Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹8.5 L SAPNA COMPLEX BATHUBASTI GARACHARMA PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 |
Tender Value
₹7.1 L
EMD Value
₹7,082
Closing Date
22 Jan 2025, 3:00 pmClosed
Setting up of Solar Water Heating system at Jawahar Navodaya Vidyalaya (Andman and Nicobar) under Hyderabad Region
NBCC/SBGSouth/JNV/Andaman/Solar/2025/64dated15/01/2025
NBCC/SBGSouth/JNV/Andaman/Solar/2025/64dated15/01/2025
Open Tender-Domestic
Machineries/Mechanical Equipment
Hyderabad, Telangana
₹2,950
₹7,082
17 Feb 2025
15 Jan 2025
22 Jan 2025
22 Jan 2025
24 Jan 2025
NVS (ANDAMAN & NICOBAR UNDER HYDERABAD REGION)
1.0 NS SOLAR WATER HEATING SYSTEM OF CAPACITY: 500 LPD EACH
Supply, Installation, Testing & Commissioning of 500 LPD Flat Plate based thermosyphone circulation Non-Pressurized Solar water heating Systems
comprising Flat Plate collectors , internal system piping, insulated hot water storage tank , Heat Exchanger, Electric Back up Heaters, plumbing accessories,
electrical items as required. Including DLP of complete system for 2 years and Guarantee/warranttee of Solar water heating unit for 5 years. Details Set 5 141636.00 708180.00
of each items to be used in one 500 LPD system are mentioned below:
ITEMS FOR 1 SET
SITC of 500LPD Solar FPC Collector & Storage Tank with Stand - 4 nos. of Solar Flat Plate Collectors of minimum 2030x1030mm size for minimum
2.0 Sq.Mtr. Absorber material shall be ETP grade Copper with copper Fins & Copper Tubes. The Flat Plate Collectors shall be as per IS 12933. Along
with 500LPD Solar Water Heating Tank made out of MS steel of 2.0 mm thickness and Manufacturer Standard Dish Thickness with internal epoxy/PU
coating OR SS 2mm thick and outer precoated Aluminium Cladding over 50mm PUF Insulation having density not less than 32Kg/Cu.mtr. With In-Built
Ladder type Heat Exchanger made of SS-304 & 5 Ltr SS (1mm thick) Expansion tank, maintenance free sacrificial/Magnesium Anode, provided with
Electrical Heater 2Nos. x 3KW electrodes with thermostat/ Auto Cut , Cold Water inlet, Hot Water outlet, Collector - Inlet and Outlet piping with
insulation. Collector & Tank Stands made out of MS angle iron size shall not be not less than 35mmx35mmx3mm, CC Foundation as per the direction of
Engineer incharge. (BIS 12933).
PLUMBING ITEMS PER SET
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass
threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and
testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
20 mm nominal dia Pipes (Min.: 15Mtrs OR as per actual site requirement)
Nitrile foam insulation of 9 mm thick with 26 gauge aluminium cladding for 20mm dia Hot water Pipe (Min.: 8Mtrs OR as per actual Site requirement)
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
20 mm nominal bore (Min.: 2nos. OR as per actual site requirements)
Providing and fixing gun metal non- return valve of approved quality (screwed end) :
25 mm nominal bore -Horizental (Min.: 2nos. OR as per actual site requirements)
Y Strainer -Screwed- 20mm dia -Bronze (Min.: 1nos.OR as per actual site requirements)
Air Release Valave- 20mm (Min.: 1nos.OR as per actual site requirements)
Auto Air Vent -20mm (Min.: 1nos.OR as per actual site requirements)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
15 mm nominal bore (Min.: 1nos.OR as per actual site requirements)
Dial Type Temprature Gauge 100mm dia (0-150deg) (Min.: 1nos.OR as per actual site requirements)
Control Panel / ACDB for Electrical Heater including required switchgear like DP MCB incommer & DP MCB outgoing of suitable ratings for each 3KW
Heater. Housed in Poly Carbonate (IP65) Enclosure, Complete with wiring up to heater in PVC Conduit.
Electrical Wiring for incoming to ACDB :
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required.
2 X 6 sq. mm + 1 X 6 sq. mm earth wire (Min.: 15mtrs OR as per actual site requirements)
Digitally signed by DEEPAK
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT Solar.pdf
Tender Document
SCC.pdf
Tender Document
GCC with Amendments.pdf
Tender Document
Scope of Work.pdf
Tender Document
Tender BOQ.pdf
Tender Document
Tender Drawing.pdf
Tender Document
Technical Specification.pdf
Tender Document
Make List.pdf
Tender Document
corrigendum-3378-Corrigendum 01.pdf
pdf • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .