etc as specified, GI protection pipe of size as specified for protection of earthing lead from top of earth plate upto earth chamber, laying copper strip of length of 5.0 mtrs connecting from test point to mainswitch or switch board or equipment and any other work necessary to complete making earth pit in all respect. Note: Earth resistance to be achived 0.5 ohms by connecting all eartpits as grid as directed by EIC
COPPER EARTH STRIP:Supply & laying of 25 mm x 5 mm Copper Strip on porciline insulators clamped to walls at distance of one meter or on cable trays, run in pipes, run underground etc., as required including interconnection between the earth stations etc., complete as required conforming to IS: 3043-1987. Scope of work includes supply of calmping materials necessary to complete work in all respect as per direction of EIC.
GI pipe earthing: Making Earth pit complete with GI pipe 100m dia length 2.75mtr. GI pipe to be buried directly in ground with top edge of the pipe not less than 3.0 metres below normal ground level. GI strip of 32mmx6mm to be bolted to GI pipe by means of bolts, nuts, check nuts and washers. Earth strip to be extended upto earth test point in earth chamber at ground level. Scope of work includes excavation of earth & refilling, supply and covering the GI pipe with alternate layer of salt and charcoal (not less than 15.0 cm on both side of plate), PCC pit and cover, Funnel with watering pipe, wire mesh and lugs etc as specified and any other work necessary to complete making earth pit in all respect as per site requirement.
GI STRIP :Supply & laying of 25 mm x 5 mm GI stip on porciline insulators clamped to walls at distance of one meter or on cable trays, run in pipes, run underground etc., as required including interconnection between the earth stations etc., complete as required conforming to IS: 3043-1987. Scope of work includes supply of calmping materials necessary to complete work in all respect as per direction of EIC.
LT CABLING: Supply & laying of 3.5 core x 120 SQMM Aluminium conductor armoured cable of 1100 V grade existing trench under ground trenches available or on surface of the wall / cable tray by supplying all required fixing accessories as per site condition as directed by the EIC. scope includes cable end terminations with suitable glands. Make:Universal (Unistar) / CCI / Gloster/ Nicco / Finolex
LT CABLING: Supply & laying of 3.5 core x 240 SQMM Aluminium conductor armoured cable of 1100 V grade existing trench under ground trenches available or on surface of the wall / cable tray by supplying all required fixing accessories as per site condition as directed by the EIC. scope includes cable end terminations with suitable glands. Make:Universal (Unistar) / CCI / Gloster/ Nicco / Finolex
LT CABLING: Supply & laying of 3.5 core x 70 SQMM Aluminium conductor armoured cable of 1100 V grade existing trench under ground trenches available or on surface of the wall / cable tray by supplying all required fixing accessories as per site condition as directed by the EIC. scope includes cable end terminations with suitable glands. Make:Universal (Unistar) / CCI / Gloster/ Nicco / Finolex
Provision of MCCB with Encloser: Supply fixing, testing and proving of 4 pole 400A rated industrial MCCB with suitable metal enclouser. The MCCB box shall be concealed / mounted on surface of the wall/ pillar or on suitable iron angular frame as per site requirement, including grouting materials such as cement for patch works complete. Make:Legrand /Seimens
THREE PHASE INDUSTRAIL SOCKET:Supply fixing, testing and proveing of 4P,63A MCB with encloser as per site requirement for "Equipments" power supply. The boards shall be mounted on surface of the wall/ pillor or on suitable iron amgular frame as per site requrement, including grouting materials such as cement for patch works complete. Make:Legrand / Havells / L&T.
32A MCB ENCLOUSER: Supply fixing, testing and proving of 4 pole 32A rated industrial MCB with suitable metal enclouser. The MCB box shall be concealed / mounted on surface of the wall/ pillar or on suitable iron angular frame as per site requirement, including grouting materials such as cement for patch works complete. Make:Legrand /Seimens
63A MCB ENCLOUSER: Supply fixing, testing and proving of 4 pole 63A rated industrial MCB with suitable metal enclouser. The MCB box shall be concealed / mounted on surface of the wall/ pillar or on suitable iron angular frame as per site requirement, including grouting materials such as cement for patch works complete. Make:Legrand /Semens
Exhaust Fans: Supply and fixing of 9 inch exhaust fan on existing wall with louvers & with necessary accessories as per direction of EICs Make: CGL / Usha / Almonard. Scope includes provisioning of suitable dia hole on wall to provisioning fan.
IN DOOR 12 KV VCB PANEL(5 Nos HT VCBs) : Design, Fabrication, Assembly, Internal wiring, Installation, Testing & Commissioning of Vertical type free standing floor mounted powder coated H.T. VCB Panel set with 5 Nos 12KV, 800A,25KA HT VCBs for accomodating motorized/ manual horizontal drawn type VCBs with mechanical and electrical inter lock provision (With 2 nos. Incommers, 1 nos Bus-couplers, 2 nos Outgoings ), Incomig should have CT ratio 600-400/1-1-1A,remaing VCBs of 400/1-1A. PTs as per requirements. each breaker provided with 5 Nos relays (two for LL faults, each for earth fault, auxilary and master trip) and indicating lamps and digital meters suitable for measuring voltage, current, power factor and energy consumed and also suitable for computerised on line parameters monitering system . Multi function meter with Modbus protocal of RS232/RS485 .The panel shall be compartmentalized in design and made up of 14 SWG CRCA Sheet steel with 3mm thick cable entry gland plates at the bottom and fixing all aggregates with stainless steel hard ware. The panel shall be treated with all anti-corrosive process before powder coating & 2 nos earthing terminals as per IS 3043. The degree of ingress protection for the panel shall be equivalent to IP-54 conforming to IS-13947 (Pt-1). All panel doors and covers shall be provided with suitable compressible neoprene gaskets for high degree of ingress protection against dust, dirt, moisture, insects etc.PDI inspection to arranged by vendor. VCB Make:Crompton Greaves Ltd / Schinder / Siemens. note: the relays should be dual fiber port with PRP with drawout relays Make: Ashida ADR 241B-B-2 / Scheneider /seimens.
Automatic clean agent flooding system (1 nos HT panel for Schedule Sl No 28) : Supply, installation, testing and commissioning of automatic clean agent flooding system for electrical panel as per required with fire finder tube, cylinder, valves.The system should include audio visual announcement system along with sim based alert. The alarm system should have provision to integrate with the existing Fire alarm system of the HAL. Regularity requirement like NFPA ,National elctric code SP 30 : 1985, system agent should be as per IS 15946:2004."
LT MAIN POWER DISTRIBUTION PANEL: Design, Fabrication, Assembly, Internal wiring, provisioning in place of old panel, Testing of vertical type floor mounted powder coated L.T. Panel made of 14/16 SWG CRCA Sheet (IP-54) as per site condition and bring to HAL site after PDI at manufacture site. The panels shall be suitable for medium voltage L.T. distribution with required digital MFM & 3 nos indication lamps. Aluminium bus bars of size suitable for 2500 Amp rating duly marked Red, Yellow, Blue for phases & 1 No Black for neutral of rating 1250 Amps with heat shrinkable sleeves and mounted on cast resin supports / moulds. The panel shall be treated with all anti-corrosive process before powder coating & 2 nos earthing terminals as per IS 3043. The degree of ingress protection for the panel shall be equivalent to IP-54 conforming to IS-13947 (Pt-1). All panel doors and covers shall be provided with suitable compressible neoprene gaskets for high degree of ingress protection against dust, dirt, moisture, insects etc. Note: Drawings approvals and panel diamentions to be taken from site as directed by EIC. Multi function meter: Digital meter with measurement of (Voltage, Current & Frequency, Power Factor, Power & Energy with RS 485 ) Make: Secure. . Incomer : Provision for 1 Nos of 2500A ACB. Out Goings :2 Nos 2000 ACBs, 3Nos of 630A MCCBss, 6 Nos of 250A MCCB, 6 Nos of 160A. MCCB, Bus bars of 3000A with suitable rating earthing , GI Earth: 36 mm x 6 mm. for panel grounding s,.Multifunction Digital meter with measurement of (Voltage, Current & Frequency,Power Factor, Power & Energy with RS 485 ), ACB Make: Legrand / Schneider / Siemens, MCCB Make: Legrand as specified and as directed by EIC Note: Scope includes cable end terminations at LT panel incoming and outgoings with all interconnections as per direction of EIC
1000KVA Transformer Servicing: Servicing/overhauling of 01 Nos 11KV/430V transformer,scope includes:- i) Collecting the transformer from HAL to work shop. Checking the megger values, opening of transformer, Removing of winding along with lamination core set from oil and drying it in oven, testing the values, draining of oil to other tank, cleaning the tank, reinstallation of winding set and lamination back into the transformer body, Replacement gasket, necessary hardware, etc., as required and refixing. Filtaration of oil(oil vendor scope) , replacement of silica gel bottles, Scope includes provisioning of transormer oil top up with proper filteration. two coates of Enamil Painting of transformer after applying red oxide After all necessary testings, installing the transformer at site with all HT terminations and proper earthing connections
Provisioning of RTCC panel: Supply and provisioning of wall mounted /Floor mounted RTCC panel for tapchanging of existing 11KV/0.440V , 1000 KVA transformer with all cable comnnections from transformer to RTCC panel, control cable is contractor scope.
Provisioning of HT cable: HT CABLING: Supply & laying of 11KV 3 core x 300 Sq mm earthed armoured cable with stranded compacted circular Aluminium conductor,conductor screened with extruded semiconducting compound, XLPE insulated ,insulation screened with extruded semiconducting compound in combination with copper tape ,conforming to IS:7098 std ,cable laying in under ground trenches from 33/11KV substation at township to factory indoor sub stations as per site condition as directed by the EIC. Note:scope includes provisioning of straight through joint kits for cables as per site requirement Make:Gloster/Finolex/Polycab/ KEI, Note: Scope includes straight through joints if necessary between cables.
Provisioning of HT cable: HT CABLING: Supply & laying of 11KV 3 core x 185 Sq mm earthed armoured cable with stranded compacted circular Aluminium conductor,conductor screened with extruded semiconducting compound, XLPE insulated ,insulation screened with extruded semiconducting compound in combination with copper tape ,conforming to IS:7098 std ,cable laying in under ground trenches from 33/11KV substation at township to factory indoor sub stations as per site condition as directed by the EIC. Note:scope includes provisioning of straight through joint kits for cables as per site requirement Make:Gloster/Finolex/Polycab/ KEI
Cable tray: Supply and provisioning of 100 mm *50mm*1.6mm thickness perporated closed cable tray with bends for roting cables on wall with all fixing accessories as per site requirement
BRICK WORK &TRENCH PREPARATION:Providing and constructing brick work with digging for 1Cu .mtr best locally available frogged bricks in CM 1:6 for walls at all levels and for all thickness in standard bonds including raking out joints 10mm deep to receive plaster, chipping of existing brick walls / concrete surfaces where ever new walls are meeting in order to arrest cracks, applying cement slurry before constructing wall to have proper bond, necessary scafolding, curing etc., complete as specified and directed by EIC.
TRENCH MAKING: Excavation of all kinds of earth up to a depth of 1000mm x 300mm with laying of Double walled corrugated (DWC) HDPE duct made as per specifications IS 14930 part- II of suitable dia mm for 300 sq mm HT cable( OD=160mm & ID=135mm dia & above suiatable ) in above trench with proper DWC Coupler interconnection to enable to replace the laid cable in future if necessary as per ste condition and instruction of EIC. Make:Duraline(Dura guard) / CPE / Telerex. Colour: Orange over the cable as directed by EIC . The dug earth should be refilled after cable routing executing the work.
TRENCH MAKING: Excavation of all kinds of earth up to a depth of 600mm x 300mm with laying of Double walled corrugated (DWC) HDPE duct made as per specifications IS 14930 part- II of suitable dia mm for 300 sq mm HT cable( OD=165mm & ID=135mm dia & above suiatable ) in above trench with proper DWC Coupler interconnection to enable to replace the laid cable in future if necessary as per ste condition and instruction of EIC. Make:Duraline(Dura guard) / CPE / Telerex. Colour: Orange over the cable as directed by EIC . The dug earth should be refilled after cable routing executing the work.
ROAD CUTTING& Hume pipe: Road cutting and excavation of all kinds of earth upto 600 mm depth x 300 mm width The earth should be refilled after executing the work and is to be plastered with cement concreate of 150mm depth from the surface completely with good finishing as per the site requirement and the direction of the engineer in-charge.Scope includes provision suitable diameter half circular humepipe over the cable routong as directed by EIC
11 KV HT IN DOOR END TERMINATIONS: Supply and making of heat shrinking / end joint kits suitable for 11000 Volt grade 185 Sq.mm to 300 Sq.mm PVC/XLPE insulated aluminum conductor armoured cables including supplying and fixing of required crimping lugs, glands, Aluminium sockets etc. as per site requrement. The scope also includes making of end termination after making end joint kit. NOTE:-Crimping shall be done with hydralic crimping tool.Make:3M/Denson/Rechame
PROVISION OF ROUTE MARKERS:Supply and fixing of HT cable route markers.The route marker should be fixed to MS angular channel of thickness 5mm of size 40mmx40mm of length 450 mm.The channel shall be grouted approximately 300mm x 300 mm x 300 mm depth of which 300 mm will be below the ground cement concrete pedestal work.with 150 mm channel above the ground length.
CHEQUERED PLATE WORK : Supplying, fabricating by welding etc. and erecting in position for various items for making MS Grill door, made up of M.S structural memebers like ISA, M.S flats, M.S circular , MS square, Chequered plates etc of TATA, SAIL, RINL make conforming to IS specification including M.S holdfasts,aldrop and single coat of Zinc chromate primer and two coats of first quality synthetic enamel paint of ASIAN Paints make as approved, specified and directed by EIC.
Provisioning of battery bank with charger : Supply and provisioning of maintenance free battery bank with suitable charger for 24/110V DC power packs with 30 min back up and all terminations with existing HT panel. scope incudes all terminations as per directed by EIC Make:Amar Raja/Exide/equivalent
Provisioning of Exhaust Fans: Supply and fixing of 9 inch exhaust fan with louvers & with necessary accessories as per direction of EICs Scope includes provisioning of concrete wall cutting for exhaust fansMake: CGL / Usha / Almonard
Provisioning of BUS BAR Chamber : Supply and provisioning of 3 phase, 440V, 400A factory made Copper Bus bar chamber on wall/ gounting in floor with necessary accessories as per direction of EICs
20 PAIR TELEPHONE CABLING: Supply and Iaying of 20 Pair unarmoured 0.50 mm dia of each strand, telephone cable in a suitable rigid PVC conduit of 2mm thickness with all necessary bend, junction boxes and other acceessories. Make: Amp /Finolex/ Dlink / Mazda / polycab
10 PAIR TELEPHONE CABLING: Supply and Iaying of 10 Pair unarmoured 0.50 mm dia of each strand, telephone cable in a suitable rigid PVC conduit of 2mm thickness with all necessary bend, junction boxes and other acceessories. Make: Amp /Finolex/ Dlink / Mazda / polycab
5 PAIR TELEPHONE CABLING: Supply and Iaying of 5 Pair unarmoured 0.50 mm dia of each strand, telephone cable in a suitable rigid PVC conduit of 2mm thickness with all necessary bend, junction boxes and other acceessories. Make: Amp /Finolex/ Dlink / Mazda / polycab
2 PAIR TELEPHONE CABLING: Supply and laying of 2 Pair unarmoured 0.50 mm dia of each strand, telephone cable in a suitable rigid PVC conduit of 2mm thickness with all necessary bend, junction boxes and other acceessories. Make: Amp /Finolex/ Dlink / Mazda / polycab
Supply and connection of Push button phone from the modular telephone jacks through line cables and rozer box as required in the site. Vendor should use rubber floor cable cover to a max of 3 mtr per telephone connection.
50 PAIR TELEPHONE CABLING: Supply and Iaying of 20 Pair unarmoured 0.50 mm dia of each strand, telephone cable in a suitable rigid PVC conduit of 2mm thickness with all necessary bend, junction boxes and other acceessories. Make: Amp /Finolex/ Dlink / Mazda / polycab
PA System: PA speaker Supply and installation of PA speaker 6-8w roof mount on existing wall as directed by EIC
Face Reader with access door system: Supply and provisioning of biometric based face reader door access system with all sccessories as per site condition as directed by EIC Make: Time watch/ESS/Godrej
RJ-11 TELEPHONE SOCKET(Jack Type): Supply and fixing of RJ- 11 telephone socket with 2 mm thick GI modular box independent surface mounted / concealed in the wall with inter connection complete. Make Legrand / Seimens / Crabtree
RJ-45 LAN SOCKET: Supply and fixing of RJ- 45 lane socket with 2 mm thick GI modular box independent surface mounted / concealed in the wall with inter connection complete. Make Legrand / Seimens / Crabtree
Supply Fixing of 15U Rack on existing walls by supplying all required accessories like 2 nos. PDUs as per site condition. The scope also includes dressing of all cables.(NOTE: Rack will be suplied by HAL).
Supply, laying and testing of CAT - 6A cabel on existing walls / trays by supplying all required fixing accessories with suitable size PVC pipe as per site condition. MAKE: AMP/ Molex
Supply, crimoing, fixing and testing of I/O connecter suitable to CAT - 6A cabel as per site condition. MAKE: AMP/ Molex
Supply, fixing and testing of connecter suitable to CAT - 6A cabel on existing jack panels by supplying all required fixing accessories as per site condition. MAKE: AMP/ Molex
Supply, Fixing, Installation, testing and commissioning of 24 port 10/100/1000 mbps switch + 4X SFP Ports (Enterprise Model) in the existing rack with all accessories as per site condition. The switch shall have internal fan for air cooling. The Scope includes the configaration of the switch as per requrement. MAKE: Extreem 5320.
Supply and Installation of Extreme SFP Gigabit LX/ copper Modules in existing rack as per site condition.
Supply , fixing and termination of 24 port jack panel (Fully loaded) in the existing RACK of fixing of all accessories as per site condition Scope also includes supply of 5 Nos. of boxes each contains 100 nos. RJ-45 Jacks Make: AMP.
Supply, fixing and dressing of CAT 6 E Patch Chords (3 mtrs) as per site condition.
Supply, fixing and dressing of CAT 6 E Patch Chords (1 mtr) as per site condition.
Supply, fixing and dressing of CAT 6 E Patch Chords (0.5 mtr) as per site condition.
Supply, fixing and dressing of CAT 6 A Patch Chords 1.0 mtr) as per site condition.
Provisioning of ATS : Supply and provisioning of 4 Pole,415V , 200A auto change over switch on existing wall , installation to be done as per EIC dirction Mke: Socomac/Havels/ABB/L&T
FIRE POINTS: Supply, installation, testing & commissioning of intelligent analog addressable photothermal detector/OT series (Make: Bosch) with mounting base complete as required, device to be fixed on existing roof/struss/false celing & integrating with Bosch existing Fire Alarm system with fixing accessories as per site condtion.
FIRE POINTS: Supply & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required on surface of the wall/roof/struss with fixing accessories as per site condition and connecting to detectors/response indicator/horn cum strobe/manual call point/ Main fire alarm panel etc as directed by EIC Make: Polycab/Finolex
FIRE POINTS:Supply, installation, testing & commissioning of addresable horn/sounder cum strobe (Make: Bosch) with mouting base complete as required, device to be fixed on existing roof/struss/ false ceiling & integrating with existing Bosch Fire Alarm system with fixing accessories as per site condtion.
FIRE POINTS: Supply, installation, testing & commissioning of response indicator compatible to Bosch photothermal detector on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required, device to be fixed on false ceiling & integrating with Bosch existing Fire Alram system with fixing accessories as per site condition
Upgradation of existing KONE make lift:Upgradation of lift for operation up to 5th floor by replcing VF3 drive assembly,Control PCB assembly, Rope assembly,Door module, load weiging balences and emmergency rescue assembly etc. Scope of work provided as attachment at ANNEXURE-A. Vendor may visit site prior to quote to understand the scope of work
Provisioning of Man Trap Door Systemt: Supply and provisioning of two door interlocking facility (man trap door) with following specifications .modular metal doors made up of 1.2mm GI frame:100mm width, Leaf with double skin 0.8mm thick GI, colour is Light/smoke grey powder coated, infil honeycomb 40mm, door sie os 1200mm x 2400 with hardware, SS Hinges, Lock, door handles, and view double glazed glass - 2 sets Two door interlocking system: 2 door controller panel-1 Emlock with Sensor - 2 Emlock encloser - 2 Digital display kepad - 4 nos Emergency keypad - 2 nos Data cable - 20 mtr 3 pin socket along with modular box for power supply
ROAD BOARING work for HT Cable: : Road Boaring of all kinds of earth below 800- 1000 mm depth from the surface of road for routing of 300 sqmm HT cable through suitable hume pipe/PVC pipe as per site requirement completely with good finishing as per direction of the engineer in-charge.Scope includes digging of soil on both sides of road .
Sucessful offer that is L-1 (Lowest offer) will be determined including GST.
The payment terms shall be governed as per the terms indicated in General conditions of contract.
Amount towards GST will be paid along with RAR payment against invoice.
The tenderers are requested to abide by the rules of prevailing GST act.
This BOQ specification has to be read in conjunction with technical specifications and tender drawings if any. Any ambiguty in these have to be brought to the knowledge of contract section before submission of tender to avoid future claims/dispute.
HAL/HD/CE/T/26-27/4
Electrical works for Up-gradation of GCA Building
Description
Name of the Individual / Firm / Company: * (Mandatory)
Type of ownership / Legal Status [Attach copies of the original document defining the legal status]
Year of Establishment of Company/Business
Registered Office Address, Telegraphic Address, Telephone No., Website / email id, FAX No.
Correspondance Address, Telegraphic Address, Telephone No., Website / email id, FAX No.
PAN no
PF number (If any)
ESI number
GST registration number
Particulars of registration with various Government bodies (Attach documentary proof)
Contact details
Please enter Contact person name
I.T Returns for past 03 years
Enclosed
Enclosed
Enclosed
Maximum value of works executed during the following 05 years and it should be certified by Chartered Accountant. (In Rs. Lakhs)
Please enter maximum values of works (sum of all the works in the respective year) in Rs. Lakhs for all the years
DETAIL OF WORK ON HAND UPTO COMPLETION PERIOD OF SUBJECT WORK [Required for Bid capacity calculation] .Details are also to be furnished on Proforma-D
Name of Organization with address
Action plan / bar chart as to indicate the completion of work, within the scheduled time (contract period)]
Bank(s) details: [Copy of the cheque leaf to be uploaded]
Bank Account No.
Name of the Bank
Type of Account
Branch, Place
Bank Code No.
MICR No.
ECS No.
IFS Code
Bank Statement for past THREE months
Latest Over draft Facilities with Bankers
Latest Bankers Solvency Certificate from Nationalized/ scheduled Bank issued NOT before 12 months from the final date of submission of Tender.
Please enter Latest Solvency Details and upload the same
Experience of having successfully completed similar works during last 7 years ending on the previous day of submission of tender should be either of the following:. [ Work completion certificates along with LOA/PO/WO should be uploaded] (i) THREE similar completed works each costing not less than the amount equal to 40% of the estimated amount put to tender. (ii) TWO similar completed works each costing not less than the amount equal to 50% of the estimated amount put to tender. (iii) ONE similar completed work costing not less than the amount equal to 80% of the estimated amount put to tender.
You are Not Eligible
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Brief Description of Work:
Completed value of Work in Rs.
Date of Commencement of Work [DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Name of The organisation
Brief Description of Work
Completed value of Work in Rs.
Date of Commencement of Work [DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
Type of Work [ Incase of private works the same shall be supported with TDS certificate]
Name of The organisation
Brief Description of Work
Completed value of Work in Rs.
Date of Commencement of Work [DD/MM/YYYY]:
Date of Actual Completion of Work[DD/MM/YYYY]:
DETAILS OF TECHNICAL PERSONNEL AVAILABLE( if space provided is insufficient separate sheet to be uploaded with the same format as below)
Name of members or technical personnel available in the organization
PLANT, MACHINERY AND EQUIPMENT AVAILABLE [The Plant, Machinery and equipment (either owned or leased) that can be made available for this work must be furnished below].
Name of Machinery
Works of similar nature successfully completed in addition to Sl. No. (21) of Applicant Particulars (1) during the last 07 years ending last day for previous month.
Name of the work / project and location
Details of person holding the power of Attorney
Please enter Person holding the power of attorney
DECLARATION I
Please Accept the Declaration I
DECLARATION II
Please Accept the Declaration II
EMD details
SBI collect Ref No
Please enter Tender Document EMD Details
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
ScopeofworkCT4.pdf
TENDER_DOCUMENT • 0.01 MB
NITCT4.pdf
TENDER_DOCUMENT • 0.21 MB
Checklist.pdf
TENDER_DOCUMENT • 0.02 MB
TBCT4.pdf
TENDER_DOCUMENT • 3.72 MB
AnnexureK.pdf
TENDER_DOCUMENT • 0.01 MB
EFTmandateform.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureI.pdf
TENDER_DOCUMENT • 0.01 MB
ProformaA.pdf
TENDER_DOCUMENT • 0.01 MB
coveringletterEMD.pdf
TENDER_DOCUMENT • 0.01 MB
ProformaB.pdf
TENDER_DOCUMENT • 0.01 MB
PriceBidCT4.xlsm
TENDER_DOCUMENT • 0.09 MB
PQCE5.xlsm
TENDER_DOCUMENT • 0.03 MB
PROCESSDOCUMENTFORSBICOLLECT.pdf
TENDER_DOCUMENT • 1.18 MB
ProformaC.pdf
TENDER_DOCUMENT • 0.01 MB
ProformaD.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIIB.pdf
TENDER_DOCUMENT • 0.01 MB
AnnexureIIC.pdf
TENDER_DOCUMENT • 0.01 MB
Download all tender documents and submit your bid