1. Signaling arrangement in connection with proposed Proposed construction of Road under bridge (RUB) in lieu of LC No.63A(M) Up,DN & third line portion at Km 379/22-24 as precast RCC Box of size 2x9.00x5.50m between KZJ - WL stations by AIR pushing method.2.VKB-PRLI section: Signal & Telecom arrangements in connection with Proposed replacement of LC with RCC box (RUB) at LC No. 8 KM 10/6-7 between VKB-SSPD stations 3.VKB-PRLI section:Signal & Telecom arrangements in connection with Proposed replacement of LC with RCC box (RUB) at LC No.20 KM 38/14-15 between MRF-KOHR stations 4.VKB-PRLI section: Signal & Telecom arrangements in connection with Proposed replacement of LC with RCC box (RUB) at LC No.39 KM 82/11 between MTV-BIDR stations 5.VKB-PRLI section: Signal & Telecom arrangements in connection with Proposed replacement of LC with RCC box (RUB) at LC No-60 KM 118/13-14 between HBU-BHLK stations 6.VKB- PRLI section: Signal & Telecom arrangements in connection with Proposed replacement of LC with RCC box (LHS) at KM 71/2-3 between ZB-MTV stations 7. Signaling arrangements for proposed Rebuilding of existing Br. No. 550 Up & DN at Km N. 418/3-6 as precast RCC box of size 2x6.00x3.80m between INK and KDM stations by Air pushing method.8.Signaling arrangements for proposed Rebuilding of existing Br.No.693A DN span 9x1.20 STC at Km No. 502/12-14 as precast RCC box with comon web of size 3x5.00x1.70 m between Chintakani and Nagalwancha stations by Air pushing method.9.Signalling arrangement in connection with KZJ - BPQ section -Proposed replacement of existing 2x12.20m steel girders with PSC slabs for BR No. 31 (UP) at km 348/1-3 between HSP-OPL stations of KZJ-BPQ section.10.Signaling arrangement in connection with KZJ - BPQ section -Proposed replacement of existing 2x12.20m steel girders with PSC slabs for BR No. 161 (DN) at km 251/26-28 between MMZ-RVKH stations of KZJ-BPQ section.11.SC Division SC-KZJ section : Signal & Telecom arrangements in connection with prop
C-SG-36-545
C-SG-36-545
Open
Works - General
12 Months
Jayashankar Bhupalapally, Telangana
₹0
₹2.4 L
4 Apr 2025
4 Apr 2025
Item Breakup - A-SUPPLY PORTION - SOR
Supply of GKP type Location Boxes Full size Numbers as per drg. No. S&T/MFT/2378 (Single) (TO BE INSPECTED BY RITES)
Supply of GKP type Location Boxes Half size Numbers drg. No. S&T/MFT/2378 (Half) (TO BE INSPECTED BY RITES)
Supply of 'E' type locks of different wards as Numbers per requirement with key per E- type lock to Drg. No. SA.3376/M/Latest and RDSO Specn. No. IRS. S.30/64. (TO BE INSPECTED BY RITES)
Supply of Universal locks with one Steel key Numbers for every ten locks. (TO BE INSPECTED BY CONSIGNEE)
Supply of relay fixing frame for Full location Numbers box, the frame should be made out MS angle of 25mm X 25mm X 3mm and approximate size of 940mm X 150mm with suitable holes to fix the same in the box.(TO BE INSPECTED BY CONSIGNEE)
S u p p l y o f P V C i n s u l a t e d w i r e copper Numbers conductor 16/0.2mm to ATC IS:694 to RDSO specification no.IRS:S-76/89 as per amendment 2 or latest.. Each coil of 100 mts length.To be procured from RDSO approved firms. Quantity unit in Coils. (TO BE INSPECTED BY RDSO)
Supply of PVC insulated wire, multi strand Numbers flexible copper conductor, 28/0.3 mm. to RDSO specification IRS.S.76/89 with amendment 2 or latest.Each coil of 100 mtrs length and to be procured from RDSO approved firms. Quantity unit in Coils. (TO BE INSPECTED BY RDSO)
Supply of PVC insulated wire multi-strand Numbers copper conductor 10 Sq.mm flexible Specn.IRS.S76/89.Amendment No.2 or latest. Each coil of 100 mts length. To be procured from RDSO approved firms (size 140/0.3mm)(Red-50%,Black-50%) Quantity unit in Coils. (TO BE INSPECTED BY RDSO) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Non-deteriorating type of fuse Numbers holders 20 Amps Capacity - electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip/Knife edge type size E1(R-SS) (TO BE INSPECTED BY RDSO)
Supply of Non-deteriorating type of fuse Numbers links 16 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip (TO BE INSPECTED BY RDSO)
Supply of Non-deteriorating type of fuse Numbers links 10 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip (TO BE INSPECTED BY RDSO)
Supply of Non-deteriorating type of fuse Numbers links 6 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip (TO BE INSPECTED BY RDSO)
Supply of Non-deteriorating type of fuse Numbers links 2 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78-2006 IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip (TO BE INSPECTED BY RDSO)
Supply of terminal block 6 way PBT 25mm Numbers as per RDSO Drg.No. SA.23756/Alt.3 & IRS S.75/91 & IRS.S.23 with amendment no.2 or latest. (TO BE INSPECTED BY RDSO)
Supply of terminal block 1 way PBT 60mm Numbers as per RDSO Drg.No. SA.23745/Alt.5 & IRS S.75/91 & IRS.S.23 with latest amendment. (TO BE INSPECTED BY RDSO)
Supply of WAGO Terminal as per RDSO Set Specification No. 189/2004 which consists as per following: a) 2 Conductor disconnect type terminal block as per Model No. 280- 870 -- Qty: 6 No. b) End plate type 280-374 suitable for disconnect terminal of Model No.280-870 -- Q t y : 1 No. c) End stop terminal block type 249-117 -- Qty: 2 No. d) Shorting links (16A) as per model 280-402. (TO BE INSPECTED BY CONSIGNEE)
Supply of Markers for the WAGO terminals Set as per Model No. 249-502 (Plain masker) - 100 No. (TO BE INSPECTED BY CONSIGNEE)
Supply of Surface base of 140mm dia to suit Numbers signal post as per Drg.No.S-2011/M. or latest (TO BE INSPECTED BY RITES)
Supply of CLS post 140mm dia 3.5 Mtr.long Numbers to Specn.No.IRS-S/6-81 or latest (TO BE INSPECTED BY RITES)
Supply of CLS ladder set of 3.5 Metre long Set complete with staging, supports, signal number plate, cast iron ladder base to suite 3.5 mtr post ,as per drg.no.SA.23153.S.2033. or latest (TO BE INSPECTED BY RITES) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Colour Light Signal Unit - 3 Aspect Numbers complete to Drg.No.SA 23003/A/M with Spec IRS.S 26-64 latest amendment. (TO BE INSPECTED BY RITES)
Supply of Electric Key Transmitters single Numbers complete to drg.no.SA.22601/Alt-4& IRS S.21/2001 to ward no. specified. (TO BE INSPECTED BY RITES)
Supply of Tool kit as under (1)Standard tool Set bag {CANAVAS} - 1 (2) Soldering iron {Make "soldern / philips"} - 60W / 230 to be kept in Eqypitment room-1 (3)Multi meter suitable for BPAC {Digital Philips / FLUKE /18 S Rishi B} up to 20M ohms 10A 5KHZ 2 mV TO 750 AC 200 V DC - 1 (4)Screw Drivers - adjustable with common handle for different screw drivers (taparia make) - 6 pieces (5) Cutting plier 6'' (Taparia) -1 NOS (6) side cutter 6'' (WIRE CUTTER) (Taparia) - 1 NOS (7) Nose plier round insulated 6'' (Taparia) -1 NOS (8) Wire stripper (Taparia) -1 NOS (9) Fiber tape 3meters -1Nos (10) Scale 6'' (for long rail opening)-1Nos (S S material) (11) Pop Spanner Wrench 6mm to 22 mm (Auto Adjustable spanner) (Taparia make) -1 (12) Pop Spanner Wench 10mm to 30 mm (Auto Adjustable spanner) (Taparia make) -1 (13) Spanner Wench 15mm to 41 mm (Auto adjustable spanner) (Taparia make) -1 (14) Hacksaw frame with blade 6'', 4'' width (For cutting cable) - 1Nos (15) Hammer 3.0 LBs with handle -1Nos (16) Chisel 5'' (For cutting bond wire --1Nos) (17)Poker 8'' (for removing bond wire and bond pins) - 1Nos (18) Screw driver Heavy duty 12'' with plastic handle (For opening of dection contacts (Taparia) - 1 Nos (19) Test piece (PB wedge piece) - 2 Nos (20) high power torch light -1Nos (21) Universal Key Steel -- 2 Nos (22) Insulated Box Spanner for 6 Way terminals (13mm) for opening ARA terminals-- 1Nos) (23) nylon brush --1 Nos (24)Sealing plier ---1Nos (25) Crimping Tools (1.5 to 16sq mm ) - 1Nos (26) 11 nos Feeler Guage --1Set (27) TSR Meter (For testing condition of track circut) --1Nos (28)Wooden Block (60mm X 60mm )for providing between toung rail & stock rail during mainteance--1Nos (29) Track Shorting clips --1 Nos (30) Tester-1 No (31) Flat file 12 '' length X 1''Width -1 Nos (32) Insulated Spanner Set 6mm-20mm ten nos (TO BE INSPECTED BY CONSIGNEE)
Supply of Double Key Lock INSPECTED BY CONSIGNEE)
Supply of various type of lugs as per Numbers instructions of site in charge (TO BE INSPECTED BY CONSIGNEE)
Supply of copper lugs10 Sqmm of reputed Numbers make (TO BE INSPECTED BY CONSIGNEE)
Supply of Copper eyelets to suit 16/0.2 wire Numbers Dowell's make (TO BE INSPECTED BY CONSIGNEE)
Supply of Copper eyelets to suit 10.sqmm Numbers wire Dowell's make(TO BE INSPECTED BY CONSIGNEE)
Supply of piezo buzzers working on 24 V DC Numbers reputed make (TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Relay QECX61 plug in type Style Numbers "Universal plug in type AC LED lamp proving relay for all types aspects with built in current transformer type, slow release neutral line relay, 4F.4B contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110V AC, LED signal lamp Rate (in Rupees)d at 15W confirming to RDSO spec. STS/E/Relays/AC lit LED signal/09-2002, BRS 941A,IRS:s34 & IRS:S23 (as applicable).The interlocking code for this unit shall be ABDHK(with ATC clips). (TO BE INSPECTED BY RDSO)
Supply of point contactor relay QBCA-1 AC Numbers immunized miniature plug in type DC biased contractor, attractive armature 24Voits DC with 2HF/4B contacts, Heavy duty front contact, contacts metal to carbon complete with plug board, retaining clips and connectors to specification. BRS 943,IRS. S .34 , IRS . S .23 as applicable (TO BE INSPECTED BY RDSO)
Supply of Relay AC immunized, plug in type, Numbers style QNA1K, DC neutral line, 24V 1000 ohms, 6F.6B contacts, front contacts metal to carbon and back contacts metal to metal / carbon, complete with plug board, retaining clip and connectors conforming to BRS 931A, IRS S- 60 , IRS S- 34 , IRS S23 and RDSO specification STS/E/Relays/UEA (PI), dated 30-6-97 (Annexure - II) (as applicable). The interlocking code for this unit shall be CDEKY.(with ATC clips) (TO BE INSPECTED BY RDSO)
Supply of AC immunized plug-in-type Style Numbers 'QSPA1', DC Neutral line, slow to pickup, 24V, 8F.4B contacts, front and back contacts metal to carbon, complete with plug board, retained clip & connectors conforming to BRS:933A, IRS:S 60, IRS:S 34 & IRS:S 23 (as applicable). The interlocking code for this unit shall be ABDEJ.(with ATC clips) (TO BE INSPECTED BY RDSO)
Supply of Thermo shrinkable jointing kit Numbers suitable for loading coil joint/condenser joint/derivation joint for 6 quad cable with transformers using thermoshrinkable.as per RDSO Spec.No.IRS.TC.77-2006(rev-1) wiith Amdt.1 or latest. (TO BE INSPECTED BY CONSIGNEE) Total 1327017.00
Item Breakup - B-SUPPLY PORTION - NON SOR
Supply of relay fixing frame for Half location Numbers box, the frame should be made out MS angle of 25mm X 25mm X 3mm and approximate size of 470mm X 150mm with suitable holes to fix the same in the box. (TO BE INSPECTED BY CONSIGNEE)
supply of fail safe electronic time delay Numbers Relay .Device mounted on a Q series relay base and covered with fixed timing of 120 seconds conforming to IRS:S:612000,IRS:S;34 and IRS :S23. The interlocking code for this unit shall be AFGKY (TO BE INSPECTED BY RDSO) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of Non-deteriorating type of fuse Numbers links 20 Amps Capacity electric fuse for Railway signalling.Rated voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S-78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip (TO BE INSPECTED BY RDSO)
Supply of Ladder foundation Shoe to Numbers Drg.No.S-2033. (TO BE INSPECTED BY CONSIGNEE)
supply of Godreg/Navatal locks 50 mm with Numbers duplicate keys (TO BE INSPECTED BY CONSIGNEE)
Supply of 24 FIBRE ARMOURED OPTIC FIBRE Kilometre CABLE AS PER Spec No.: IRS: TC: 55/2006 Rev. 1 Amdt No.1.1, 2.0 & 3.0. or latest Material to be procured from RDSO approved sources. (TO BE INSPECTED BY CONSIGNEE)
Supply of HDPE telecom duct with outer Kilometre diameter of 40mm and inner diameter of 33mm permanently lubricated as per specification TEC GR No.G/CDS-08/02,NOV 2004 or latest . HDPE pipe shall be supplied along with 4mm dia polypropylene rope of approved quality inside wherever required. The length of HDPE telecom duct should be 1 KM. End plugs to be provided along with drum (free of cost) (2 No. per Km.). (TO BE INSPECTED BY CONSIGNEE)
Supply of Optical fiber splicing ( joint ) Numbers enclosure (24F) for loose tube complete with all accessories as required (TO BE INSPECTED BY CONSIGNEE)
IBELL Cordless Drill Driver Cd12-74, 12- Numbers Volts,1 Battery+Bmc Box + Extra 32 Accessories, 12 Watts, Red or latest (TO BE INSPECTED BY CONSIGNEE)
Supply of Digital multimeterSpecifications: Numbers digital TRMS 5Digit 60000 counts withfollowing features Frequency range: 6Hz to 1MHz Frequencymv AC band width: 100KHz ACvoltage rage: 1mV-1000V, +/- 0.5% DC voltage rage: 1uV-1000V, +/- 0.05% AC currentrage: 1uA-10A, +/- 0.5% DCcurrent rage: 1nA-10A, +/-0.2% Capacitance range: 1pF-10000uF Datalogging: 32000Readings Dual display: Available Other features:Temparature messurement,Diode, continuty, Duly cyclemeasurement, self batteryvoltage measurement, Lowpass filter, Min, Max andAverage value recording, Backlight, Bargraph, Protectiverubber holster.Model no:Rishabh 6016 or Similar (TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply of High precision True RMS Clamp Numbers meter with display count 6000, AC current 600mA/6000mA/ 60A, DC Current 6000mA/ 60A, AC/DC voltage 600V, AC current resolution 0.1mA (@ 60A), Resistance 60MegaOhms, Capacitance upto 62mF, Frequency 10Hz to 60kHz with resolution 0.001Hz, Variable frequency control (VFC) mode, Zero button for DCA, Clamp opening 17mm, Non contact voltage measurement function. Brand :STAN ONE Model SCM222 or similar. Numbers=Per Unit,Inspection by Consignee. (TO BE INSPECTED BY CONSIGNEE)
Supply of Insulation Earth Tester Digital for Numbers meggering of signalling cable with 500 V.DC of MECO Make (TO BE INSPECTED BY CONSIGNEE) Total 423834.01
Item Breakup - C-LABOUR PORTION - SOR
Final location survey of cable route and Route Kilo final preparation of cable route plan as per Meter technical specification Sec 'B' Sl.No.2 (RKM)
Excavation of trench to a depth of 1200mm Route Kilo and width of 300m at bottom in all types of Meter soil(Normal soil/soft soil/sandy soil except in (RKM) h a r d morum / rocky soils /bridges/ level crossings/ track crossings/ coil pits, ) as per RDSO Sketch no SDO/CABLE LAYING /003 including marking of cable alignment, clearing of jungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge. (TO BE INSPECTED BY CONSIGNEE)
Excavation of trench to a depth of 1200mm Route Kilo and width of 300m at bottom in hard Meter morum soil as per RDSO Sketch no (RKM) SDO/CABLE LAYING /003 including marking of cable alignment, clearing of jungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge. (TO BE INSPECTED BY CONSIGNEE)
Cutting of rock up to a depth of 300 mm RMT and width of 300mm where rock is visible from surface, concreting to ground level after laying cables with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/CN/NEW/1. All the material is to be arranged by contractor SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Cutting of rock to a depth of 200 mm and RMT width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width 300mm above rock concreting 200mmx200mm after laying of cable with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/CN/NEW/3. All the material is to be arranged by contractor
Digging of cable trench to a depth of not RMT less than 30 Cms in rocky terrain, Concreting the trench with 150mm thick concrete with 1 cement: 2 sand: 4 graded stone aggregate 20mm nominal size. All the material is to be arranged by contractor
Trenching under Rails for crossing the RMT track(Track crossing) and refilling of trenches as per RDSO drawing No.SDO/CABLE LAYING /009. The track crossing shall be done at right angles.The depth of cable trench shall be 1.2 Mtr. below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 Mtr.. The ballast shall be Stored separately while making the trench and the earth soil shall be stored separately. while re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. this work has to be done under supervision of supervisor of S&T and supervisor of P.Way
Laying different type cables in the trench. RMT Termination covered elsewhere.
Jungle cutting along with the cable route
Supply & laying of DWC split pipe of RMT 120/103 mm dia, 2meter long in already dug cable trenches has per Drawing No.SK.9/11 .The unit of RMT means two split pipes of 1 Mtr each.(TO BE INSPECTED BY CONSIGNEE)
Breaking of metal/ tar road and refilling RMT after laying the cables as per drawing no.SDO/CABLE LAYING/010. The surface of the road shall be concreted to match with the old surface
Track crossing by horizontal boring method RMT based on the drawing no.DRM/J/6735 dated 7-8-03 (enclosed) and as advised by the engineer at site. This includes the supply and insertion(pushing) of GI pipe (80mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof. SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply Transportation and installation of Numbers RCC cable Route Markers with round collers. They should be standard Lettering "SCR","S&T",with SIGNALLING on the top engraved to a depth of 8 mm and painted on one side .They shall be painted with "Green" when placed at joint chamber, "Yellow" Placed at loop chamber and ''RED" at all other places the length is 1000mm width is 300mm and thickness 80 mm with reinformation as per drg.no: SK-12/10.Get the Approval of above material after supplying sample materials to Sr DSTE / SC office. (TO BE INSPECTED BY CONSIGNEE)
Supply and Laying of GI pipes of 100mm dia RMT medium quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS.4736-1986 with coupling wherever required as per Rly. Requirement over the Cement bridges, girder bridges and drainage etc. In case of Cement Concrete bridges, GI pipes are to be provided with brick masonary of 300x300x300mm at an interval of 2 M and the remaining portion to be covered with earth. In case of Girder bridges suitable MS clamps are to be provided at every 1 M with all fixtures and supports and the pipe ends are to be closed with brick masonry abiments of size 0.5 x 0.5 x 0.5 M. The cables are to be taken through the pipes without causing any damage. The pipes are to be drilled with holes 60 Nos 1/4" dia for 6 M length around the pipe in Zig-zag manner before laying as per Drg.No .SK-9/10&11/10&19/10&20/10 .All materials are to be arranged by the contractor. Note:-Contractor should submit the manufecturer internal test report,guarantee certificate,genuinness certificate for IS Brand. (TO BE INSPECTED BY CONSIGNEE)
Supply and Laying of GI pipes of 50 mm dia RMT medium quality to specification IS.1239 (part-I) 1990 and galvanised to specification IS.4736-1986 with coupling wherever required as per Rly. Requirement over the Cement bridges, girder bridges and drainage etc. In case of Cement Concrete bridges, GI pipes are to be provided with brick masonary of 300x300x300mm at an interval of 2 M and the remaining portion to be covered with earth. In case of Girder bridges suitable MS clamps are to be provided at every 1 M with all fixtures and supports and the pipe ends are to be closed with brick masonry abiments of size 0.5 x 0.5 x 0.5 M. The cables are to be taken through the pipes without causing any damage. The pipes are to be drilled with holes 60 Nos 1/4" dia for 6 M length around the pipe in Zig-zag manner before laying as per Drg.No .SK-9/10&11/10&19/10&20/10 .All materials are to be arranged by the contractor Note:-Contractor should submit the manufecturer internal test report,guarantee certificate,genuinness certificate for IS Brand. (TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Foundations, erection, fixing of ' E' type Numbers locks, painting the box and painting of termination & other particulars of Full GKP boxes . Metal Size of the aggregate should not be more than 40mm. Work to be done as per prescribed drawing no.SK/CN/1/89-A & B- All the material is to be arranged by the contractor except E- type lock ( E-type lock will be supplied by Rlys) (TO BE INSPECTED BY CONSIGNEE)
Foundations, erection, fixing of ' E' type Numbers locks, painting the box and painting of termination & other particulars of Half GKP boxes . Metal Size of the aggregate should not be more than 40mm. Work to be done as per prescribed drawing no.SK/CN/1/89-A & B- All the material is to be arranged by the contractor except E- type lock ( E-type lock will be supplied by Rlys) (TO BE INSPECTED BY CONSIGNEE)
Provision and laying in position cement cum concrete of 1 cement:3 sand:6 graded stone aggregate of 20mm normal size excluding cost of cement, centering and shuttering ( including transportation of all the material) . Plain cement Concrete of 1 cement: 3 sand : 6 graded stone aggregade 20mm nominal size
Cement 53 grade (@ the Rate (in Rupees) of Quintal 2.2 quintals per Cum of concrete
Supply of Cement Portland / Ordinary, MT confirming to ISS: 269/76.(To be supplied at site as per requirement and as per instruction of site engineer)
Cable termination including fixing of ARA Per terminals, fuses, LDs etc, Meggering the Conductor cables and recording the readings as per detailed technical specification. (All materials for the work except cable, ARA terminal, fuses and LD's shall be supplied by the contractor). Note: Payments can be made based on the meggering records submitted.
Numbering of location box as per standard Numbers practice and writing all Cable(main and tail ) termination particulars and equipments inside the location box as per the details.LB serial number on four sides of the box , c o n n e c t e d earth pit perticulars and implantation to the track.
Earthing and soldering of the cable armour Numbers and connecting to the earth bus bar .as per the Instruction of SSE/SE at Site (Quantity unit in Per Cable) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
"Excavation of Earth Pit and providing earth Numbers pipe of size 50mm dia, 3.5mm thick 2.0 m. long G.I. pipe with anti pulling out arrengement at the bottom and wound with 8SWG GI wire To be drawn from bottom of earth Pipe to top terminal point. with masonary tub constructed around at earthing locations as specified by site Engineer. Alternate layers of 30kgs-chrcoal and 30kgs-common salt to be filled in the pit while closing. The pipe perforation etc., to be carriedout as per drawing No. SK- 10/10. The earth pipe to be connected the function with GI wire 8 SWG from earth elctrode to CLS Base and extend the same wire upto the CLS Unit/Ladder and terminated with proper nut and bolt with washers. The GI wire and earth pipe above the ground level to be painted with Alluminium after the earth connection. Earth resistance should be less than 3 ohms. perticulars of earth pit no,date of installation and earth resistance Should be recorded .The masonary tub of size 300X300X300mm should be covered with cement slab. (All materials to be supplied by the contractor except cable.). Note 1) Payment can be done with proper certification perticulars of earth pit by the field Officer,supervisor and Contractor same should be enclosed with measurement and B i l l . 2)The Termination of GI wire with Galvanised Bolt and Nuts with washers of Size 12.5 mm. 3) 35 mm Alluminium lugs to be used for 2 Core 2.5 Sq.mm Cables with S o l d e r i n g " (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of MS-'C' channel of size Numbers 100mmx 50mm x 1200 mm with suitable clamps as per drawing No. S&T/ RE/78/2/76 and fitting to GI pipe 65/50mm (to be supplied by Railways) of spec. IS-1239/ Part- 1/ Light with couplings and with suitable clamps on Girder Bridges without drilling holes in the girders. GI Pipes are to be drilled with 6 holes of 1/4" dia. per metres around the pipe in zig zag manner before laying the 6 metres pipe. (TO BE INSPECTED BY CONSIGNEE)
Foundation, erection , wiring, painting Numbers testing and commissioning of Colour light signal 2/3/4 aspects including dependent shunt signal as per drawings of Drg.no.SC / / N / CN/ 62/ A Implantation distance writing. For foundation 1 cement: 3 sand : 6 aggregate shall be used .Size of metal aggregate not more than 40mm and river sand to be used. Work to be done as per prescribed drawings above. (All the material ,cement ,sand aggregate paint including nuts, bolts, washers required are to be arranged by the contractor.) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Manufacturing, supply and fixing of C/P/G/A Numbers /IB markers/Number plates for signals at various stations/LC gates with Engineering grade reflective sticker on 9 " dia MS sheet with clamps Number plate.Sizes will be given by site in charge. All required materials including fixing materials are to be arranged by the contractor this including releasing of existing and hand over the same to the nearest S&T Store. (TO BE INSPECTED BY CONSIGNEE)
Provision of SCREEN on signals when they Numbers fall within 2 meters from the live conductor by expanding metal ( size.20mm x 60mm strand 3.25 mm wide and 1.6mm thick ) as per the instruction of site engineer incharge, This includes supply of all materials including earth electrode and earthing arrangements. Drg. No.RE/S&T/S. 16/T/SK/26.A.85 & Drg. No.RE/S&T/sig/Tender/Alt.A/SK/13/85. (TO BE INSPECTED BY CONSIGNEE)
Wiring of Track circuit feed end and relay Numbers end complete with TLDs, batteries, charger, track relay, double lead wires, providing insulation etc,. connected with commissioning of track circuit including provision of bracket for TLD covers and painting. Anti-tilting arrangment has to be d o n e for track relays,Choks,resistor, chargers & batteries. in location box.
Drilling of holes 7.2mm on web of the rail , Numbers providing bond wires with PVC coated wire rope. (Bond pins single grove have to be supplied by contractor - Wire rope for bonding is covered under supply portion/suplied by the railway. ) (Quantity unit in Rail per joint)
Fabrication and supply of MS frames to suit Numbers 'Q' series relays to accommodate 6 No. in each set as per Drg.No. B.SG.CN. MISC.9.98 duly drilling required holes for relay bases (All materials such as frames, bolts, nuts and washers to be supplied by the contractor) (Only Relay bases will be supplied by the Railways).(TO BE INSPECTED BY CONSIGNEE)
Arranging of sufficient staff by contractor Sheet For giving test to the railway incharge in the following stages as per instructions for panel station . (a) Stage -1 : testing of wires drawn point to point using buzzer. (one time Before soldering and two times after soldering .)
(a) Circuit diagrams issued by the Railways Sheet ( of A-2 size ) are to be taken on reproduction tracing film and manually entering the relay contact number and other required circuit details if any. ( Reproduction tracing film and other consumables are to be arranged by the contractor.) (Quantity unit in Per sheet of A- 2 size) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
(b) Preparation of A-3 size drawings as at Sheet site. Providing one print on tracing paper on in stadard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness. ( Polyester tracing film and other consumables are to be arranged by the contractor.) (Quantity unit in Per sheet of A-3 size)
(c) Preparation of A-4 size drawings as at Sheet site. Providing one print on tracing paper on in stadard format. Drawings are to be prepared on polyester tracing film of double side 50 microns thickness. ( Polyester tracing film and other consumables are to be arranged by the contractor.) (Quantity unit in Per sheet of A-4 size)
(d) Taking copies of approved circuit Sheet diagrams/drawings issued by the Railways on ammonia printing paper. (A-2 size.) - including supply of ammonia paper. (Quantity unit in Each sheet of A-2 size)
(e) Taking copies of approved circuit Sheet diagrams/drawings issued by the Railways on ammonia printing paper. (A-3 size.) - including supply of ammonia paper. (Quantity unit in Each sheet of A-3 size)
(f) Taking copies of approved circuit Sheet diagrams/drawings issued by the Railways on ammonia printing paper. (A-4 size.) - including supply of ammonia paper. (Quantity unit in Each sheet of A-4 size)
Supply and fixing of 'AHUJA' make horn type Numbers loud speaker 15W 8 ohms impedience. (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of yellow retroreflective Numbers strips of 1" width each on both sides of the yellow painted portion for both the lifting barrier booms. (TO BE INSPECTED BY CONSIGNEE)
Supply and installation of Electronic Flasher Numbers unit operating on 230V/110V AC, 110V DC, able to drive 2 No. of flasher lights. (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of Electronic Hooter unit Numbers 24/110 DC of approved design/make able to drive 2 No. of Speakers of 8 ohms 15W. (TO BE INSPECTED BY CONSIGNEE)
Fixing and wiring RKT/EKT for siding or L.C. Numbers Gate interlocking as per Tech. /Specn. No. 15.12. This includes installation of Magneto telephones at location, gate, SM's office etc.,
Providing crank handle box, wiring, testing Numbers as per technical specification including concealed wiring in the wall
Fabrication,supply and Install of Gate Numbers control cum indication panel of Size 30X12 Inches as per the Gate panel diagram supplied by the railways, MS sheet Box complete with LED etc., painting, screen printing of gate plan, signal etc., and prewired with signal and gate control.and SM Knobs switches ETC... (TO BE INSPECTED BY CONSIGNEE)
Supply of Teak wood block counter suitable Numbers for DIADO/NBT block instruments as per standard drawing. (TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Carrying out of alterations to the working Sheet circuits and fixing of relays and relay groups and energisation of relays as per approved circuit diagrams. (All materials such as Rosin core, flux, nylon thread, eyelets and PVC dotted tape to be supplied by contractor. Indoor cables, relays and relay groups, fuses, LEDs, Resistances will be supplied by Railways. (Quantity unit in per sheet of circuit diagram)
Carrying out circuit alterations in the Numbers existing location boxes as per the new circuits which require excavation and releasing unwanted cables from the location box and taking new cables inside the location, clamping of new cables, filling the location box with standard up to the bottom of location and plastering.
Removal of existing 'Q' style / K-50 contact Per clips along with its wire from the relay base Conductor by carefully tracing out from the bunch of wires and taking out unwanted wires from the same as per the alterations shown in the circuit diagram issued by Railways. Drawing of fresh new wire from the relay base to another relay base as per the new wiring as shown in the circuit diagram without affecting the other wires. This also includes testing of wires using buzzer of the new wires drawn once before soldering, once after soldering (This includes of wires required for data loggers.)
Fixing relay bases on the relay frames Numbers erected in Relay Room, Wiring of all types of relays by drawing various sizes of w i r e s / m u l t i c o r e cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailed technical specification.Different colour codes and sizes of wire to be used as per standard practice. This also includes, provision of all PVC sleeves required to be provided. Copper lugs to suit to 16/02 wire and neat bunching, lacing with Modi Nylon / Twine thread and using PVC dotted tape with buttons were required. This also includes soldering all the wires in the relay room with Rosine core of IS Spec. 1921 ( 60 % Tin and 40% Led). Soldering should be done as per standard practice. This also includes inserting the clips, point to point testing as per the circuit diagram and plugging relays to Relay bases (except Inter-cables, relays other materials such as Rosine core, flux, nylon thread. PVC dotted tape should be supplied by the contractor). Point to point testing should be done in the presence of Engineer-in-charge as instructed in two stages, one before soldering and the other after soldering.
Fixing relay bases, wiring in location boxes, Per Relay bunching, fixing of relays as per circuit diagram. This includes fixing of condensers, resistance, 6 way / 1 way terminals/ WAGO, ND type fuses, LED indicators for fuses as per type fuses, LED indicators for fuses. SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Supply and fixing of teak wood reapers with Numbers 50 mm width x 20mm thick and length of 940mm applying two coats of wood primer after Smooth finishing and varnishing Etc... are suitable for Full location Box (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of teak wood reapers of Numbers size 50mm x 50mm x940mm in Full Box applying two coats of wood primer after Smooth finishing and varnishing Etc...and clamping the Cables. (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of teak wood reapers with Numbers 75mm width x 20mm thick and length of 940mm applying two coats of wood primer after Smooth finishing and varnishing Etc... is suitable for Full Box (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of teak wood reapers with Numbers 50mm width x 20mm thick and length of 470mm applying two coats of wood primer after Smooth finishing and varnishing Etc... is suitable for Half Box (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of teak wood reapers of Numbers size 50mm x 50mm x470mm applying two coats of wood primer after Smooth finishing and varnishing Etc...and clamping the Cables. (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of teak wood reapers with Numbers 75mm width x 20mm thick and length of 470mm applying two coats of wood primer after Smooth finishing and varnishing Etc... is suitable for half Box (Quantity unit in Per Reaper) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of 20mm thick teak wood Numbers planks of size is 940mmx20mm x300mm for Keeping Equipment in the Full Box after applying two coats of wood primer. (Quantity unit in Per PLANK) (TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of H.Wood planks of cum 40mm thick and not less than 200 mm width and required length with smooth surface, painting with black enamel (Hardwood, paints & fixing bolts are to be arranged by contractor).(TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of Teak Wood planks of of cum sizes as instructed by the site in-charge with smooth finishing surface to be provided where ever required such as in location boxes relay room, equipment room and battery room, Fine wood polish of approved quality to be applied for two times after thorough application of emery paper. Fixing bolts and wood polish supplied by the contractor painting (Hardwood, paints, fixing bolts are to be arranged by contractor).(TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Strengthening of signal/ full GKP/ Half GKP Numbers location box foundations by carrying out the earth work around the signal/box raming of the earth carrying out masonry work from bottom of earth. work using country stones and cement/mud masonary to prevent the earth from sliping down the bank.( All the materials required for the above work shall be arranged by the contractor).
Transportation of materials from any Stores Kilometre 23500.00 to Site and vice-versa including loading and unloading. Lead above 50 Kms.(Quantity unit in PTPK) (TO BE INSPECTED BY CONSIGNEE) Total 4254523.99
Item Breakup - D-LABOUR PORTION - NON SOR
Supply and Laying of Double Walled Metre Corugated Pipe(DWC) of REX or similar make of 120mm outer dia/103 mm inner dia to IS spec.no.14930-part-II for underground cables of SIX meters length with one snap fit coupler Note:-Contractor should submit the manufecturer internal test report,guarantee certificate,genuinness certificate for IS Brand. (Quantity per unit in Per Length of six mtrs) (TO BE INSPECTED BY CONSIGNEE)
Fencing for Location Box duly providing Set foundation (A pit of size 400mmX400mmX1000mm is to be dig and cement concrete foundation in the pit in the ratio 1:3:6 to be casted.) and fixing the frames/doors and E type lock to the fencing with the supplied material. The rail post/Angular is to be erected up right in the foundation. All the materials are to be arranged and used by the contractor (Rail post/angular/frames/E type locks will be supplied by the railway). Cutting of rail post/angular to the required length, transportation to the site by the contractor. (04 nos)
Fixing of Track Lead junction box with Numbers angles (50 x 50 mm x 6 mm size) drilling one hole on either side of the box of size suitable to take 2 Core Cable through Nylon grumets and fixing track lead junction box by the side of the track and Terminating tail cables in Track lead junction box taking through GI pipes drilling 4 holes 7.2mm dia connecting double track leads with bond pins. Running 2 Core Cable and Termination on ARA terminals duly fixing the same inside the TLJBs .
Supply and fixing of different sizes of PVC RMT casing/pipes on the wall or to the tables as required at site as per the instruction of the Railway representative.All the materials required such as screws,bends and clamps etc,..are to be arranged by the contractor (TO BE INSPECTED BY CONSIGNEE) SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Foundation & Erection of Electrically Lumpsum operated lifitng barriers assembly, drive mechanism, motors etc. as per technical specification enclosed as annexure -B, with control panel, boom locking arrangements & crank handles complete with Hand generator as per detailed technical specification and instructions of site in- charge.(The above work includes excavation of fit and concreting foundation for pedestal-2 nos :Excavation of pit and concreting foundation for meeting post-2 nos: Erection of Electrical Lifting barrier-1 Set: Fixing of EOLB Panel and its wiring-1 No.as per detailed technical specification and instructions of site incharge.
Testing and commissioning of Electric lifting Lumpsum barrier operation from panel.
Supply of Teak wood Board for fixing of 2 Set Nos EKT with 02 Nos of Push Button/Micro switches and 4 Nos 10 mm LED 10 sq.mm holders with resistance(only EKT will be supplied by Railways) and as directed by engineer in-charge at site(TO BE INSPECTED BY CONSIGNEE)
Supply and fixing of retro reflective Numbers (HIP)stop board made out of aluminum sheet 2 mm thick and lettering in three languages and fixing arrangements to boom pipe and as directed by engineer in-charge at site (TO BE INSPECTED BY CONSIGNEE)
Supply of paint of approved quality (Asian, Lumpsum Berger, Nicholson) and painting of complete sliding boom arrangements and accessories(Rectangular boom movement stand, pillar supports, resting stand with one coat of red oxide and two coats of Yellow/black enamel paint & Yellow colour retro reflective tape (HIP) with width of 12" and as directed by engineer in-charge at site (TO BE INSPECTED BY CONSIGNEE)
Supply of Pad locks of 40mm Nav-tal lock Numbers with duplicate keys and key chain with label as required at site (TO BE INSPECTED BY CONSIGNEE)
Fixing of RKT and wiring as per approved Numbers circuit drawing. Necessary LED indications to and push buttons also to be wired as per instructions of site in charge.
Excavation of pit to required size as Lumpsum directed by engineer in charge at site and casting of foundations in the ratio of 1:3:6 cement , sand, metal 40mm stone to be supplied by contractor approx 12 Nos. per each gate (10 Nos. of Rectangular frame pillar supports and 02 Nos. Resting stand) and as directed by engineer in-charge at site for ESLB
Fixing of E tyype locks for boom locking Lumpsum arrangement duly drilling of suitable holes for fixing with suitable bolts and finishing as per instructions of site incharge for ESLB
Straight through joint/Derivation joint Numbers without transformer: Installation of straight through joint or Derivation joint without transformer for LC gates as directed by Railway supervisor. SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
Excavation of Coil pit of size 1.5mtex1.5mtr Numbers at a depth of 1mtr for providing of 6 quad cable in coil at joint locations
Rectification and resplicing of existing mid Numbers section OFC joint. This includes supply and provision of joint repair kit & sleeves (TO BE INSPECTED BY CONSIGNEE)
Laying/Blowing of OFC/ Quad in trench and Metre trough HDPE/GI/RCC pipes where ever necesay (TO BE INSPECTED BY CONSIGNEE)
Supply and installation of OFC jointing pit Numbers with cover and required trenching to ease out cable/ duct as per site conditions. (TO BE INSPECTED BY CONSIGNEE)
Supply and providing of Polymeric Positive Numbers Temperature Co-Efficient Device self resetting type (PPTC) suitable for Railway Applications (TO BE INSPECTED BY CONSIGNEE)
Providing services of helping hand man Man-Days power to carry out miscllaneous / sundry works in the office/field between 8:00 Hrs and 20:00 Hrs of the day accompanying railway staff with all expences of transportation, accomdation, food, consumables etc with all ascents/descents , taxes, octroi , cess , fees , duties with contractor tools (TO BE INSPECTED BY CONSIGNEE)
Arranging (Wireman/Painter/Fitter/ carpenter) to assist in testing of Signalling functions like Signals, Points etc. This Man power shall not be engaged for other activities covered under other items. (TO BE INSPECTED BY CONSIGNEE)
Re-designing of proposed WL Stn EI in Lumpsum connection with CLOSURE of LC.63A at WL station in KZJ -BZA section Modification of existing EI system of Medha, as per RDSO spec. no. RDSO/SPN/192/2019 in connection with LC gate removal. This includes all hardware, software design, interface wiring, carrying out FAT, SAT and submission of documentation and commissioning. ("EI HARD WARE - RDSO EXECUTION: CONSIGNEE") SECUNDERABAD DIVISION-S AND T/SOUTH CENTRAL RLY
"Supply and installation and commissioning Lumpsum of TCAS equipment as per modified yard/ LC Gate closure Supply of botton bin, Supply of additional wiring accessories including relay racks, wiring coils, OFC accessories and etc.,Designing of circuits, Man power for removal of stationary TCAS, Relay racks and RFID tags, Provision of earthing (Maintnance free earthing material shall be inspected by RDSO/RITES. Balance material shall be inspected by consignee), Installation of released equipment, new bottom bin, Relay racks, wiring, SAT & commissioning, Supply of additional RFID tags and installatlion of the released and additional RFID Tags, Interface to the exiting NMS network, with changes in yard design. Note: This includes suply & installation / removal of RFID tags, Logic alteration, interface wiring, FAT, SAT and commissioning and submission of documentation. " (" HARD WARE - RDSO EXECUTION: CONSIGNEE") Total 11231837.04
A-SUPPLY PORTION - SOR
B-SUPPLY PORTION - NON SOR
C-LABOUR PORTION - SOR
D-LABOUR PORTION - NON SOR
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .