| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.1 L+₹42,640 (3.64%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-AOC L2 | |
| 3 | L3₹12.4 L+₹67,414 (5.75%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹13.6 L+₹1.8 L (15.7%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹14.5 L+₹2.8 L (23.6%)Rejected-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹32,840
Closing Date
10 Oct 2020, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
SPECIAL REPAIR/REPLACEMENT OF AMF PANEL IN AN-32/DORNIER FTD AND MAINTENANCE OF AIRFILED LIGHTING SYSTEM AT AFS YELAHANKA
2020_MES_377105_1
8781/E8
Open Tender
Civil Works
Item Rate
180 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹32,840
Yes
22 Dec 2020
12 Sept 2020
12 Oct 2020
12 Sept 2020
10 Oct 2020
27 Sept 2020
Amount
Supply and installation of AMF panels 415 volts, 3 phase 4 wire,volts indoor type compete having a busbar capacity of 400 A consisting of all accessroies mentioned below with battery charging system , overload protection and connected internal wiring complete for automatic starting of DG set of capacity 200 KVA and automatic changeover to DG set whenever main supply fails and vice versa including the following indicators, swiches and controls upto 200 KVA
Supply and installation of AMF panels 415 volts, 3 phase 4 wire,volts indoor type compete having a busbar capacity of 400 A consisting of all accessroies mentioned below with battery charging system , overload protection and connected internal wiring complete for automatic starting of DG set of capacity 160 KVA and automatic changeover to DG set whenever main supply fails and vice versa including the following indicators, swiches and controlsupto 160 KVA
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for laying pipes etc and getting in hard/dense soil.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soil.
Removing surplus soil to a distance not exceeding 50m and depositing at a level not exceeding 1.5m above the starting point.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI wire 4 SWG dia by means of bolts, nuts, check nuts and washers of galvanised iron and earth strip upto 7.5m and excavation earth work, PCC chamber, RCC cover slab, charcoal, salt watering pipe wiremesh water funnel etc all applicable and as per plate No 5 of SSR Pt-I 1991 and all as specified. (Note : The rate is inclusive of earth work and excavation PCC chamber in PCC (!:3:6) type C1 RCC Cover slab 50mm thick with RCC (1:2:4) type B1, with 8mm CTD bards re-inforcement both ways at 140mm centre to centre.
Material and labour for straight through joint heat shrinkable for underground cable including joint kit and labour complete for making joint suitable for copper conductor underground HT cable of grade 3.3 KV for taxi/runway lighting.
M/L for PCC 1:3:6 type C1 using 20mm graded stone aggregate with necessary form and coping complete for plinth of taxi/runway lights
M/L for laying of GI earth wire of size 4mm dia in trench and connecting to earth terminals for taxi/runway lights
devan enterprises
SRI LAKSHMI CONSTRUCTIONS
MAJ CONSTRUCTIONS
Shanthi Construction
M/S Sneha Enterprises
G K CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .