Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-AOC 219 HEERA NIWAS BYE PASS KATHER CHAMBAGHAT SOLAN HP 173213 | SOLAN | HIMACHAL PRADESH | 173213 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.5 L+₹76,835.53 (6.02%)Rejected-AOC 00 AGRA AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-AOC L2 |
Tender Value
₹13.4 L
EMD Value
₹27,000
Closing Date
2 Apr 2022, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE Design
o/o the Estate Officer, Dr YSP UHF Nauni, Solan HP -173230
Facelifting of first floor lobby of Administrative block at Dr YSP Universtiy of Horticulture and Forestry Nauni, Solan.
2022_YSPU_58101_2
UHF/Const. -1/Partfile/2021/-3162 dt 16.03.2022
Open Tender
Civil Works
Item Wise
60 days
Nauni
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
EE Design
₹27,000
4 May 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
2 Apr 2022
25 Mar 2022
60 days
Amount
Providing and laying Vitrified tiles double charged (Kazaria / Oreint bell / Nitco make) in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (one cement: three sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc complete in all respect as per satisfaction of Engineer-in-Charge. a). 600 X 1200mm (PGVT)
Providing and laying Vitrified tiles double charged(Kazaria / Oreint bell / Nitco make) in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). a). 600mm x 1200mm (PGVT)
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (one cement : four sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : a). Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth etc. all complete as specified and as directed by the Engineer-in-Charge.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. etc. all complete as specified and as directed by the Engineer-in-Charge.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade etc. all complete as specified and as directed by the Engineer-in-Charge. a)Two or more coats on new work
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in all lead etc. complete in all respect as per satisfaction of Engineer-in-charge.
Providing and fixing false ceiling at all heights with integral densified calciumsilicate reinforced with fibre and natural filler false ceiling tiles of Size595x595 mm of approved texture, design and patterns having NRC (NoiseReduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Lightreflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fireperformance as per BS:476 (part 6 &7), humidity resistance of 100%, thermalconductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal levelsuspended on interlocking metal T-Grid of hot dipped galvanised iron sectionof 0.33mm thick (galvanized @ 120 grams per sqm including both sides)comprising of mainT runners of size 24x38 mm of length 3000 mm, cross - Tof size 24x32 mm of length 1200 mm and secondary intermediate cross-T ofsize 24x32 mm of length 600mm to form grid module of size 600 x 600 mm,suspended from ceiling using galvanised mild steel items (galvanizing @ 80grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partitionwith the help of plastic rawl plugs at 450 mm center to center and 40 mm longdry wall S.S screws. The work shall be carried out as per specifications,drawing and as per directions of the Engineer-in-Charge. a). With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface / recessed PVC conduit and earthing the light point with 1.5 sq-mm HRFRLS / PVC insulated single core copper conductor cable as required complete in all respect as per satisfaction of Engineer-in-charge (Group – C).
Wiring for light plug with 2x1.5 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for power plug with 2x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Wiring for power plug with 4x4 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No. 4 sqmm HRFRLS / PVC insulated single core copper conductor cable for earthing as required complete in all respect as per satisfaction of Engineer-in-charge.
Rewiring for light point/ fan point/exhaust fan/ call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible ) copper conductor cable in existing surface/ recessed steel/ PVC conduit and earthing the light point with 1.5 mm HRFRLS/ PVC insulated single core copper conductor cable including dismentalling of existing wire as required (including switch and bakelite sheet etc. ) complete in all respect as per satisfaction of Engineer-in-charge Group-C
Supplying & fixing of GI modular boxes of following sizes along with modular base and cover plate for modular switches in recess as required complete in all respect as per satisfaction of Engineer-in-charge.
a) 2 module (78mm x 78mm x 50mm)
b) 4 module (140mm x 78mm x 50mm)
c) 6 module (205mm x 78mm x 50mm)
d) 8 module (120mm x 13500mm x 60mm)
e) 12 module (205mm x 135mm x 60mm)
Supplying and fixing following rating Modular switch / socket in the existing switch box/ cover plate including connections etc. as required complete in all respect as per satisfaction of Engineer-in-Charge.
a)S.P. 5/6 Amps one way modular switch
b)S.P. 15/16 Amps one way modular switch
c)5 Pin, 5/6 Amps Modular switch
d)6 Pin, 15/16 Amps Modular switch
Supplying and fixing modular blanking plate on the existing modular metal box etc. as required complete in all respect as per satisfaction of Engineer-in-Charge.
Supplying and fixing ceiling rose on the existing junction box/ wooden box including connections etc. as required complete in all respect as per satisfaction of Engineer-in-Charge.
Supplying & erection of 5/6 amps. to 32 amps. rating, 10KA breaking capacity, 240 volts, ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) Single pole. Category – A
Supplying and erection of 40/50/63 amps rating, 10KA breaking capacity, 240 volts, ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required complete in all respect as per satisfaction of Engineer-in-charge.a).Double pole Cat- A.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) 63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 millampers in the existing MCB DB complete with connections, testing and commissioning etc. as required complete in all respect as per satisfaction of Engineer-in-charge. a) 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required complete in all respect as per satisfaction of Engineer-in-charge.
a) Single door-8 way
a) Single door-12 way
Providing and fixing Toughened glass with 12mm Toughen glass as per Architectural drawing etc. complete in all respect as per satisfaction of Engineer-in-charge (All accessories will be paid for separately) (Saint Govin / Modi guard make).
Providing and fixing Toughened glass fittings of Ozone brand like handle,hinge for openable door while sensor,motorised system and scanner for automated sliding door etc complete in all respect as per satisfaction of Engineer-in-Charge (Toughened glass will be paid for separately) .
a). Single Door(1000mm x 2100mm)
b). Sliding Door with sensor(1200mm x 2100mm)
c). Toughened glass Profile SS 3.0 metre long
Providing and fixing of Garware Flim in office and meeting area complete in all respects as per architectural drawing etc. complete in all respect as per satisfaction of Engineer-in-charge
Providing & fixing MS Galvanised cable tray cover Size 150x35MM complete in all respect with best satisfaction of Engineer -in- Charge.
Providing & fixing of recess mounted luminaire including the cost of light fittings complete in all respects as per architectural drawing (make Havells / Bajaj / Usha /Great white).
a)Circular Ceiling Light 12watt(150mm x 150mm x 20mm)
b)Square Ceiling Light 36watt(600mm x 600mm x 25mm)
c)Rectangular Ceiling Light 42watt(1200mm x 300mm x 25mm)
Providing and fixing LED Cove light including cost of light fittings etc. as required complete in all respect as per satisfaction of Engineer-in-Charge.
Pawan Kumar
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .