Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Accepted |
| 2 | Accepted-Technical 99 OLD SANTOSHI NAGAR OPP TO DEVIKA GAS AGENCY JULE SOLAPUR SOLAPUR 413004 | SOLAPUR | SOLAPUR | MAHARASHTRA | 413004 | Accepted-Technical Accepted |
| 3 | Accepted-Technical | Accepted-Technical Accepted |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹18.9 L
Closing Date
23 Mar 2026, 5:00 pmClosed
E E WORKS DIV 01 Z P SOLAPUR
E E WORKS DIV 01 Z P SOLAPUR
Construction of Two New School room building First Floor for Z P Primary School at Ankalge Taluka Akkalkot Dist Solapur
2026_SOLAP_1287484_1
61/2025-26
Open Tender
Civil Works - Buildings
Percentage
180 days
Construction of Two New School room building Fir
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
Exempted
23 Apr 2026
16 Mar 2026
24 Mar 2026
16 Mar 2026
23 Mar 2026
16 Mar 2026
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m)
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing out water, Steel centering, formwork, laying / pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) - For Ground Floor
Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) For Ground Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite / gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) For Ground Floor
For First Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying / pumping, compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) For Ground Floor
For First Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying / pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) For Ground Floor
For First Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite / quartzite / gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying / pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) First Floor Floor
Providing and laying Cast in situ / Ready Mix cement concrete in M-20 of trap / granite / quartzite / gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying / pumping, compacting, curing , finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) For Ground Floor
Providing second class Burnt Brick masonry with conventional/I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. For Ground Floor
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in Superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete For Ground Floor
For First Floor
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. For Ground Floor
For First Floor
Filling in plinth and floors with approved excavated material in 15cm. to 20cm. layers including watering and compacting etc. complete. For Ground Floor
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. For Ground Floor
Providing and fixing steel windows of verious as per detailed drawings without ventilator and steel frame of angle 40x40x5 mm and shutter frame of 25x25x5 mm and shutter with MS sheet of 18 guage of approved quality with hold fast neceaasry fixing and fixing and fastening and fixtures,necessary welding with oil painting three coats including primer coate complete as per detailed drawings and as directed complete. (Including M S guard bars of 12 mm at 10 cm c/c and MS flat of 40x6 mm) For First Floor
Providing and fixing double leaf steel door without ventilator including shutter of MS frame of angle 50x50x6 mm and shutter frame of MS angle of 30x30x6 mm and shutter sheet of 10 guage of approved quality with hold fast neceaasry fixing and fastening and fixtures,necessary welding with oil painting three coats including primer coate complete as per detailed drawings and as directed complete. For First Floor
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. For Ground Floor
For First Floor
Providing internal cement plaster 20mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing complete. For Ground Floor
For First Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete For Ground Floor
For First Floor
Providing and laying vitrified matt fininsh tiles having size 590mm to 605mmx to 605mm of 8 to10 mm thickness and confirming IS.15622-2006 (GroupBla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc.complete. For Ground Floor
For First Floor
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete For First Floor
Providing and laying machine cut machine polished shahabad Stone slabs 20 to 25mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. For Ground Floor
Providing and applying white-wash in two coats on old/new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete. For First Floor
Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. For Ground Floor
For First Floor
Providing and applying two coats of water proof cement paint of approved manufacture and of approved olour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. For Ground Floor
For First Floor
Providing and fixing Information sign board of size 0.90 X 0.60 m . Prepared on 16 guage M S Sheet with horizontal bracting of M S flat os size 25 X 6 mm uncluding painting with one coat of zinc cromzte primer and two coats oil painting including twonumber of M S angleiron post of size 50 X 50 X 6 mm of 2.70 m longincluding conveying all taxes fixing in ground with cement concrete 1:4:8 block of 45 X 45 X 45 cm size as directed by Engineer in charge stc. complete.
Royalti Charges for Sand.
Royalti Charges for Rubble/Stone/Murum.
Test of Concrete - Compressive Strength OF C.C. Cube (Set of 3 cubes).
Test of Steel - (Tensile strength, %, Elongation, Yield Stress,Weight-Per Meter, Bend / Rebend Test, Proof Stress.)
BASIC TEST OF BRICKS - Water Absorption (Set of 5 Bricks), Compressive Strength( Set of 5 Bricks), Efflorescence (Set of 5 Bricks).
Add 18% for G.S.T. charges On Rs
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.55 MB
sbd.pdf
Tender Documents • 2.22 MB
BOQ_2213816.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .