Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹401 Cr
EMD Value
₹2 Cr
Closing Date
15 Sept 2020, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sangeeta Edwards
Power Grid Corporation of India Limited, Saudamini, 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001.
Pre Bid Tie up for Substation Package SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Open
Power/Energy Projects/Products
Works
Rajasthan & Delhi
₹25,000
₹2 Cr
15 Sept 2020
9 Jul 2020
17 Sept 2020
9 Jul 2020
15 Sept 2020
9 Jul 2020
16 Jul 2020
Name of Package Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Package No : SS01
Specification No. : TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Completion Period 15 Months
General guidelines for filling up the Attachments : Substation Package -SS01 :
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Specification No.: TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
1 Fill up only green shaded cells in the relevent attachments.
2 Attachments 4, 4(A), 4(B), 5, 6, 7, 9, 10, 11, 12, 13, 15, 16, 17,18, 19 and Bid Form for 1st Envelope are included here.
3 Attachment 1 Bid Security : To be submitted as perproforma provided in the bidding document.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 3 Bidder‟s Eligibility and Qualifications: A separate excel sheet is enclosed in volume-III.
6 Attachment 8 Manufacturer’s Authorisation Form : To be furnished as per proforma provided in the bidding document, on the letter head of the each Manufactures proposed to supply main items. Not included here.
7 Attachment 14 Integrity Pact : To be submitted as per ITB Clause No. 9.3(o) and as per remarks in the Attach 14-IP.
8 Attachment 20, 21, 22, 23, 24 and 25: Separate sheets are enclosed in Volume-III.
9 Attachment – 26: Format for this attachment is enclosed in Section-VI of Vol.-I of the bidding Documents.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
AAAAAAAABAB6 Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] 0
Name of Lead Partner
Address of Lead Partner
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any)
Any Tower Parts Manufacturer proposed other than the bidder [Yes / No] No
Proposed Tower Parts Manufacturer other than the bidder, if any [Maximum two nos.]
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-3(JV) SS01 0 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Name(s) and Addresse(s) of other partner(s)
The Joint Venture Agreement (as per the proforma attached at no. 15 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at no. 14 in Section-VI, Sample Forms and Procedures, Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Date : Printed Name : 0
Place : Designation : 15
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-3(QR) SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Qualifying Requirement Data)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
For our Qualifying Requirements Data, please refer Attachment-QR of this volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-4 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Form of Certificate of Origin and Eligibility)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby certify that equipment and materials to be supplied are produced in [Enter the name of country where from equipments & material shall be supplied] eligible source country. Equipments & Materials produced in [Name of countries] Company incorporated & registered in [Name of countries]
We hereby certify that our company is incorporated and registered in [Enter the name of country where from equipments & material shall be supplied] eligible source country.
Date : Printed Name :
Place : Designation :
country. country. [Enter the name of country where from equipments & material shall be supplied] [Enter the name of country where from equipments & material shall be supplied]
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-4(A) SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
S.No. For Equipment Item Description Unit Quantity
Notwithstanding what is stated above, we further confirm that any additional special maintenance tools and tackles, required for the equipment under this package shall be furnished by us at no extra cost to the employer.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-4(B) SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(List of Special Maintenance Tools & Tackles)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We are furnishing below the list of special maintenance tools & tackles for various equipment under the subject package. The prices for these tools & tackles which are to be taken back after the completion of the work by us are not included in our lumpsum bid price. We further confirm that the list of special maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below:
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-5 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Bought-out & Sub-contracted Items)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the details of the items/ sub-assemblies of supply or services i.e. items, whose price is more than 10% of the Bid Price, we propose to buy for the purpose of furnishing and installation of the subject Package:
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
We hereby declare that, we would not subcontract the erection portion of the contract without the prior approval of Employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e. as direct transactions) in additiona to the supplies the same from other vendors (i.e. as Bought-out transactions) as detailed in the table given above.
Sl. No. Item Description Quantity proposed to be supplied Details of the plant from where supplies are proposed.
Name of Plant Address
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Quantity proposed to be bought/sub-contracted Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Annexure I to Attachment-5 SS01
(Bought-out & Sub-contracted Items)
Sl. No. Item Description Details of the proposed sub-contractor/sub-vendor Details of the proposed sub-contractor/sub-vendor
Name Nationality
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-5(A) SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1. We hereby furnish the details of the items, components, raw material, services which we propose to buy/avail from Micro and Small Enterprises (MSEs) for the purpose of completion of works under the subject package:
S.No. Item Description Quantity proposed to be bought/sub-contracted Name of Micro and Small Enterprises (MSEs)
Name & Address Category
2. The above is a list of items we propose to procure from MSEs. However, based on the situations during the execution of the contract, the above list may undergo changes. We hereby confirm that the details regarding actual procurement from MSEs carried out by us, as per the format provided at Section VI, Forms and Procedures, Volume-I of bidding documents, shall be submitted along with the bills for payment against supplies made/works done during execution of contract. .
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-6 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Alternative, Deviations and Exceptions to the Provisions)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
The bidder shall itemize any deviation from the Specifications included in his bid. Each item shall be listed (separate sheets may be used and enclosed with this Attachment) with the following information:
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
The above deviations and variations are exhaustive. We confirm that we shall withdraw the deviations proposed by us at the cost of withdrawal indicated in this attachment, failing which our bid may be rejected and Bid Security forfeited.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Annexure I toAttachment-6 SS01
(Alternative, Deviations and Exceptions to the Provisions)
Sl. No. Reference clause in the Specifications Deviation Cost of withdrawal of the deviation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-7 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Details of Alternative Bid)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
No Alternative Bid
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-9 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Work Completion Schedule)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby declare that the following Work Completion Schedule shall be followed by us in furnishing and installation of the subject Package i.e., Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. for the period commencing from the effective date of Contract to us :
Sl. No. Description of Work Period in months from the effective date of Contract
Substation Package - SS01
1 Detailed Engineering and drawing submission
a) commencement
2 Procurement of equipment/ components & assembly
a) commencement
a) commencement
4 Manufacturing
a) commencement
5 Shipments & Delivery
a) commencement
6 Establishment of site office
7 Installation at Site
a) commencement
8 Testing & Pre-commissioning
a) commencement
9 Trial Operation
a) commencement
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New ATTACHMENT-10
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Guarantee Declaration)
Bidders's Name and Address To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We confirm that the equipment offered shall have minimum (or a maximum, as the case may be) performance specified in the Technical Specification. We further guarantee the performance/effiency of the equipments in response to the Technical Specification.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-10 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Guarantee Declaration)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that the equipments offered shall have minimum performance specified in Technical Specification. We further guarantee the performance/efficiency of the equipments in response to the Technical Specifications.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-11 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We declare that we are aware of and have gone through the “Code of Business Conduct and Ethics for Senior Management Personnel”1 and “Code of Business Conduct and Ethics for Board Members”1 of POWERGRID (hereinafter referred to as the “Code of Conduct”). We further understand that as per the “Code of Conduct”, Senior Management Personnel including Board Members, who have retired/resigned from POWERGRID, shall not accept any appointment or post, as detailed in the referred “Code of Conduct”, within 1 year from the date of cessation of service/directorship unless approved by the Competent Authority. Accordingly, we hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
*In case the date of joining in the bidder’s organization of such ex-employee is within 1 year from the date of retirement/resignation from POWERGRID, No Objection Certificate/ approval from the Competent Authority must be furnished along with the bid or subsequent through clarification pursuant to ITB Clause 21.
In case of non-submission of No Objection Certificate/approval of the Competent Authority, as required, We understand that POWERGRID shall deal with such cases as per its Policy and procedures in vogue, which may also result in rejection of our bid. We also confirm that POWERGRID shall be the sole judge in this regard. We further declare that any misrepresentation or submission of false/forged documents/information in this regard shall be dealt with as per the provisions of the Integrity Pact and/or the Bidding Documents and/or POWERGRID’s policy and procedures.
Date : Printed Name :
Place : Designation :
Note: 1. “Code of Business Conduct and Ethics for Senior Management Personnel” and “Code of Business Conduct and Ethics for Board Members” are available on POWERGRID’s website https://www.powergridindia.com. 2. The information in similar format should be furnished for each partner of joint venture in case of joint venture bid. 3. In case bidder has furnished no details on ex-employees of POWERGRID or has left blank or has indicated ‘-‘ against the same, it shall be deemed that they have not employed any such person in their organization.
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-12 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Price Adjustment Data)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We hereby furnish the relevant details pertaining to the price adjustment provisions for equipment as specified in your specifications and documents for the Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.The necessary documentary evidence are enclosed :
Sl. No. Name of Materials Value of co-efficient Name of the published index Value of index
WE HAVE QUOTED OUR BID PRICE ON FIRM PRICE BASIS.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-13 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-14 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Integrity Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4. Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
5. For further details bidders may please refer ITB Clause 9.3 (o).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
having its Registered Office at FALSE
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. Package and Specification Number TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New POWERGRID values full compliance with all relevant laws of the land, rules, regulations, economic use of resources, and of fairness / transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as under:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity, fairness and reason. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personal interest in the Companies/Agencies participating in the Bidding/Tendering process and all known prejudiced persons.
(2) If POWERGRID obtains information on the conduct of any of its employee which is a criminal offence under the IPC / PC Act , or if there be a substantive suspicion in this regard, POWERGRID will inform its Chief Vigilance Officer and in addition disciplinary actions can be initiated under POWERGRID’s Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits itself to take all measures necessary to prevent corruption. The Bidder/Contractor commits itself to observe the following principles
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
during his participation in the tender process and during the contract execution :
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which it is not legally entitled to, in order to obtain in exchange an advantage of any kind whatsoever during the tender process or during the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal or undisclosed agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor shall not pass any information provided by POWERGRID as part of business relationship to others and shall not commit any offence under PC / IPC Act.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/information in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
g) The Bidder/Contractor shall ensure adoption of Integrity Pact by its Sub-contractors and shall be responsible for the same.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may, after following due procedures, ban /blacklist the Bidder/Contractor in line with POWERGRID’s policy for “Black-Listing of Firms / Banning of Business”. The imposition and duration of the ban will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The ban will be imposed for a maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the ban prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID is entitled for forfeiture of the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III or if POWERGRID is entitled to terminate the contract under Section III, POWERGRID shall be entitled to forfeit the Contract Performance Guarantee of this contract, in full or part thereof as may be decided, besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall disclose in its Bid any transgressions occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country, that may impinge on the Anti-corruption principle.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, it can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason and further action can be taken in line with POWERGRID’s policies.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India. The names of the IEMs have been indicated in the Bidding Documents.
(2) The panel of IEMs shall review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. The panel of IEMs has right of access to all project documentation. The panel of IEMs may examine any complaint received by them and submit a report to Chairman-cum-Managing Director, POWERGRID, giving joint findings, at the earliest. The panel of IEMs may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) TThe IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He / She reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his / her request and demonstration of a valid interest, unrestricted and unconditional access to their documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEMs information as sought by him / her which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract. The IEMs shall also sign declaration on ’Non-Disclosure of Confidential Information’ and of ‘Absence of Conflict of Interest’. In case of any conflict of interest arising at a later date, the IEM shall inform Chairman-cum-Managing Director, POWERGRID and recuse himself/herself from that case.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he / she will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under PC / IPC Act, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) While representing any matter in relation to the Integrity pact inter-alia including its transgression to the panel of IEMs, POWERGRID and Bidder/Contractor shall not approach the court of law and await the decision of the IEM in the matter..
(10) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing. Side agreements have not been made.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Issues like Warranty/Guarantees etc. shall be outside the purview of IEMs.
(6) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(7) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 2 : Witness 2 :
Designation : Designation :
Integrity Pact Page 8 of 8
Integrity Pact Page 8 of 8
Specification No.: TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-15 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
Bidder’s Name and Address (Sole Bidder) : Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29 YES
Gurgaon (Haryana) - 122001 NO
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Initial Advance
Supply Portion:
Services Portion:
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made 0
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3.(a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3.(b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement poliy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidenec is to be attached. Please refer remarks at the end of the attachment.
3.(c) If 3.(b) is 'Yes' please mention whether you are (Proprietary MSE/Partnership MSE/Private Limited Company) owned by SC/ST entrepreneurs.
3.(d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No) Note: Documentary evidence is to be attached.
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
10. PF Regional Office covered (with Address)
11. Name of Contact Person
12. Contact Details
13. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
14. 9 digit MICR code printed at bottom in middle, next to cheque no.
15. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
* The definition of MSEs owned by SC/ST is as given under:
(a) In case of Proprietary MSE, Proprietor(s) shall be SC/ST.
(b) In case of partnership MSE, then SC/ST partners shall be holding at least 51% shares in the unit.
(c) In case of Private Limited companies, at least 51% shares shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : 00-Jan-00 Printed Name : 0
Place : 0 Designation : 0
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-16 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Additional Information)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (q) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
1.0 The Bidder shall furnish
A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(q)(i)]
1.1 In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of Bidder (Lead Partner)
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
1.2 The Bidder should accordingly also provide the following information/documents
(i) Details of Banker:
Address of Banker
Contact Name and Title
(ii) As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
(iii) As per para BDS/ITB clause 9.3 q, Bidder shall furnish the details of their Provident Fund Code Number
Sl. No. Name of Bidders/JV Partners Provident Fund Code Number Details
2.0 Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(q)(ii)]
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.0 Details regarding previous transgressions of Integrity Pact
The bidder should provide detailed information on any transgression of Integrity Pact that occurred in the last 10 years with any other Public Sector Undertaking or Government Department or any other Company, in any country.
3.1 Details regarding previous transgressions of Integrity Pact that occurred in the last 10 years:
Year Name of client Details of Transgression of Integrity Pact by the bidder
5.0 OTHER INFORMATION
5.1 Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Additional Information)
Name(s) and Addresse(s) of other partner(s)
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference):
The Bidder shall furnish
1.1 A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3(p)(i)]
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
(i) The Bidder should accordingly also provide the following information/documents
Details of Banker:
Address of Banker
Contact Name and Title
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid. [Reference ITB clause 9.3(p)(ii)]
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.1 OTHER INFORMATION
Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Additional Information)
Name(s) and Addresse(s) of other partner(s)
Name : Contract Services
Address : Power Grid Corporation of India Ltd.,
"Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the additional information required as per ITB Sub-Clause 9.3 (p) of the Bidding Documents, we furnish herewith our data/details/documents etc., alongwith other information, as follows (the stipulations have been reproduced in italics for ready reference): Reference ITB clause 9.3(p)(ii)
The Bidder shall furnish
1.1 A certificate from their Banker(s) (as per prescribed formats in Form 16, Section-VI: Sample Forms and Procedures) indicating various fund based/non fund based limits sanctioned to the Bidder and the extent of utilization as on date. Such certificate should have been issued not earlier than three months prior to the date of bid opening. Wherever necessary the Employer may make queries with the Bidders’ Bankers. [Reference ITB clause 9.3 (p)(i)]
In accordance with 1.0, certificate(s) from banker as per requisite format, indicating various fund based/non fund based limits sanctioned to the bidder or each member of the joint venture and the extent of utilization as on date is/are enclosed, as per the following details:
Name of the Banker by whom certificate issued
Date of certificate (should not be earlier than 3 months prior to date of bid opening)
Whether fund based/non fund based limits are indicated in the certificate
Whether extent of utilization is indicated in the certificate
(i) The Bidder should accordingly also provide the following information/documents
Details of Banker:
Name of Banker `
Address of Banker
Contact Name and Title
As per para 1.0, Authorization Letter(s) from the bidder (in case of JV bidder, from all the partners) addressed to the Banker(s), authorizing POWERGRID to seek queries about the bidder with the Banker(s) and advising the Banker(s) to reply the same promptly, is/are enclosed as per following details:
Sl. No. Letter Ref. Date Addressed to (name of the Bank)
Litigation History
2.1 The bidder should provide detailed information on any litigation or arbitration arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder or any partner of JV may result in rejection of Bid.
Details of litigation history resulting from Contracts completed or under execution by the bidder over the last five years
Year Name of client, cause of litigation/arbitration and matter in dispute Details of Contract and date Award for or against the bidder Disputed amount
3.1 OTHER INFORMATION
Current Contract Commitments of works in progress
Bidders (individual firms or each partners of JV) should provide information on their current commitments on all contracts that have been awarded, or for which a letter of intent or acceptance has been received, or for contracts approaching completion, but for which an unqualified, full completion certificate has yet to be issued.
Details of Contract Value of outstanding work (Rs.) Estimated completion date
Financial Data:
Details Actual (Previous five years) Projection for next five years
Total Liability
Current Liability
Profit before taxes
Profit after taxes
Place : Printed Name :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-17 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Lead Partner) : To:
0 Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
1 We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us.
2 We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-17 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
0 Contract Services
Name : …… ……. …….. …… ……. …….. Power Grid Corporation of India Ltd.,
Address : …… ……. …….. …… ……. …….. "Saudamini", Plot No. 2, Sector 29
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-17 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Name(s) and Addresse(s) of other partner(s) To:
0 Contract Services
Name : 0 Power Grid Corporation of India Ltd.,
Address : 0 "Saudamini", Plot No. 2, Sector 29
0 Gurgaon (Haryana) - 122001
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-18 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Safety Pact is annexed herewith this Volume.
Date : Printed Name :
Place : Designation :
Specification No. :TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Attachment-19 SS01
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
Further, we hereby confirm that except as mentioned in the Attachment – 6 (Alternative, Deviations and Exceptions to the Provisions) hereof forming part of our First Envelope :
Date : Printed Name :
Place : Designation :
Specification No TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Bid Form 1st Envelope 1 one 1 st 1 January
2 two 2 nd 2 February
BID FORM (First Envelope) 3 three 3 rd 3 March
4 four 4 th 4 April
Bid Proposal Ref. No. 5 five 5 th 5 May
Date : 6 six 6 th #VALUE! 6 June
7 seven 7 th #VALUE! 7 July
To: 8 eight 8 th #VALUE! 8 August
Contract Services 9 nine 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 ten 10 th 10 October
"Saudamini", Plot No. 2, Sector 29 11 eleven 11 th 11 November
Gurgaon (Haryana) - 122001 12 twelve 12 th 12 December
13 thirteen 13 th
14 fourteen 14 th
Name of Contract : Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. 15 fifteen 15 th
Dear Ladies and/or Gentlemen, Enter details here. 16 sixteen 16 th
1.0 Having examined the Bidding Documents, including Amendment Nos. ...[Enter the Amendment]… dated …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). ...[Enter the Amendment]… …[Enter the Date in dd-mm-yyyy]… the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
2.0 Attachments to the Bid Form (First Envelope) Bank Draft 18 eighteen 18 th
In line with the requirement of the Bidding Documents, we enclose herewith the following Attachments: Enter details here. Pay Order 19 nineteen 19 th
OR Online Payment acknowledgement towards Bid Security for a sum of INR
OR documentary evidence in support of exemption of Bid Security, in separate envelope in accordance with clause 13.1 of ITB, Section-II
(b) Attachment 2(SS01) : A power of attorney duly authorized by a Notary Public indicating that the person(s) signing the bid have the authority to sign the bid and thus that the bid is binding upon us during the full period of its validity in accordance with the ITB Clause 14. Bank Guarantee (0) 21 st
(c) Attachment 3(SS01) : The documentary evidence that we are eligible to bid in accordance with ITB Clause 2. Further, in terms of ITB Clause 9.3 (c) & (e), the qualification data has been furnished as per your format enclosed with the bidding documents Attachment-3(QR). 0 22 th
Further, the required Joint Venture Agreement signed by us and our Partners has also been furnished as per your format Attachment-3(JV). 0 0 Applicable 23 th
Further the required deed of Joint Undertaking signed by us and GIS Manufacturer has also been furnished as per your format. Not Applicable 24 th
(d) Attachment 4(SS01) : The documentary evidence establishing in accordance with ITB Clause 3, Vol.-I of the Bidding Documents that the facilities offered by us are eligible facilities and conform to the Bidding Documents has been furnished as Attachment 4. A list of Special Tools & Tackles to be used by us for erection, testing & Commissioning and to be handed over to Employer, the cost of which is included in our Bid Price, is also enclosed as per your format as Attachment 4A. A list of Special Tools & Tackles to be brought by the contractor for erection, testing & Commissioning and to be taken back after completion of work, whose cost in not included in our bid price, is enclosed as per your format as Attachment 4B. 25 th
(e) Attachment 5(SS01) : The details of all major items of services or supply which we propose subletting in case of award, giving details of the name and nationality of the proposed subcontractor/sub-vendor for each item. 26 th
(f) Attachment 5A(SS01) : (Items, Components, Raw Material, Services proposed to be sourced from Micro and Small Enterprises): The details of the items, components, raw material, services which is proposed to bought/availed from Micro and Small Enterprises for the purpose of completion of works.
(g) Attachment 6(SS01) : The variation and deviations from the requirements of the Conditions of Contract, Technical Specification and Drawings (excluding critical provisions as mentioned at clause 6.0 below) in your format enclosed with the Bidding Documents, including, inter alia, the cost of withdrawal of the variations and deviations indicated therein. 27 th
(h) Attachment 7(SS01) : The details of Alternative Bids made by us indicating the complete Technical Specifications and the deviation to contractual and commercial conditions. (Not Applicable) 28 th
(i) Attachment 8(SS01) : Manufacturer’s Authorisation Forms. 29 th
(j) Attachment 9(SS01) : Work Completion Schedule. 30 th
(k) Attachment 10(SS01) : Guarantee Declaration. 31 st
(l) Attachment 11(SS01) : Information regarding ex-employees of Employer in our firm.
(m) Attachment 12(SS01) : Filled up information regarding Price Adjustment Data as per the format enclosed in the bidding documents.
(n) Attachment 13(SS01) : Declaration regarding Social Accountability.
(o) Attachment 14(SS01) : Integrity Pact, in a separate envelope, duly signed on each page by the person signing the bid.
(p) Attachment 15(SS01) : Option for Initial Advance (either Interest Bearing Initial Advance or No Initial Advance) and Information for E – payment, PF details and declaration for Micro/Small and Medium Enterprise
(q) Attachment 16(SS01) : Additional Information.
(r) Attachment 17(SS01) : Declaration for tax exemptions, reductions, allowances or benefits
(s) Attachment 18(SS01) : Safety Pact
(t) Attachment 19(SS01) : Declaration
(u) Attachment 20(SS01) : Declaration of Key Managerial Person jointly with Power of Attorney holder
(v) Attachment 21(SS01) : Authorization certificate issued by Domestic Manufacturer for selling Domestically Manufactured Iron & Steel Products, if applicable
(w) Attachment 22(SS01) : Affidavit of Self certification regarding Domestic Value Addition in Iron & Steel Products
(x) Attachment 23(SS01) : Affidavit
(y) Attachment 24(SS01) : Confirmation in regard to Design and Type Test as per QR (To be furnished in case bidder is proposing to qualify through Note-4 under Route -1 of QR)
(z) Attachment 25(SS01) : Declaration by the Bidder regarding events encountered pursuant to ITB Clause 2.1.
(aa) Attachment 26(SS01) : Confirmation regarding furnishing Declaration regarding Non-Participation as a Bidding Company or as a member of any Bidding Consortium in Transmission Project under Tariff Based Competitive Bidding Route (as per Form No. 24, Section-VI of Vol.-I of the bidding Documents).
3.0 We are aware that, in line with Clause No. 27.1 (ITB), our Second Envelope (Price Part) is liable to be rejected in case the same contains any deviation/omission from the contractual and commercial conditions and technical Specifications other than those identified in this First Envelope.
3.0 A * (applicable for MSE only) We are a Micro and Small Enterprise (MSE) registered with................, a designated Authority of GoI under the Public Procurement Policy for MSEs order 2012. Delete if not applicable
4.0 We confirm that except as otherwise specifically provided our Bid Prices in Second Envelope include all taxes, duties, levies and charges as may be assessed on us, our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
4.1 100% of applicable Taxes and Duties i.e. GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
4.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
5.0 Construction of the Contract
5.1 We declare that we have studied Clause GCC 2.1 relating to mode of contracting for Domestic Bidders and we are making this proposal with a stipulation that you shall award us two separate Contracts viz ‘First Contract’ for ex-works supply of all equipment and materials including mandatory spares and ‘Second Contract’ for providing all the services i.e. inland transportation for delivery at site, insurance, unloading, storage, handling at site, installation, testing and commissioning including Trial operation in respect of all the equipment supplied under the ‘First Contract’ and other services specified in the Contract Documents. We declare that the award of two contracts, will not, in any way, dilute our responsibility for successful operation of plant/equipment and fulfillment of all obligations as per Bidding Documents and that both the Contracts will have a cross-fall breach clause i.e. a breach in one Contract will automatically be classified as a breach of the other contract which will confer on you the right to terminate the other contract at our risk and cost.
6.0 We have read the provisions of following clauses and confirm that the specified stipulations of these clauses are acceptable to us:
(a) ITB 13 Bid Security
(b) GCC 2.14 Governing Law
(c) GCC 5.1 Contractor’s Responsibilities
(d) GCC 8 Terms of Payment
(e) GCC 9.3 Performance Security
(f) GCC 10 Taxes and Duties
(g) GCC 21.2 Completion Time Guarantee
(h) GCC 22 Defect Liability
(i) GCC 23 Functional Guarantee
(j) GCC 25 Patent Indemnity
(k) GCC 26 Limitation of Liability
(l) GCC 38 Settlement of Disputes
(m) GCC 39 Arbitration
(n) Appendix 2 to Form of Contract Agreement Price Adjustment
Further we understand that deviation taken in any of the above clauses by us may make our bid non-responsive as per provision of bidding documents and be rejected by you.
7.0 We have noted the provisions of the Bidding Documents that POWERGRID intends to participate in the selection of Transmission Service Provider (TSP) for the "Transmission Scheme for evacuation of power from Solar Energy Zones in Rajasthan (8.1 GW) under phase II –Part G” through Tariff Based Competitive Bidding (TBCB) Route. For this purpose, the bids have been invited by POWERGRID for the subject Package covering certain scope of work under the aforesaid TBCB Project. The qualified, lowest evaluated Bidder having requisite capacity and capability to perform the contract for the aforesaid Package(s) as per the provisions of the Bidding Documents shall be pre-selected, for the scope of work contained in the Bidding Documents, for associating with POWERGRID for the purpose of tariff bidding by POWERGRID in the RfP process of the BPC for the subject Project under TBCB route and, in case POWERGRID becomes successful Bidder, the successful Bidder for aforesaid mentioned Package(s) will be awarded the Contract for execution of scope of work contained in the Bidding Documents. An MOU shall be signed with the pre-selected Bidder prior to tariff bid submission by POWERGRID to BPC against its RfP process. This MOU shall, inter-alia, bind both POWERGRID and the pre-selected Bidder for associating on exclusive basis and maintaining strict confidentiality by the pre-selected Bidder of the prices, terms and conditions.
7.1 We undertake, if our bid is accepted, to commence the work immediately upon your Notification of Award to us, and to achieve the delivery of goods and related services within the time stated in the Bidding Documents.
8.0 If our bid is accepted, we undertake to provide a Performance Security in the form and amounts, and within the times specified in the Bidding Documents.
9.0 We agree to abide by this bid for a period of Six (06) months from the date fixed for opening of bids as stipulated in the Bidding Documents, and it shall remain binding upon us and may be accepted by you at any time before the expiration of that period.
10.0 Until a formal Contract is prepared and executed between us, this bid, together with your written acceptance thereof in the form of your Notification of Award shall constitute a binding contract between us.
11.0 We understand that you are not bound to accept the lowest or any bid you may receive.
12.0 Commissions or gratuities, if any, paid or to be paid by us to agents relating to this Bid, and to contract execution, if we are awarded the contract, are listed below:-
Name and address of agent Amount and Currency Purpose of Commission or gratuity
(If none, state “none”)
13.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
14.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him
Other Partner -1 Other Partner -2
Printed Name : Printed Name :
Designation : Designation :
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2(SS01) Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Attachment-3(QR)
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
SPECIFICATION No. : TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
(Qualifying Requirement Data)
Bidders’s Name & Address: Contract Services
Name: Power Grid Corporation of India Ltd.,
Address: "Saudamini", Plot No. 2, Sector 29
Gurgaon (Haryana) - 122001
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & Additional Information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details along with other information, as follows herewith our stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail).
* We have submitted bid as individual firm.
* We have submitted bid as joint venture of following firms :
(* Strike-off whichever is not applicable)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents defining :
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
B Attached original & copies of the following documents :
a) Written power of attorney of the signatory of the Bid to commit the bidder.
b) Joint Venture Agreement.
GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars Bidder/Lead Partner In case of Joint Venture
For Other Partner(s) For Other Partner(s)
1 Name of the Firm
2 Head Office/ Registered Office Address
5 Contact Person
6 Place of Incorporation/ Registration
7 Year of Incorporation/ Registration
8 Nationality of
1.0 TECHNICAL REQUIREMENTS {Reference para 1.0 of Annexure-A (BDS)}
TECHNICAL EXPERIENCE
1.1 Route-1: The Bidder must have designed, manufactured, tested (as per IEC or equivalent standard), supplied and supervised erection & commissioning of at least two (2) nos. GIS Circuit Breaker bays* of 715 kV or above voltage class in one (1) Substation or Switchyard and these bays must be in satisfactory operation# for at least One (1) year as on the originally scheduled date of bid opening i.e.27/07/2020
2.1.1 In case the Bidder is a Foreign Entity, following requirements shall be complied:
i (i) If the bidder is submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, the bidder must, in its bid, propose an Indian Associate for executing the On-Shore Supply and On-Shore Services Contract, as per the provisions of bidding documents. The proposed Indian Associate must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays of 345kV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above For executing on-shore supply contract, the bidder in its bid, may alternatively propose its Indian Subsidiary or Group or Joint Venture Company as Indian Associate provided that the proposed Indian Associate has been registered in India (as per Companies Act 1956 or 2013 of India) for establishing manufacturing and testing facilities for 765kV GIS or above voltage level as on the date of bid opening mentioned above.
ii A) The Subsidiary or Group Company or a Joint Venture Company (JVC) of the bidder shall have manufacturing & testing facilities for 765kV or above voltage level GIS in India as on the originally scheduled date of bid opening mentioned above. OR The bidder must have incorporated a Subsidiary or Group Company or a Joint Venture Company (JVC) as per Companies Act 1956 or 2013 of India, to manufacture 765kV or above voltage level GIS in India and it must have commenced the construction activities for establishment of 765kV or above voltage level GIS manufacturing and testing facilities in India as on the originally scheduled date of bid opening mentioned above. B) The bidder must supply at least one (1) no. 765kV GIS Circuit breaker bay* manufactured in the said facilities in India, for which Bidder shall furnish an undertaking (as per enclosed format in Volume-III of Bidding Document) along with the bid. C) Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from Indian works of its Subsidiary or Group Company or a Joint Venture Company (JVC) provided the Subsidiary/JVC/Group Company must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay should have been either supplied or type tested (as per IEC or equivalent standard) as on the originally scheduled date of bid opening mentioned above.
1.2 Route-2: The Bidder, who has established manufacturing & testing facility in India for 765kV or above voltage level GIS but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that: a) The bidder must have manufactured at least one (1) no. 765KV or above voltage level GIS Circuit Breaker bay* based on the technological support of the Collaborator(s), provided that the Collaborator(s) meets the requirement stipulated in para 1.1 above. Further, the bidder must have either supplied or type tested the above 765kV GIS bay (as per IEC) as on the originally scheduled date of bid opening mentioned above. b) The bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the Collaborator(s)) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); ii. A confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 765kV GIS equipment in India. .
1.3 Route-3: The Bidder, who has established manufacturing & testing facility in India for 765kV or above voltage level GIS as Subsidiary/JVC/Group company by its parent/principal but not meeting the requirement stipulated in para 1.1 above, shall also be considered provided that- a) The bidder must have manufactured at least one (1) no. 765KV or above voltage level GIS Circuit Breaker bay* based on the technological support of the parent/principal company, provided that the parent/principal meets the requirement stipulated in para 1.1 above. Further, the bidder must have either supplied or type tested the above 765kV GIS bay (as per IEC) as on the originally scheduled date of bid opening mentioned above. b) The bidder shall also submit the following along with the bid: i. A legally enforceable undertaking (jointly with the parent/principal company) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s); ii. A confirmation letter from the parent/principal company stating that they shall furnish performance guarantee for an amount of 10 % of the ex-works cost of such equipment(s). This performance guarantee shall be in addition to Contract Performance Guarantee to be submitted by the bidder. iii. A valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 765kV GIS equipment in India.
1.4 Route-4: In case, the bidder is not a GIS manufacturer, he shall also be considered provided: i. The bidder must have erected and commissioned at least two (02) nos. GIS circuit breaker bays of 765kV or above voltage class in one (01) new GIS substation or switchyard during last seven (07) years and these bays must be in satisfactory operation# for at least two (02) years as on the originally scheduled date of bid opening mentioned above. ii. The GIS must be offered from Indian manufacturer, who meets the requirement mentioned at Route-1 or Route-2 or Route-3 above. iii. A legally enforceable undertaking (jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Volume-I of bidding document) to guarantee quality, timely supply, performance and warranty obligations as specified for the equipment(s) is submitted along with the bid stating that GIS Manufacturer shall furnish performance guarantee for an amount of two (2) % of the total contract price. This performance guarantee shall be in addition to the Contract Performance security to be submitted by the Bidder.
Note :- 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. * For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. In case bidder is a holding company, the technical experience referred to in Route-1, 2, 3 and 4 above as the case may be, shall be of that holding company only (i.e. excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, the technical experience referred to in Route-1, 2, 3 and 4 above as the case may be, shall be of that subsidiary company only (i.e. excluding its holding company). 4. In case bidder is an Indian entity and qualifying through Route-1, type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents.
Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the experience as detailed above, on the basis of which the Bidder wishes to qualify. The information is to be summarised using following format for each experience of the Bidder or of each Partner of a Joint Venture.
(The bidder shall attach documentary evidence, such as copies of utility certificates for completed contracts and copies of award letters etc. for ongoing contracts in support of his experience as listed in the following proforma for each Contract with the help of "Attach" Buttons provided in table given below).
Format for the Bidder/ Lead Partner/ Partners of JV in case of Joint Venture/Indian GIS Mnaufacturer in support of meeting the requirement of para 1.1, Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name : #REF!
Single Firm/Lead Partner/Other Partners of a JV/Indian GIS Mnaufacturer #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 715kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 715 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
NOTE: type test reports of Collaborator/ Parent Company/ Subsidiary Company/ Group Company shall also be acceptable, for which a confirmation shall be furnished along with the bid as per format attached in the bidding documents (Attachment-24 in Volume-III)
In case of foreign entity, whether bidder have established/ commence the establishment of facility as Indian Subsidiary/ Group Company/ Joint Venture Company for manufacturing & testing of 765kV or above voltage level GIS in India (as per Companies Act 1956 or 2013 of India)
Whether bidder want to propose its above subsidiary/ Group Company/ Joint Venture Company as its associate for executing On-Shore Supply Contract
Foreign Bidder can offer to supply more than one 765kV GIS circuit breaker bay* from India provided his Subsidiary or Group Company or a Joint Venture Company (JVC) must have manufactured at least one (1) number 765kV or above voltage level GIS Circuit Breaker bay* and this bay either should have been supplied or should have been type tested ( as per IEC or equivalent standard) as on the originally scheduled date of bid opening as mentioned above
Whether Undertaking (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
Format for the Indian Associate executing the On-Shore Supply and On-Shore Services Contract for a Foreign Entity submitting its bid as an Individual Firm or in a Joint Venture without any Indian Entity as a Partner, in support of meeting the requirement of para 1.1.1(i) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Associate executing the On-Shore Supply and On-Shore Services Contract
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the Bidder
4 No. of GIS/AIS Circuit Breaker equipped bays under the contract
(Indicate nos. of Circuit Breaker equipped bays of 345 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
No. of years, the above CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2 (Route-2) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian Bidder not meeting the requirement stipultaed in Clause 1.1 of Annexure-A (BDS), but has established manufacturing and testing facilities in India for 765kV or above Gas Insulated Switchgear (GIS):
1 Whether 765kV or above voltage level GIS Circuit Breaker bay manufactured by bidder have been supplied or Type tested
A if Type tested, details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 765kV or above voltage level GIS bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom 765kV or above voltage level GIS bays were supplied by the Bidder
iv No. of 7655kV or above GIS Circuit Breaker bays under the contract
Name of the substation or switchyard
Whether 765kV or above voltage level GIS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Collaborator under the Contract.
If Yes, indicate the Name of Collaborator(s)
No. of years, the above GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 345kV or above GIS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.2(Route-2) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Collaborator (refer para 1.2), if applicable : #REF!
Name of the 715kV or above GIS Equipment Manufacturer (refer para 1.2), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) No. of 715kV or above GIS Circuit Breaker bays under the above contract
(Indicate nos. of GIS Circuit Breaker bays of 715kV or above where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above GIS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 715kV or above GIS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.2 of Annexure-A (BDS)
Whether confirmation letter from the Collaborator(s) stating that the Collaborator(s) shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.2 of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 765kV or above GIS equipment in India has been enclosed with bid (in line with para 1.2 of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3 (Route-3) of Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Indian established as Subsidiary/JVC/Group company by its parent/principal
Whether bidder have established manufacturing and testing facilities in India for 765kV or above voltage level GIS
1 Whether 765kV or above voltage level GIS Circuit Breaker bay manufactured by bidder have been supplied or Type tested based on Technological support of their Parent/ Priincipal Company
A if Type tested, details of Type test Report
B Details of GIS supplied by them
i Name of Contract Undertaken for manufacturing 765kV or above voltage level GIS bays
ii Contract Reference No. & Date of Award
iii Name and Address of the Employer/Utility for whom 765kV or above voltage level GIS bays were supplied by the Bidder
iv No. of 765kV or above GIS Circuit Breaker bays under the above contract
Name of the substation or switchyard
Whether 765kV or above voltage level GIS Circuit breaker bays, as mentioned above, has been manufactured based on technological support of the Parent/ Principal Company under the Contract.
If Yes, indicate the Name of Parent/ Principal Company(s)
No. of years, the above AIS/GIS Subatation(s) are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract for the above 765 GIS bay as per IEC as on the originally scheduled date of bid opening
(Tick whichever is/are applicable)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.3(Route-3) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Name of the Parent Company/ Principal (refer para 1.3), if applicable: 0 #REF!
Name of the 715kV or above voltage level GIS Equipment Manufacturer (refer para 1.3), if applicable : #REF!
1 Name of Contract Undertaken #REF!
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
4(a)(i) No. of 715kV or above GIS Circuit Breaker bays under the above contract
(Indicate nos. of GIS Circuit Breaker bays of 715kV or above where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above GIS CB bays are in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract as per IEC
(Tick whichever is/are applicable)
Whether Joint Deed of Undertaking executed between The Bidder and 715kV GIS Equipment Manufaturer has been enclosed with bid ? (in line with para 1.3 of Annexure-A (BDS)
Whether confirmation letter from the parent/principal company stating that the parent/principal company shall furnish performance guarantee for an amount of 10% of the ex-works cost of such equipment(s) has been enclosed with bid? (in line with para 1.3 of Annexure-A (BDS)
Whether valid collaboration agreement for technology transfer / license to design, manufacture, test and supply 765kV GIS equipment in India has been enclosed with bid ? (in line with para 1.3 of Annexure-A (BDS)
Details of documents uploaded in support of the above stated experience
Format in support of meeting the requirement of para 1.4(Route-4) (as applicable) Annexure-A to BDS, Section-III, Volume-I of the Bidding Documents)
Bidder’s Name :
1 Name of Contract Undertaken
2 Contract Reference No. & Date of Award
3 Name and Address of the Employer/Utility for whom the Contract was executed by the firm
4(a)(i) Voltage Level of GIS Substation commissioned under the Contract (Indicate 765kV or above class only)
No. of GIS Circuit Breaker equipped bays under the above contract
(Indicate nos. of GIS Circuit Breaker equipped bays of 765 kV or above voltage level where one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs)
Name of the substation or switchyard
(a)(ii) No. of years, the above Substation have been in operation as on the originally scheduled date of bid opening.
Scope of work involved under the Contract
(Tick whichever is/are applicable)
Whether Undertaking (Jointly with the GIS Manufacturer) (as per enclosed format in Section-VI, Sample Forms and Procedures of bidding document) for above is enclosed with the bid
Details of documents uploaded in support of the above stated experience
2.0 FINANCIAL REQUIREMENTS :
Financial Position {Reference para 2.0 of Annexure-A (BDS)} For the purpose of this particular bid, bidders shall meet the following minimum criteria:
a) Net Worth for last 3 financial years should be positive
b) Minimum Average Annual Turnover^ (MAAT) of the bidder for best three years i.e. 36 months out of last five financial years of the bidder should be Rs. 4812 million or equivalent.
^Note- “Annual gross revenue from operations/gross operating income as incorporated in the profit & loss account excluding other income”.
For Bidders to qualify for more than one package, their financial position shall not be less than the sum of the requirement for the packages they propose to qualify for ( strike through if only one package)
c) Bidder shall have Liquid Assets (LA) and/or evidence of access to or availability of credit facilities of not less than Rs. 802 million or equivalent.
Note: (i) In case bidder is a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of holding company only (i.e. excluding its subsidiary / group companies). In case bidder is a subsidiary of a holding company, the Financial Position criteria referred to in para 2.0 above shall be that of subsidiary company only (i.e. excluding its holding company). (ii) In case bidder has established manufacturing facility in India and yet to complete three (3) financial years, the Net Worth and average of the turnover as per financial statement for completed financial years shall be considered for the purpose of compliance to the specified Net Worth and MAAT requirements. (iii) In case of bidder qualifying through Route-3 but not meeting the Financial Position requirement as per note (i) read along with note (ii) above, the following shall be applicable: In case bidder is yet to complete five (5) years from the date of commercial production of such equipment(s) as on the originally scheduled date of bid opening as above, the financial position requirement as per para 2.0 (b) & (c) of parent/principal company providing collaboration for technological support shall be considered. However, once he completes five (5) years from the date of commercial production of such equipment (s) in India as on the originally scheduled date of bid opening as above, the financial position requirements as specified at 2.0 (b) and (c) above shall also be required to be met by such bidder on their own as per note (i) above and not based on their parent/principal company. Further, in case the bidder is yet to complete one (1) financial year, the Net worth requirement as per para 2.0 (a) above of parent/principal shall be considered. (iv) Relaxation for Start-Ups^/ MSEs Start-Ups^/ MSEs, meeting the specified requirements at Para 2.0 (a) above in Financial Position shall also be considered qualified if they meet Eighty (80) % of the requirement specified at Para 2.0 (b) & 2.0 (c) above in Financial Position. ^ Start-Ups as defined by DIPP, applicable as on the originally scheduled date of bid opening.
{In support of its ‘Financial Position’, in line with the above, the Bidder (in case of bidding by single firm ) or each of the Partners of a Joint Venture (in case of bidding by a Joint Venture) or Company/Constituents must provide the relevant information in support of the same, along with documentary evidence, in the following format}
3.0 Financial Qualification Data: 2 or more
Name of the Bidder
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2019-20
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2019-20
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-1 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2019-20
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2019-20
C Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Name of Other Partner-2 of JV
Details of documentary evidence submitted in support of Qualification Data
Networth (in Rs. Millions)
Sl No Financial year
Do you have audited results for FY 2016-17 Yes
Do you have audited results for FY 2019-20
B Turnover details:
Details of documentary evidence submitted in support of Qualification Data
Turnover (in Millions)
Sl No Financial year
Do you have audited results for FY 2019-20
Average Annual Turnover for best Three Years is
C Liquid Assets
LA (in Rs. Million)
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
4.0 Joint Venture (JV) Firms {Reference para 3.0 of Annexure-A (BDS)}
a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, all the partners of Joint Venture shall meet collectively the complete requirements stipulated at para 1.0 and 2.0 (b) & (c) above. Further, the partner(s) of JV must also meet the following minimum criteria: i. All the partners of the JV shall meet individually the Financial Position criteria given at 2.0 (a) above. ii. The Lead Partner shall meet, not less than 40% of the minimum Financial Position$ criteria given at para 2.0 (b) & (c) iii. Each of the other partner(s) individually shall meet not less than 25% of the minimum Financial Position$ criteria given at para 2.0 (b) & (c) above The figure of average annual turnover and liquid assets/credit facilities for each of the partners of the JV shall be added together to determine the JV’s compliance with the minimum qualifying criteria set out in Para 2.0 (b) & (c) above.
b) However, for a JV to be qualified, the partners of JV must also meet the following minimum criteria: i. One of the partner(s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above ii. The remaining partner (s) of JV must meet the Technical Experience criteria and the requirements stipulated under Route-1 or Route-2 or Route-3 as per para 1.0 above OR must have erected, tested and commissioned at least two (2) nos. GIS/AIS Circuit Breaker equipped bays* of 345kV or above voltage level in one (1) substation or switchyard during the last seven (7) years and these bays must be in satisfactory operation# as on the originally scheduled date of bid opening mentioned above.
In case of Joint venture, the following conditions shall also apply:
(a) the bid, and in case of successful bid, the specified Form of Agreement shall be signed so as to be legally binding on all partners (as per enclosed format in Section-VI, Vol.-I of bidding document).
(b) one of the partners shall be nominated as Lead Partner, and the Lead Partner shall be authorized to incur liabilities and receive instructions for and on behalf of any and all partners of the Joint Venture, and the entire execution of the Contract shall be done with the Lead Partner and payment under the contract shall be received by the Lead Partner on behalf of the Joint Venture as per power conferred to him in the Power of Attorney. The authorization shall be evidenced by submitting a Power of Attorney signed by legally authorized signatory of all the partners as per Performa in in Section-VI, Vol.-I of bidding documents. The payment under the Contract can also be received by other partner(s) based on authorization of Lead Partner.
(c) All partners of the joint venture shall be liable jointly and severally for the execution of the Contract in accordance with the Contract terms and a statement to this effect shall be included in the authorisation mentioned under (b) above as well as in the Bid Form and in the Contract Form (in case of a successful bid);
(d) Agreement entered into by the Joint Venture partners shall be submitted with the bid.
Note: 1. (#) Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark. 2. (*) For the purpose of qualifying requirement, one no. of circuit breaker bay shall be considered as a bay used for controlling a line or a transformer or a reactor or a bus section or a bus coupler and comprising of at least one circuit breaker, one disconnector and three nos. of single phase CTs / Bushing CTs. 3. ($) In case of a JV bid involving an Indian Entity qualifying through Route-3 and its parent/ principal company as partner(s), the Indian Entity shall meet the applicable Financial Position criteria on its own and not based on its parent/principal company
The bidder shall furnish documentary evidence in support of the qualifying requirement stipulated as above.
4.1 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the documents are submitted alongwith the bid. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents furnished are to be indicated below :
A For Name of the Bidder
B For Name of Other Partner-1 of JV
C For Name of Other Partner-2 of JV
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 9.3 (c)}
5.1 The complete annual reports together with Audited statement of accounts of the company for last five years of its own (separate) immediately preceding the date of submission of bid.
Note I. In the event the bidder is not able to furnish the information of its own (i.e separate), being a subsidiary company and its accounts are being consolidated with its group/holding/parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group/Holding/Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/documents are based on the audited accounts as the case may be.
II. Similarly, if the bidder happens to be a Group/Holding/Parent Company, the bidder should submit the above documents/information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information/documents are based on the audited accounts, as the case may be.
5.2 The Bidder should accordingly also provide the following information/documents (In case of JV bidders, information should be provided separately for all the Partners of JV in the given format):
Audited balance sheet and income statements for the last five years as per the following:
For Name of Other Partner-1 of JV For Name of Other Partner-2 of JV
A Years preceding to the bid opening Audited Balance Sheet and Income Statements enclosed Audited Balance Sheet and Income Statements enclosed
1st Year Yes Yes
2nd Year Yes Yes
3rd Year Yes Yes
4th Year Yes Yes
5th Year Yes Yes
Date : Printed Name :
Place : Designation :
Package Name Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
Package Code SS01
Specification No. TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Installation Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Goods) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Sole Bidder 1
JV (Joint Venture) 2 or More
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] 0
Name of Lead Partner …….. …….. …….. …….. …….. ……..
Address of Lead Partner …….. …….. …….. …….. …….. ……..
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 1 Direct Total #REF! 0 `
BO Total #REF! 0
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Activity Description Material Code HSN Code Whether HSN in column ‘ 2 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST as confirmed by Bidder
765 kV Narela GIS
1 LT Transformer 1000006173 85042200 18% 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0.00
2 Steel structure 1000015954 73082011 18% Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 331 Included 0.00 0 0.00
3 Steel structure 1000015953 73082011 18% Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 133 Included 0.00 0 0.00
4 Steel structure 1000011713 73082011 18% Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 17 Included 0.00 0 0.00
5 Steel structure 1000012373 73082011 18% Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 21 Included 0.00 0 0.00
6 800 kV GIS Equipment 1000006148 85359030 18% 800kV, 3150 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 3 Included 0.00 0 0.00
7 800 kV GIS Equipment 1000006136 85359030 18% 800kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare transformer as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0.00
8 800 kV GIS Equipment 1000006107 85359030 18% 800kV, 3150A ,50kA, SF6 GIS Line feederbay module(without PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
9 800 kV GIS Equipment 1000006150 85359030 18% 800kV, 3150A ,50kA, GIS Line feeder baymodule (with PIR) as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
10 800 kV GIS Equipment 1000006152 85359030 18% 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
11 800 kV GIS Equipment 1000006108 85359030 18% 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
12 800 kV GIS Equipment 1000006151 85359030 18% 800kV, 3150A, 50kA, SF6 GIS SwitchableLine Reactor feeder bay module as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
13 800 kV GIS Equipment 1000006146 85359030 18% 800 kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare line Reactor asper Section-Project, Technicalspecification SET 1 Included 0.00 0 0.00
14 800 kV GIS Equipment 1000009714 85364900 18% Controlled Switching Device for 765 kV, 3-ph Circuit Breaker EA 15 Included 0.00 0 0.00
15 800 kV GIS Equipment 1000006137 85359030 18% 800kV, 3150A, 50kA, SF6 GIS Bus Reactorfeeder bay module as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
16 800 kV GIS Equipment 1000006113 85359030 18% 800kV, 4000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included 0.00 0 0.00
17 800 kV Outdoor Equipment 1000019013 85389000 18% SF6 to air bushing (765kV of each type & rating) as applicable SET 35 Included 0.00 0 0.00
18 800 kV Outdoor Equipment 1000006101 85389000 18% 800kV, 3000/3150 A, 50kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall along with associated support structure. M 3400 Included 0.00 0 0.00
19 800 kV Outdoor Equipment 1000020421 85354010 18% 624kV Surge Arrester (1-Phase) EA 40 Included 0.00 0 0.00
20 800 kV Outdoor Equipment 1000005840 85359090 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 0.00
21 800 kV Outdoor Equipment 1000005791 85462040 18% 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 39 Included 0.00 0 0.00
22 145 KV Equipment 1000000945 85352911 18% 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included 0.00 0 0.00
23 145 KV Equipment 1000000956 85462040 18% 145kV, 1 phase Bus Post Insulators EA 4 Included 0.00 0 0.00
24 36 kV Equipment 1000002011 85049010 18% Current transformer (33kV) for transformer Netural along with supportstructure & terminal connector EA 3 Included 0.00 0 0.00
25 36 kV Equipment 1000002087 85353090 18% 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0.00 0 0.00
26 36 kV Equipment 1000020418 85354010 18% 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0.00
27 36 kV Equipment 1000001999 85049010 18% Current transformer (33kV) for Reactor Neutral along with supportstructure & terminal connector EA 4 Included 0.00 0 0.00
28 36 kV Equipment 1000028100 85049010 18% 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included 0.00 0 0.00
29 36 kV Equipment 1000002032 85462040 18% 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included 0.00 0 0.00
30 72.5 kV Equipment 1000005030 85462040 18% 72.5kV ,1 phase Bus Post Insulators EA 9 Included 0.00 0 0.00
31 72.5 kV Equipment 1000005048 85359090 18% 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0.00
32 72.5 kV Equipment 1000005061 85359090 18% 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
33 72.5 kV Equipment 1000005036 85352113 18% 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0.00
34 72.5 kV Equipment 1000005070 85353090 18% 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0.00 0 0.00
35 Testing & Maintenance equipment 1000024692 85389000 18% EOT Crane for GIS Building for 800kV GIS station SET 1 Included 0.00 0 0.00
36 Testing & Maintenance equipment 1000025441 85389000 18% SF6 Gas Filling and Evacuation Plant for 800kV GIS station SET 1 Included 0.00 0 0.00
37 Testing & Maintenance equipment 1000025329 90318000 18% Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 Included 0.00 0 0.00
38 Testing & Maintenance equipment 1000032132 85389000 18% SF6 GAS ANALYZER EA 1 Included 0.00 0 0.00
39 Testing & Maintenance equipment 1000025436 90271000 18% SF6 Gas Leakage Detector EA 1 Included 0.00 0 0.00
40 765 kV Control & Relay Panel 1000005074 85371000 18% 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 10 Included 0.00 0 0.00
41 765 kV Control & Relay Panel 1000005073 85371000 18% 765 kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 7 Included 0.00 0 0.00
42 765 kV Control & Relay Panel 1000005789 85371000 18% 765kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 3 Included 0.00 0 0.00
43 765 kV Control & Relay Panel 1000005533 85371000 18% 765kV Reactor Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
44 765 kV Control & Relay Panel 1000005071 85371000 18% 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.00
45 765 kV Control & Relay Panel 1000005522 85371000 18% 765kV Line Protection Panel (with Automation) EA 5 Included 0.00 0 0.00
46 765 kV Control & Relay Panel 1000030143 85371000 18% 765KV REACTOR PROTECTION PANEL, INCLUDING CONTROL & MONITORING OF145KV CB FOR NGR BY-PASSING ARRANGEMENT. (WITH AUTOMATION) SET 2 Included 0.00 0 0.00
47 Substation Automation system 1000005536 85371000 18% Complete Substation automation System for 765kV Tie bay as perTechnical Specification EA 5 Included 0.00 0 0.00
48 Substation Automation system 1000005539 85371000 18% Complete Substation automation System for 765kV Switchable LineReactor Bay as per Technical Specification EA 2 Included 0.00 0 0.00
49 Substation Automation system 1000005534 85371000 18% Complete Substation automation system for 765kV Main bay as perTechnical Specification EA 10 Included 0.00 0 0.00
50 Substation Automation system 1000018700 85371000 18% Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included 0.00 0 0.00
51 LT Switchgear 1000004313 85371000 18% 415V Main Switchboard SET 1 Included 0.00 0 0.00
52 LT Switchgear 1000004303 85371000 18% 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included 0.00 0 0.00
53 LT Switchgear 1000004312 85371000 18% 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included 0.00 0 0.00
54 LT Switchgear 1000001144 85371000 18% 220V DCDB SET 2 Included 0.00 0 0.00
55 LT Switchgear 1000004307 85371000 18% 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0.00
56 LT Switchgear 1000004754 85371000 18% 48V DCDB SET 2 Included 0.00 0 0.00
57 Batteries and Charger 1000001151 85072000 28% 220V, 1500 Ah Battery SET 2 Included 0.00 0 0.00
58 Batteries and Charger 1000004762 85072000 28% 48V, 1500 Ah Battery SET 2 Included 0.00 0 0.00
59 Batteries and Charger 1000001153 85044030 18% 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.00
60 Batteries and Charger 1000004764 85044030 18% 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.00
61 Erection Hardware 1000011363 72169990 18% Erection Hardware for 765kV I type layout-Transformer bay as pertechnical specification SET 3 Included 0.00 0 0.00
62 Erection Hardware 1000011349 72169990 18% Erection Hardware for 765kV I type layout-Bus Reactor bay as pertechnical specification SET 2 Included 0.00 0 0.00
63 Erection Hardware 1000011356 72169990 18% Erection Hardware for 765kV I type layout-Line Reactors including NGRbypass arrangement as per technical specification SET 2 Included 0.00 0 0.00
64 Erection Hardware 1000011355 85389000 18% Erection Hardware for 765kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 4 Included 0.00 0 0.00
65 Erection Hardware 1000015928 85049010 18% Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 765KV and neutral bushings terminal connectors etc for Neutral formationfor two (2) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to two (2) neutral grounding Reactorsand making connection arrangement to connect spare unit in place of anyunit of all the two banks without pysical shifting LOT 2 Included 0.00 0 0.00
66 Erection Hardware 1000015788 85049010 18% Bus post insulators, spacers, equipmentsupport structures, conductors, Altube, clamp, connectors (including765kV, 400kV, tertiary and neuturalbushing terminal connectors etc) forarrangement of netural formation forTransformer(s), DELTA formation for onebank (each bank comprises of 3 singlephase units of Autotransformers) andmaking connection arrangement toconnect spare unit in place of any unitof the bank without physical shifting LOT 3 Included 0.00 0 0.00
67 Erection Hardware 1000011348 72169990 18% Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included 0.00 0 0.00
68 Erection Hardware 1000032412 85049010 18% ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included 0.00 0 0.00
69 DG SET 1000004797 85021310 18% 500 kVA Diesel Generator along with control Panel SET 1 Included 0.00 0 0.00
70 Air conditioning &ventilation system 1000022410 84159000 28% Ventillation system for 765KV GIS Hall SET 1 Included 0.00 0 0.00
71 Air conditioning &ventilation system 1000013502 84158210 28% High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 0.00
72 Fireprotection System 1000012032 84819090 18% Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included 0.00 0 0.00
73 Fireprotection System 1000012038 84819090 18% Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 765/400/220kV (New) Substation SET 1 Included 0.00 0 0.00
74 Fireprotection System 1000012015 85311020 18% Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included 0.00 0 0.00
75 Fireprotection System 1000012072 84248990 18% HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 10 Included 0.00 0 0.00
76 Fireprotection System 1000012041 84248990 18% HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 110 MVAR, 765/√3 kVsingle phase Shunt Reactor SET 13 Included 0.00 0 0.00
77 Fireprotection System 1000012027 84241000 18% 9litre water type Portable Fire extinguisher EA 4 Included 0.00 0 0.00
78 Fireprotection System 1000012022 84241000 18% 4.5 kg CO2 type Portable Fire extinguisher EA 12 Included 0.00 0 0.00
79 Fireprotection System 1000049665 84241000 18% 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 2 Included 0.00 0 0.00
80 Fireprotection System 1000012011 85311020 18% Fire Detection and Alarm System for 765kV GIS Hall SET 1 Included 0.00 0 0.00
81 Fireprotection System 1000049458 84818090 18% FIRE PROTECTION SYSTEM FOR LOCAL RELAY ROOM FOR 800KV GIS SET 1 Included 0.00 0 0.00
82 Fireprotection System 1000012024 84241000 18% Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 10 Included 0.00 0 0.00
83 Illumination-Indoor 1000049467 94059900 18% INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 Included 0.00 0 0.00
84 Illumination-Indoor 1000049469 94059900 18% INDOOR LIGHTNING FOR DG SET & FIRE FIGHTING PUMP HOUSE SET 1 Included 0.00 0 0.00
85 Illumination-Indoor 1000009690 94059900 18% Control room cum administrative building (765kV) illuminationincluding Conduit LOT 1 Included 0.00 0 0.00
86 Illumination-Indoor 1000030151 94059900 18% Security Room Illumination including conduit LS 1 Included 0.00 0 0.00
87 Illumination-Outdoor 1000038387 94051090 18% LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 70 Included 0.00 0 0.00
88 Illumination-Outdoor 1000038389 94051090 18% LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 20 Included 0.00 0 0.00
89 Illumination-Outdoor 1000004952 94059900 18% 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 Included 0.00 0 0.00
90 Illumination-Outdoor 1000001050 94059900 18% 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 2 Included 0.00 0 0.00
91 Illumination-Outdoor 1000025538 76169990 18% Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 0.00
92 Illumination-Outdoor 1000024515 76169990 18% Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included 0.00 0 0.00
93 Illumination-Outdoor 1000001894 94059900 18% Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included 0.00 0 0.00
94 Illumination-Outdoor 1000020262 85371000 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 10 Included 0.00 0 0.00
95 Illumination-Outdoor 1000038325 94059900 18% LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 70 Included 0.00 0 0.00
96 Illumination-Outdoor 1000038397 94059900 18% TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 20 Included 0.00 0 0.00
97 Illumination-Outdoor 1000014547 85371000 18% Lighting Panel type ACP-2 as per technical specification EA 3 Included 0.00 0 0.00
98 Power & Control Cables 1000032045 85446090 18% 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2 Included 0.00 0 0.00
99 Power & Control Cables 1000000444 85446090 18% 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.00
100 Power & Control Cables 1000049490 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV LINE REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
101 Power & Control Cables 1000049491 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 5 Included 0.00 0 0.00
102 Power & Control Cables 1000049492 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included 0.00 0 0.00
103 Power & Control Cables 1000049493 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 765 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC. SET 5 Included 0.00 0 0.00
104 Power & Control Cables 1000049489 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV BUS REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
105 Power & Control Cables 1000049482 85446090 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
106 PLCC Equipment 1000005823 85176210 18% 765kV,3150A,1.0mH , 50kA Line Trap EA 8 Included 0.00 0 0.00
107 PLCC Equipment 1000005790 85462040 18% 765 kV ,1 phase Bus Post Insulators for Line Traps EA 24 Included 0.00 0 0.00
108 PLCC Equipment 1000010014 85176210 18% Coupling device for PLCC SET 4 Included 0.00 0 0.00
109 PLCC Equipment 1000028380 85176210 18% CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 3 Included 0.00 0 0.00
110 PLCC Equipment 1000017887 85176210 18% Analog Protection Coupler for PLCC EA 3 Included 0.00 0 0.00
111 PLCC Equipment 1000010638 85176210 18% Digital Protection Coupler EA 3 Included 0.00 0 0.00
112 PLCC Equipment 1000036908 85446020 18% HF CABLE 75 OHMS FOR PLCC KM 2 Included 0.00 0 0.00
113 PLCC Equipment 1000002134 85176210 18% 4wire telephone equipment EA 4 Included 0.00 0 0.00
114 PLCC Equipment 1000025769 85176210 18% Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included 0.00 0 0.00
115 PLCC Equipment 1000011082 85176210 18% EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0.00
116 Main Earthmat 1000032055 72159090 18% 40 MM MS ROD FOR MAIN EARTHMAT KM 8 Included 0.00 0 0.00
117 Structures- Equipment 1000050815 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CLASS SA (1PH) EA 40 Included 0.00 0 0.00
118 Structures- Equipment 1000050813 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 12 Included 0.00 0 0.00
119 Structures- Equipment 1000050811 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 39 Included 0.00 0 0.00
120 Structures- Equipment 1000050816 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 8 Included 0.00 0 0.00
121 Telecommunication Equipment 1000031367 85176260 18% SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 3 Included 0.00 0 0.00
122 Telecommunication Equipment 1000018706 85176990 18% S16.1 SFP EA 8 Included 0.00 0 0.00
123 Telecommunication Equipment 1000019315 85176290 18% Optical Line Interface card (to support minimum 150 kms) EA 4 Included 0.00 0 0.00
124 Telecommunication Equipment 1000019317 85176290 18% Optical Line Interface card To support minimum 175 km EA 4 Included 0.00 0 0.00
125 Telecommunication Equipment 1000031405 85176290 18% OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included 0.00 0 0.00
126 Telecommunication Equipment 1000031374 85176290 18% TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 6 Included 0.00 0 0.00
127 Telecommunication Equipment 1000034950 85176990 18% ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 6 Included 0.00 0 0.00
128 Telecommunication Equipment 1000031381 85176290 18% TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 3 Included 0.00 0 0.00
129 Telecommunication Equipment 1000026228 85176290 18% Equipment Cabinets For SDH EA 3 Included 0.00 0 0.00
130 Telecommunication Equipment 1000028495 84715000 18% NMS- CRAFT TERMINAL-HARDWARE EA 1 Included 0.00 0 0.00
131 Telecommunication Equipment 1000028265 85238020 18% Software for Craft Terminal EA 1 Included 0.00 0 0.00
132 Telecommunication Equipment 1000034998 85171890 18% VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 8 Included 0.00 0 0.00
133 Telecommunication Equipment 1000030942 85447090 18% 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 3 Included 0.00 0 0.00
134 Telecommunication Equipment 1000023471 85372000 18% OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 3 Included 0.00 0 0.00
135 Telecommunication Equipment 1000017518 85364900 18% PMU with GPS Clock (clock can be either internal or external) EA 4 Included 0.00 0 0.00
136 Telecommunication Equipment 1000022512 90311000 18% WAMS Hardware - Time System (GPS receiver) EA 4 Included 0.00 0 0.00
137 Telecommunication Equipment 1000022510 85176290 18% WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 5 Included 0.00 0 0.00
138 Telecommunication Equipment 1000022487 85447090 18% WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0.00
139 Structures - Misc 1000049659 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included 0.00 0 0.00
140 Structures - Misc 1000049660 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included 0.00 0 0.00
141 Structures - Misc 1000049661 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included 0.00 0 0.00
142 Structures - Misc 1000049658 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 9 Included 0.00 0 0.00
143 Visual Monitoring System 1000025861 85287390 28% Visual Monitoring System for Watch & Ward SET 1 Included 0.00 0 0.00
144 Mandatory Spares- GIS (General) 1000049510 85359030 18% COMPLETE GIS MODULES, ALONG WITHENCLOSURE, ALL ACTIVE PARTS SUCH ASCONDUCTOR JOINTS, SHIELDS, END COVERSETC. FOR EACH TYPE OF BUS BAR SECTIONS(INCLUDING BUS BAR INTERCONNECTIONMODULES), BUS DUCTS SECTIONS(INCLUDING COMPENSATORS/ EXPANSIONJOINTS/BELLOWS), BENDS, SF6/AIRBUSHING, OIL/SF6 BUSHING ,CABLETERMINATION KIT-765kV GIS (ASAPPLICABLE) SET 1 Included 0.00 0 0.00
145 Mandatory Spares- GIS (General) 1000049815 85359030 18% SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE-765KV GIS SET 1 Included 0.00 0 0.00
146 Mandatory Spares- GIS (General) 1000049818 85359030 18% SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-765KV GIS SET 5 Included 0.00 0 0.00
147 Mandatory Spares- GIS (General) 1000049754 85359030 18% COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-765KV GIS SET 2 Included 0.00 0 0.00
148 Mandatory Spares- GIS (General) 1000049763 85359030 18% RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-765KV GIS SET 5 Included 0.00 0 0.00
149 Mandatory Spares- GIS (General) 1000049787 85359030 18% MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (10 % OFTOTAL WEIGHT)-765KV GIS SET 1 Included 0.00 0 0.00
150 Mandatory Spares- GIS (General) 1000049751 85359030 18% CONTROL VALVES FOR SF6 GAS OF EACH TYPE-765KV GIS SET 3 Included 0.00 0 0.00
151 Mandatory Spares- GIS (General) 1000049812 85359030 18% SF6 GAS (20 % OF TOTAL GAS QUANTITY)-765KV GIS LOT 1 Included 0.00 0 0.00
152 Mandatory Spares- GIS (General) 1000049793 85359030 18% PIPE LENGTH (COPPER OR STEEL AS APPLICABLE) FOR SF6 CIRCUITOF EACH TYPE (IF APPLICABLE)-765KV GIS SET 2 Included 0.00 0 0.00
153 Mandatory Spares- GIS (General) 1000049784 85359030 18% LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-765KV GIS SET 2 Included 0.00 0 0.00
154 Mandatory Spares- GIS (General) 1000049506 85359030 18% UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 765KV GIS EA 5 Included 0.00 0 0.00
155 Mandatory Spares- GIS (General) 1000049827 85359030 18% SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.)-765KV GIS EA 10 Included 0.00 0 0.00
156 Mandatory Spares- GIS (General) 1000049466 85359030 18% GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)(EACH TYPE)FOR 765KV GIS EA 10 Included 0.00 0 0.00
157 Mandatory Spares- GIS (General) 1000019013 85389000 18% SF6 to air bushing (765kV of each type & rating) as applicable SET 2 Included 0.00 0 0.00
158 Mandatory Spares- GIS (CB) 1000049724 85359030 18% COMPLETE CIRCUIT BREAKER (ONE PHASE) WITHOUT PIR COMPLETE WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND MARSHALLING BOX WITHOPERATING MECHANISM TO ENABLE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF CB BY SPARE (IF APPLICABLE)-765KV GIS SET 2 Included 0.00 0 0.00
159 Mandatory Spares- GIS (CB) 1000049722 85359030 18% COMPLETE CIRCUIT BREAKER (ONE PHASE) WITH PIR COMPLETE WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND MARSHALLING BOX WITHOPERATING MECHANISM TO ENABLE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF CB BY SPARE (IF APPLICABLE)-765KV GIS SET 2 Included 0.00 0 0.00
160 Mandatory Spares- GIS (CB) 1000049463 85359030 18% FIXED, MOVING AND ARCING CONTACTS INCLUDING INSULATING NOZZLES OF EACHTYPE (FOR MAIN CHAMBER & PIR CHAMBER AS APPLICABLE) FOR 765KV GISCIRCUIT BREAKER SET 1 Included 0.00 0 0.00
161 Mandatory Spares- GIS (CB) 1000021872 85389000 18% Trip coil assembly with resistor for765kV GIS Circuit Breaker (asapplicable) SET 3 Included 0.00 0 0.00
162 Mandatory Spares- GIS (CB) 1000009207 85389000 18% Closing coil assembly with resistor for765 kV GIS Circuit Breaker (asapplicable) SET 3 Included 0.00 0 0.00
163 Mandatory Spares- GIS (CB) 1000018385 85389000 18% Relays, Power contactors, push buttons, timers & MCBs etc of each type&rating for 765 kV GIS Circuit Breaker SET 1 Included 0.00 0 0.00
164 Mandatory Spares- GIS (CB) 1000007068 85389000 18% Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker SET 3 Included 0.00 0 0.00
165 Mandatory Spares- GIS (CB) 1000049481 85359030 18% OPERATION COUNTER FOR 765KV GIS CircuitBreaker SET 2 Included 0.00 0 0.00
166 Mandatory Spares- GIS (CB) 1000049839 85359030 18% WINDOSCOPE / OBSERVING WINDOW OF EACH TYPE-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
167 Mandatory Spares- GIS (CB) 1000049769 85359030 18% HYDRAULIC OPERATING MECHANISM WITH DRIVE MOTOR OF EACH TYPE (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
168 Mandatory Spares- GIS (CB) 1000049757 85359030 18% FERRULES, JOINTS AND COUPLINGS OF EACH TYPE (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
169 Mandatory Spares- GIS (CB) 1000049760 85359030 18% HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
170 Mandatory Spares- GIS (CB) 1000049766 85359030 18% HOSE PIPE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
171 Mandatory Spares- GIS (CB) 1000049790 85359030 18% N2 ACCUMULATOR OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
172 Mandatory Spares- GIS (CB) 1000049836 85359030 18% VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
173 Mandatory Spares- GIS (CB) 1000049796 85359030 18% PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
174 Mandatory Spares- GIS (CB) 1000049809 85359030 18% PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
175 Mandatory Spares- GIS (CB) 1000049806 85359030 18% PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
176 Mandatory Spares- GIS (CB) 1000049772 85359030 18% HYDRAULIC OIL (20% OF TOTAL OIL QUANTITY) (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 1 Included 0.00 0 0.00
177 Mandatory Spares- GIS (CB) 1000049800 85359030 18% PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
178 Mandatory Spares- GIS (CB) 1000049824 85359030 18% COMPLETE SPRING OPERATING MECHANISM INCLUDING CHARGINGMECHANISM ETC. OF EACH TYPE (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
179 Mandatory Spares- GIS (CB) 1000049821 85359030 18% SPRING CHARGING MOTOR (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER EA 2 Included 0.00 0 0.00
180 Mandatory Spares- GIS (CB) 1000049441 85359030 18% COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISMETC. OF EACH TYPE FOR 765KV GISCIRCUIT BREAKER (For Hydraulic-SpringOperated Mechanism, if applicable) SET 3 Included 0.00 0 0.00
181 Mandatory Spares- GIS (CB) 1000049502 85359030 18% SPRING CHARGING MOTOR FOR 765KV GISCIRCUIT BREAKER (For Hydraulic-SpringOperated Mechanism, if applicable) EA 2 Included 0.00 0 0.00
182 Mandatory Spares- GIS (CB) 1000049495 85359030 18% PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 3 Included 0.00 0 0.00
183 Mandatory Spares- GIS (CB) 1000049803 85359030 18% PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included 0.00 0 0.00
184 Mandatory Spares- GIS (Isolator) 1000049698 85359030 18% COMPLETE SET OF 3-PHASE DIS-CONNECTOR OF EACH TYPE INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC. TOENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALL APPLICABLE TYPE OFISOLATOR BY SPARE-765KV GIS SET 1 Included 0.00 0 0.00
185 Mandatory Spares- GIS (Isolator) 1000049720 85359030 18% COMPLETE SET OF 3-PHASE MAINTENANCE EARTHING SWITCH OF EACH TYPE,INCLUDING MAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORTINSULATOR ETC TO ENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF EARTH SWITCH BY SPARE-765KV GIS SET 1 Included 0.00 0 0.00
186 Mandatory Spares- GIS (Isolator) 1000049699 85359030 18% COMPLETE SET OF 3-PHASE FAST EARTHING SWITCH OF EACH TYPE, INCLUDINGMAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.TO ENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALL APPLICABLE TYPE OFEARTH SWITCH BY SPARE (IF APPLICABLE)-765KV GIS SET 1 Included 0.00 0 0.00
187 Mandatory Spares- GIS (Isolator) 1000049746 85359030 18% COPPER CONTACT FINGERS & CORONA SHIELD FOR DIS-CONNECTOR MALE & FEMALECONTACT€“FOR ONE COMPLETE (3-PHASE) DIS-CONNECTOR OF EACH TYPE-765KVGIS SET 1 Included 0.00 0 0.00
188 Mandatory Spares- GIS (Isolator) 1000049748 85359030 18% COPPER CONTACT FINGERS & CORONA SHIELD FOR MAINTENANCE EARTHING SWITCHMALE & FEMALE CONTACTS, FOR ONE COMPLETE (3- PHASE) EARTHING SWITCH OFEACH TYPE-765KV GIS SET 1 Included 0.00 0 0.00
189 Mandatory Spares- GIS (Isolator) 1000049747 85359030 18% COPPER CONTACT FINGERS & CORONA SHIELD FOR FAST EARTHING SWITCH MALE &FEMALE CONTACTS, FOR ONE COMPLETE (3-PHASE) EARTHING SWITCH OF EACHTYPE (IF APPLICABLE)-765KV GIS SET 1 Included 0.00 0 0.00
190 Mandatory Spares- GIS (Isolator) 1000049737 85359030 18% OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR DISCONNECTOR-765KV GIS SET 2 Included 0.00 0 0.00
191 Mandatory Spares- GIS (Isolator) 1000049739 85359030 18% OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH-765KV GIS SET 2 Included 0.00 0 0.00
192 Mandatory Spares- GIS (Isolator) 1000049738 85359030 18% OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH (IF APPLICABLE)-765KVGIS SET 2 Included 0.00 0 0.00
193 Mandatory Spares- GIS (Isolator) 1000049779 85359030 18% LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-765KV GIS SET 2 Included 0.00 0 0.00
194 Mandatory Spares- GIS (Isolator) 1000049781 85359030 18% LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-765KV GIS SET 2 Included 0.00 0 0.00
195 Mandatory Spares- GIS (Isolator) 1000049780 85359030 18% LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-765KV GIS SET 2 Included 0.00 0 0.00
196 Mandatory Spares- GIS (Isolator) 1000049457 85359030 18% DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS ISOLATOR SET 2 Included 0.00 0 0.00
197 Mandatory Spares- GIS (Isolator) 1000049451 85359030 18% DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS MAINTENANCE EARTH SWITCH SET 2 Included 0.00 0 0.00
198 Mandatory Spares- GIS (Isolator) 1000049454 85359030 18% DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS FAST EARTHING SWITCH (IFAPPLICABLE) SET 2 Included 0.00 0 0.00
199 Mandatory Spares- GIS (Isolator) 1000049478 85359030 18% MOTOR FOR DRIVE MECHANISM OF EACH TYPE FOR 765KV GISISOLATOR SET 3 Included 0.00 0 0.00
200 Mandatory Spares- GIS (Isolator) 1000049475 85359030 18% MOTOR FOR DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS MAINTENANCE EARTHSWITCH SET 3 Included 0.00 0 0.00
201 Mandatory Spares- GIS (Isolator) 1000049472 85359030 18% MOTOR FOR DRIVE MECHANISM OF EACH TYPEFOR 765KV GIS FAST EARTHINGSWITCH (IF APPLICABLE) SET 3 Included 0.00 0 0.00
202 Mandatory Spares- GIS (CT) 1000049727 85359030 18% COMPLETE CT OF EACH TYPE AND RATING AS SUPPLIED WITH ENCLOSURE ANDPRIMARY CONDUCTORS TO ENABLE ONE TO ONE REPLACEMENT OF ALL APPLICABLETYPE/RATING OF CT BY SPARE-765KV GIS EA 1 Included 0.00 0 0.00
203 Mandatory Spares- GIS (LCC) 1000049499 85359030 18% LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-765kV GIS SET 5 Included 0.00 0 0.00
204 Mandatory Spares- GIS - AIS 1000005840 85359090 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 1 Included 0.00 0 0.00
205 Mandatory Spares- GIS - AIS 1000020421 85354010 18% 624kV Surge Arrester (1-Phase) EA 1 Included 0.00 0 0.00
206 Mandatory Spares- GIS - AIS 1000020440 85359090 18% Surge monitor (1-Phase) EA 5 Included 0.00 0 0.00
207 Mandatory Spares- GIS - AIS 1000005791 85462040 18% 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 1 Included 0.00 0 0.00
208 Mandatory Spares- GIS (C&R) 1000015978 85371000 18% Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV prot.,software SET 1 Included 0.00 0 0.00
209 Mandatory Spares- GIS (C&R) 1000028496 85371000 18% NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV PROT., SOFTWARE SET 1 Included 0.00 0 0.00
210 Mandatory Spares- GIS (C&R) 1000021791 85371000 18% Transformer differential protection relay EA 1 Included 0.00 0 0.00
211 Mandatory Spares- GIS (C&R) 1000018532 85371000 18% Restricted earthfault relay type with non-linear resistor andassociated software in case of numerical relay EA 1 Included 0.00 0 0.00
212 Mandatory Spares- GIS (C&R) 1000030545 85371000 18% Direction O/C & E/F relay (if stand alone) EA 1 Included 0.00 0 0.00
213 Mandatory Spares- GIS (C&R) 1000018309 85371000 18% Reactor differential protection relay SET 1 Included 0.00 0 0.00
214 Mandatory Spares- GIS (C&R) 1000018304 85371000 18% Numerical Reactor Backup Impedance relay EA 1 Included 0.00 0 0.00
215 Mandatory Spares- GIS (SAS 1000007627 85389000 18% Bay control unit (IED) of each type EA 1 Included 0.00 0 0.00
216 Mandatory Spares- GIS (SAS 1000011151 85389000 18% Ethernet switch of each type SET 1 Included 0.00 0 0.00
217 Common Equipment 1000021642 85371000 18% Time synchronisation equipment EA 1 Included 0.00 0 0.00
218 Common Equipment 1000025391 82032000 18% Relay Test kit EA 1 Included 0.00 0 0.00
219 Mandatory Spares- PLCC at Narela 1000009029 85176210 28% Set of Cards/prints for carrier terminal SET 2 Included 0.00 0 0.00
220 Mandatory Spares- PLCC at Narela 1000009028 85176210 28% Set of Cards/prints for Protection coupler SET 2 Included 0.00 0 0.00
221 PLCC Equipment @ Bhiwani SS 1000028380 85176210 18% CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 1 Included 0.00 0 0.00
222 PLCC Equipment @ Bhiwani SS 1000017887 85176210 18% Analog Protection Coupler for PLCC EA 1 Included 0.00 0 0.00
223 PLCC Equipment @ Bhiwani SS 1000010638 85176210 18% Digital Protection Coupler EA 1 Included 0.00 0 0.00
224 Mandatory Spares- PLCC at Bhiwani 1000009029 85176210 18% Set of Cards/prints for carrier terminal SET 1 Included 0.00 0 0.00
225 Mandatory Spares- PLCC at Bhiwani 1000009028 85176210 18% Set of Cards/prints for Protection coupler SET 1 Included 0.00 0 0.00
226 Structures - For NGR by-passing 1000050973 73045930 28% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-145KV BPI (1PH) EA 4 Included 0.00 0 0.00
Ext.765 bays at Khetri SS 0 0.00
227 Steel structure 1000015954 73082011 18% Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 284 Included 0.00 0 0.00
228 Steel structure 1000015953 73082011 18% Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 98 Included 0.00 0 0.00
229 Steel structure 1000011713 73082011 18% Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 14 Included 0.00 0 0.00
230 Steel structure 1000012373 73082011 18% Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 18 Included 0.00 0 0.00
231 Steel structure 1000050812 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CT (1PH) EA 12 Included 0.00 0 0.00
232 Steel structure 1000050813 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 6 Included 0.00 0 0.00
233 Steel structure 1000050817 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV ISO (3PH) EA 10 Included 0.00 0 0.00
234 Steel structure 1000050815 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CLASS SA (1PH) EA 6 Included 0.00 0 0.00
235 Steel structure 1000050811 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 21 Included 0.00 0 0.00
236 Steel structure 1000050816 73045930 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 4 Included 0.00 0 0.00
237 765 kV Equipment 1000005827 85352919 18% 765kV, 3150A, 50kA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 4 Included 0.00 0 0.00
238 765 kV Equipment 1000005848 85359090 18% 765 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included 0.00 0 0.00
239 765 kV Equipment 1000005840 85359090 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0.00 0 0.00
240 765 kV Equipment 1000005853 85353090 18% 765kV, 3150A, 50Ka, Vertical Knee/DoubleBreak Isolator (3-Phase) with one E/S EA 8 Included 0.00 0 0.00
241 765 kV Equipment 1000005854 85353090 28% 765kV, 3150A, 50Ka, Vertical Knee/DoubleBreak Isolator (3-Phase) with two E/S EA 2 Included 0.00 0 0.00
242 765 kV Equipment 1000020421 85354010 28% 624kV Surge Arrester (1-Phase) EA 6 Included 0.00 0 0.00
243 765 kV Equipment 1000005791 85462040 18% 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 21 Included 0.00 0 0.00
244 Erection Harware 1000011358 72169990 18% Erection Hardware for 765kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 0.00
245 Erection Harware 1000011350 72169990 18% Erection Hardware for 765kV I type layout-Bus Work (For one diameters)as per technical specification SET 2 Included 0.00 0 0.00
246 765 kV Control & relay 1000005074 85371000 28% 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
247 765 kV Control & relay 1000005522 85371000 28% 765kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
248 765 kV Control & relay 1000005072 85371000 18% Augmentation of existing 765kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 Included 0.00 0 0.00
249 Substation automation system 1000005535 85371000 18% Augmentation of Substation automation system for 765kV Main bay as perTechnical Specification EA 2 Included 0.00 0 0.00
250 Substation automation system 1000005537 85371000 18% Augmentation of Substation automation System for 765kV Tie bay as perTechnical Specification EA 2 Included 0.00 0 0.00
251 PLCC Equipment 1000005823 85176210 18% 765kV,3150A,1.0mH , 50kA Line Trap EA 4 Included 0.00 0 0.00
252 PLCC Equipment 1000005790 85462040 18% 765 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
253 PLCC Equipment 1000010014 85176210 18% Coupling device for PLCC SET 2 Included 0.00 0 0.00
254 PLCC Equipment 1000028380 85176210 18% CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 2 Included 0.00 0 0.00
255 PLCC Equipment 1000017887 85176210 18% Analog Protection Coupler for PLCC EA 2 Included 0.00 0 0.00
256 PLCC Equipment 1000010638 85176210 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
257 PLCC Equipment 1000036908 85446020 18% HF CABLE 75 OHMS FOR PLCC KM 1 Included 0.00 0 0.00
258 PLCC Equipment 1000002134 85176210 18% 4wire telephone equipment EA 2 Included 0.00 0 0.00
259 PLCC Equipment 1000025769 85176210 18% Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included 0.00 0 0.00
260 Air Conditioning System 1000006285 84151090 28% Air conditioning system for Switchyard Panel Room of 9m length SET 2 Included 0.00 0 0.00
261 Fire protection System 1000012019 85311020 18% Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 2 Included 0.00 0 0.00
262 Fire protection System 1000012022 84241000 18% 4.5 kg CO2 type Portable Fire extinguisher EA 2 Included 0.00 0 0.00
263 Illumination(Indoor) 1000013796 94059900 18% Illumination System for switchyard panel room of 9 m length LS 2 Included 0.00 0 0.00
264 Illumination(Outdoor) 1000014547 85371000 18% Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0.00
265 Illumination(Outdoor) 1000020262 85371000 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 3 Included 0.00 0 0.00
266 Illumination(Outdoor) 1000038387 94051090 28% LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 Included 0.00 0 0.00
267 Illumination(Outdoor) 1000038325 94059900 28% LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 20 Included 0.00 0 0.00
268 Power and Control Cables 1000049493 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 765 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC. SET 2 Included 0.00 0 0.00
269 Power and Control Cables 1000049491 85446090 18% 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included 0.00 0 0.00
270 Power and Control Cables 1000049482 85446090 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
271 Main Earthmat 1000032055 72159090 18% 40 MM MS ROD FOR MAIN EARTHMAT KM 4 Included 0.00 0 0.00
272 telecommunication Equipment 1000031367 85176260 18% SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0.00
273 telecommunication Equipment 1000018706 85176990 18% S16.1 SFP EA 4 Included 0.00 0 0.00
274 telecommunication Equipment 1000031405 85176290 18% OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included 0.00 0 0.00
275 telecommunication Equipment 1000031374 85176290 18% TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0.00
276 telecommunication Equipment 1000034950 85176990 18% ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0.00
277 telecommunication Equipment 1000031381 85176290 18% TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0.00
278 telecommunication Equipment 1000026228 85176290 18% Equipment Cabinets For SDH EA 1 Included 0.00 0 0.00
279 telecommunication Equipment 1000034998 85171890 18% VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 Included 0.00 0 0.00
280 telecommunication Equipment 1000030942 85447090 18% 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included 0.00 0 0.00
281 telecommunication Equipment 1000023471 85372000 18% OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included 0.00 0 0.00
282 telecommunication Equipment 1000017518 85364900 18% PMU with GPS Clock (clock can be either internal or external) EA 2 Included 0.00 0 0.00
283 telecommunication Equipment 1000022512 90311000 18% WAMS Hardware - Time System (GPS receiver) EA 2 Included 0.00 0 0.00
284 telecommunication Equipment 1000022510 85176290 18% WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included 0.00 0 0.00
285 telecommunication Equipment 1000022487 85447090 18% WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included 0.00 0 0.00
286 Mandatory Spare - 765 kV CB 1000005824 85352919 18% Complete Pole of 765kV, 3150A, 50kA SF6Circuit Breaker including closingresistor, grading capacitor, polecolumn, interrupter with drivingmechanism and Marshelling Box butwithout support structure EA 1 Included 0.00 0 0.00
287 Mandatory Spare - 765 kV CB 1000013165 85389000 18% Grading capacitors for 765kV SF6 Circuit Breaker EA 1 Included 0.00 0 0.00
288 Mandatory Spare - 765 kV CB 1000013065 85389000 18% Rubber gasket, O rings and seals for SF6 gas (complete replacement forone 765kV breaker) SET 1 Included 0.00 0 0.00
289 Mandatory Spare - 765 kV CB 1000021866 85389000 28% Trip coil with resistor for 765kV SF6 Circuit Breaker EA 3 Included 0.00 0 0.00
290 Mandatory Spare - 765 kV CB 1000009202 85389000 28% Closing coil with resistor for 765kV SF6 Circuit Breaker EA 3 Included 0.00 0 0.00
291 Mandatory Spare - 765 kV CB 1000021457 85389000 18% Terminal pad for 765kV, 3150A, SF6Circuit Breaker EA 2 Included 0.00 0 0.00
292 Mandatory Spare - 765 kV CB 1000015552 85389000 18% Molecular filter for 765kV SF6 Circuit Breaker EA 2 Included 0.00 0 0.00
293 Mandatory Spare - 765 kV CB 1000009869 85389000 18% Corona rings (1 No of each type) for 765 kV Circuit Breaker SET 1 Included 0.00 0 0.00
294 Mandatory Spare - 765 kV CB 1000018382 85389000 18% Relays, Power contactors, SFU, limit switches, push buttons, timers &MCB etc. (1 No of each type) for 765kV Circuit Breaker SET 1 Included 0.00 0 0.00
295 Mandatory Spare - 765 kV CB 1000019006 85389000 18% SF6 Pressure gauge cum switch OR Density monitors and pressure switchas applicable (1 no. of each type) SET 1 Included 0.00 0 0.00
296 Mandatory Spare - 765 kV CB 1000006923 85389000 18% Aux. Switch/contact assembly for 765kV SF6 Circuit Breaker SET 1 Included 0.00 0 0.00
297 Mandatory Spare - 765 kV CT 1000005848 85359090 18% 765 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 1 Included 0.00 0 0.00
298 Mandatory Spare - 765 kV CVT 1000005840 85359090 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 1 Included 0.00 0 0.00
299 Mandatory Spare - 765 kV Isolator 1000009801 85389000 18% Copper contact fingers for female & male contacts of 765kV Isolator SET 2 Included 0.00 0 0.00
300 Mandatory Spare - 765 kV Isolator 1000009569 85389000 18% Open / Close contactor assembly, timers, key interlock push buttonswitch & auxiliary switches for 765kV Isolator SET 1 Included 0.00 0 0.00
301 Mandatory Spare - 765 kV Isolator 1000014570 85389000 18% Limit Switch (Complete for 1 MOM box of Isolator) SET 2 Included 0.00 0 0.00
302 Mandatory Spare - 765 kV Isolator 1000021491 85389000 18% Terminal pads & connectors (of each type) for 765kV Isolator EA 3 Included 0.00 0 0.00
303 Mandatory Spare - 765 kV Isolator 1000009928 85389000 18% Corona shield rings for 765kV Isolator SET 3 Included 0.00 0 0.00
304 Mandatory Spare - 765 kV BPI 1000020421 85354010 18% 624kV Surge Arrester (1-Phase) EA 1 Included 0.00 0 0.00
305 Mandatory Spare - 765 kV BPI 1000020441 85359090 18% Surge monitor for 624 kV Surge Arrester (1-Phase) EA 2 Included 0.00 0 0.00
306 Mandatory Spare - Protection 1000015978 85371000 18% Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV prot.,software SET 1 Included 0.00 0 0.00
307 Mandatory Spare - Protection 1000028496 85371000 18% NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV PROT., SOFTWARE SET 1 Included 0.00 0 0.00
308 Mandatory Spare - SAS 1000007627 85389000 18% Bay control unit (IED) of each type EA 1 Included 0.00 0 0.00
309 Mandatory Spare - SAS 1000011151 85389000 18% Ethernet switch of each type SET 1 Included 0.00 0 0.00
310 Mandatory Spare - PLCC 1000009029 85176210 18% Set of Cards/prints for carrier terminal SET 2 Included 0.00 0 0.00
311 Mandatory Spare - PLCC 1000009028 85176210 18% Set of Cards/prints for Protection coupler SET 2 Included 0.00 0 0.00
Total Ex-works Price 0.00 0 0.00
Total GST as confirmed by Bidder 0.00
Total Ex-works Price 0.00
Total Type Test charges as per Schedule-7 Not Applicable
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 1 Direct Total 0 0 `
BO Total #REF! 0
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 0.00 #REF! #REF!
Total Ex-works Price including Type Test charges 0.00 #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 2 Dis
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-2 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 2 Direct Total #REF! 0 `
BO Total #REF! 0
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Local Transportation, Insurance and other Incidental Services Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Activity Description Material Code Item Description Unit Qty. Unit F&I price Total F&I price
765 kV Narela GIS
1 LT Transformer 1000006173 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included
2 Steel structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 331 Included
3 Steel structure 1000015953 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 133 Included
4 Steel structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 17 Included
5 Steel structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 21 Included
6 800 kV GIS Equipment 1000006148 800kV, 3150 A, 50 kA, SF6 GIS ICT feederbay module as per Section-Project,Technical specification SET 3 Included
7 800 kV GIS Equipment 1000006136 800kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare transformer as perSection-Project, Technicalspecification SET 1 Included
8 800 kV GIS Equipment 1000006107 800kV, 3150A ,50kA, SF6 GIS Line feederbay module(without PIR) as perSection-Project, Technicalspecification SET 2 Included
9 800 kV GIS Equipment 1000006150 800kV, 3150A ,50kA, GIS Line feeder baymodule (with PIR) as perSection-Project, Technicalspecification SET 3 Included
10 800 kV GIS Equipment 1000006152 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification SET 3 Included
11 800 kV GIS Equipment 1000006108 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 2 Included
12 800 kV GIS Equipment 1000006151 800kV, 3150A, 50kA, SF6 GIS SwitchableLine Reactor feeder bay module as perSection-Project, Technicalspecification SET 3 Included
13 800 kV GIS Equipment 1000006146 800 kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare line Reactor asper Section-Project, Technicalspecification SET 1 Included
14 800 kV GIS Equipment 1000009714 Controlled Switching Device for 765 kV, 3-ph Circuit Breaker EA 15 Included
15 800 kV GIS Equipment 1000006137 800kV, 3150A, 50kA, SF6 GIS Bus Reactorfeeder bay module as perSection-Project, Technicalspecification SET 2 Included
16 800 kV GIS Equipment 1000006113 800kV, 4000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included
17 800 kV Outdoor Equipment 1000019013 SF6 to air bushing (765kV of each type & rating) as applicable SET 35 Included
18 800 kV Outdoor Equipment 1000006101 800kV, 3000/3150 A, 50kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall along with associated support structure. M 3400 Included
19 800 kV Outdoor Equipment 1000020421 624kV Surge Arrester (1-Phase) EA 40 Included
20 800 kV Outdoor Equipment 1000005840 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included
21 800 kV Outdoor Equipment 1000005791 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 39 Included
22 145 KV Equipment 1000000945 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included
23 145 KV Equipment 1000000956 145kV, 1 phase Bus Post Insulators EA 4 Included
24 36 kV Equipment 1000002011 Current transformer (33kV) for transformer Netural along with supportstructure & terminal connector EA 3 Included
25 36 kV Equipment 1000002087 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included
26 36 kV Equipment 1000020418 30kV Surge Arrester (1-Phase) EA 3 Included
27 36 kV Equipment 1000001999 Current transformer (33kV) for Reactor Neutral along with supportstructure & terminal connector EA 4 Included
28 36 kV Equipment 1000028100 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 1 Included
29 36 kV Equipment 1000002032 36kV, 1 phase Bus Post Insulators as per Technical Specification EA 3 Included
30 72.5 kV Equipment 1000005030 72.5kV ,1 phase Bus Post Insulators EA 9 Included
31 72.5 kV Equipment 1000005048 72.5 kV Voltage Transformer (1- Phase) EA 3 Included
32 72.5 kV Equipment 1000005061 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included
33 72.5 kV Equipment 1000005036 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included
34 72.5 kV Equipment 1000005070 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included
35 Testing & Maintenance equipment 1000024692 EOT Crane for GIS Building for 800kV GIS station SET 1 Included
36 Testing & Maintenance equipment 1000025441 SF6 Gas Filling and Evacuation Plant for 800kV GIS station SET 1 Included
37 Testing & Maintenance equipment 1000025329 Portable Partial Discharge measurement test kitwith all necessary accessories,Industrial Grade Laptop and licensedsoftware as per Technicalspecification. EA 1 Included
38 Testing & Maintenance equipment 1000032132 SF6 GAS ANALYZER EA 1 Included
39 Testing & Maintenance equipment 1000025436 SF6 Gas Leakage Detector EA 1 Included
40 765 kV Control & Relay Panel 1000005074 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 10 Included
41 765 kV Control & Relay Panel 1000005073 765 kV Circuit Breaker Relay Panel without Auto Reclose (withAutomation) EA 7 Included
42 765 kV Control & Relay Panel 1000005789 765kV Transformer Protection Panel (For both HV & MV side)-(withAutomation) EA 3 Included
43 765 kV Control & Relay Panel 1000005533 765kV Reactor Protection Panel (with Automation) EA 2 Included
44 765 kV Control & Relay Panel 1000005071 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included
45 765 kV Control & Relay Panel 1000005522 765kV Line Protection Panel (with Automation) EA 5 Included
46 765 kV Control & Relay Panel 1000030143 765KV REACTOR PROTECTION PANEL, INCLUDING CONTROL & MONITORING OF145KV CB FOR NGR BY-PASSING ARRANGEMENT. (WITH AUTOMATION) SET 2 Included
47 Substation Automation system 1000005536 Complete Substation automation System for 765kV Tie bay as perTechnical Specification EA 5 Included
48 Substation Automation system 1000005539 Complete Substation automation System for 765kV Switchable LineReactor Bay as per Technical Specification EA 2 Included
49 Substation Automation system 1000005534 Complete Substation automation system for 765kV Main bay as perTechnical Specification EA 10 Included
50 Substation Automation system 1000018700 Complete Substation automation System for controlling and monitoringof Auxilary System including BCUs as per technical specification SET 1 Included
51 LT Switchgear 1000004313 415V Main Switchboard SET 1 Included
52 LT Switchgear 1000004303 415V AC Distribution Board (ACDB) as per Technical Specification SET 1 Included
53 LT Switchgear 1000004312 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included
54 LT Switchgear 1000001144 220V DCDB SET 2 Included
55 LT Switchgear 1000004307 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included
56 LT Switchgear 1000004754 48V DCDB SET 2 Included
57 Batteries and Charger 1000001151 220V, 1500 Ah Battery SET 2 Included
58 Batteries and Charger 1000004762 48V, 1500 Ah Battery SET 2 Included
59 Batteries and Charger 1000001153 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included
60 Batteries and Charger 1000004764 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included
61 Erection Hardware 1000011363 Erection Hardware for 765kV I type layout-Transformer bay as pertechnical specification SET 3 Included
62 Erection Hardware 1000011349 Erection Hardware for 765kV I type layout-Bus Reactor bay as pertechnical specification SET 2 Included
63 Erection Hardware 1000011356 Erection Hardware for 765kV I type layout-Line Reactors including NGRbypass arrangement as per technical specification SET 2 Included
64 Erection Hardware 1000011355 Erection Hardware for 765kV I type layout for GIS terminationarrangement-Line bay as per technical specification SET 4 Included
65 Erection Hardware 1000015928 Bus post insulators, spacers, equipment support structures includingfoundation bolts,conductor(s), Al tube, clamp, connectors including 765KV and neutral bushings terminal connectors etc for Neutral formationfor two (2) Reactor banks (each bank comprise of three single phaseunits of Reactors) and connection to two (2) neutral grounding Reactorsand making connection arrangement to connect spare unit in place of anyunit of all the two banks without pysical shifting LOT 2 Included
66 Erection Hardware 1000015788 Bus post insulators, spacers, equipmentsupport structures, conductors, Altube, clamp, connectors (including765kV, 400kV, tertiary and neuturalbushing terminal connectors etc) forarrangement of netural formation forTransformer(s), DELTA formation for onebank (each bank comprises of 3 singlephase units of Autotransformers) andmaking connection arrangement toconnect spare unit in place of any unitof the bank without physical shifting LOT 3 Included
67 Erection Hardware 1000011348 Erection Hardware for the 72.5kV equipment for Tertiary loading as pertechnical specification SET 1 Included
68 Erection Hardware 1000032412 ERECTION HARDWARE FOR AUXILIARY LT TRANSFORMER SET 1 Included
69 DG SET 1000004797 500 kVA Diesel Generator along with control Panel SET 1 Included
70 Air conditioning &ventilation system 1000022410 Ventillation system for 765KV GIS Hall SET 1 Included
71 Air conditioning &ventilation system 1000013502 High wall type split AC unit of 2 TR capacity EA 20 Included
72 Fireprotection System 1000012032 Pumping arrangement for HVW system & hydrant system, complete withall piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included
73 Fireprotection System 1000012038 Hydrant system, complete U/G piping and accessories etc. outside thePump House for Fire Protection of 765/400/220kV (New) Substation SET 1 Included
74 Fireprotection System 1000012015 Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included
75 Fireprotection System 1000012072 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 10 Included
76 Fireprotection System 1000012041 HVW spray system, Hydrant system and complete U/G & O/G piping andaccessories etc. out side the pump house for 110 MVAR, 765/√3 kVsingle phase Shunt Reactor SET 13 Included
77 Fireprotection System 1000012027 9litre water type Portable Fire extinguisher EA 4 Included
78 Fireprotection System 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 12 Included
79 Fireprotection System 1000049665 60 LITRE FOAM TYPE TROLLEY/WHEEL MOUNTED FIRE EXTINGUISHER SET 2 Included
80 Fireprotection System 1000012011 Fire Detection and Alarm System for 765kV GIS Hall SET 1 Included
81 Fireprotection System 1000049458 FIRE PROTECTION SYSTEM FOR LOCAL RELAY ROOM FOR 800KV GIS SET 1 Included
82 Fireprotection System 1000012024 Fire Extinguisher Dry Chemical Powder Type(5 Kg) for control room. EA 10 Included
83 Illumination-Indoor 1000049467 INDOOR LIGHTNING FOR GIS BUILDING (AS PER TECHNICAL SPECIFICATION) including AHU & Relay Rooms as applicable SET 1 Included
84 Illumination-Indoor 1000049469 INDOOR LIGHTNING FOR DG SET & FIRE FIGHTING PUMP HOUSE SET 1 Included
85 Illumination-Indoor 1000009690 Control room cum administrative building (765kV) illuminationincluding Conduit LOT 1 Included
86 Illumination-Indoor 1000030151 Security Room Illumination including conduit LS 1 Included
87 Illumination-Outdoor 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 70 Included
88 Illumination-Outdoor 1000038389 LED STREET LIGHT LUMINAIRE TYPE SL-L1 (= 45W)AS PER TECHNICALSPECIFICATION EA 20 Included
89 Illumination-Outdoor 1000004952 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) asper technical specifications EA 2 Included
90 Illumination-Outdoor 1000001050 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as pertechnical specifications EA 2 Included
91 Illumination-Outdoor 1000025538 Self Supported Aluminium Ladder as Per Technical Specification EA 1 Included
92 Illumination-Outdoor 1000024515 Cartwheel Mounted Aluminium Ladder as Per Technical Specification EA 1 Included
93 Illumination-Outdoor 1000001894 Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included
94 Illumination-Outdoor 1000020262 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 10 Included
95 Illumination-Outdoor 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 70 Included
96 Illumination-Outdoor 1000038397 TYPE L1 STREET LIGHTING POLE OF 6 METER AS PER TECHNICALSPECIFICATION. EA 20 Included
97 Illumination-Outdoor 1000014547 Lighting Panel type ACP-2 as per technical specification EA 3 Included
98 Power & Control Cables 1000032045 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHTJOINTS. KM 2 Included
99 Power & Control Cables 1000000444 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included
100 Power & Control Cables 1000049490 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV LINE REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
101 Power & Control Cables 1000049491 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 5 Included
102 Power & Control Cables 1000049492 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV ICT BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 3 Included
103 Power & Control Cables 1000049493 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 765 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC. SET 5 Included
104 Power & Control Cables 1000049489 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV BUS REACTOR BAYALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
105 Power & Control Cables 1000049482 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included
106 PLCC Equipment 1000005823 765kV,3150A,1.0mH , 50kA Line Trap EA 8 Included
107 PLCC Equipment 1000005790 765 kV ,1 phase Bus Post Insulators for Line Traps EA 24 Included
108 PLCC Equipment 1000010014 Coupling device for PLCC SET 4 Included
109 PLCC Equipment 1000028380 CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 3 Included
110 PLCC Equipment 1000017887 Analog Protection Coupler for PLCC EA 3 Included
111 PLCC Equipment 1000010638 Digital Protection Coupler EA 3 Included
112 PLCC Equipment 1000036908 HF CABLE 75 OHMS FOR PLCC KM 2 Included
113 PLCC Equipment 1000002134 4wire telephone equipment EA 4 Included
114 PLCC Equipment 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included
115 PLCC Equipment 1000011082 EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included
116 Main Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 8 Included
117 Structures- Equipment 1000050815 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CLASS SA (1PH) EA 40 Included
118 Structures- Equipment 1000050813 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 12 Included
119 Structures- Equipment 1000050811 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 39 Included
120 Structures- Equipment 1000050816 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 8 Included
121 Telecommunication Equipment 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 3 Included
122 Telecommunication Equipment 1000018706 S16.1 SFP EA 8 Included
123 Telecommunication Equipment 1000019315 Optical Line Interface card (to support minimum 150 kms) EA 4 Included
124 Telecommunication Equipment 1000019317 Optical Line Interface card To support minimum 175 km EA 4 Included
125 Telecommunication Equipment 1000031405 OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included
126 Telecommunication Equipment 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 6 Included
127 Telecommunication Equipment 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 6 Included
128 Telecommunication Equipment 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 3 Included
129 Telecommunication Equipment 1000026228 Equipment Cabinets For SDH EA 3 Included
130 Telecommunication Equipment 1000028495 NMS- CRAFT TERMINAL-HARDWARE EA 1 Included
131 Telecommunication Equipment 1000028265 Software for Craft Terminal EA 1 Included
132 Telecommunication Equipment 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 8 Included
133 Telecommunication Equipment 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 3 Included
134 Telecommunication Equipment 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 3 Included
135 Telecommunication Equipment 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 4 Included
136 Telecommunication Equipment 1000022512 WAMS Hardware - Time System (GPS receiver) EA 4 Included
137 Telecommunication Equipment 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 5 Included
138 Telecommunication Equipment 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
139 Structures - Misc 1000049659 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV CT(1PH) EA 3 Included
140 Structures - Misc 1000049660 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV PT (1PH) EA 3 Included
141 Structures - Misc 1000049661 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV ISOLATOR (3PH) EA 1 Included
142 Structures - Misc 1000049658 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-72.5KV BPI (1PH) EA 9 Included
143 Visual Monitoring System 1000025861 Visual Monitoring System for Watch & Ward SET 1 Included
144 Mandatory Spares- GIS (General) 1000049510 COMPLETE GIS MODULES, ALONG WITHENCLOSURE, ALL ACTIVE PARTS SUCH ASCONDUCTOR JOINTS, SHIELDS, END COVERSETC. FOR EACH TYPE OF BUS BAR SECTIONS(INCLUDING BUS BAR INTERCONNECTIONMODULES), BUS DUCTS SECTIONS(INCLUDING COMPENSATORS/ EXPANSIONJOINTS/BELLOWS), BENDS, SF6/AIRBUSHING, OIL/SF6 BUSHING ,CABLETERMINATION KIT-765kV GIS (ASAPPLICABLE) SET 1 Included
145 Mandatory Spares- GIS (General) 1000049815 SF6 GAS PRESSURE RELIEF DEVICE ASSEMBLY OF EACH TYPE-765KV GIS SET 1 Included
146 Mandatory Spares- GIS (General) 1000049818 SF6 PRESSURE GAUGE CUM SWITCH /DENSITY MONITORS AND PRESSURESWITCH AS APPLICABLE, OF EACH TYPE-765KV GIS SET 5 Included
147 Mandatory Spares- GIS (General) 1000049754 COUPLING DEVICE FOR PRESSURE GAUGE CUM SWITCH FOR CONNECTINGGAS HANDLING PLANT OF EACH TYPE-765KV GIS SET 2 Included
148 Mandatory Spares- GIS (General) 1000049763 RUBBER GASKETS, €ŒO€ RINGS AND SEALS FOR SF6 GAS FOR GISENCLOSURE OF EACH TYPE-765KV GIS SET 5 Included
149 Mandatory Spares- GIS (General) 1000049787 MOLECULAR FILTER FOR SF6 GAS WITH FILTER BAGS (10 % OFTOTAL WEIGHT)-765KV GIS SET 1 Included
150 Mandatory Spares- GIS (General) 1000049751 CONTROL VALVES FOR SF6 GAS OF EACH TYPE-765KV GIS SET 3 Included
151 Mandatory Spares- GIS (General) 1000049812 SF6 GAS (20 % OF TOTAL GAS QUANTITY)-765KV GIS LOT 1 Included
152 Mandatory Spares- GIS (General) 1000049793 PIPE LENGTH (COPPER OR STEEL AS APPLICABLE) FOR SF6 CIRCUITOF EACH TYPE (IF APPLICABLE)-765KV GIS SET 2 Included
153 Mandatory Spares- GIS (General) 1000049784 LOCKING DEVICE TO KEEP THE DIS-CONNECTORS (ISOLATORS)AND EARTHING/FAST EARTHING SWITCHES IN CLOSE OR OPEN POSITION IN CASEOF REMOVAL OF THE DRIVING MECHANISM-765KV GIS SET 2 Included
154 Mandatory Spares- GIS (General) 1000049506 UHF PD SENSORS OF EACH TYPE ALONG WITH BNC CONNECTOR FOR 765KV GIS EA 5 Included
155 Mandatory Spares- GIS (General) 1000049827 SUPPORT INSULATORS (GAS THROUGH) OF EACH TYPE (COMPLETE WITHMETAL RING ETC.)-765KV GIS EA 10 Included
156 Mandatory Spares- GIS (General) 1000049466 GAS BARRIERS OF EACH TYPE (COMPLETE WITH METAL RING ETC.)(EACH TYPE)FOR 765KV GIS EA 10 Included
157 Mandatory Spares- GIS (General) 1000019013 SF6 to air bushing (765kV of each type & rating) as applicable SET 2 Included
158 Mandatory Spares- GIS (CB) 1000049724 COMPLETE CIRCUIT BREAKER (ONE PHASE) WITHOUT PIR COMPLETE WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND MARSHALLING BOX WITHOPERATING MECHANISM TO ENABLE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF CB BY SPARE (IF APPLICABLE)-765KV GIS SET 2 Included
159 Mandatory Spares- GIS (CB) 1000049722 COMPLETE CIRCUIT BREAKER (ONE PHASE) WITH PIR COMPLETE WITHINTERRUPTER, MAIN CIRCUIT, ENCLOSURE AND MARSHALLING BOX WITHOPERATING MECHANISM TO ENABLE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF CB BY SPARE (IF APPLICABLE)-765KV GIS SET 2 Included
160 Mandatory Spares- GIS (CB) 1000049463 FIXED, MOVING AND ARCING CONTACTS INCLUDING INSULATING NOZZLES OF EACHTYPE (FOR MAIN CHAMBER & PIR CHAMBER AS APPLICABLE) FOR 765KV GISCIRCUIT BREAKER SET 1 Included
161 Mandatory Spares- GIS (CB) 1000021872 Trip coil assembly with resistor for765kV GIS Circuit Breaker (asapplicable) SET 3 Included
162 Mandatory Spares- GIS (CB) 1000009207 Closing coil assembly with resistor for765 kV GIS Circuit Breaker (asapplicable) SET 3 Included
163 Mandatory Spares- GIS (CB) 1000018385 Relays, Power contactors, push buttons, timers & MCBs etc of each type&rating for 765 kV GIS Circuit Breaker SET 1 Included
164 Mandatory Spares- GIS (CB) 1000007068 Auxiliary switch assembly of each type for 765kV GIS Circuit Breaker SET 3 Included
165 Mandatory Spares- GIS (CB) 1000049481 OPERATION COUNTER FOR 765KV GIS CircuitBreaker SET 2 Included
166 Mandatory Spares- GIS (CB) 1000049839 WINDOSCOPE / OBSERVING WINDOW OF EACH TYPE-765KV GIS CIRCUIT BREKAER SET 3 Included
167 Mandatory Spares- GIS (CB) 1000049769 HYDRAULIC OPERATING MECHANISM WITH DRIVE MOTOR OF EACH TYPE (FORHYDRAULIC OPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
168 Mandatory Spares- GIS (CB) 1000049757 FERRULES, JOINTS AND COUPLINGS OF EACH TYPE (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
169 Mandatory Spares- GIS (CB) 1000049760 HYDRAULIC FILTER OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
170 Mandatory Spares- GIS (CB) 1000049766 HOSE PIPE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
171 Mandatory Spares- GIS (CB) 1000049790 N2 ACCUMULATOR OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
172 Mandatory Spares- GIS (CB) 1000049836 VALVES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
173 Mandatory Spares- GIS (CB) 1000049796 PIPE LENGTH (COPPER & STEEL) OF EACH SIZE & TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
174 Mandatory Spares- GIS (CB) 1000049809 PRESSURE SWITCHES OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
175 Mandatory Spares- GIS (CB) 1000049806 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULICOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
176 Mandatory Spares- GIS (CB) 1000049772 HYDRAULIC OIL (20% OF TOTAL OIL QUANTITY) (FOR HYDRAULIC OPERATEDMECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 1 Included
177 Mandatory Spares- GIS (CB) 1000049800 PRESSURE RELIEF DEVICE OF EACH TYPE (FOR HYDRAULIC OPERATED MECHANISM,IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
178 Mandatory Spares- GIS (CB) 1000049824 COMPLETE SPRING OPERATING MECHANISM INCLUDING CHARGINGMECHANISM ETC. OF EACH TYPE (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
179 Mandatory Spares- GIS (CB) 1000049821 SPRING CHARGING MOTOR (FOR SPRING OPERATED MECHANISM, IFAPPLICABLE)-765KV GIS CIRCUIT BREKAER EA 2 Included
180 Mandatory Spares- GIS (CB) 1000049441 COMPLETE HYDRAULIC-SPRING OPERATINGMECHANISM INCLUDING CHARGING MECHANISMETC. OF EACH TYPE FOR 765KV GISCIRCUIT BREAKER (For Hydraulic-SpringOperated Mechanism, if applicable) SET 3 Included
181 Mandatory Spares- GIS (CB) 1000049502 SPRING CHARGING MOTOR FOR 765KV GISCIRCUIT BREAKER (For Hydraulic-SpringOperated Mechanism, if applicable) EA 2 Included
182 Mandatory Spares- GIS (CB) 1000049495 PRESSURE SWITCHES OF EACH TYPE FOR420KV GIS CIRCUIT BREAKER (ForHydraulic-Spring Operated Mechanism, ifapplicable) SET 3 Included
183 Mandatory Spares- GIS (CB) 1000049803 PRESSURE GAUGE WITH COUPLING DEVICE OF EACH TYPE (FOR HYDRAULIC-SPRINGOPERATED MECHANISM, IF APPLICABLE)-765KV GIS CIRCUIT BREKAER SET 3 Included
184 Mandatory Spares- GIS (Isolator) 1000049698 COMPLETE SET OF 3-PHASE DIS-CONNECTOR OF EACH TYPE INCLUDING MAINCIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC. TOENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALL APPLICABLE TYPE OFISOLATOR BY SPARE-765KV GIS SET 1 Included
185 Mandatory Spares- GIS (Isolator) 1000049720 COMPLETE SET OF 3-PHASE MAINTENANCE EARTHING SWITCH OF EACH TYPE,INCLUDING MAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORTINSULATOR ETC TO ENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALLAPPLICABLE TYPE OF EARTH SWITCH BY SPARE-765KV GIS SET 1 Included
186 Mandatory Spares- GIS (Isolator) 1000049699 COMPLETE SET OF 3-PHASE FAST EARTHING SWITCH OF EACH TYPE, INCLUDINGMAIN CIRCUIT, ENCLOSURE, DRIVING MECHANISM AND SUPPORT INSULATOR ETC.TO ENABLE COMPLETE ONE TO ONE REPLACEMENT OF ALL APPLICABLE TYPE OFEARTH SWITCH BY SPARE (IF APPLICABLE)-765KV GIS SET 1 Included
187 Mandatory Spares- GIS (Isolator) 1000049746 COPPER CONTACT FINGERS & CORONA SHIELD FOR DIS-CONNECTOR MALE & FEMALECONTACT€“FOR ONE COMPLETE (3-PHASE) DIS-CONNECTOR OF EACH TYPE-765KVGIS SET 1 Included
188 Mandatory Spares- GIS (Isolator) 1000049748 COPPER CONTACT FINGERS & CORONA SHIELD FOR MAINTENANCE EARTHING SWITCHMALE & FEMALE CONTACTS, FOR ONE COMPLETE (3- PHASE) EARTHING SWITCH OFEACH TYPE-765KV GIS SET 1 Included
189 Mandatory Spares- GIS (Isolator) 1000049747 COPPER CONTACT FINGERS & CORONA SHIELD FOR FAST EARTHING SWITCH MALE &FEMALE CONTACTS, FOR ONE COMPLETE (3-PHASE) EARTHING SWITCH OF EACHTYPE (IF APPLICABLE)-765KV GIS SET 1 Included
190 Mandatory Spares- GIS (Isolator) 1000049737 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR DISCONNECTOR-765KV GIS SET 2 Included
191 Mandatory Spares- GIS (Isolator) 1000049739 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR MAINTENANCE EARTHING SWITCH-765KV GIS SET 2 Included
192 Mandatory Spares- GIS (Isolator) 1000049738 OPEN/CLOSE CONTACTOR ASSEMBLY, TIMERS, KEY INTERLOCK, INTERLOCKINGCOILS, RELAYS, PUSH BUTTONS, INDICATING LAMPS, POWER CONTACTORS,RESISTORS, FUSES, MCBS & DRIVE CONTROL CARDS ETC. ONE OF EACH TYPE FORONE COMPLETE MOM BOX FOR FAST EARTHING SWITCH (IF APPLICABLE)-765KVGIS SET 2 Included
193 Mandatory Spares- GIS (Isolator) 1000049779 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORDISCONNECTOR-765KV GIS SET 2 Included
194 Mandatory Spares- GIS (Isolator) 1000049781 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FORMAINTENANCE EARTHING SWITCH-765KV GIS SET 2 Included
195 Mandatory Spares- GIS (Isolator) 1000049780 LIMIT SWITCHES AND AUX. SWITCHES FOR ONE COMPLETE MOM BOX FOR FASTEARTHING SWITCH (IF APPLICABLE)-765KV GIS SET 2 Included
196 Mandatory Spares- GIS (Isolator) 1000049457 DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS ISOLATOR SET 2 Included
197 Mandatory Spares- GIS (Isolator) 1000049451 DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS MAINTENANCE EARTH SWITCH SET 2 Included
198 Mandatory Spares- GIS (Isolator) 1000049454 DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS FAST EARTHING SWITCH (IFAPPLICABLE) SET 2 Included
199 Mandatory Spares- GIS (Isolator) 1000049478 MOTOR FOR DRIVE MECHANISM OF EACH TYPE FOR 765KV GISISOLATOR SET 3 Included
200 Mandatory Spares- GIS (Isolator) 1000049475 MOTOR FOR DRIVE MECHANISM OF EACH TYPE FOR 765KV GIS MAINTENANCE EARTHSWITCH SET 3 Included
201 Mandatory Spares- GIS (Isolator) 1000049472 MOTOR FOR DRIVE MECHANISM OF EACH TYPEFOR 765KV GIS FAST EARTHINGSWITCH (IF APPLICABLE) SET 3 Included
202 Mandatory Spares- GIS (CT) 1000049727 COMPLETE CT OF EACH TYPE AND RATING AS SUPPLIED WITH ENCLOSURE ANDPRIMARY CONDUCTORS TO ENABLE ONE TO ONE REPLACEMENT OF ALL APPLICABLETYPE/RATING OF CT BY SPARE-765KV GIS EA 1 Included
203 Mandatory Spares- GIS (LCC) 1000049499 LCC SPARES - AUX. RELAYS, CONTACTORS,PUSH BUTTONS, SWITCHES, LAMPS,ANNUNCIATION WINDOWS, MCB, FUSES,TIMERS, TERMINAL BLOCKS ETC. OF EACHTYPE & RATING-765kV GIS SET 5 Included
204 Mandatory Spares- GIS - AIS 1000005840 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 1 Included
205 Mandatory Spares- GIS - AIS 1000020421 624kV Surge Arrester (1-Phase) EA 1 Included
206 Mandatory Spares- GIS - AIS 1000020440 Surge monitor (1-Phase) EA 5 Included
207 Mandatory Spares- GIS - AIS 1000005791 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 1 Included
208 Mandatory Spares- GIS (C&R) 1000015978 Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV prot.,software SET 1 Included
209 Mandatory Spares- GIS (C&R) 1000028496 NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV PROT., SOFTWARE SET 1 Included
210 Mandatory Spares- GIS (C&R) 1000021791 Transformer differential protection relay EA 1 Included
211 Mandatory Spares- GIS (C&R) 1000018532 Restricted earthfault relay type with non-linear resistor andassociated software in case of numerical relay EA 1 Included
212 Mandatory Spares- GIS (C&R) 1000030545 Direction O/C & E/F relay (if stand alone) EA 1 Included
213 Mandatory Spares- GIS (C&R) 1000018309 Reactor differential protection relay SET 1 Included
214 Mandatory Spares- GIS (C&R) 1000018304 Numerical Reactor Backup Impedance relay EA 1 Included
215 Mandatory Spares- GIS (SAS 1000007627 Bay control unit (IED) of each type EA 1 Included
216 Mandatory Spares- GIS (SAS 1000011151 Ethernet switch of each type SET 1 Included
217 Common Equipment 1000021642 Time synchronisation equipment EA 1 Included
218 Common Equipment 1000025391 Relay Test kit EA 1 Included
219 Mandatory Spares- PLCC at Narela 1000009029 Set of Cards/prints for carrier terminal SET 2 Included
220 Mandatory Spares- PLCC at Narela 1000009028 Set of Cards/prints for Protection coupler SET 2 Included
221 PLCC Equipment @ Bhiwani SS 1000028380 CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 1 Included
222 PLCC Equipment @ Bhiwani SS 1000017887 Analog Protection Coupler for PLCC EA 1 Included
223 PLCC Equipment @ Bhiwani SS 1000010638 Digital Protection Coupler EA 1 Included
224 Mandatory Spares- PLCC at Bhiwani 1000009029 Set of Cards/prints for carrier terminal SET 1 Included
225 Mandatory Spares- PLCC at Bhiwani 1000009028 Set of Cards/prints for Protection coupler SET 1 Included
226 Structures - For NGR by-passing 1000050973 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-145KV BPI (1PH) EA 4 Included
Ext.765 bays at Khetri SS
227 Steel structure 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 284 Included
228 Steel structure 1000015953 Fabrication, galvanising and supply of Lattice Structures (HT Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 98 Included
229 Steel structure 1000011713 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 14 Included
230 Steel structure 1000012373 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 18 Included
231 Steel structure 1000050812 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CT (1PH) EA 12 Included
232 Steel structure 1000050813 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 6 Included
233 Steel structure 1000050817 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV ISO (3PH) EA 10 Included
234 Steel structure 1000050815 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CLASS SA (1PH) EA 6 Included
235 Steel structure 1000050811 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 21 Included
236 Steel structure 1000050816 EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 4 Included
237 765 kV Equipment 1000005827 765kV, 3150A, 50kA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 4 Included
238 765 kV Equipment 1000005848 765 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included
239 765 kV Equipment 1000005840 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included
240 765 kV Equipment 1000005853 765kV, 3150A, 50Ka, Vertical Knee/DoubleBreak Isolator (3-Phase) with one E/S EA 8 Included
241 765 kV Equipment 1000005854 765kV, 3150A, 50Ka, Vertical Knee/DoubleBreak Isolator (3-Phase) with two E/S EA 2 Included
242 765 kV Equipment 1000020421 624kV Surge Arrester (1-Phase) EA 6 Included
243 765 kV Equipment 1000005791 765 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 21 Included
244 Erection Harware 1000011358 Erection Hardware for 765kV I type layout-Line bay as per technicalspecification SET 2 Included
245 Erection Harware 1000011350 Erection Hardware for 765kV I type layout-Bus Work (For one diameters)as per technical specification SET 2 Included
246 765 kV Control & relay 1000005074 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 4 Included
247 765 kV Control & relay 1000005522 765kV Line Protection Panel (with Automation) EA 2 Included
248 765 kV Control & relay 1000005072 Augmentation of existing 765kV bus bar protection scheme.(No. of baysas per specification)-(with Automation) SET 1 Included
249 Substation automation system 1000005535 Augmentation of Substation automation system for 765kV Main bay as perTechnical Specification EA 2 Included
250 Substation automation system 1000005537 Augmentation of Substation automation System for 765kV Tie bay as perTechnical Specification EA 2 Included
251 PLCC Equipment 1000005823 765kV,3150A,1.0mH , 50kA Line Trap EA 4 Included
252 PLCC Equipment 1000005790 765 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
253 PLCC Equipment 1000010014 Coupling device for PLCC SET 2 Included
254 PLCC Equipment 1000028380 CARRIER EQUIPMENT ANALOG TYPE (FOR SPEECH+DATA & SPEECH+PROTECTION) EA 2 Included
255 PLCC Equipment 1000017887 Analog Protection Coupler for PLCC EA 2 Included
256 PLCC Equipment 1000010638 Digital Protection Coupler EA 2 Included
257 PLCC Equipment 1000036908 HF CABLE 75 OHMS FOR PLCC KM 1 Included
258 PLCC Equipment 1000002134 4wire telephone equipment EA 2 Included
259 PLCC Equipment 1000025769 Testing & Maintenance equipment (print test kit only) for PLCC SET 1 Included
260 Air Conditioning System 1000006285 Air conditioning system for Switchyard Panel Room of 9m length SET 2 Included
261 Fire protection System 1000012019 Fire Detection and Alarm System for Switchyard Panel Room of 9 mlength SET 2 Included
262 Fire protection System 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 2 Included
263 Illumination(Indoor) 1000013796 Illumination System for switchyard panel room of 9 m length LS 2 Included
264 Illumination(Outdoor) 1000014547 Lighting Panel type ACP-2 as per technical specification EA 1 Included
265 Illumination(Outdoor) 1000020262 Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 3 Included
266 Illumination(Outdoor) 1000038387 LED FLOOD LIGHT LUMINARIESTYPE FL-1 (150W) AS PER TECHNICALSPECIFICATION EA 20 Included
267 Illumination(Outdoor) 1000038325 LIGHTING FIXTURE LED LUMINAIRES TYPE FL2 AS PER TECH. SPECIFICATIONS EA 20 Included
268 Power and Control Cables 1000049493 1.1KV GRADE POWER & CONTROL CABLE (PVC) FOR 765 KV LINE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC. SET 2 Included
269 Power and Control Cables 1000049491 1.1KV GRADE POWER & CONTROL CABLE (PVC) 765 KV TIE BAY ALONGWITHCLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC SET 2 Included
270 Power and Control Cables 1000049482 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS,GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included
271 Main Earthmat 1000032055 40 MM MS ROD FOR MAIN EARTHMAT KM 4 Included
272 telecommunication Equipment 1000031367 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
273 telecommunication Equipment 1000018706 S16.1 SFP EA 4 Included
274 telecommunication Equipment 1000031405 OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included
275 telecommunication Equipment 1000031374 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
276 telecommunication Equipment 1000034950 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
277 telecommunication Equipment 1000031381 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
278 telecommunication Equipment 1000026228 Equipment Cabinets For SDH EA 1 Included
279 telecommunication Equipment 1000034998 VOIP TELEPHONE INSTRUMENT WITH ONE COMMON SWITCH (MIN. 8 PORT) EA 2 Included
280 telecommunication Equipment 1000030942 24F (DWSM) APPROACH FIBRE OPTIC CABLE INCLUDING ALL INSTALLATIONHARDWARE SET KM 1 Included
281 telecommunication Equipment 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 1 Included
282 telecommunication Equipment 1000017518 PMU with GPS Clock (clock can be either internal or external) EA 2 Included
283 telecommunication Equipment 1000022512 WAMS Hardware - Time System (GPS receiver) EA 2 Included
284 telecommunication Equipment 1000022510 WAMS Hardware - Substation Grade Layer-3 LAN Switches with minimum 4 x10/100 Mbps Ethernet ports and 2 x 1 Gbps Ethernet ports EA 3 Included
285 telecommunication Equipment 1000022487 WAMS Miscellaneous - Armored Fibre Optic Cable and associatedtermination (e.g. L2 Switch) for connecting PMU panels located indifferent control room of a station EA 1 Included
286 Mandatory Spare - 765 kV CB 1000005824 Complete Pole of 765kV, 3150A, 50kA SF6Circuit Breaker including closingresistor, grading capacitor, polecolumn, interrupter with drivingmechanism and Marshelling Box butwithout support structure EA 1 Included
287 Mandatory Spare - 765 kV CB 1000013165 Grading capacitors for 765kV SF6 Circuit Breaker EA 1 Included
288 Mandatory Spare - 765 kV CB 1000013065 Rubber gasket, O rings and seals for SF6 gas (complete replacement forone 765kV breaker) SET 1 Included
289 Mandatory Spare - 765 kV CB 1000021866 Trip coil with resistor for 765kV SF6 Circuit Breaker EA 3 Included
290 Mandatory Spare - 765 kV CB 1000009202 Closing coil with resistor for 765kV SF6 Circuit Breaker EA 3 Included
291 Mandatory Spare - 765 kV CB 1000021457 Terminal pad for 765kV, 3150A, SF6Circuit Breaker EA 2 Included
292 Mandatory Spare - 765 kV CB 1000015552 Molecular filter for 765kV SF6 Circuit Breaker EA 2 Included
293 Mandatory Spare - 765 kV CB 1000009869 Corona rings (1 No of each type) for 765 kV Circuit Breaker SET 1 Included
294 Mandatory Spare - 765 kV CB 1000018382 Relays, Power contactors, SFU, limit switches, push buttons, timers &MCB etc. (1 No of each type) for 765kV Circuit Breaker SET 1 Included
295 Mandatory Spare - 765 kV CB 1000019006 SF6 Pressure gauge cum switch OR Density monitors and pressure switchas applicable (1 no. of each type) SET 1 Included
296 Mandatory Spare - 765 kV CB 1000006923 Aux. Switch/contact assembly for 765kV SF6 Circuit Breaker SET 1 Included
297 Mandatory Spare - 765 kV CT 1000005848 765 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 1 Included
298 Mandatory Spare - 765 kV CVT 1000005840 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 1 Included
299 Mandatory Spare - 765 kV Isolator 1000009801 Copper contact fingers for female & male contacts of 765kV Isolator SET 2 Included
300 Mandatory Spare - 765 kV Isolator 1000009569 Open / Close contactor assembly, timers, key interlock push buttonswitch & auxiliary switches for 765kV Isolator SET 1 Included
301 Mandatory Spare - 765 kV Isolator 1000014570 Limit Switch (Complete for 1 MOM box of Isolator) SET 2 Included
302 Mandatory Spare - 765 kV Isolator 1000021491 Terminal pads & connectors (of each type) for 765kV Isolator EA 3 Included
303 Mandatory Spare - 765 kV Isolator 1000009928 Corona shield rings for 765kV Isolator SET 3 Included
304 Mandatory Spare - 765 kV BPI 1000020421 624kV Surge Arrester (1-Phase) EA 1 Included
305 Mandatory Spare - 765 kV BPI 1000020441 Surge monitor for 624 kV Surge Arrester (1-Phase) EA 2 Included
306 Mandatory Spare - Protection 1000015978 Numerical distance relay (Main-I) withinbuilt DR and fault locator,OV prot.,software SET 1 Included
307 Mandatory Spare - Protection 1000028496 NUMERICAL DISTANCE RELAY (MAIN II) WITH INBUILT DR AND FAULTLOCATOR,OV PROT., SOFTWARE SET 1 Included
308 Mandatory Spare - SAS 1000007627 Bay control unit (IED) of each type EA 1 Included
309 Mandatory Spare - SAS 1000011151 Ethernet switch of each type SET 1 Included
310 Mandatory Spare - PLCC 1000009029 Set of Cards/prints for carrier terminal SET 2 Included
311 Mandatory Spare - PLCC 1000009028 Set of Cards/prints for Protection coupler SET 2 Included
Total F&I Price 0.00
Total F&I Price 0.00
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 3
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
Installation Charges : Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
All Prices are in Indian Rupees.
SI. No. Activity Header PR Activity No. Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column '2’ is confirmed. If not indicate applicable the SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges Total GST as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
765 kV Narela GIS
1 20 20 Install- 800 kV GIS equipment 100001795 998736 18% 800kV, 3150 A, 50 kA, SF6 GIS ICT feeder bay module as per Section-Project, Technical specification SET 3 Included 0.00 0 0.00
2 20 30 Install- 800 kV GIS equipment 100001807 998736 18% 800kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare transformer as perSection-Project, Technicalspecification SET 1 Included 0.00 0 0.00
3 20 40 Install- 800 kV GIS equipment 100002084 998736 18% 800kV, 3150A ,50kA, SF6 GIS Line feederbay module(without PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
4 20 50 Install- 800 kV GIS equipment 100001798 998736 18% 800kV, 3150A ,50kA, GIS Line feeder baymodule (with PIR) as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
5 20 60 Install- 800 kV GIS equipment 100001810 998736 18% 800kV, 3150A, 50kA, SF6 GIS Bus Reactorfeeder bay module as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
6 20 70 Install- 800 kV GIS equipment 100001822 998736 18% 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(with PIR) as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
7 20 80 Install- 800 kV GIS equipment 100002090 998736 18% 800 kV, 3150A, 50kA, SF6 GIS Tie baymodule(without PIR) as perSection-Project, Technicalspecification SET 2 Included 0.00 0 0.00
8 20 90 Install- 800 kV GIS equipment 100001817 998736 18% 800kV, 4000A, 50kA, SF6 GIS Bus barmodule as per Section-Project,Technical specification SET 2 Included 0.00 0 0.00
9 20 100 Install- 800 kV GIS equipment 100001801 998736 18% 800kV, 3150A, 50kA, SF6 GIS SwitchableLine Reactor feeder bay module as perSection-Project, Technicalspecification SET 3 Included 0.00 0 0.00
10 20 110 Install- 800 kV GIS equipment 100001819 998736 18% 800 kV, 3150A, 50kA, SF6 GIS Auxiliarybus module for spare line Reactor asper Section-Project, Technicalspecification SET 1 Included 0.00 0 0.00
11 20 120 Install- 800 kV GIS equipment 100000136 998736 18% Controlled Switching Device for 765 kV, 3-ph Circuit Breaker EA 15 Included 0.00 0 0.00
12 40 10 Steel structure 100001210 995455 18% Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 331 Included 0.00 0 0.00
13 40 20 Steel structure 100001209 995455 18% Erection of Lattice Structures (HT Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts. MT 133 Included 0.00 0 0.00
14 40 30 Steel structure 100001680 995455 18% Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 17 Included 0.00 0 0.00
15 40 40 Steel structure 100001681 995455 18% Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 21 Included 0.00 0 0.00
16 50 10 Civil Works 100004518 995433 18% Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 45840 Included 0.00 0 0.00
17 50 20 Civil Works 100001325 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 1865 Included 0.00 0 0.00
18 50 30 Civil Works 100001326 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 164 Included 0.00 0 0.00
19 50 40 Civil Works 100001327 995454 18% Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 17594 Included 0.00 0 0.00
20 50 50 Civil Works 100001329 995454 18% Steel Reinforcement MT 1342 Included 0.00 0 0.00
21 50 60 Civil Works 100001330 995428 18% Stone filling (40 mm size) for transformer/Reactor foundation M3 390 Included 0.00 0 0.00
22 50 70 Civil Works 100001331 995455 18% Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 259 Included 0.00 0 0.00
23 50 80 Civil Works 100001714 995428 18% Stone spreading in switchyard excluding PCC M2 40000 Included 0.00 0 0.00
24 50 90 Civil Works 100001713 995424 18% Antiweed treatment M2 40000 Included 0.00 0 0.00
25 50 100 Civil Works 100003114 995454 18% External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 5040 Included 0.00 0 0.00
26 50 110 Civil Works 100008110 995421 18% 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 1500 Included 0.00 0 0.00
27 50 120 Civil Works 100001457 995421 18% Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having four rails for auto transformer. M2 923 Included 0.00 0 0.00
28 50 130 Civil Works 100001458 995421 18% Construction of rail cum road as per drawing including all item such as excavation,compactions, rolling watering, WBM etc. butexcluding concrete reinforcement and structural steel-Section having two rails for Reactor. M2 878 Included 0.00 0 0.00
29 50 140 Civil Works 100008611 995477 18% Swtichyard fencing: Providing and fixing fencing of GI barbed wire consisting of galvanized MS tubular posts at 3 m intervals; GIbarded wire shall run horizontally from post to post at a spacing of 300 mm (vertically) and a cross formation in each panel,complete as per technical specification and drawing. M 500 Included 0.00 0 0.00
30 50 150 Civil Works 100001392 995455 18% Switchyard Gate excluding Concrete EA 1 Included 0.00 0 0.00
31 50 160 Civil Works 130000761 995428 18% 14.4.2 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 150 mm dia M 230 Included 0.00 0 0.00
32 50 170 Civil Works 130000762 995428 18% 14.4.3 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointingwith cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. : 250 mm dia M 899 Included 0.00 0 0.00
33 50 180 Civil Works 100001735 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
34 50 190 Civil Works 100001736 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
35 50 200 Civil Works 100001737 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
36 50 210 Civil Works 100001409 995462 18% Supplying and erecting dewatering pumps-5 HP EA 2 Included 0.00 0 0.00
37 50 220 Civil Works 100001412 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 480 Included 0.00 0 0.00
38 50 230 Civil Works 100001413 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 120 Included 0.00 0 0.00
39 50 240 Civil Works 100001414 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section C-C M 120 Included 0.00 0 0.00
40 50 250 Civil Works 100001415 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section D-D M 80 Included 0.00 0 0.00
41 50 260 Civil Works 100003477 995454 18% Rain water harvesting excluding reinforcement and concrete as per drawing EA 2 Included 0.00 0 0.00
42 50 270 Civil Works 100001683 995414 18% Control Room Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 650 Included 0.00 0 0.00
43 50 280 Civil Works 100001682 995416 18% FFPH Building - Civil Works All civil works as per drawing and specifications complete, including - brickwork,finishing (externaland internal),windows etc.However, excavation, PCC,RCC and reinforcement shall be paid separately as per BPS M2 101 Included 0.00 0 0.00
44 50 29 Civil Works 100001700 995454 18% All civil works as per drawing and specification but excluding excavation, PCC, RCC, reinforcement but including finishing (internaland external) etc & all civil works complete in all respect - Water Tank for Fire Fighting Pump House EA 1 Included 0.00 0 0.00
45 50 300 Civil Works 100001742 995414 18% PEB - 765 kV GIS - Civil Works All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 5625 Included 0.00 0 0.00
46 50 310 Civil Works 100004432 995416 18% 765 kV PEB Panel Room for GIS Hall - Civil Works All civil works complete as per TS, including - brickwork, finishing (externaland internal), windows etc. However, excavation, concrete (all types) and reinforcement steel shall be measured and paid separatelyas per respective item of BPS. M2 300 Included 0.00 0 0.00
47 50 320 Civil Works 100004428 995416 18% 765 kV PEB AHU Room for GIS Hall - Civil Works All civil works complete as per TS, including - brickwork, finishing (external andinternal), windows etc. However, excavation, concrete (all types) and reinforcement steel shall be measured and paid separately asper respective item of BPS. M2 192 Included 0.00 0 0.00
48 50 330 Civil Works 100008638 995421 18% Supplying and laying CPVC pipe for external water supply system - 75 mm dia pipe M 200 Included 0.00 0 0.00
49 50 340 Civil Works 100008639 995421 18% Supplying and laying CPVC pipe for external water supply system - 50 mm dia pipe M 150 Included 0.00 0 0.00
50 50 350 Civil Works 100010100 995421 18% Supplying and laying CPVC pipe for external water supply system - 40 mm dia pipe M 150 Included 0.00 0 0.00
51 50 360 Civil Works 100010101 995421 18% Supplying and laying CPVC pipe for external water supply system - 25 mm dia pipe M 150 Included 0.00 0 0.00
52 50 370 Civil Works 100001740 995441 18% Septic tank and soakpit for CRB EA 1 Included 0.00 0 0.00
53 50 380 Civil Works 100001755 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 100mm dia pipe M 100 Included 0.00 0 0.00
54 50 390 Civil Works 100001756 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 150mm dia pipe M 100 Included 0.00 0 0.00
55 50 410 Civil Works 100001433 995435 18% Soil Investigation: As per technical specification including all laboratory and field tests, report and recommendations. LOT 1 Included 0.00 0 0.00
56 50 400 Civil Works 100001757 995424 18% Providing & Laying of SW pipes for external sewerage system as per technical specification 200mm dia pipe M 80 Included 0.00 0 0.00
57 50 420 Civil Works 100012380 995426 18% Design, Drawing and execution of Pre-fabricated structure labour Hut including toilet & baths with all materials, labours etccomplete in all respect as per the technical specification and direction of Engineer – in Charge. (Plinth area shall be measuredfor payment purpose) M2 840 Included 0.00 0 0.00
58 400 10 Install-LT transformer 100000081 998736 18% 800kVA, 33/0.433kV, 3ph LT Transformer EA 2 Included 0.00 0 0.00
59 410 10 Install- 800 kV outdoor equipment 100003674 998736 18% 765kV , 3150A, 50kA GIS SF6 to AIR Bushing for connection of GIS to AIS EA 35 Included 0.00 0 0.00
60 410 20 Install- 800 kV outdoor equipment 100002094 998736 18% 800kV, 3000/3150 A, 50kA, Single phase, SF6 Gas Insulated Bus Duct (GIB) outside GIS Hall along with associated support structure. M 3400 Included 0.00 0 0.00
61 410 30 Install- 800 kV outdoor equipment 100000183 998736 18% 624kV Surge Arrester (1-Phase) EA 40 Included 0.00 0 0.00
62 410 40 Install- 800 kV outdoor equipment 100000146 998736 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 12 Included 0.00 0 0.00
63 410 50 Install- 800 kV outdoor equipment 100000194 998736 18% Erection of 765 kV, 1-Phase, Bus Post Insulator (except wave Traps) SET 39 Included 0.00 0 0.00
64 420 10 Install_145 kV Equipment 100001986 998736 18% 145kV, 1250A, 31.5KA Circuit Breakers(1-Phase) with support structure EA 2 Included 0.00 0 0.00
65 420 20 Install_145 kV Equipment 100001908 998736 18% 145kV ,1 phase Bus Post Insulators EA 4 Included 0.00 0 0.00
66 430 10 Install_33 kvEquipment 100000011 998736 18% Current transformer (33kV) for transformer Netural along with support structure & terminal connector SET 3 Included 0.00 0 0.00
67 430 20 Install_33 kvEquipment 100000047 998736 18% Current transformer (33kV) for Reactor Neutral along with support structure & terminal connector EA 4 Included 0.00 0 0.00
68 430 30 Install_33 kvEquipment 100000684 998736 18% 36kV, 1ph Bus post insulator SET 3 Included 0.00 0 0.00
69 430 40 Install_33 kvEquipment 100001935 998736 18% 36 kV, 400A, 25 KA, 3-Phase HDB Isolatorwithout E/S EA 1 Included 0.00 0 0.00
70 430 50 Install_33 kvEquipment 100000669 998736 18% 30kV Surge Arrester (1-Phase) EA 3 Included 0.00 0 0.00
71 430 60 Install_33 kvEquipment 100000701 998736 18% 36 kV, 3-phase Horn Gap Fuse EA 1 Included 0.00 0 0.00
72 440 10 Install_72.5 KV Equipment 100001909 998736 18% 72.5kV, Bus Post Insulator, 1-Phase EA 9 Included 0.00 0 0.00
73 440 20 Install_72.5 KV Equipment 100000624 998736 18% 72.5 kV Voltage Transformer (1- Phase) EA 3 Included 0.00 0 0.00
74 440 30 Install_72.5 KV Equipment 100000623 998736 18% 72.5 kV, 50A, 25 kA, 1-Phase CurrentTransformer with 120% extended currentrating EA 3 Included 0.00 0 0.00
75 440 40 Install_72.5 KV Equipment 100000611 998736 18% 72.5 kV, 1250A, 25 kA, 3-phase CircuitBreaker with support structure EA 1 Included 0.00 0 0.00
76 440 50 Install_72.5 KV Equipment 100000626 998736 18% 72.5 kV, 400A, 25 KA, 3-Phase DoubleBreak Isolator with out E/S EA 1 Included 0.00 0 0.00
77 450 10 testing and maintenane equipement 100000125 998736 18% EOT Crane for GIS Building for 800kV GIS station SET 1 Included 0.00 0 0.00
78 450 20 testing and maintenane equipement 100000124 998736 18% SF6 Gas processing Unit for 800kV GIS station SET 1 Included 0.00 0 0.00
79 450 30 testing and maintenane equipement 100000126 998736 18% Partial Discharge Monitoring System for 800kV GIS station SET 1 Included 0.00 0 0.00
80 450 40 testing and maintenane equipement 100003126 998736 18% SF6 Gas Analyzer EA 1 Included 0.00 0 0.00
81 450 50 testing and maintenane equipement 100002439 998736 18% SF6 Gas Leak Detector SET 1 Included 0.00 0 0.00
82 460 10 765 kV Control & relay 100000719 998736 18% 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 10 Included 0.00 0 0.00
83 460 20 765 kV Control & relay 100000720 998736 18% 765 kV Circuit Breaker Relay Panel without Auto Reclose (with Automation) EA 7 Included 0.00 0 0.00
84 460 30 765 kV Control & relay 100000723 998736 18% 765kV Transformer Protection Panel (For both HV & MV side)-(with Automation) EA 3 Included 0.00 0 0.00
85 460 40 765 kV Control & relay 100000724 998736 18% 765kV Reactor Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
86 460 50 765 kV Control & relay 100000725 998736 18% 765kV Bus Bar Protection Panel (Duplicate)-(with Automation) SET 1 Included 0.00 0 0.00
87 460 60 765 kV Control & relay 100000722 998736 18% 765kV Line Protection Panel (with Automation) EA 5 Included 0.00 0 0.00
88 460 70 765 kV Control & relay 100002499 998736 18% 765kV Reactor Protection Panel, including control & monitoring of 145kV CB for NGR By-passing arrangement. (with Automation) SET 2 Included 0.00 0 0.00
89 470 10 Substation automation system 100000770 998736 18% Complete Substation automation system for 765kV Main bay as per Technical Specification EA 10 Included 0.00 0 0.00
90 470 20 Substation automation system 100000776 998736 18% Complete Substation automation System for 765kV Tie bay as per Technical Specification EA 5 Included 0.00 0 0.00
91 470 30 Substation automation system 100000778 998736 18% Complete Substation automation System for 765kV Switchable Line Reactor Bay as per Technical Specification EA 2 Included 0.00 0 0.00
92 470 40 Substation automation system 100000783 998736 18% Complete Substation automation System for controlling and monitoring of Auxilary System including BCUs as per technicalspecification SET 1 Included 0.00 0 0.00
93 480 10 LT Switchgear 100000894 998736 18% 415V Main Switchboard SET 1 Included 0.00 0 0.00
94 480 20 LT Switchgear 100000895 998736 18% AC Distribution Board (ACDB) SET 1 Included 0.00 0 0.00
95 480 30 LT Switchgear 100000897 998736 18% 415V MLDB(along with 2 nos. 300 kVA Lighting transformer) SET 1 Included 0.00 0 0.00
96 480 40 LT Switchgear 100000899 998736 18% 415V Emergency LDB(along with 1 no. 100kVA lighting transformer) SET 1 Included 0.00 0 0.00
97 480 50 LT Switchgear 100000902 998736 18% 220V DCDB SET 2 Included 0.00 0 0.00
98 480 60 LT Switchgear 100000905 998736 18% 48V DCDB SET 2 Included 0.00 0 0.00
99 490 10 Batteries and charger 100000915 998736 18% 220V, 1500 Ah Battery SET 2 Included 0.00 0 0.00
100 490 20 Batteries and charger 100000931 998736 18% 48V, 1500 Ah Battery SET 2 Included 0.00 0 0.00
101 490 30 Batteries and charger 100000940 998736 18% 220V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.00
102 490 40 Batteries and charger 100000955 998736 18% 48V, 180A/180A Float Cum Boost BatteryCharger EA 2 Included 0.00 0 0.00
103 500 10 DG SET 100000956 998736 18% 500 kVA Diesel Generator along with control Panel EA 1 Included 0.00 0 0.00
104 510 10 Erection Harware 100000185 998731 18% Erection Hardware for 765kV I type layout-Transformer bay as per specification SET 3 Included 0.00 0 0.00
105 510 20 Erection Harware 100000186 998731 18% Erection Hardware for 765kV I type layout-Bus Reactor bay as per specification SET 2 Included 0.00 0 0.00
106 510 30 Erection Harware 100002019 998731 18% Erection Hardware for 765kV I type layout-Line Reactors including NGR bypassing arrangement as per technical specification SET 2 Included 0.00 0 0.00
107 510 40 Erection Harware 100002169 998731 18% Erection Hardware for 765kV I type layout for GIS termination arrangement-Line bay as per technical specification SET 4 Included 0.00 0 0.00
108 510 80 Erection Harware 100002036 998731 18% Erection Hardware for the 72.5kV equipment for Tertiary loading as per technical specification SET 1 Included 0.00 0 0.00
109 510 90 Erection Harware 100002037 998731 18% Erection Hardware for the 33kV equipment for SEB supply as per technical specification SET 1 Included 0.00 0 0.00
110 510 100 Erection Harware 100000005 998736 18% Bus post insulators, spacers, equipment support structures, conductors, Al tube, clamp, connectors (including 765kV, 400kV, tertiaryand neutural bushing terminal connectors etc) for arrangement of netural formation for Transformer(s), DELTA formation for one bank(each bank comprises of 3 single phase units of Autotransformers) and making connection arrangement to connect spare unit in placeof any unit of the bank without physical shifting LOT 3 Included 0.00 0 0.00
111 510 110 Erection Harware 100001957 998736 18% Bus post insulators, spacers, equipment support structures, conductor(s), Al tube, clamp, connectors including 765 KV and neutralbushings terminal connectors etc for Neutral formation for two banks (each bank comprise of three single phase units of Reactors)and connection to two neutral grounding reactors and making connection arrengment to connect spare unit in place of any unit of allthe two banks without physical shifting. LOT 2 Included 0.00 0 0.00
112 520 10 Air Conditioning & Ventilation System 100000960 995463 18% High wall type split AC unit of 2 TR capacity EA 20 Included 0.00 0 0.00
113 520 30 Air Conditioning & Ventilation System 100001873 995463 18% Ventillation system for 765KV GIS Hall SET 1 Included 0.00 0 0.00
114 530 10 Fire protection System 100000966 998736 18% Pumping arrangement for HVW system & hydrant system, complete with all piping, valves, fittings,etc. inside pump house for FireProtection System of 765/400/220kV (New) Substation SET 1 Included 0.00 0 0.00
115 530 20 Fire protection System 100000969 998736 18% Hydrant system, complete U/G piping and accessories etc. outside the Pump House for Fire Protection of 765/400/220kV (New)Substation SET 1 Included 0.00 0 0.00
116 530 30 Fire protection System 100001870 995461 18% Fire Detection and Alarm System for 765kV GIS Hall SET 1 Included 0.00 0 0.00
117 530 40 Fire protection System 100008180 998736 18% Fire Protection System for local relay room for 800kV GIS SET 1 Included 0.00 0 0.00
118 530 50 Fire protection System 100000981 998736 18% HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 500 MVA,(765/v3)/(400/v3)/(33) kV, 1 -phase Autotransformer SET 10 Included 0.00 0 0.00
119 530 60 Fire protection System 100001002 998736 18% HVW spray system, Hydrant system and complete U/G & O/G piping and accessories etc. out side the pump house for 110 MVAR, 765/#3 kVsingle phase Shunt Reactor SET 13 Included 0.00 0 0.00
120 530 70 Fire protection System 100000972 998736 18% 9litre water type Portable Fire extinguisher EA 4 Included 0.00 0 0.00
121 530 80 Fire protection System 100000975 995461 18% 4.5 kg CO2 type Portable Fire extinguisher EA 12 Included 0.00 0 0.00
122 530 90 Fire protection System 100002752 998736 18% 5Kg dry chemical powered type Portable Fire extinguisher EA 10 Included 0.00 0 0.00
123 530 100 Fire protection System 100008260 998736 18% 60 litre foam type Trolley/Wheel mounted Fire extinguisher EA 2 Included 0.00 0 0.00
124 530 110 Fire protection System 100000980 995461 18% Fire Detection and Alarm System for Control Room Building(765kV) SET 1 Included 0.00 0 0.00
125 540 10 Illumination(Indoor) 100008185 998736 18% Indoor Lightning for GIS Building (As per Technical specification) including AHU & Relay Rooms as applicable SET 1 Included 0.00 0 0.00
126 540 20 Illumination(Indoor) 100008184 998736 18% Indoor Lightning for DG set & Fire Fighting Pump House SET 1 Included 0.00 0 0.00
127 540 90 Illumination(Indoor) 100002487 998731 18% Security Room Illumination including conduit LS 1 Included 0.00 0 0.00
128 540 100 Illumination(Indoor) 100001118 998739 18% Control room cum administrative building (765kV) illumination including Conduit LOT 1 Included 0.00 0 0.00
129 550 10 Illumination(Outdoor) 100001021 995461 18% Lighting Panel type ACP-2 as per technical specification EA 3 Included 0.00 0 0.00
130 550 20 Illumination(Outdoor) 100001024 998731 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 10 Included 0.00 0 0.00
131 550 30 Illumination(Outdoor) 100004930 998731 18% LED Flood Light Luminaries Type-FL-1 as per technical specification EA 70 Included 0.00 0 0.00
132 550 40 Illumination(Outdoor) 100004931 998731 18% LED Flood Light Luminaries Type FL-2 (250W) as per technical specification EA 70 Included 0.00 0 0.00
133 550 50 Illumination(Outdoor) 100004932 998731 18% LED Street Light Luminaire TYPE SL-L1 (= 45W)as per technical specification EA 20 Included 0.00 0 0.00
134 550 60 Illumination(Outdoor) 100001052 998731 18% 63A, 415V : Interlocked switch socket outdoor Receptacle (type RP) as per technical specifications EA 2 Included 0.00 0 0.00
135 550 70 Illumination(Outdoor) 100001051 998731 18% 15A, 240V: Outdoor Receptacle 2 pole, 3-pin modular (type RO) as per technical specifications EA 2 Included 0.00 0 0.00
136 550 100 Illumination(Outdoor) 100001885 998739 18% Outdoor Power Receptacle for oilfiltration unit (250A) EA 3 Included 0.00 0 0.00
137 550 110 Illumination(Outdoor) 100004934 998731 18% Type L1 Street Lighting Pole of 6 meter as per technical specification. EA 20 Included 0.00 0 0.00
138 560 10 Power and Control Cables 100003094 998736 18% 33KV GRADE HT XLPE CABLE ALONG WITH CLAMPS,LUGS, GLANDS AND STRAIGHT JOINTS. KM 2 Included 0.00 0 0.00
139 560 20 Power and Control Cables 100002180 998736 18% 1.1kV grade Power Cables (XLPEinsulated) along withlugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0.00
140 560 30 Power and Control Cables 100008191 998736 18% 1.1kV Grade Power & Control Cable (PVC) for 765 kV Line Bay alongwith clamps, lugs, glands, straight through joints etc. SET 5 Included 0.00 0 0.00
141 560 40 Power and Control Cables 100008195 998736 18% 1.1kV Grade Power & Control Cable (PVC) 765 kV Tie Bay alongwith clamps, lugs, glands, straight through joints etc SET 5 Included 0.00 0 0.00
142 560 50 Power and Control Cables 100008192 998736 18% 1.1kV Grade Power & Control Cable (PVC) 765 kV ICT Bay alongwith clamps, lugs, glands, straight through joints etc SET 3 Included 0.00 0 0.00
143 560 60 Power and Control Cables 100008194 998736 18% 1.1kV Grade Power & Control Cable (PVC) 765 kV Bus reactor Bay alongwith clamps, lugs, glands, straight through joints etc SET 2 Included 0.00 0 0.00
144 560 70 Power and Control Cables 100008201 998736 18% 1.1kV Grade Power & Control Cable (PVC) 765 kV Line reactor Bay alongwith clamps, lugs, glands, straight through joints etc SET 2 Included 0.00 0 0.00
145 560 80 Power and Control Cables 100008270 998736 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
146 570 10 PLCC Equipment 100000881 998734 18% 765kV,3150A,1.0mH , 50kA Line Trap EA 8 Included 0.00 0 0.00
147 570 20 PLCC Equipment 100000882 998734 18% 765 kV ,1 phase Bus Post Insulators for Line Traps EA 24 Included 0.00 0 0.00
148 570 30 PLCC Equipment 100000886 998734 18% Coupling device for PLCC EA 4 Included 0.00 0 0.00
149 570 40 PLCC Equipment 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 3 Included 0.00 0 0.00
150 570 50 PLCC Equipment 100000890 998734 18% Protection Coupler (Analog) EA 3 Included 0.00 0 0.00
151 570 60 PLCC Equipment 100000891 998734 18% Digital Protection Coupler EA 3 Included 0.00 0 0.00
152 570 70 PLCC Equipment 100003517 998734 18% HF CABLE FOR PLCC-75 OHM (KM) KM 2 Included 0.00 0 0.00
153 570 80 PLCC Equipment 100002437 998734 18% Telephone Instruments (4 wire/Express) alongwith cabling EA 4 Included 0.00 0 0.00
154 570 90 PLCC Equipment 100000892 998734 18% EPAX (24/8) with 24 telephones, Cables etc. SET 1 Included 0.00 0 0.00
155 590 10 Common Equipment 100001891 998736 18% Time synchronisation equipment EA 1 Included 0.00 0 0.00
156 600 10 Main Earthmat 100003103 998731 18% 40 mm MS rod for Main Earthmat KM 8 Included 0.00 0 0.00
157 610 10 Steel Structure-Equipment 100008616 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV Class SA (1PH) EA 40 Included 0.00 0 0.00
158 610 20 Steel Structure-Equipment 100008615 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 12 Included 0.00 0 0.00
159 610 90 Steel Structure-Equipment 100008618 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 8 Included 0.00 0 0.00
160 610 100 Steel Structure-Equipment 100008617 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 39 Included 0.00 0 0.00
161 620 10 Telecom Equipment 100002812 998734 18% SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 3 Included 0.00 0 0.00
162 620 20 Telecom Equipment 170000433 998734 18% Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 8 Included 0.00 0 0.00
163 620 30 Telecom Equipment 170000374 998734 18% Optical Interface Card (to support minimum 150 kms) for STM-16 EA 4 Included 0.00 0 0.00
164 620 40 Telecom Equipment 100003449 998734 18% Optical Interface Card (to support minimum 175 kms) for STM-16 EA 4 Included 0.00 0 0.00
165 620 50 Telecom Equipment 100002822 998734 18% Optical Interface Card (to support minimum 225 kms) for STM-16 EA 2 Included 0.00 0 0.00
166 620 60 Telecom Equipment 100002825 998734 18% Tributary interface- E1 interface (Minimum 16 nos.) SET 6 Included 0.00 0 0.00
167 620 70 Telecom Equipment 170000550 998336 18% Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 6 Included 0.00 0 0.00
168 620 80 Telecom Equipment 100002829 998734 18% Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 3 Included 0.00 0 0.00
169 620 90 Telecom Equipment 170000375 998734 18% Equipment Cabinets-For SDH Equipments EA 3 Included 0.00 0 0.00
170 620 100 Telecom Equipment 170000376 998734 18% NMS-Craft Terminal-Hardware EA 1 Included 0.00 0 0.00
171 620 110 Telecom Equipment 170000377 998734 18% NMS-Craft Terminal-Software EA 1 Included 0.00 0 0.00
172 620 120 Telecom Equipment 170000551 998336 18% VOIP telephone instrument with one common switch (min. 8 port) EA 8 Included 0.00 0 0.00
173 620 130 Telecom Equipment 100002882 998336 18% Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 3 Included 0.00 0 0.00
174 620 140 Telecom Equipment 170000356 998336 18% Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 3 Included 0.00 0 0.00
175 620 150 Telecom Equipment 170000502 998713 18% Service:- Phasor Measurement Unit (PMU) EA 4 Included 0.00 0 0.00
176 620 160 Telecom Equipment 170000530 998734 18% WAMS TIME SYSTEM(GPS RECEIVER) EA 4 Included 0.00 0 0.00
177 620 170 Telecom Equipment 170000503 998713 18% Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 5 Included 0.00 0 0.00
178 620 180 Telecom Equipment 170000504 998713 18% Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.00
179 620 190 Telecom Equipment 170000501 998734 18% Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.00
180 630 10 Visual monitoring system 100000869 998736 18% Visual monitoring system for watch & ward SET 1 Included 0.00 0 0.00
181 680 10 PLCC Equipment @ Bhiwani SS 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0.00 0 0.00
182 680 20 PLCC Equipment @ Bhiwani SS 100000890 998734 18% Protection Coupler (Analog) EA 1 Included 0.00 0 0.00
183 680 30 PLCC Equipment @ Bhiwani SS 100000891 998734 18% Digital Protection Coupler EA 1 Included 0.00 0 0.00
184 690 10 Shifing of PLCC Eqpt - Bhiwani to Narela 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 1 Included 0.00 0 0.00
185 690 20 Shifing of PLCC Eqpt - Bhiwani to Narela 100000890 998734 18% Protection Coupler (Analog) EA 1 Included 0.00 0 0.00
186 690 30 Shifing of PLCC Eqpt - Bhiwani to Narela 100000891 998734 18% Digital Protection Coupler EA 1 Included 0.00 0 0.00
187 710 10 Structure- Misc 100008234 995455 18% Equipment Structure including Foundation bolt-72.5kV BPI (1Ph) EA 9 Included 0.00 0 0.00
188 710 20 Structure- Misc 100008231 995455 18% Equipment Structure including Foundation bolt-72.5kV CT(1Ph) EA 3 Included 0.00 0 0.00
189 710 30 Structure- Misc 100008232 995455 18% Equipment Structure including Foundation bolt-72.5kV PT (1Ph) EA 3 Included 0.00 0 0.00
190 710 40 Structure- Misc 100008233 995455 18% Equipment Structure including Foundation bolt-72.5kV Isolator (3Ph) EA 1 Included 0.00 0 0.00
191 720 10 Structures - For NGR by-passing 100010821 995455 18% Equipment Structure including Foundation bolt-145kV BPI (1Ph) EA 4 Included 0.00 0 0.00
Ext.765 bays at Khetri SS
192 40 10 Civil Works 100004518 995433 18% Excavation in all kind of soil including rock for all leads and lifts, backfilling, disposal of surplus earth within a lead up to2Km as per technical specification. The surplus earth shall be roughly graded . M3 11154 Included 0.00 0 0.00
193 40 20 Civil Works 100001325 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 586 Included 0.00 0 0.00
194 40 30 Civil Works 100001326 995454 18% Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 69 Included 0.00 0 0.00
195 40 40 Civil Works 100001327 995454 18% Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1823 Included 0.00 0 0.00
196 40 50 Civil Works 100001329 995454 18% Steel Reinforcement MT 218 Included 0.00 0 0.00
197 40 60 Civil Works 100001331 995455 18% Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 33 Included 0.00 0 0.00
198 40 70 Civil Works 100001714 995428 18% Stone spreading in switchyard excluding PCC M2 26000 Included 0.00 0 0.00
199 40 80 Civil Works 100001713 995424 18% Antiweed treatment M2 26000 Included 0.00 0 0.00
200 40 90 Civil Works 100008110 995421 18% 3.75m wide Bitumen road with earthen shoulder including 100 mm dia RCC Hume Pipe @ 100 metre interval as per drawing and TS (as perDSR item no 16.35 and 16.30.1) and including 225 mm thick WBM in three equal layers of 75 mm each as per CPWD specification. M2 6000 Included 0.00 0 0.00
201 40 100 Civil Works 100001735 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 250mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
202 40 110 Civil Works 100001736 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 300mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
203 40 120 Civil Works 100001737 995462 18% RCC culverts and cable trench crossings including supplying and laying hume pipe 450mm dia of grade (NP-3) excluding concrete as perspecification. M 30 Included 0.00 0 0.00
204 40 130 Civil Works 100001412 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section A-A M 1920 Included 0.00 0 0.00
205 40 140 Civil Works 100001413 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section B-B M 480 Included 0.00 0 0.00
206 40 150 Civil Works 100001414 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section C-C M 480 Included 0.00 0 0.00
207 40 160 Civil Works 100001415 995462 18% Drain including culverts but excluding concrete & reinforcement steel-Section D-D M 320 Included 0.00 0 0.00
208 40 170 Civil Works 100003437 995454 18% Switchyard Panel Room - Civil Works. All civil works as per drawing and specifications complete, including - brickwork, finishing(external and internal), windows etc. However, excavation, PCC, RCC and reinforcement shall be paid separately as per BPS. M2 89 Included 0.00 0 0.00
209 40 180 Civil Works 100002911 995432 18% Earthwork in excavation & filling in all types of soil and soft/disintegrated rock in open areas/nallas/channels, to the requiredslopes, shapes, levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain(dewatering), pumping, removal of slush, preparing embankments/marginal banks, loosening, dressing, spreading material in layers notexceeding 200mm, as per direction of Engineer-in-Charge, water flooding, compacting to achieve 95% consolidation at optimum moisturecontent, finishing etc. all complete, for all leads and lifts within leveling boundary, including disposal of surplus earth andstacking of unsuitable material within a lead of 2.0 Km beyond substation boundary, with all labour, material, tools, tackles andequipment, safeguards and incidentals, Royalty,taxes etc. as necessary, as per drawings, specification and directions of theEngineer-in-Charge. Clearing of jungle is included in this item. (Only excavation/cutting will be measured for payment purpose.) M3 27500 Included 0.00 0 0.00
210 260 10 765 kV Equipment 100000133 998736 18% 765kV, 3150A, 50kA Circuit Breaker(3-Phase) with closing resistor (withsupport structure) EA 4 Included 0.00 0 0.00
211 260 20 765 kV Equipment 100000143 998736 18% 765 kV, 3000A, 50KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 12 Included 0.00 0 0.00
212 260 30 765 kV Equipment 100000146 998736 18% 765 kV,8800 pF Capacitive Voltage Transformer (1-Phase) EA 6 Included 0.00 0 0.00
213 260 40 765 kV Equipment 100000171 998736 18% 765kV, 3150A, 50kA, Vertical Knee/DoubleBreak Isolator (3-Phase) with one E/S EA 8 Included 0.00 0 0.00
214 260 50 765 kV Equipment 100000172 998736 18% 765kV, 3150A, 50kA, Vertical Knee/DoubleBreak Isolator (3-Phase) with two E/S EA 2 Included 0.00 0 0.00
215 260 70 765 kV Equipment 100000183 998736 18% 624kV Surge Arrester (1-Phase) EA 6 Included 0.00 0 0.00
216 260 80 765 kV Equipment 100000194 998736 18% Erection of 765 kV, 1-Phase, Bus Post Insulator (except wave Traps) SET 21 Included 0.00 0 0.00
217 270 10 Erection Hardware 100000184 998731 18% Erection Hardware for 765kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0.00
218 270 20 Erection Hardware 100000192 998731 18% Erection Hardware for 765kV I type layout-Bus Work (For one diameters) as per specification SET 2 Included 0.00 0 0.00
219 280 10 765 kV Control & relay 100000719 998736 18% 765 kV Circuit Breaker Relay Panel With Auto Reclose (with Automation) EA 4 Included 0.00 0 0.00
220 280 20 765 kV Control & relay 100000722 998736 18% 765kV Line Protection Panel (with Automation) EA 2 Included 0.00 0 0.00
221 280 30 765 kV Control & relay 100000727 998736 18% Augmentation of existing 765kV bus bar protection scheme.(No. of bays as per specification)-(with Automation) SET 1 Included 0.00 0 0.00
222 290 20 Substation automation system 100002068 998736 18% Augmentation of Substation automation system for 765kV Main bay as per Technical Specification EA 2 Included 0.00 0 0.00
223 290 30 Substation automation system 100002074 998736 18% Augmentation of Substation automation System for 765kV Tie bay as per Technical Specification EA 2 Included 0.00 0 0.00
224 300 10 PLCC Equipment 100000881 998734 18% 765kV,3150A,1.0mH , 50kA Line Trap EA 4 Included 0.00 0 0.00
225 300 20 PLCC Equipment 100000882 998734 18% 765 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0.00
226 300 30 PLCC Equipment 100000886 998734 18% Coupling device for PLCC EA 2 Included 0.00 0 0.00
227 300 40 PLCC Equipment 100000888 998734 18% Carrier Equipment Analog type (for Speech+Data & Speech+Protection) EA 2 Included 0.00 0 0.00
228 300 50 PLCC Equipment 100000890 998734 18% Protection Coupler (Analog) EA 2 Included 0.00 0 0.00
229 300 60 PLCC Equipment 100000891 998734 18% Digital Protection Coupler EA 2 Included 0.00 0 0.00
230 300 70 PLCC Equipment 100003517 998734 18% HF CABLE FOR PLCC-75 OHM (KM) KM 1 Included 0.00 0 0.00
231 300 80 PLCC Equipment 100002437 998734 18% Telephone Instruments (4 wire/Express) alongwith cabling EA 2 Included 0.00 0 0.00
232 310 10 Air Conditioning System 100001881 995463 18% Air conditioning system for Switchyard Panel Room of 9m length SET 2 Included 0.00 0 0.00
233 320 10 Fire protection System 100001871 995461 18% Fire Detection and Alarm System for Switchyard Panel Room of 9 m length SET 2 Included 0.00 0 0.00
234 320 20 Fire protection System 100000975 995461 18% 4.5 kg CO2 type Portable Fire extinguisher EA 2 Included 0.00 0 0.00
235 330 10 Illumination(Indoor) 100001115 998739 18% Illumination System for switchyard panel room of 9 m length SET 2 Included 0.00 0 0.00
236 340 10 Illumination(Outdoor) 100001021 995461 18% Lighting Panel type ACP-2 as per technical specification EA 1 Included 0.00 0 0.00
237 340 20 Illumination(Outdoor) 100001024 998731 18% Sub Lighting panel (outdoor) type SLP (Switchyard and Street Lighting) EA 3 Included 0.00 0 0.00
238 340 30 Illumination(Outdoor) 100004930 998731 18% LED Flood Light Luminaries Type-FL-1 as per technical specification EA 20 Included 0.00 0 0.00
239 340 40 Illumination(Outdoor) 100004931 998731 18% LED Flood Light Luminaries Type FL-2 (250W) as per technical specification EA 20 Included 0.00 0 0.00
240 350 10 Power and Control Cables 100008191 998736 18% 1.1kV Grade Power & Control Cable (PVC) for 765 kV Line Bay alongwith clamps, lugs, glands, straight through joints etc. SET 2 Included 0.00 0 0.00
241 350 20 Power and Control Cables 100008195 998736 18% 1.1kV Grade Power & Control Cable (PVC) 765 kV Tie Bay alongwith clamps, lugs, glands, straight through joints etc SET 2 Included 0.00 0 0.00
242 350 30 Power and Control Cables 100008270 998736 18% 1.1KV GRADE OTHER CABLES (NOT COVERED ABOVE) ALONGWITH CLAMPS, LUGS, GLANDS, STRAIGHT THROUGH JOINTS ETC LS 1 Included 0.00 0 0.00
243 360 10 Main Earthmat 100003103 998731 18% 40 mm MS rod for Main Earthmat KM 4 Included 0.00 0 0.00
244 370 10 Steel Structures - Eqpt 100008614 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CT (1PH) EA 12 Included 0.00 0 0.00
245 370 20 Steel Structures - Eqpt 100008615 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV CVT (1PH) EA 6 Included 0.00 0 0.00
246 370 30 Steel Structures - Eqpt 100010110 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV ISO (3PH) EA 10 Included 0.00 0 0.00
247 370 40 Steel Structures - Eqpt 100008617 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV BPI (1PH) EA 21 Included 0.00 0 0.00
248 370 50 Steel Structures - Eqpt 100008618 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV WT (1PH) EA 4 Included 0.00 0 0.00
249 370 60 Steel Structures - Eqpt 100008616 995455 18% EQUIPMENT STRUCTURE INCLUDING FOUNDATION BOLT-765KV Class SA (1PH) EA 6 Included 0.00 0 0.00
250 380 10 Steel Structures - Tower 100001210 995455 18% Erection of Lattice Structures (MS Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts MT 284 Included 0.00 0 0.00
251 380 20 Steel Structures - Tower 100001209 995455 18% Erection of Lattice Structures (HT Steel), to be designed during detailed engineering, for towers, beams and equipment supportstructure including pack plates / packwashers and gusset plates excluding fasteners and foundation bolts. MT 98 Included 0.00 0 0.00
252 380 30 Steel Structures - Tower 100001680 995455 18% Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 14 Included 0.00 0 0.00
253 380 40 Steel Structures - Tower 100001681 995455 18% Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 18 Included 0.00 0 0.00
254 390 10 telecommunication Equipment 100002812 998734 18% SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0.00
255 390 20 telecommunication Equipment 170000433 998734 18% Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0.00 0 0.00
256 390 30 telecommunication Equipment 100002822 998734 18% Optical Interface Card (to support minimum 225 kms) for STM-16 EA 2 Included 0.00 0 0.00
257 390 40 telecommunication Equipment 100002825 998734 18% Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0.00
258 390 50 telecommunication Equipment 170000550 998336 18% Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 1 Included 0.00 0 0.00
259 390 60 telecommunication Equipment 100002829 998734 18% Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0.00
260 390 70 telecommunication Equipment 170000375 998734 18% Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0.00
261 390 80 telecommunication Equipment 170000551 998336 18% VOIP telephone instrument with one common switch (min. 8 port) EA 2 Included 0.00 0 0.00
262 390 90 telecommunication Equipment 100002882 998336 18% Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 1 Included 0.00 0 0.00
263 390 100 telecommunication Equipment 170000356 998336 18% Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 1 Included 0.00 0 0.00
264 390 110 telecommunication Equipment 170000502 998713 18% Service:- Phasor Measurement Unit (PMU) EA 2 Included 0.00 0 0.00
265 390 120 telecommunication Equipment 170000530 998734 18% WAMS TIME SYSTEM(GPS RECEIVER) EA 2 Included 0.00 0 0.00
266 390 130 telecommunication Equipment 170000503 998713 18% Installation of Substation Grade Layer-3 LAN Switches as per Technical Specification EA 3 Included 0.00 0 0.00
267 390 140 telecommunication Equipment 170000504 998713 18% Services:- Armored Fibre Optic Cable and associated termination equipment LOT 1 Included 0.00 0 0.00
268 390 150 telecommunication Equipment 170000501 998734 18% Integration of PMU with the PDC (Phasor Data Concentrator) of RLDCs and respective SLDCs as required. LOT 1 Included 0.00 0 0.00
Total Installation Charges 0.00 0 0
Total GST as confirmed by Bidder 0.00
Total Installation Charges 0.00
Total GST as confirmed by Bidder 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 3
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage lum-sum 0.00%
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! (a) Detailed Soil Investigation
#REF! #REF! #REF! #REF! #REF! (b) All kinds of soil except fissured rock & hard rock
#REF! #REF! #REF! #REF! #REF! (e) River Crossing Location
#REF! #REF! #REF! #REF! #REF! (f)
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
Total Erection Price (A+B) #REF!
Place : Printed Name :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule-4
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Training Charges for Training to be imparted
Date : -- Printed Name :
Place : Designation :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 5
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON GOODS Excise Duty #REF! Excise Duty #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable. 0.00
2 TOTAL GST ON SERVICES Sales Tax 0.00 Sales Tax 0.00
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4), if aplicable 0.00 #REF! 0 #REF! 0
GRAND TOTAL [1+2] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : -- Printed Name :
Place : Designation :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 5
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES 0.00
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4)
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 6
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule - 6 After Discount
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contracts Services, 3rd Floor
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, Insurance and other Incidental Services
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 Not Applicable
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 Not Applicable
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name :
Place : Designation :
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule 7
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests on Earthwire, Hardwar Fittings & accessories of conductor & earthwire:
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
Sub-Total (I) 0.00
TOTAL TEST CHARGES (I) 0.00
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Schedule 7
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contracts Services, 3rd Floor Total Discount #REF!
Name : …….. …….. …….. …….. …….. …….. Power Grid Corporation of India Ltd.,
Address : …….. …….. …….. …….. …….. …….. "Saudamini", Plot No.-2
…….. …….. …….. …….. …….. …….. Sector-29, Multipackage Discount 0.0000%
Type tests for Wangtoo Substation
SL. NO. HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) 0 Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
TOTAL TYPE TEST CHARGES 0.00
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : -- Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Rs. 0.00 0.0000000000%
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1, Sch-2 & Sch-3] In Percent (%) 0.00 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : Ex-Works Price 0.0000000000%
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance 0.0000000000%
Schedule-3 : Installation Charges In Rs. 0.00 0.0000000000% Schedule-3 : Erection Charges 0.0000000000%
Schedule-4 : Training Charges In Rs. 0.00 0.0000000000% Schedule-4 : Training Charges 0.0000000000%
Schedule-7 : Type Test Charges In Rs. Schedule-7 : Type Test Charges 0.0000000000%
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-3 : Installation Charges In Percent (%) 0.00 0.00%
Schedule-4 : Training Charges In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00%
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New Bid Form 2nd Envelope 0 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Contracts Services, 3rd Floor 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. 0 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 5 Taxes and Duties not included in Schedule 1 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions.
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of …….. …….. …….. …….. …….. ……..
Date : -- Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY 0 0.00
B) CENTRAL SALES TAX 0 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
Excise Duty % as Excise Duty
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. Statement of Quoted / Corrected Prices Page
Spec. No. TBCB/765kV/Phase-II/Rajasthan Part-G/GIS/SS01/G7/New
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] Not Applicable Not Applicable
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0 Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. 0 #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
Pre-Bid Tie-up for Substation Package - SS01 for Establishment of 765kV GIS substation at Narela & Construction of 2 Nos. of 765 kV line bays at Khetri for Khetri – Narela 765kV D/c line under Transmission Scheme for evacuation of power from solar energy zones in Rajasthan (8.1 GW) under phase II –Part G, through Tariff Based Competitive Bidding (TBCB) Route Prior to RfP Bid Submission By POWERGRID to BPC. Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01-First Envelope - Bid Form and Attachments_Ver-1.xlsx
xlsx • 1.12 MB
02_Attachment -3 (QR).xlsx
xlsx • 0.18 MB
03-SAFETY PACT.docx
docx • 0.03 MB
04_Attachment-8_Manufacturer Authorization Form.doc
doc • 0.03 MB
05_Attachment-20_KMP Declaration.doc
doc • 0.03 MB
06-Attachment 21- authorization certifacte issued by Domestci Manufacturer.docx
docx • 0.02 MB
07-Attachemnt-22- Affidavit for self-certification.DOCX
docx • 0.02 MB
08-Attachment-23_(Affidavit).docx
docx • 0.02 MB
09-Attachment-24_Confirmation in regard to Design and Type Test.docx
docx • 0.02 MB
10-Attachment-25 (Declaration regarding events encountered pursuant to ITB Clause 2.1).docx
docx • 0.03 MB
11-Second Envelope - Bid Form and Price Schedule.xlsx
xlsx • 2.00 MB
Section project 765kV Narela 030720.pdf
pdf • 0.97 MB
Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
Section-Switchgear-INST_rev11.pdf
pdf • 1.00 MB
Section-Switchgear-ISO_Rev11B.pdf
pdf • 0.11 MB
Section-Switchgear-SA_rev11.pdf
pdf • 0.10 MB
Lighting Specification Rev.07.pdf
pdf • 4.29 MB
LT SLD for AC & DC System.PDF
pdf • 1.66 MB
LT Transformer-Rev05.pdf
pdf • 0.07 MB
PLCC R5.pdf
pdf • 0.06 MB
Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
sec- CRP Rev 09.pdf
pdf • 0.37 MB
Section PMU Rev 0.pdf
pdf • 0.59 MB
Section project R00 (SS01).pdf
pdf • 1.13 MB
Section Structure Rev 6.pdf
pdf • 0.10 MB
Section Telecommunication Systems Rev 02.pdf
pdf • 1.78 MB
Air conditioning R4.pdf
pdf • 0.04 MB
Annexure-III Reactor Neutral.pdf
pdf • 0.18 MB
Appendix-II for SAS_Rev04_STANDARD FACTORY SIMULATION TEST PLAN.pdf
pdf • 0.54 MB
Batery&Charger R6.pdf
pdf • 1.05 MB
Civil Works Rev 11A.pdf
pdf • 2.00 MB
DG Set Rev 5.pdf
pdf • 0.27 MB
Fire Protection Rev 6.pdf
pdf • 1.97 MB
GIS Rev-5A.pdf
pdf • 1.95 MB
GTR-9.5_List of TTR not required.pdf
pdf • 1.80 MB
Section-GTR, Revision-14.pdf
pdf • 1.19 MB
Section-GTR, Revision-14_TS of RTV coating_Annexure H_Rev 1.pdf
pdf • 0.14 MB
17 FFPH & WT (TS-10).pdf
pdf • 6.98 MB
Isometric View of Labour Hut.pdf
pdf • 0.15 MB
1 Rail Cum Road.pdf
pdf • 1.30 MB
10 SPR 3 MTR NEW.pdf
pdf • 1.59 MB
12 SPR 6 MTR NEW.pdf
pdf • 1.62 MB
14 SPR 9 MTR NEW.pdf
pdf • 1.62 MB
2 CABLE TRENCH & CROSSING DETAILS.pdf
pdf • 0.63 MB
3 3.75 m wide ROAD TBCB.pdf
pdf • 0.10 MB
4 Road Culvert (TS-10).pdf
pdf • 1.50 MB
5 Drain (TS-10).pdf
pdf • 2.24 MB
7 Barbded Wire Fence.pdf
pdf • 0.47 MB
8 Switchyard Gate (TS-10).pdf
pdf • 1.20 MB
9 Approve drawing of RWH_2019.03.26.pdf
pdf • 0.19 MB
Annex-1 List of drawings.pdf
pdf • 0.54 MB
Annex-III Visual Monitorin System.pdf
pdf • 0.69 MB
Annex-II-Specific Requirement Rev 02_Annexures Merged.pdf
pdf • 11.53 MB
Annexure -III- Airconditioning & Ventilation System GIS Building.pdf
pdf • 0.42 MB
Annexure-IV Reactor Neutral.pdf
pdf • 0.18 MB
Annexure-V specification of HG Fuse.pdf
pdf • 0.10 MB
Annexure-VI-description of items of BPS given in shot.pdf
pdf • 0.19 MB
Annexure-VII-Technical Specification of Labour Hut_V1.pdf
pdf • 0.46 MB
~$- Section-III-BDS (GIS).docx
docx • 0.00 MB
~$- Section-V-SCC (GIS).docx
docx • 0.00 MB
~$1- IFB.docx
docx • 0.00 MB
~$-Section - VI Forms and Proceedures (GIS).doc
doc • 0.00 MB
~$-Section - VI Forms and Proceedures RT-01-30.04.18.doc
doc • 0.00 MB
01- IFB.docx
docx • 0.04 MB
02-Section - II ITB SSTE S&I Rev 5-DCB-Mjn.pdf
pdf • 1.95 MB
03- Section-III-BDS (GIS).docx
docx • 0.08 MB
04-Annexure-A (BDS).doc
doc • 0.07 MB
05-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06- Section-V-SCC (GIS).docx
docx • 0.05 MB
07 Annexure-I to SCC.pdf
pdf • 0.63 MB
08- Appendix-I to SCC.docx
docx • 0.04 MB
09-Section - VI Forms and Proceedures (GIS).doc
doc • 0.56 MB
Amendment_IV.docx
docx • 0.02 MB
OBD_EXTN_LETTER_6.doc
doc • 0.04 MB
OBD_EXTN_LETTER_5.doc
doc • 0.04 MB
OBD_EXTN_LETTER_5.doc
doc • 0.04 MB
Standard_AC_DC_SLD_765kVSubstation.pdf
pdf • 0.23 MB
OBD_EXTN_LETTER_4.doc
doc • 0.04 MB
Attachment -3 (QR)_rev1.xlsx
xlsx • 0.18 MB
OBD_EXTN_LETTER_3.doc
doc • 0.04 MB
OBD_EXTN_LETTER_2.doc
doc • 0.04 MB
OBD_EXTN_LETTER.doc
doc • 0.04 MB
Amendment-I.doc
doc • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .