Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.1 LAdmitted-Finance | +4.90% | ₹9.1 L | L1 | Admitted-Finance |
| 2 | L2₹9.1 L+₹779.25 (0.09%)Admitted-Finance | +4.99% | ₹9.1 L+₹779.25 (0.09%) | L2 | Admitted-Finance |
Tender Value
₹8.7 L
EMD Value
₹17,317
Closing Date
13 Apr 2026, 5:00 pmClosed
Executive Engineer
Executive engineerO/o Executive Engineer Elect. Dept. DIV-IX tivim
augmentationexisting6.3MVAto10MVApowertransfromerat 220/33KVAmonaSS
2026_ED_28295_1
EEIX/tender15/25-26/3886 17-03-26
Open Tender
Electrical Works
Percentage
30 days
AmonaSS
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,500
₹17,317
O/o Executive Engineer Elect. Dept. DIV-IX tivim
23 Jul 2026
23 Mar 2026
15 Apr 2026
24 Mar 2026
13 Apr 2026
2 Apr 2026
1 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply of Materials | |||||
| 2 | Copper strip of size 60 x 12 mm for transformer neutral earthing and bushing of the transformer to the 11 KV take off structure | 50 | Mtrs. | - | - |
| 3 | Lighting/Surge Arrestors 9 KV station type, 10 KA Type: Gapeless Type, Applicable standards: IEC: 6099-4 &IS: 3070-1993 (part) No of units per arrester: Single unit of 9KV, Highest system voltage: 12kV , Normal systemvoltage: 11kV, System earthing : Solidity earth system , Rated Voltage in kV (RMS): 9kV, Nominal discharge current (8/20µ seconds wave):10kA, long duration discharge class:Discharge class-II, Maximum Continuous Operating VOltage (kV): 7.65 Vrms Insulation withstand test voltages a)One min. Power Frequency withstand voltage (Dry&Wet):28kVrms. b) Lightin g Impluse Withstand Voltage:75 Vpeak. Max.residual voltage for discharge c urrent of 8/20µ seconds. A) 5000Amps:25kVpeak B)10000Amps:27kVpeak C) 20000Amps:30kVpeak Maximumsteep current Impulse Residual Voltage at 10kA of AIu second front time :30peak. Maximum Switching Impulse Residual voltage30/60µ seconds at 500Amps:24kVpeak Minium energy Discharde capabilty : 5kJ/kV (OD test - 2 shots ). MountingFlange dimensions:3 slots on PCD | 6 | Nos | - | - |
| 4 | HDGI structural material for erection of 11kv lightning arrestor and termination of cable. I Beam 175 x 90 mm - 5 mts long, 2 nos , ISMC Channl 100x50x4.7 mm 3 mts long, 3 nos, Nut Bpits and Clamps | 300 | Kgs | - | - |
| 5 | XLPE outdoor heat shrinkable termination kit suitable for 3 core x 300 sq. mm 11 KV XLPE cable (make: Raychem / 3M) | 1 | Kits | - | - |
| 6 | SETC of Earthing of Centrufugally Cast Iron, 100mm dia nominal bore, 3000mm long pipe earth electrode. | 4 | Sets | - | - |
| 7 | GI Strip 50 mm x 6 mm for connecting all the various eqipment, switchgears, instruments etc. to earth grid. | 100 | Mtrs. | - | - |
| 8 | SETC of HDGI Flat strip of size 75x8mm for HDGI Earth grid/mat | 40 | Mtrs. | - | - |
| 9Erection of Materials | |||||
| 10 | 3 ph 10 MVA Delta/Star connected 33/11 KV 50 Hz Power trasformer, ONAF, Copper wound, Outdoor conventional type with first oil filling, OLTC Remote control panel for OLTC operation and all accessories complete. Make:Voltamp The following spares should include 1)33KV Bushing compitable to proposed Transformer- 1No. 2)11kv Bushing compitable to proposed Transformer - 1No. 3) WTI compitable to proposed Transformer -1 No. 4) OTI compitable to proposed Transformer - 1No. 5) HT Bushing stud suitable for proposed Transformer- 1No. 6) LT Bushing stud suitable for proposed Transformer- 1 No. | 1 | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 26.12 MB
Tendernotice_2.pdf
PDF • 0.75 MB
BOQ_28736.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .