Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAdmitted-Finance | ₹5.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹6.3 Cr+₹35.2 L (5.96%)Admitted-Finance | ₹6.3 Cr+₹35.2 L (5.96%) | L2 | Admitted-Finance |
| 3 | L3₹7.5 Cr+₹1.6 Cr (26.9%)Admitted-Finance | ₹7.5 Cr+₹1.6 Cr (26.9%) | L3 | Admitted-Finance |
| 4 | L4₹7.7 Cr+₹1.8 Cr (30.8%)Admitted-Finance | ₹7.7 Cr+₹1.8 Cr (30.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s V6 Infrastructures Pvt. Ltd. L2 | Onkar Nath Bhalla And Sons Contractor Pvt. Ltd. L4 | Kanwal Nain Behl L3 | M/s Vijay Kumar Garg L1 |
|---|---|---|---|---|---|---|---|
| 1.00BUILDING PART:- | |||||||
| 1.01 | SCHEDULE 'A' PART-I (SECTION-I)
Design, supply, fabrication and erection of pre-engineered building (PEB) steel structure for portion mark " PEB STRUCTURE WORKSHOP" including all civil works in RCC foundations duly designed, steel sliding motorised WORKSHOP door system to be provided on front of the WORKSHOP, including flooring, and the work listed in Sch 'A' notes and shown on drawings, design of PEB structure along with design for structural system for workshop door as per parameters for workshop and door as specified from approved firms as listed and vetting of design, drawing from IIT before acceptance of tender, complete all as specified and shown on drawings with the following:-
1.01 Contd. | 1 | Each Job | 2,00,00,000 ₹2,00,00,000 Lowest | 3,00,00,000 ₹3,00,00,000 | 3,15,00,000 ₹3,15,00,000 | 2,45,00,000 ₹2,45,00,000 |
| 1.02Note :- Rates quoted by the contractor shall also deem to include the cost of the following :- (i) Design of PEB structure WORKSHOP portion along with structural system for WORKSHOP door from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for workshop provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications. (v) The steel sliding motorised WORKSHOP door system for front doors for the WORKSHOP, shall be designed as specified in particular specifications. (vi) The design for structural system for the WORKSHOP door will also be vetted by the same organisation vetting the steel WORKSHOP Design. | |||||||
| 1.03 | Total amount of Sch 'A' Part-I (Section-II) (BLDG WORK) | 1 | Lump sum | 1,60,00,000 ₹1,60,00,000 | 2,00,00,000 ₹2,00,00,000 | 2,00,00,000 ₹2,00,00,000 | 1,54,94,500 ₹1,54,94,500 Lowest |
| 2.00 | Total amount of Sch 'A' Part-II (INTERNAL WATER SUPPLY WORK) | 1 | Lump sum | 21,344.93 ₹21,344.93 Lowest | 21,344.93 ₹21,344.93 Lowest | 50,000 ₹50,000 | 30,000 ₹30,000 |
| 2.01Total amount of Sch 'A' part-II (Section-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only | |||||||
| 2.02 | S & F CP urinal spreader for urinal complete all as specified and directed. | 15 | Each | 600 ₹9,000 | 600 ₹9,000 | 2,000 ₹30,000 | 500 ₹7,500 Lowest |
| 2.03 | S & F CP push type angle valve for urinal complete all as specified and directed. | 15 | Each | 1,000 ₹15,000 | 1,000 ₹15,000 | 1,500 ₹22,500 | 750 ₹11,250 Lowest |
| 2.04 | S & F CP health faucet with PVC tubing 1m complete all as specified and directed. | 15 | Each | 2,500 ₹37,500 | 2,500 ₹37,500 | 3,000 ₹45,000 | 1,000 ₹15,000 Lowest |
| 3.00 | Total amount of Sch 'A' Part-III ( PLUMBING WORK) | 1 | Lump sum | 41,762.26 ₹41,762.26 Lowest | 41,762.26 ₹41,762.26 Lowest | 60,000 ₹60,000 | 55,000 ₹55,000 |
Tender Value
₹3.4 Cr
EMD Value
₹4.2 L
Closing Date
28 Mar 2022, 6:00 pmClosed
CE AF UDHAMPUR
CE AF UDHAMPUR ZONE
WORKS SERVICES FOR COMMUNICATION PROJECT AT AF STATION JAMMU
2021_MES_463825_3
CEAFU-07/2021-22
Open Tender
Civil Works
Lump-sum
540 days
JAMMU
AS PER NIT AND TENDER DOCUMENT
10 documents required · 10 mandatory
₹2,000
GE AF JAMMU
₹4.2 L
Yes
2 May 2022
20 Dec 2021
30 Mar 2022
20 Dec 2021
28 Mar 2022
14 Mar 2022
Amount
BUILDING PART:-
SCHEDULE 'A' PART-I (SECTION-I) Design, supply, fabrication and erection of pre-engineered building (PEB) steel structure for portion mark " PEB STRUCTURE WORKSHOP" including all civil works in RCC foundations duly designed, steel sliding motorised WORKSHOP door system to be provided on front of the WORKSHOP, including flooring, and the work listed in Sch 'A' notes and shown on drawings, design of PEB structure along with design for structural system for workshop door as per parameters for workshop and door as specified from approved firms as listed and vetting of design, drawing from IIT before acceptance of tender, complete all as specified and shown on drawings with the following:- 1.01 Contd.
Note :- Rates quoted by the contractor shall also deem to include the cost of the following :- (i) Design of PEB structure WORKSHOP portion along with structural system for WORKSHOP door from PEB approved firm/vender as listed in particular specifications along with vetting of design/drawing from IIT . (ii) Design of RCC foundations. (iii) Arch drgs provided by the department will form part of contract however structural drawings for workshop provided by contractor, which will be vetted by IIT. (iv) The structural steel members shall be designed as specified here in before and in particular specifications. (v) The steel sliding motorised WORKSHOP door system for front doors for the WORKSHOP, shall be designed as specified in particular specifications. (vi) The design for structural system for the WORKSHOP door will also be vetted by the same organisation vetting the steel WORKSHOP Design.
Total amount of Sch 'A' Part-I (Section-II) (BLDG WORK)
Total amount of Sch 'A' Part-II (INTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' part-II (Section-II) (INTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S & F CP urinal spreader for urinal complete all as specified and directed.
S & F CP push type angle valve for urinal complete all as specified and directed.
S & F CP health faucet with PVC tubing 1m complete all as specified and directed.
Total amount of Sch 'A' Part-III ( PLUMBING WORK)
Total amount of Sch 'A' Part-IV (Section-I) (INTERNAL ELECTRIFICATION WORK)
Total amount of Sch 'A' part-IV (Section-II) (INTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply & fixing of LED integrated batten T5 of 1x18 W LED, 6500 K, 4 FT, White, indoor decorative PVC extruded T5 LED batten integrated type complete all as specified and directed.
S&F LED 600x600 mm aesthetically designed flat panel, 34 watts, 5700K complete for recesses /surface mounting, including connecting electricity to ceiling rose using cord flexible 3 core FRLS PVC insulated over all sheathed with flexible copper conductor of size 0.05 sqm all as required complete all as specified and directed.
S&F Lamp holder insulated body with back plate (ISI marked) for batten fittings including LED lamp of 10 Watt complete all as specified and directed.
S&F Surface mounted LED luminare for mirror lighting 10 watt Complete with lamp including connecting electrically to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.50 sqmm complete all as specified and directed.
S&F LED Street light fitting 40 Watt , IP66 power coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass including street light bracket made out of 40mm dia GI pipe light grade 1.2 mtr long ,bent to shape, with all necessary fittings i.e nuts,bolts, clamps made out of flat iron 50X6mm -02 nos.complete all as specified and as directed.
S&F Suspended type decorative integral high bay down lights 230 Volts 300 Watt LED anti perch pigeon spikes PVC for bird proofing of light, totally enclosed type with inbuilt electronic driver with APFC, lower THD, open circuit protection, surge voltage protection up to 10 KV with built in SPD Confirming to IS 15885 Part-2/Sec 13, closed version with aluminum alloy pressure die casted housing, reflector toughtened glass cover including fixing arrangement, complete all as specified and directed.
S&F Ceiling fan 5 star rated (as per BEE recommendation) 1200mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminium rotor complete with down rod, including fan regulator 5 steps two module flush in piano type, hanging of fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed.
S&F Heavy duty exhaust fan (as per BEE recommendation) 250mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminum rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed.
S&F Heavy duty exhaust fan (as per BEE recommendation) 450mm sweep 1400 RPM single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminum rotor mounted on two ball bearings complete louvers including cutting chases for fixing fan, connecting electrically using 3 core 0.75sq mm PVC insulated flexible copper conductor cable over all sheathed complete all as specified and directed.
S&F wall mounting single phase air circulator fan 400mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminum rotor mounted on two ball bearing complete louvers including cutting chases for fixing fan, connecting electricity using 3 core 0.75 sq mm PVC insulated flexible copper conductor cable over all Unsheathed complete all as specified and directed.
S&F wall mounting single phase air circulator fan 750mm sweep single phase 230 volts 50 Hz AC supply totally enclosed heavy duty motor with die cast aluminum rotor complete including fixing of fan, connecting electricity using 3 core,0.75 sq mm PVC insulated flexible copper conductor cable over all Unsheathed complete all as specified and directed.
S&F Distribution board, triple pole & neutral 415 volts iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incomer and MCB as outgoing 415 volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link confirming complete with one MCCB 4 pole 415 volts 250 amps rating with rupturing cap 36 KA of the same make as of distribution board and including cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as specified and directed.
S&F MCB single pole 240 Volts 6 to 32 amps with rupturing capacity 10 KA, complete all as specified and directed.
S&F MCB single pole 240 Volts 50 to 63 amps with rupturing capacity 10 KA, complete all as specified and directed.
S&F MCB single pole and neutral 240 Volts 50 to 63amps with rupturing complete all as specified and directed.
S&F MCB single pole and neutral 240 Volts 6 to 32amps with rupturing capacity 10 KA, complete all as specified and directed.
S&F MCB Triple pole and neutral 415 volts 50 to 63 Amps with rupturing capacity 10 kA type complete all as specified and directed.
Supply, installing, testing and commissioning of double door LT distribution panel boards Factory Made, cubical, indoor type powder coated with fabricated 1.6 mm thick skelton with angle iron/ flat iron frame work, bus Bar chamber , front operator hinged door with locking arrangement floor mounting type , IP-43 protection and as per IS 13947/(Part-I & Part-III) of 1993, including connecting with the incoming / out going feeders by providing cable glands and cable lugs complete , comprising the following accessories :- (i) MCCB 250 Amp TPN 50 HZ 415 V with rupturing capacity 36 KA (ICS=100%ICU) -01 No as (I/C) (ii) MCCB 125 Amp TPN 50 HZ 415 V with rupturing capacity 25 KA (ICS=100%ICU) -01 No as O/G (iii) MCCB 100Amp TPN 50 HZ 415 V with rupturing capacity 25 KA (ICS=100%ICU) -01 No as O/G (iv) MCCB 63 Amp TPN 50 HZ 415 V with rupturing capacity 25 KA (ICS=100%ICU) -01 No as spare Contd. to 4.19
Total amount of Sch 'A' Part-V SEC-I (HARD STANDING WORK)
Total amount of Sch 'A'Part-V SEC-II (HARD STANDING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F glow sign board of size 1200mmX900mm including all necessary electrification and fixing arrangement complete all as specified and directed.
Total amount of Sch 'A' Part-VI (AREA DRAINAGE WORK)
Total amount of Sch 'A' Part-VII SEC-I (SEWAGE DISPOSAL WORK)
Total amount of Sch 'A'Part-VII SEC-II (SEWAGE DISPOSAL WORK)Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
M&L for soakage well excavation in any type of soil foundation in PCC 1:3:6 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of brick masonry in CM 1:4 , RCC cover slab in M25 / SFRC cover , intercepting pipes of RCC/DWC filled with brick bats of size 1.8mX3m effective depth with over flow filter complete all as specified and directed.
M&L for LLDPE septic tank conventional type for 50 users, designed to carry sewage and sullage water , excavation in any type of soil , PCC 1:4:8 below foundation, vent shaft , necessary connection etc. complete all as specified and directed.
Total amount of Sch 'A'Part-VIII SEC-I ( LIGHTENING PROTECTION WORKS)
Total amount of Sch 'A'Part-VIII SEC-II ( LIGHTENING PROTECTION WORKS )Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply and Fixing of epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and directed.
Supply installation and commissioning of Digital grounding device mobile transportable earthing pit single phase comprising of 7 feet (01 feet vertical and 6 feet horizontal) 2 inches dia GI pipe electrode filled with high conductivity material. The horizontal portion is further encapsulated in 6 inches dia GI pipe filled with 35 Kg extremely low resistivity soil enhancement material ASEM GB for efficient conduction of fault current Qty 3 electrodes . each electrode is supplied with one PVC insulated 50 sqmm copper cable with lugs at both ends qty 03 to bound with MS distribution box to each other. When the electrodes are used as a sets of 04 or more a PGI distribution box having a busbar is provided for electrode bonding and load termination complete all as specified and directed.
Total amount of Sch 'A' Part-IX (Section-I) (EXTERNAL WATER SUPPLY WORK)
Total amount of Sch 'A' part-IX (Section-II) (EXTERNAL WATER SUPPLY WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Construction of masonry valve chamber of size 600X600X600 mm internal size, 100 mm thick foundation using PCC 1:4:8, type D-2, over 15cm thick hard core, 20cm thick solid block masonry with blocks cast using PCC 1:3:6, type C-1, set in cement mortar 1:4, 15MM thick plaster to internal surfaces and external surfaces up to 15cm below ground level and top of floor in cement and sand mortar 1:4, finished even and smooth with out using extra cement , 3.15mm thick MS sheet cover including 50mmX50mmX6mm thick MS angle frame fixed in PCC 1:2:4, type B1 coping with 25mmX6mm flat iron hold fasts, handle, hinges with locking arrangements, applying one coat of red oxide primer and two coats of synthetic enamel paint to all steel surfaces and earth work in any type of soil including disposal of surplus soil to a distance not exceeding 50M complete all as specified and shown on drawing.
Total amount of Sch 'A' Part-X (Section-I) (REFREGERATION AND AIR CONDITIONING WORK)
Total amount of Sch 'A' Part-X (Section-II) ((REFREGERATION AND AIR CONDITIONING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled wall mounted, copper wound with digital display indoor type for AC & designed for input variation between 140 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 3 % and of capacity 2 KVA complete all as specified and directed.
Total amount of Sch 'A' Part-XI (Section-I) (EXTERNAL ELECTRIFICATION WORK)
Total amount of Sch 'A' Part-XI (Section-II) (EXTERNAL ELECTRIFICATION WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply,Installation,testing and commissioning of 3 phase 50 Hz, Dry Type,Vacuum Pressure Impregnated (VPI) distribution transformer of ratings 160 kVA, 11/0.433 kV , Outdoor type ,Natural Air Cooled (ANAN) , conforming IS: 11171/1985 IS: 2026 Part ( I TO IV), and IEC726/1982 BEE certified.The transformer shall be suitably design to work satisfactorily under the tropical conditions of Jammu .The windings of the transformers shall be connected to Delta on the primary side and star (Y) on the secondary side. The neutral of the LT winding shall be brought out to a separate terminal. The vector group shall be Dyn-11.The transformer should be provided with winding tapped on HV side with Number of tap positions : 7 nos and . Voltage variations : (+) 5 percent to (-) 10 percent in steps of 2.5 % for variation of HV Voltage to be changed by means of hand operated "OFF LOAD" tap changing gear switch externally operated with mechanical locking and a position indicator,the winding temperature rise over an ambient temperature of 50°C shall not exceed 90°C when measured by resistance method. i.e. Max. Temperature of the winding shall not exceeds 140°C and losses of transformer as per BCBC norms,.Arcing horns for HT bushings for outdoor type T/F.The transformer shall be supplied with standard accessories and comprising of following specification as under:-Complete all as specified and as directed by Engr-in-charge. and including following: 11.02 Contd.
(a)Core:The core shall be of high grade cold rolled grain oriented (C.R.G.O) annealed silicon steel lamination confirming IS: 1271/1958 secured properly using frames , clamps and bolts. (b)Winding: HV & LV winding shall be done using High conductivity Electrolytic copper. with insulation –F-Class grade. (c) Enclosure: Enclosure shall be rectangular and shall be built of electrically welded MS sheet wire mesh or perforated sheet for ventilation and comply with IP 43 protection as per IS: 2147/IEC 529. (d)Lifting lugs -04 nos for vertical lifting and pulling lugs -04 nos for horizontal pulling . (e) Bidirectional mild steel rollers 150 mm. diameter and 75mm. width -04 nos (f)H. V. & L. V. BUSHING: Porcelain/ Epoxy HV and LV Bushings of appropriate voltage and current ratings shall be mounted in HV and LV cable box. The high voltage bushings (3nos.) shall be provided with R-Y-B colour coding marking & shall conform to IS 3347.Brass rods 12 mm. dia.-03 nos for HV Bushing terminal and Tinned copper rods 20 mm -04 nos for LV Bushings terminals/extension for cable lug connections, with necessary nuts, check nuts and plain thick tinned washers.
(g)Terminal marking plates and rating plates.:Terminals shall be provided with terminal marking plates. The transformer shall provide with riveted rating plate . The entries of the rating plate shall be indelibly marked (for example by etching, engraving or stamping). (h)Transformer should be provided with Platform mounting channel of suitable size with holes suitable for axle of roller) -2 Nos. (j)Painting:- The surface of the enclosure shall be properly pre-treated /phosphated in a seven enclosure process and shall be applied with a powder coating of 40 microns thickness of suitable colour code as per directions. (k) Four earth terminals per transformer, each suitable for earth conductors of size 32 x 6 mm GI strip for earthing of the body and neutral of the transformers. (l) Winding temperature indicator (WTI) -01 Nos.(m)The HV and LV side cable box with gland shall be provided. (Note :- (i) Contractor will submit lightening impulse withstand test, temp rise test, dynamic short circuit withstand test and measurement of acoustic sound level test report from CPRI/NABL/ Govt. approved laboratories (ii) contractor will submit the all stage test report as per PS of contract (iii) The rate include for supplying transformer with standard fittings and installing complete including all jointing materials, connecting with electrical system, earthing, cable ducting testing and commissioning. Foundation including platform for the transformer shall be as per OEM recommendation .Foundation shall be measured and paid separately.
S&F of expulsion fuse single pole of 11000 volts grade upto 100 amps capacity suitable for three phase HT supply complete all as specified and directed.
Material & labour for Earthing using Copper earth plate electrode of size 60cm X 60cm X 6mm thick buried directly in ground vertically at a depth not less than 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 32 x 6 mm by means welding/brazing and protected by light grade 40 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 3 of SSR Part-I 2009 for : (a) Transformer - 04, (b) LT Panel/ APFC Panel - 4, (c) Voltage Stabilizer- 02. (d) DG Set- 4 11.06 Contd.
Note:- (i) The unit rate shall include GI protection pipe 7.5Mtr, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, P.C.C chamber pit,. test point, Main earthing lead from earth electrode to test point upto 7.5 metre and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junction etc shall be deemed to be included in the unit rate. (iii) CI pit cover or precast RCC 1:2:4, type B-1, 80mm thick reinforced with XPM ( weighing not less than 4 Kg/sqm in lieu of cast iron cover).
Material & labour for Earthing using galvanised steel pipe electrode 40mm bore , medium grade ,burried directly in ground vertically at a depth not less than 2.5 mtr below normal ground level with top edge of earth plate at a depth not less than 1.25 mtr below normal ground level, earth plate surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 25 x 4 mm by means welding/brazing and protected by light grade 40 mm dia galvanised iron pipe and GI pipe light grade 20mm bore for watering, including funnel, wire mesh, CI pit cover and PCC chamber pit with PCC 1:2:4 type B-2 (including necessary excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr all as specified and shown on plate No 4 of SSR Part-I 2009 for : 11.08 Contd.
Note:- (i) The unit rate shall include GI protection pipe 7.5Mtr, GI water pipe, wire mesh, funnel, excavation, RCC pit cover, P.C.C chamber pit,. test point, Main earthing lead from earth electrode to test point upto 7.5 metre and if GI protection pipe is less than 7.5 metres, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500 mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fitting junction etc shall be deemed to be included in the unit rate.
S&F of synthetic insulating mat class A, working voltage up to 3.3 KV and dielectric strength 30 KV of size 2mX1mX25mm complete all as specified and directed.
Supply and Install Voltage stabilizer for automatic operation, three phase naturally oil cooled indoor type & designed for input variation between 300 V to 480 V with output voltage stabilized at 415 with accuracy ± 2.5% and of capacity 160 KVA conforming to IS. 9815 (Part-II) and Speed of correction of voltage shall be high enough to give jerkless out put voltage and in any case it shall not be less than 50 volts per second per phase without under/overshooting. Voltage stabilizers shall be with solid state sensor unit (IC Based) Relay free smooth and silent operation with servomotor and copper wound transformers in CRGO laminations including first fill of oil all as specified and directed.
Supply, install, test and commissioning of diesel engine driven silent generating set, 415 volts, 160 KVA 3 phase, 0.8 power factor, 50 Hz, brushless, 1500 rpm, self excited, self regulated, AC, and engine as per IS: 10001/ 10002 and alternator as per IS: 13364 complete with foundation, control panel with necessary meters, AMF Panel with relay and switch gear for automatic starting on mains failure including ON Load change over switch and MCCB of appropriate rating for by pass arrangements and sound proof canopy all as specified and as directed with and including following:- (a) ALTERNATOR: Standard design alternator rated at 160 KVA net output at site conditions and at power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles, 1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brushless design with hub and sealed ball/roller bearing, with winding on each pole faces, insulating class H, band of voltage regulation +/- 1% operated voltage from no load to full load and shell conforming to BS-2613/BS-5000 and shell be in position to ganerate supply with frequency regulation within +/- 3% tolerance, revolving field type. 11.12Contd
(b) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, water cooled, to drive independently above alternator and after considering derating as per site conditions directly coupled to alternator through flexible coupling or multicylinder, multistroke, direct injection, cold starting, 1500 rpm, as per relevant ISI/BS-5514 with an overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation. salient features of accessories shall be as under:- (i) Flywheel housing (ii)Air cleaner wet/dry type (iii) fuel Filter (iv) Fuel Injection system incl.injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling 11.13Contd.
(ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequate size, initial charging of batteries, battery charger/ generator with regulator, starter motor, starter gear, start and stop push buttons, ignition key and switch. (x) Residential type exhaust silencer complete with exhaust pipe of 150 mm dia upto outside the acoustic enclosure, all covered with glass wool wrapped with aluminium foil of 28 swg adequate to create draft for safe exhaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure, water pump, engine rpm, hour meter and protection against low oil pressure, high water temperature and over speed of engine incl. electronic governing. (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts, thermostat. (xiv) Fuel hoses. (xv) Air intake system (xvi) Common base frame of sturdy design suitable for antivibration mounting and permanent concrete foundation for mounting engine and alternator as per manufacturers instructions 11.14 Contd.
(c) CONTROL PANEL/AMF Panel: Control panel & AMF Panel shall be indoor cubical type made out of suitable thick CRCA sheet complete factory made, dust and vermin proof, totally enclosed with front opening of 415 V 3 phase, 4 wire system AC 50 Hz, having Aluminium busbar of capacity suitable for 110% full load of 128 KW generating set with overload protection relay, over voltage/under voltage protection, phase reversal and phase sequence correct, contactors of adequate size and ratings required for automatic starting of dg set in case of mains failure and shifting of loads from main to dg and vice versa, timers, switchgears, indicators, switches and standard accessories as per manufacturers recommendations. (d) Acoustic insulated enclosure/canopy for Generating set:- Acoustic enclosure shall be factory built suitable and conforming to the provisions of environment (protection) second amendment rules 2002 issued vide notification no. GSR371(E) dated 17 May 2002 at Sl No 94 (Para 1&3) (noise limit for warded DG Set upto 1000KVA type) and tested complete (e) Rubber mat class A, working voltage up to 3.3 KV and dielectric strength 30 KV of size 1mx2mx3mm with chequered finish ISI marked suitable for using in electrical installations NOTE: (a) The capacity of generator set shall be net after all de-rating factors as per relevant design.
M & L for construction of PCC platform for 160KVA transformer outdoor type made of brick masonry of size 3000x2500x1200mm complete all as specified and shown on TD drawing No. TD CE-1129 Sheets 1/2 all as specified and directed.
Supply, installing, testing and commissioning of double door LT distribution panel board Factory Made, cubical, out door type, powder coated with fabricated 3.15 mm thick skelton with angle iron / flat iron frame work , bus Bar chamber, front & back openable hinged door with locking arrangement ,floor mouting type, IP-65 protection and as per IS:13947(Part-I & Part-III) of 1993 ,including connecting with the incoming / out going feeders by providing cable glands and cable lugs complete, comprising the following accessories:- 11.17 Contd.
Supply, install test and commissioning of automatic power factor correction panel (APFC panel) Confirming to IEC 61921/IS 8623/IS 16636/IEC 61439 for 415V,AC,50HZ, heavy duty cylindrical capacitors of capacity 50 kVAR all as specified and directed.
Supply, installation, testing & commissioning of turbo ventilator, 24 inches windy type, high corrosion resistant, maintains free, energy saving type, FRP dome thickness min 2.0mm, FRP dome assembly FRP videotext type, (equivalent to UV Resin type). Fan weight should be min 6kg with 42 no of blades and blade thickness should be min 0.5mm, Top disc should be aluminum material and bearing will be ZZ double 6002, bottom ring will be Stainless steel and heavy air charge per hour (10-30) or as specified and as directed.
Total amount of Sch 'A' Part-XII (Section-I) (FIRE FIGHTING WORK)
Total amount of Sch 'A' Part-XII (Section-II) (FIRE FIGHTING WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Supply ,installation testing and commissioning of repeater panel complying with BS EN 54 suitable for wall mounting confirming to IS-2189 fabricated out of 16 gauge CRCA sheet incorporating audio visual indication including dry type maintenance free battery of suitable capacity and battery charger complete all as specified and directed.
Total amount of Sch 'A' Part-XIII (CHEMICAL EARTHING WORK)
Total amount of Sch 'A' part-XIV (EOT CRANE WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
Design, supply, installation, testing and commissioning of 05 Ton capacity flame proof EOT crane double girder class-II/M5 Medium duty. The Rail Bridge width is 25m (Exact size of the long and cross span will be ascertained after the design of shelter), electrically operated through pendant push button station floor operated type having hoisting height of 8 mtrs approx. trolley with frame, curb buffers, gear with gear boxes shafts, rope drum, rope sheaves, wire rope, wheels, lifting hook, platform on one side of the crane brackets, motors limit switches, control pendant push button station, micro speed arrangement, writing etc as per IS-3177, 807 all as specified below:- (a) Capacity : 05 tons (b) Crane Bridge-25 meters (c) Runway Girder-25 meters (d) Hoist lift-8.0 meters (e) Hoisting speed -3 mpm and creep/ micro speed 0.6 mpm. (f) Hoisting motor of suitable HP as per design calculation submitted by OEM /contractor (g) Cross travel speed-10 mpm and creep/micro speed 2.0 mpm . (h) Cross travel motor suitable HP for micro and main CT as per design calculation submitted by OEM/Contractor. (j) Long travel speed-15 mpm and creep/micro speed 3.0 mpm. (k) Long travel motor of suitable HP for micro and main LT qty as per design calculation submitted by contractor. (l) Operation pendant push button from floor (m) Class of duty-II (Indoor). 14.01 Contd.
(j)End Carriage: - End carriages should be ISMC type or as per manufacture design from rolled steel section with adequate diaphragms and stiffeners to give construction. Rubber buffers should be provided on other side of the end carriages.The end carriages should be fitted with suitable safety stops to prevent the crane from failing more than 25mm in the event of breakage of track wheel. (k) Painting: - The structural part of the cranes should be thoroughly cleaned and should be applied one coat of the red oxide and two coats of flame proof enamel paint before installing (l) Emergency stop Butt on: - Qty-01 Nos emergency stop push button should be provided on pendant. Note: The rate quoted by contractor shall be deemed to include with two year comprehensive maintenance with load testing after defects liability period by contractor.
Total amount of Sch 'A' Part-XV SEC-I (ALUMINIUM PARTITIONS WORK)
Total amount of Sch 'A' Part-XV SEC-II (ALUMINIUM PARTITIONS WORK) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only
S&F of powder coated anodised aluminium partition frame of natural anodised aluminium min 1.5mm thick of size 63.50X38.10mm including necessary jointing cleats and fixing frame of wall/floor with all fixing arrangement incl providing and fixing of 5.5mm thick sheet glass/12mm thick prelaminated partical board of 19X17.3X0.7mm on both side complete alongwith neoprene lining and incl door/window shutter cut to required length /width complete all as specified and directed. Note:- Aluminium frame will be provided with/without groves to accommodate glass ,grill etc. as per site requirement.
Total amount of Sch 'A' Part-XVI (SIGNAGE WORK)
Total amount of Sch 'A' part-XVII (SITE CLEARANCE AND EARTH WORK)
M/s V6 Infrastructures Pvt. Ltd.
Kanwal Nain Behl
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.27 MB
tenderdoc.pdf
Tender Documents • 15.47 MB
maindrg.pdf
Additional Documents • 22.59 MB
TDdrg.pdf
Additional Documents • 13.81 MB
BOQ_553963.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .