Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.4 LAccepted-AOC 145 SAINIK NAGAR RAIBARELLI ROAD TELIBAGH LUCKNOW | 1 | Accepted-AOC L-1 | |
| 2 | 2₹26.7 L+₹1.9 L (7.71%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹26.7 L+₹1.9 L (7.73%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹28.7 L+₹3.9 L (15.6%)Rejected-Finance 70 SUBHASH ROAD HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | 4 | Rejected-Finance Being other than L-1 | |
| 5 | 5₹30.6 L+₹5.8 L (23.3%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | 5 | Rejected-Finance Being other than L-1 |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
6 Sept 2022, 6:00 pmClosed
GE EAST LUCKNOW
GE EAST LUCKNOW
PROVN OF BOUNDARY WALL ALONG WESTERN BOUNDARY OF HQ 41 INF BDE CAMP AND OTHER SANCTIONED WORKS AT BARABANKI AND LUCKNOW UNDER GE (EAST) LUCKNOW
2022_MES_546082_1
GE/E/LKO/T-35 of 2022-23
Open Tender
Civil Works
Item Rate
180 days
GE EAST LUCKNOW
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE EAST LUCKNOW
₹64,000
Yes
6 Oct 2022
18 Aug 2022
8 Sept 2022
18 Aug 2022
6 Sept 2022
1 Sept 2022
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for brick work with modular fly ash bricks, straight or curved on plan exceeding 6 m mean radius in CM 1:6 complete all as specified and directed.
Taking down of cement plaster in any description on brick or stone wall etc. including racking out joints , hacking for key scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in patches in cement mortar 1:6 on other than fair face of brick work or concrete surfaces and finishing the surface even & smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in patches in cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smooth without using extra cement & with using integral water proofing compound complete all as specified and directed. Note:- WPC shall be measured and paid seperately .
M&L for preparation of newly plastered surface of walls and two coats of cement base paint over a coat of cement wash with portland cement slurry complete all as specified and directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper including preparatory to plastered surface for distempering complete all as specified and directed.
M&L for preparation of old plastered surfaces of walls and applying one coat of oil bound distemper of approved tint complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving , thickness not exceeding 15 cm above or below ground level complete all as specified and directed.
M& L for 75 mm thick plain cement concrete type D-2 (1:4:8), using 40mm graded stone aggregate as in sub base to receive floor finish etc complete all as specified and directed.
M&L for 20 - 25 mm thick machine cut kota stone slab flooring laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including griding, rubbing and polishing over and including 20 mm thick cement screet bed in CM 1:6 complete all as specified and directed.
M&L for 20 - 25 mm thick wax polished machine cut kota stone slab as on skirting / dado , laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for broken stone or boulder hard core of gauge not exc 63 mm , deposited , spread and levelled in layers not exc.15 cm thickness watered and rammed to a true surface complete all as specified and directed.
M&L for 75 mm thick cement concrete of mix 1:3:6 type C - 2, using 40 mm graded stone aggregate as in plinth protection and finishing the surface even and smooth with using extra cement complete all as specified and directed.
Dismantling asbestos cement (Corrugated, Semi corrugated etc.) sheets in roof coverings including ridges, hips, valleys and flashings complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self taping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall for ridges and eaves board fixed with self taping screws complete all as specified and directed.
Taking down of chowkhats or frames of area not exc 1.5 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down of chowkhats or frame of area exc 1.5 sqm but not exc 4 sqm each with shutters (without taking off shutters from the frames).complete all as specified and directed.
S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete, drilled for fixing of steel sheeting or other covering, doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive or steel sheeting or other covering, running rails and guides) and hanging ; also fastening and fixing complete all as specified and directed.
S&F steel window with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or welded including one shop coat painting complete all as specified and directed.
All as per Item No 21 here-in-before but without glazing bars.
M&L for 3.00 mm thick sheet figured glass and glazing with oil putty in square not exc 0.50 sqm in each panes fixed to steel or wooden window frames complete all as specified and directed.
S&F galvanised mild steel wire cloth 0.36 mm nominal dia of wire and avarage width of aparture 1.18 mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
M&L for preparing new surfaces of iron and iron based materials of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed.
Supply only integral water proofing compound .
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Excavation in trenches not exceeding. 1.5 m wide and not exceeding. 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed.
M&L for PCC of mix 1:4:8 , type D2 (using 40mm graded stone aggregate) as in mass concrete in foundation complete all as specified and directed.
M&L for brick work with subclass 'B' old size bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' old size bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as specified and directed.
S&F galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed complete all as specified and directed. Note:- Each line wire shall be measured .
M&L for PCC of mix 1:2:4 , type B-1 using 12.5 mm graded crushed stone aggregates in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed.
S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts , posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. , flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting etc. , and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
Returning , filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
Material and labour for one light / fan point controlled by one, one way switch 06 Amp wiring with 1.5 sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of sunk zinc coated pressed steel terminal box of 1.60 mm thick with 3 mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed.
All as per serial item No 39 here-in-before but one 3 pin, 06 amp socket outlet point on independent board controlled by one, one way switch 06 Amp complete all as specified and directed.
Material and labour for point wiring with 2.5 sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including casing capping /rigid non-metallic PVC conduit of 20 mm dia or higher, medium grade complete with and including all PVC accessories including gang box suitable for 15 Amp switch and socket complete all as specified and directed.
Supply and fix switch piano flush type, 06 Amp, single pole, one way, 230 Volt complete all as specified & directed.
Supply and fix socket outlet 2 in 1, 5 pin, 06 Amp, flush type, 230 volt complete all as specified & directed.
Supply and fix switch socket combination outlet 2 in 1, 3 pin, 06 Amp and 16 Amp flush type, universal, 230 volt, four hole complete all as specified & directed.
Supply and fix lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
Supply and fixing of integrated LED bulk head fitting 10 Watt, 6500K with IP 65 protection comprises of high pressure die cast aluminium housing, polycarbonate cover etc complete all as specified and directed.
Supply and fixing of single side connection LED T8 tube light rod 20 Watt, 6500K of four feet long into and including LED tube light fixture of four feet long with T8 push fit type holders, connector block, end caps etc including connecting up complete all as specified and directed.
Supply and fix ceiling rose , 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified and directed.
Material and labour for sub main wiring with 06 sqmm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed.
Material and labour for sub main wiring with 04 smm nominal cross sectional area, two single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 sqmm nominal cross sectional area, single core, 1100 Volt grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep , minimum air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Material and Labour in replacement of test point terminal block made out of gun metal of phospharus bronze fixed in 75 x 75 x 25 mm MS/polycarbonate enclouser drilled and screwed including 3 Nos of 8 mm dia 25 mm long screw complete all as specified and directed.
Supply & fixing in replacement air termination, single pointed aluminium rod of 12 mm dia and 300 mm length complete all as specified and directed.
Supply & fixing in replacement aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
M&L in replacement Earthing complete with copper earth plate electrode 60 cm X 60 cm X 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the copper strip 20 x 3 mm, by means of nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3 mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr ,all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20 x 3 mm copper strip complete all as specified and directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .