Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 910 TULSIANI CHAMBERS NARIMAN POINT MUMBAI MAHARASHTRA 400021 | MUMBAI | MAHARASHTRA | 400021 | Admitted-Finance |
| 2 | Admitted-Finance 403 404 B WING DELPHI HIRANANDANI BUSINESS PARK POWAI MUMBAI 400076 | MUMBAI | MUMBAI | MAHARASHTRA | 400076 | Admitted-Finance |
| 3 | Rejected-Technical DHAR MADHYA PRADESH 454775 | DHAR | MADHYA PRADESH | 454775 | Rejected-Technical NOT ACCEPTABLE |
Tender Value
Refer Docs
Closing Date
10 May 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sekar Hirudhayam
TECHNIP ENERGIES INDIA LTD, CHENNAI
SUPPLY OF AMBIENT AIR QUALITY MONITORING SYSTEM (AAQMS)
2024_NRL_798868_1
TP/082176C/NRL/PQ/156
Limited
Electronics Equipment
Supply
270 days
NUMALIGARH
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
Exempted
TEAMS -ONLINE
30 Sept 2024
5 Mar 2024
11 May 2024
5 Mar 2024
10 May 2024
22 Mar 2024
14 Mar 2024
AMBIENT AIR QUALITY MONITORING SYSTEM (AAQMS)
AMBIENT SULPHUR DIOXIDE (SO2) (Pulsed UV Fluorescence principle, Rack mounted, Sample handling units, online calibration features, utilities, other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
H2S ANALYSER (Pulsed UV Fluorescence principle, Rack mounted, Sample handling units, online calibration features, utilities, other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
NITROGEN (NO-NO2-NOx) ANALYSER (Chemiluminescence principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/Guarantee.)
NH3 ANALYSER (Chemiluminescence principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/Guarantee.)
CARBON MONOXIDE (CO) ANALYSER (Non-Dispersive Infra-Red (NDIR) principle, Rack mounted, Sample handling units, online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT,Inspection and Testing, Special tools and Warranty/ Guarantee.)
OZONE (O3) ANALYSER (UV Photometric / Chemiluminescence principle, Rack mounted, Sample handling units, online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
CARBON DI OXIDE (CO2) ANALYSER (Non-Dispersive Infra-Red (NDIR) principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
TOTAL HYDROCARBON ANALYSER (Flame ionization detection (FID) principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
BTEX ANALYSER / MARKAPTAN ANALYSER (Gas Chromatographic separation and Photo Ionization Detector (PID) principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
CONTINUOUS PM2.5 MONITORING ANALYSER (β-ray attenuation principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
CONTINUOUS PM10 MONITORING ANALYSER (β-ray attenuation principle, Rack mounted, Sample handling units,online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
MULTI POINT GAS CALIBRATION SYSTEM (Auto calibration for calibration of SO2, H2S, NO-NO2-NOx, NH3, CO, CO2, O3, THC and BTEX analyser, Markaptan Analyzer, Titration/ Dilution principle, Rack mounted, Sample handling units, online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
ZERO AIR GENERATOR (Ultra high purity zero air generator unit including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
AIR COMPRESSOR UNIT Air compressor unit(Tank mount type) with drier system for shelter air requirements
METEOROLOGICAL SYSTEM (Wind speed, Wind direction, vertical wind direction, Ambient temperature, Relative humidity, Solar radiation, Solar shield, Pressure sensor, Rainfall, tower mounted, online calibration features, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
TELESCOPIC CRANK – UP METEOROLOGICAL TOWER (10 M extendable tower, grounding, lightning kit and warning lights and other requirement including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
AAQMS SHELTER (Prefabricated Shelter, split AC, safety items, furniture, tools kits, safety system with F&G Devices, Junction boxes, utilities, Fibre optic patch cords other accessories and complete with installation of tubing/ fittings as required including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
OPERATING/ ENGINEERING WORKSTATION Operating /Engineering work station present inside the shelter shall act as central monitoring station ((with Single screen display) ) inside the AAQMS shelter along with console Printer table with drawers, Chair-non revolving, chamber file cabinet for Document & other Storage, Tool kit bags with all required tools for maintenance, First aid box with first aid kits, Fire extinguisher, Industrial grade vacuum cleaner, Indoor temperature & humidity monitor
DAS SYSTEM (Data Acquisition with required software/ hardware including Packing & Forwarding, Start- up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
REMOTE CONSOLE / HMI (Remote Console / HMI(with Double screen display) with required software/ hardware at Security Building, including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
NETWORK CABINET (Network cabinets with networking devices etc including Ethernet/FO hardware and software for connecting with CPBA and PCBA and for connecting with HMI/server in security building including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
PDB CABINET PDB Cabinet 3 phase power input, with necessary terminal sizes and suitable cable glands, Lightening surge protector of suitable type and rating for all incoming power lines
WIRELESS NETWORK PROVIDER Wireless network provider shall be provided to transfer data to entry gate and other is to existing shelter(including engineering, configuration, supply of transmitter and receiver, hardware, accessories for complete transfer of data). Any coordination between wireless network as per philosophy to be taken care.
FIREWALL AND TUNNELLER (Firewall and tunneller, hardware for wireless connection etc,. for required places including Packing & Forwarding, Start-up and commissioning Spares, Documentation, FAT, Inspection and Testing, Special tools and Warranty/ Guarantee.)
SERVER Server shall be provided at admin building to store, retrieve and transfer data to other stations
Mandatory Spares as per MR TP-1ZZZA-IC-RFQ-0028 in Lumsum
Calibration and carrier gases (Calibration gases are required for six months of normal operation. Calibration cylinder design shall be considered for 1 year operation) (Lumpsum)
TPI Charges (excluding GST) for all the items including mandatory spares
Transportation Charges (excluding GST) for all the items including mandatory spares
Training 2 batch x10 people at site Per Analyser (1 engineer batch + 1 technician batch) (Lumpsum)
Training 2 NRL engineers for 5 days at OEM’s Works. . (Lumpsum)
Post commissioning operation/ maintenance support during warranty period (Periodic visits (3 visits (Mandatory) of the expert of OEM /1 no. Engineer + 1 no Technical assistant required for 3 days of each visit /OEM’s representative shall be considered for healthiness checking/ troubleshooting/Supervisory advice etc. during Warranty Period)
Supervision charges for Erection, Testing & commissioning. Per-diem rate 1 Man day of Supervision Charges on normal working days as per MR (Per Diem)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .