Loading…
Loading…
Tender Value
₹8.5 L
EMD Value
₹10,600
Closing Date
15 Sept 2026, 5:30 pm4d left
Karnataka Power Transmission Corporation Limited
Md Shabaz Ahmed
Providing air conditioners and other allied works to the control room building at 220kV R/S Shahabad
KPTCL/2026-27/OW/WORK_INDENT4093
KPTCL/2026-27/OW/WORK_INDENT4093
Reserved
Other Works
Two Tender Document System(Two Cover)
KPTCL CEE Transmission Zone Office Kalburgi
6 documents required · 6 mandatory
Refer NIT and Tender document
₹500
₹10,600
4 Sept 2026
31 Aug 2026
17 Sept 2026
14 Sept 2026
KARNATAKA POWER TRANSMISSION CORPORATION LIMITED
Estimate for Providing air conditioners and other allied works to the control room building at 220kV R/S Shahabad 10
Sl. No Particulars No L B D/H Qty Unit Qty Rate Rate inclusive of KKR @ 5% Amount
1 Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board. (a) 16A Three Way 5 Pin Socket KPWD SR 2023-24 (vol-6) 10/3.14.12 No 11 115
2 Supplying of .. TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 3star, 1.5 Ton capacity KPWD SR 2023-24 (vol-6) 31/6.8.2 Each 11 45284
3 IInstallation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support upto 3.0 Ton split/cassette type KPWD SR 2023-24 (vol-6) 32/6.12 Each 11 3175
4 Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v input and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 3KVA Capacity KPWD SR 2023-24 (vol-6) 38/9.1.1 Each 11 3995
5 Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and out door unit Leak testing oil and gas charging for additional piping length of tube. KPWD SR 2023-24 (vol-6) 32/6.13.1 m 20 1549 19.8
6 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. KPWD SR 2023-24 (vol-6) 5/2.3.3 & 2.3.4 m 120 42 19.8
(a) 2.5sqmm (CR Ele) 1 2 60 m
7 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plate swith due groove cutting in Brick/C.Cwall, including necessary rawlplugs, Machine/NF screws etc., complete. KPWD SR 2023-24 (vol-6) 8/3.3.3,3.3.5, 3.3.6 & 3.3.8 (a) 4-5 Way Each 11 137
(b) 8 Way Each 3 219
(b) 10-12Way Each 2 261
(c) 18 Way Each 1 339
8 Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. KPWD SR 2023-24 (vol-6) 8/3.5.3, 3.5.5, 3.5.6 & 3.5.8 (a) 4 Module Each 11 175
(b) 8 Module Each 3 284
(b) 10-12 Module Each 2 344
(c) 18 Module Each 1 457
9 Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. KPWD SR 2023-24 (v-6) 2/1.2.1 m 66
CR Ele 2 1 20 m
10 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 15 mm nominal dia Pipes KPWD SR 2023-24 (v-2) 122/13.31.1 (all AC water outlet upto flagging) m 30 182
11 Removing the existing/damaged steel windows etc. with or without frame, without damaging to the door shutter or door frame or to the structure etc. KPWD SR 2023-24 (vol-1) A-49/II & III Job 1
Carpenter Class I 1 2 514.28
Helper to Carpenter 2 2 499.43
12 Transportation of released material to the nearest store including loading and unloading of materials complete as per the directions of the Engineer-in-charge. KPWD SR 2023-24 (vol-5) 149/13.3.18 & (vol-1) A-50/5 Job 1
Transportation charges 1200
Mazdoor 3 1 470.28
13 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. KPWD SR 2023-24 (vol-2) 88/11.35.2.2 Kg 571
No. L Kg/m Weight
(a) Partition 1.00x3.55
Horizontal 2 1 1 @ 0.999 Kg
Vertical @ 0.60 c/c 2 1 3.55 @ 0.999 Kg
(b) Door Shutter 1.00x2.00 (Partition)
Top Horizontal 1 1 0.92 @ 1.42 Kg
Mid Horizontal 1 1 0.92 @ 1.495 Kg
Bottom Horizontal 1 1 0.92 @ 0.999 Kg
Vertical 2 1 2 @ 1.505 Kg
(c) Main Door (R/S) 1.80x2.96
Top Horizontal 2 1 1.8 @ 0.000 Kg
Bottom Horizontal 2 1 1.8 @ 0.695 Kg
Vertical 2 2 2.96 @ 0.695 Kg
(ii) Shutter section
Horizontal 2 4 0.88 @ 0.000 Kg
Vertical (outer) 2 2 2.9 @ 0.000 Kg
Vertical (interlock) 2 2 1.11 @ 0.000 Kg
Hoz. Ventilator 2 2 0.88 @ 0.000 Kg
(d) Window (three track) 1.80x1.20
Top Horizontal 7 1 1.8 @ 0.000 Kg
Bottom Horizontal 7 1 1.8 @ 0.695 Kg
Vertical 7 2 1.2 @ 0.695 Kg
(ii) Shutter section
Horizontal 7 6 0.55 @ 0.000 Kg
Vertical (outer) 7 3 1.11 @ 0.000 Kg
Vertical (interlock) 7 3 1.11 @ 0.000 Kg
Hoz. Ventilator 7 3 0.55 @ 0.000 Kg
14 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. KPWD SR 2023-24 (vol-2) 89/11.37.1 sqm 988
D Glass 1 1 0.94 0.95 sqm
MD Glass 2 2 0.9 1.1 sqm
MD (V) Glass 2 2 0.9 0.3 sqm
W Glass 7 3 0.54 0.85 sqm
W (V) Glass 7 3 0.54 0.3 sqm
15 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer- in-charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. KPWD SR 2023-24 (vol-2) 89/11.36.2 sqm 983
Partition 1 1 0.94 1.4 sqm
16 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately). KPWD SR 2023-24 (vol-2) 108/12.82 (For Windows 7x3x2=42) No. 42 22
17 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. KPWD SR 2023-24 (vol-2) 105/12.59 No 5 1114
18 Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete KPWD SR 2023-24 (vol-2) 105/12.62 No 10 237
19 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete. KPWD SR 2023-24 (vol-2) 105/12.63 No 5 130
20 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 75mm KPWD SR 2023-24 (vol-2) 107/12.77.4 No 3 384
21 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. KPWD SR 2023-24 (vol-2) 200/20.28 No 5 236
22 Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI > 80. Power Input: 220-240V@ 50/60Hz & Power factor >0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W KPWD SR 2023-24 (V-6) 34/11.3.2 Set 20 690
23 Fixing all types and all capacities of fluorescent /false ceiling /spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall / ceiling / Rafter / Girders KPWD SR 2023-24 (V-6) 45/13.7.1 Each 20 122
24 Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep(1200mm) Regular model KPWD SR 2023-24 (V-6) 30/6.3.1 Each 6 2984
25 Fixing a ceiling/Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. KPWD SR 2023-24 (V-6) 57/13.10 Each 6 171 Ele Wiring
26 Extra length of GI pipe of class B 19mm dia for down rod. KPWD SR 2023-24 (V-6) 57/13.12 m 6 197
27 Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (a) 400W dimmer KPWD SR 2023-24 (V-6) 9/3.6.5 Each 6 276
28 Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc.,with provision for fixing suitable type capacity MCB's singlephase/3phase/single door with powder coated painting Made out of 14SWGMS enclosure. I - Single Door 12 Way SP & N KPWD SR 2023-24 (vol-6) 18/5.19.4 Each 1 1863
29 Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. KPWD SR 2023-24 (vol-6) 21/5.46.1 & 5.46.3 (a) 16 - 32 A SP Each 6 210
(b) 63A SP Each 3 376
Sub-total 845503.37
30 Miscellaneous and Unforseen items LS 616.37 105.07
B Credit Estimate Unit Qty Rate Amount
1 Steel W 7 2 Kg kg 19
Information on works which are yet to be completed
(EXISTING COMMITMENTS AND ON-GOING WORKS)
Description of work Place & State Cotact No & date Name and address of Employer Value of contract Rs. Lakhs Stipulated period of completion Value of works remaining to be completed (Rs.Lakhs) Anticipated date of completion
Attach Certificate for each work indicated above, in Format 1, obtained from the Competent Authority
Countersigned by the Employer in charge TENDERER (Signature & Seal)
Information of the works for which Tenderer has submitted Tender
Project Name Name & Address of the Employer Name of Work Amount put to Tender in Rs lac. Specified period of completion (including/excluding Monsoon Prescribed last date of submission of tender Probable date of decision on the Tender Remarks if any.
TENDERER (Signature & Seal)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Estimate.xls
Others - Estimate • 0.07 MB
KW-1 Tender documents.docx
Tender Document • 0.10 MB
Self Declarations.docx
Others - Self declarations with signature • 0.03 MB
nit 220kV Shahabad.doc
Instructions to Tenderers • 0.08 MB
Tender Capacit_formats.xlsx
Others - Tender capacity formates with signature • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .