Chief Engineer Lucknow Zone
HQ CE Lucknow Zone, 17, cariappa marg, Lucknow 226002
PROVN OF SINGLE LIVING JCOs ACCN AT ME LINE OF COD KANPUR
2021_MES_449266_1
CELZ/KAN/T-14 of 2020-21
Open Tender
Civil Works
Lump-sum
450 days
Kanpur
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (I) Kanpur
₹1.9 L
Yes
17 Sept 2021
7 Jun 2021
4 Aug 2021
7 Jun 2021
2 Aug 2021
19 Jul 2021
10 Jun 2021 - 30 Jun 2021
Amount
Sch 'A' Part-I (Building Work) Note : This schedule is pre-priced by MES and the pre-priced rate indicated are under Col. 5.
Total amount of Sch 'A' Part II (Site clearance, excavation and earth work)
Total amount of Sch 'A' Part III (Internal Water Supply )
Total amount of Sch 'A' Part IV (Internal Electrification)
Total amount of Sch 'A' Part V (Sewage Disposal)
Total amount of Sch 'A' Part VI (Road, Path & Culvert )
Total amount of Sch 'A' Part VII (Area Drainage)
Total amount of Sch 'A' Part VIII (External Water Supply )
Total amount of Sch 'A' Part IX (External Electrification )
(Provisional sum of Rs 13,14,689.90) for :- (i) Provn of Septic tank for 50 users designed to carry sewage and sullage water, excavation in any type of soil , PCC 1:4:8 type D-2 below foundation, RCC M-30 design Mix in walls, base slab, Baffle walls and roof slab including beam etc with vent shaft, manhole opening with cover connection etc, complete with effective depth of 1.5 m and over all depth of 3 m complete all as shown in Drg No TD/750, Sheet 1/2 & 2/2 - (01 No). (ii) Provn of Soak well 2.40 meter dia and 4.50 meter effective depth with and including excavation in any type of soil, foundation in PCC 1:3:6 type C-2, walls of honey combed masonary with top ring M-25 design mix concrete including interceptings chamber and screen chamber made of brick masonary in CM 1:4 ,RCC cover slab of M-25 concrete / SFRC cover and interconnecting pipe of RCC /DWC complete all as shown in Drg No TD/576, Sheet 1/2 & 2/2 - (02 No).
Sch 'A' Part - X (Miscellaneous Items) Note - This Schedule is not pre-priced by MES and the pre - priced rate indicated as "Rs 0.00 under col.5 siginifies this fact only.
INTERNAL WATER SUPPLY S& F for Health faucet (1.50 m tube) with hook (hand spray) with CP body complete all as specified and directed.
S&F for Wall mixer chromium plated 3 in 1 with hand shower complete all as specified and directed.
INTERNAL ELECTRIFICATION M&L for Point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.
M&L for Point wiring complete for One light point controlled by two way switches with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of conduit not less than 20 mm shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on an independent board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of conduit not less than 20 mm shall be used without any extra cost.
M&L for Point wiring complete for one 5 Pin 5 Amp switch Socket outlet point on same board, with PVC insualted and unsheathed FRLS CABLE 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and MS conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed. Note :-In case of roof/ceiling, only MS black sheet conduit ISI marked dia of conduit not less than 20 mm shall be used without any extra cost.
M&L for Point wiring complete with PVC insulated and unsheathed, FRLS cable 2.5 sqmm (nominal area) ,ISI marked, multi-stranded copper conductor single core including ISI marked 20mm dia PVC conduit concealed in wall and MS conduit in roof/floorslab excluding flush metal GI boxes complete,including 1.5 Sqmm,FRLS cable PVC insulated unsheathed copper earth wire to the common earth and connecting to earth dolly,including colour coding of cable shall be Phase-red,Neutral-black and Earth- green with all accessories and all as specified Note :- In case of roof/ceiling, only MS black sheet conduit ISI marked dia of conduit not less than 20 mm shall be used without any extra cost.
Supply and fixing Sheet metal enclosures with socket plug top and one MCBs 20 Amps single pole and neutral enclosure with two pin and earth plug and socket complete all as specified and directed.
Supply and fixing telephone socket complete with all acessories complete all as specified and directed.
Supply and fixing TV socket complete with all acessories complete all as specified and directed.
Supply and fixing LED light fitting,1X20 Watt,(min 120 lumem/watt) 230 volts, 4 feet ,energy efficient type,ceiling /wall mounting, box type fitting, with epoxy powder coated CRCA sheet housing with reflector cover channel,complete with all accessories internaly prewired including including PVC insulated three core 23/0.0076 copper cable and includinding suitable size of pvc flexible conduit from celling rose to tube light fitting complete with ISI Marked complete all as specified and directed.
S&F energy saving 2 feet LED batten with 9 Watt LED with a nominal system output of 120 lumen/watt(min) with PF not less than 0.9 providing homogenous illumination, suitable for surface mounting with 4000Kintegrated high efficiency LED drive>85% non corrosive complete all as specified and directed.
S&F energy saving pressure die-cast aluminium IP 66 Building security/ roadway luminaire with high power 14 WATT LED with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 as light source with toughened glass including two core flexible copper wire of 1.5 sq mm from ceiling rose to the connector of fitting, connection wires not to be more than 2.5 in length and Bracket made out of GI tubing 35/40 mm dia/suitable dia light grade bend to shape security light fitting with necessary MS clamps 25 mm wide and 6 mm in thickness in suitable length not more than 30 CM and Max length of pipe 1.5 Mtr long with one code of anti corrosive primer and two coats aluminium paint including nuts, bolts and washeras complete all as specified and directed.
S&F Mirror light Decorative ultra slim square profile liner LED lighting fixture with extruded polycarbonate body with Minimum 8 Watt & Maximum 11 Watt LED warm white in colour with a nominal system output of 120 lum/watt(min) with PF not less than 0.9 complete all as specified and directed.
Supply and fixing recessed mounted circular LED down light of 10 watt system wattage constructed out of pressure die cast aluminium housing and premium quality PMMA diffuser having luminaire efficacy> 120 lum/W and provided witth surge supressor of 2.5 Kv complete all as specified and directed.
Supply and fix decorative wall mounting Engagement light chrome finish fixture with textured glass including 11 watts Red and Green LED lamp complete all as specified and directed.
Exhaust Fan high quality engineering plastic, resistant to colour change with anti- statio properties (ventil air) 200 mm sweep 35 watt ,1200 RPM with approved colour and with louver shutter complete including providing/cutting the round hole of required size in wall, fixing the frame and exhaust fan including fixing of louver shutter with frame on the exhaust side(outer surface of wall) and cutting with and including PVC insulated three core 23/0.0076 copper cable and suitable size of flexible conduit from celling rose to exhaust fan motor complete all as specified and directed.
Ceiling fan 1200 mm sweep single phase 230V AC, five star rating and ISI marked alongwith steel down rod and connecting up the fan to ceiling rose including provn of three core flexible copper cable of size 1.5 Sqmm for connection complete all as specified and directed.
MCCB 4 pole ,415 V ,AC fixed type 125 amps with breaking capacity 10 KA complete all as specified and directed.
MCCB VTPN DB double door type, 415 Volts AC, with 200 amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated ,powder coated complete with out MCCB and with enclosure blank plates for unused way suitable for 4 way complete all as specified and directed. Note: MCCB shall be measured and paid seprately under respective item.
MCB DB single pole with neutral sheet metal enclosure double door type, 240 Volts AC, with 200 Amp rated bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated, powder coated complete with out MCB and with enclosure blank plates for unused way suitable for 8 way complete all as specified and directed.
MCB single pole and neutral 40 Amps rating 'B' Series, 10 KA 240 volt complete all as specified and directed.
MCB single pole 6 to 32 Amp rating 'C' Series, 10 KA 240 volt complete all as specified and directed.
MCB single pole and neutral 16 Amps rating 'C' Series, 10 KA 240 volt complete all as specified and directed.
Submain wiring with two single core 2.5 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 2.5 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to cdommon earth and connection to earth dolly complete all as specified. Note:- Two single core 2.5 sqmm copper conductor, one run PVC conduit and one run of 2.5 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with two single core 4 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 4 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- Two single core 4 sqmm copper conductor, one run PVC conduit and one run of 4 sqmm earth wire shall be considered & measured as one unit.
Submain wiring with two single core 6 sqmm FRLS copper conductor, PVC insulated, multistranded, unsheathed cable ISI marked drawn in conduit concealed in wall surface / ceiling for sub main connection including 6 sqmm PVC insulated multistranded unsheathed copper conductor used as earth wire to common earth and connection to earth dolly complete all as specified. Note:- Two single core 6 sqmm copper conductor, one run PVC conduit and one run of 6 sqmm earth wire shall be considered & measured as one unit.
M&L for Earthing complete with galvanized steel earth plate electrode 600 x 600 x6 mm thick buried directly in ground (earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel wire 4mm dia as earth lead Earth plate to pole test point including 25mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 Type B-1 reinforced with 8mm dia TMT bars @ 8mm c/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 complete all as specified and directed.
ROAD PATH & CULVERT Providing and laying 2 mm thick hot applied thermoplastic road marking materials in uniform thickness with glass beads as per clause 8.3 of MOST specification complete all as specified and directed. Note : The work includes cleaning of roads surface heating the materials with in the specified temperature complete all as specified and directed.
EXTERNAL WATER SUPPLY Construction of brick masonary valve pit chamber of size 600mmx600 mm x900mm (internal dimensions ) including necessary excavation and earth work, PCC work in the foundation and top of the wall, plaster on internal surfacess with CM 1:4 cement mortar, Mild steel cover 3.15 mm thick and angle iron 40mmx40mmx6mm frame , locking arrangements with lock and key /pad lock brass 4 levers with key in duplicate), duly painting the steel surfacess with two coat of synthetic enamel paint over on coat of Red oxide primer complete all as specified shown on drawing and as directed.
EXTERNAL ELECTRIC SUPPLY Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 10 Sqmm 2 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply, laying, jointing and commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor through pipe/road crossing in ducts, on poles, trenches etc of size 50 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing cable jointing kit for 1100 volt grade cable for outdoor/ iindoor termination end joint heat shrinkable type complete with jointing materials and accessories suitable for XLPE/PVC armoured aluminium comnductor cable of size 10 Sqmm 2 core complete all as specified and directed.
Supply & fixing cable jointing kit for 1100 volt grade cable for outdoor/ iindoor termination end joint heat shrinkable type complete with jointing materials and accessories suitable for XLPE/PVC armoured aluminium comnductor cable of size 35 Sqmm 3.5 core complete all as specified and directed.
Supply & fixing cable jointing kit for 1100 volt grade cable for outdoor/ iindoor termination end joint heat shrinkable type complete with jointing materials and accessories suitable for XLPE/PVC armoured aluminium comnductor cable of size 50 Sqmm 3.5 core complete all as specified and directed.
Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below GL) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm thick by means of bolts, nuts, check nuts and washers of galvanised iron or steel including necessary excavation & earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4), type B1 using (20 mm graded stone aggregate), mild steel frame made out of angle iron of size 40 mm x 40 mm x 3 mm thick duly painted with two coats of synthetic enamel paint with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6 mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering, 15 mm dia light grade GI pipe for lead protection in and including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No. 3 connected to earthing test point all as specified and indicated including testing on completion as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply, erecting and installation of steel tubular, swaged, pole of overall length 9 meter having maximum tensile strength 42 Kgf/mm2 of type 410 SP-31 conforming to IS-2713-1980, single swan neck made out of 50 mm dia MS pipe 1.5 mtr long to be jointed on top of LT pole incl fabrication work for fixing street light. A through hole of 14 mm dia shall be provided at height of 2.5 mtr from base plate for inserting 2 core cable from junction box to top of the pole and top portion shall be fabricated for fixing street light fittings including earth work complete with cast iron base plate, having suitable dia of hole through the pole with nuts & bolts for earthing arrangement, bottom portion of tubular steel pole having 165.10 mm outer dia in 5 meter length, 4.5 mm wall thickness, middle portion having 139.70 mm outer dia in 2 metre length 4.5 mm wall thickness and top portion having 114.30 mm outer dia in 2 meter length, 3.65 mm wall thickness of pole wall, respectively, bottom MS square plate duly painted with two coat of black bituminous paint throughout, internally and externally up to planting depth and painting remaining portion of pole with two coats of aluminium paint to the entire exposed surfaces over one coat of red oxide primer making / pasting three nos circular strips each of 100 mm wide with one yellow and 02 Nos black colour strip synthetic enamel paint and marking / stencil writing of pole numbers with black paint including necessary excavation & earth work, removing excavated soil from site complete all as specified & directed. Note :- Necessary Excavation and earth work, PCC Work for foundation / erection of pole assembly will be deemed to be included in the unit rate.
Supply and fixing high power LED street light 60 Watt IP 66 Energy saving & environmental frindly long life Versatile pressure dia cast aluminium road way luminaire with high power LEDs as light source and electronic driver fixed on pole/wall alongwith service bracket as per sample, clamps, nuts, bolts and washers as directed including electric connection with 1.5 sqmm multistranded twin core aluminium cable PVC insulated from junction box to light fittings laid in in pole/ service bracket complete all as specified and directed.
Supply and fixing weather junction box of Size nearest 328 mmx 239 mmx129 mm, outdoor type made out of thermo polycarbonate to accmmodateed 04 nos aluminium bus bar of size 25x6 mm rating 200 Amps and MCB SP 6 Amps IP-65 with hinged door and tringular locks shocked proof, rust proof, corrosion free, acid resistance/fire retardent and self extinguishing UV resistance complete including fixing of thimbles and cable gland complete all specified and directed.
Supply, installation, testing and commissioning of LT feeder pillar box outdoor type of size 0.90x0.60x0.50 mtr factory febricated made out of MS sheet of thickness 3.15 mm, front door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm, 1.5 mtr long, 1.00 mtr aboe ground level and 0.5 mtr embedded in PCC block of size 0.30x0.30x0.50 mtr-04 Nos , duly painted with two coats of synthetic enamel paint over a coat of red oxide primer as colour directed by GE complete with 200 Amps ratd aluminium bus bar suitable for 3 hase 4 wire supply system duly drilled holes and MCB DP 63 Amps-06 Nos and makg all cable connection with proper thimbles mounted on epoxy based insulators and one MCCB 100 Amps 4 pole 415 Volts, 35/36 KA complete all as specified & directed.
DESERT COOLER Supply and installation of desert cooler 230 volts single phase having nominal air flow capacity of 5000 Cum per hours steel body complete and including wiriting MES No in black synthetic enamel paint etc complete all as specified and directed.
M & L for fixing MS angle iron support for fixing of deseret cooler including nut, bolts, painting and grouting of angle iron in wall including PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) and painting as per match to existing complete all as specified and directed.
HOT WATER SUPPLY Supply and installation of energy efficient electric water heater (Geyser) storage type having heating coil of capacity 1.5/2 KW BEE 5 star raiting, single phase of capacity 25 ltr with cold rolled steel tank with glass coating inside tank including fixing on wall with required fastners, nuts, PVC flexible connectons with two brass adopter and making electric connection and wiriting MES No in black synthetic enamel paint /engraving tool etc complete all as specified and directed.
Deepesh Electricals
M/S SDS Construction Co.
M/s R.V. Constructions
MD BUILDER
BHARAT ASSOCIATES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .